This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
93 - Regulatory (Subpart C or D), Gross Ton
85 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-51175
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Make permanent repairs to hole in hull IWO port fuel tank to the satisfaction of the attending Marine Inspector prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline
Issued 18 June 1997Resolved
PROPERLY SECURE BILGE PIPING IN FORWARD RAKE.
Condition: Unknown
Due 18 July 1997
Resolved 11 September 1997
Electrical
Issued 18 June 1997Resolved
PROVIDE RUBBER MAT ON DECK IN FRONT OF ELECTRICAL PANEL IN ENGINE ROOM.
Condition: Unknown
Due 18 July 1997
Resolved 11 September 1997
Lifesaving
Issued 18 June 1997Resolved
REPLACE 121.5 CLASS "A" EPIRB WITH 406 EPIRB IN ACCORDANCE WITH 46CFR199.620(M)(i).
Condition: Unknown
Due 18 July 1997
Resolved 11 September 1997
Construction/Loadline
Issued 18 June 1997Resolved
REPAIR CRACKED WELD IN FRAME STARBOARD SIDE STERN IN LAZARETTE.
Condition: Unknown
Due 18 July 1997
Resolved 11 September 1997
Accommodation/Occupational Safety
Issued 18 June 1997Resolved
REMOVE WASHER AND DRYER SET UP ON MAIN DECK. AS AN ALTERNATIVE, PROVIDE A BETTER SECURING ARRANGEMENT, BETTER ACCESS AND PERMANENT WIRING, SUPPLY WATER AND DRAIN WATER.
Condition: Unknown
Due 18 July 1997
Resolved 11 September 1997
Lifesaving
Issued 9 May 1996Resolved
PROVE OPERATION OF THE AFT SPEAKER FOR THE PA SYSTEM.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Lifesaving
Issued 9 May 1996Resolved
PROVIDE THREE ADDITIONAL LIFE PRESERVER LIGHTS TO REPLACE THE THREE NON- OPERATIONAL LIGHTS.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Construction/Loadline
Issued 9 May 1996Resolved
MAKE PERMANENT REPAIRS TO BOTH BOW VOIDS AT THE FORWARD END, MAIN DECK. REPAIRS SHALL BE MADE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Lifesaving
Issued 9 May 1996Resolved
CONDUCT SATISFACTORY FIRE AND ABANDON SHIP DRILLS.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Documentation
Issued 9 May 1996Resolved
PROVIDE OFFICER'S LICENSES FOR REVIEW.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Navigation
Issued 9 May 1996Resolved
PROVE OPERATION OF THE FATHOMETER AND GYRON COMPASS.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Fire Fighting
Issued 9 May 1996Resolved
PROVIDE A COPY OF THE FIRE EXTINGUSIHER SERVICING REPORT.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Construction/Loadline
Issued 9 May 1996Resolved
FREE UP THE COVER FOR THE PORT FUEL OIL VENT.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Navigation
Issued 9 May 1996Resolved
CONDUCT A SATISFACTORY TEST OF THE STEERING GEAR WITH THE VESSEL IN THE WATER.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Lifesaving
Issued 9 May 1996Resolved
PROPERLY INSTALL THE LIFERAFT ABOARD THE VESSEL.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Fire Fighting
Issued 9 May 1996Resolved
CONDUCT TESTING OF THE FIRE PUMP, FIRE MAIN, AND FIRE STATIONS.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Fire Fighting
Issued 9 May 1996Resolved
REPLACE THE FIRE EXTINGUISHERS BACK INTO THE BRACKETS.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Construction/Loadline
Issued 9 May 1996Resolved
Make permanant repairs to the superstructure, starboard side, aft of secondladder, above aft lazerette, also to the fractures in the bow void in way of centerline bulkhead #1 frame and #2 frame starboard bulkhead below lightning hole
Condition: Unknown
Due 9 May 1996
Resolved 9 May 1996
Navigation
Issued 9 May 1996Resolved
PROVIDE CURRENT TIDE AND CURRENT TABLES.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Construction/Loadline
Issued 9 May 1996Resolved
REPAIR WATERTIGHT HATCH FOR THE AFT LAZERETTE AND PROVE WATER TIGHT INTEGRITY.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Fire Fighting
Issued 29 March 1995Resolved
PROVE PROPER OPERATION OF FIRE PUMP. VESSEL IS NOT TO OPERATE UNTIL REPAIRSARE MADE.
Condition: Unknown
Due 30 April 1995
Resolved 31 March 1995
Lifesaving
Issued 15 April 1992Resolved
_x001C_ _x001C_ _x001C_ PROVIDE 6 HANDHELD ORANGE DISTRESS SIGNALS
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Lifesaving
Issued 15 April 1992Resolved
REPLACE 08 PFD CHEMICAL LIGHTS WITH 08 CG APPROVED LIGHTS.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Engineering
Issued 15 April 1992Resolved
CONSTRUCT AND INSTALL 3 DRIP PANS WITH FLAME SCREENS IN WAY OF BULKHEAD MOUNTED FUEL OIL FILTERS.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992