11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 September 2025
Resolved
Each item of lifesaving equipment determined by the
marine inspector to not be in serviceable condition must
be repaired or replaced. Lifeline and floating waterlight lanyard on ring life buoy was dry rotted. Replace lines.
46 CFR 176.808(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2025
Resolution: Rotted line was replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 September 2025
Resolved
Abandon ship, man overboard, and fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Log of drills was missing. Perform and log drills.
46 CFR 185.520(f)
46 CFR 185.524(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2025
Resolution: Drills were conducted and logged.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 September 2025
Resolved
All observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Insulation was hanging down from the ceiling and onto the 01 deck batteries, causing fire hazard. Secure insulation.
46 CFR 176.830(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2025
Resolution: Insulation removed from batteries.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 September 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Galley light switch cover was cracked and outdoor outlet on 01 deck was missing cover.
46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 11 September 2025
Resolution: Observed covers replaced/installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2025
Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured. Minor chafing was observed on fuel return line on port engine against the engine mount. Secure line to prevent chafing.
46 CFR 182.455(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2025
Resolved 11 September 2025
Resolution: Observed chafing gear installed
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 8 September 2025
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. The Safety Radiotelephony Certificate was expired. Vessel restricted to 1,000 feet from shore.
47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 18 September 2025
Resolution: Received evidence of new Safety Radiotelephony Cert
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 8 September 2025
Resolved
Stations in the maritime service must be licensed by the FCC. Station License was expired. Vessel restricted to 1,000 feet from shore.
47 CFR 80.13
Action required: 705 - Other - as specified
Resolved 16 September 2025
Resolution: Observed new station license onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 September 2025
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. During COI inspection, vessel was unable to conduct man overboard drill due to lack of crew. Within 7 days of issuance of this CG-835V, coordinate a man overboard drill while underway using vessel's equipment and procedures with minimum crew per COI to the satisfaction of the attending marine inspector.
46 CFR 176.808
Action required: 705 - Other - as specified
Resolved 16 September 2025
Resolution: Observed satisfactory drill
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 August 2025
Resolved
A vessel not more than 19.8 meters (65 feet) in length is not required to carry a rescue boat unless: (1) The vessel carries passengers on an open or partially enclosed deck; and (2) The cognizant OCMI determines that the vessel is designed, arranged, or involved in operations so that the vessel itself cannot serve as an adequate rescue craft. The forward embarkation ladder, which is used during man overboard drills to allow for rescue, has a damaged and frayed cable for the winch.
46 CFR 180.210(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2025
Resolution: Cable for forward winch has been replaced and MI witnessed the operation of the winch and associated gangway.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 18 August 2025
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. The starboard side handrail closest to the bow of the vessel on the embarkation ladder was found to be cracked at the bottom connection point.
46 CFR 177.900(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2025
Resolved 20 August 2025
Resolution: Received verification of handrails being repaired.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 August 2024
Resolved
Provision must be made for closing all supply duct
cowls or scoops and exhaust duct discharge openings for
a space protected by a fixed gas extinguishing system.
All closure devices must be readily available and
mounted in the vicinity of the vent. Ventilation was
unable to be fully secured when tested; requiring
ventilation closes fully before operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2024
Resolved 13 August 2024
Resolution: Ventilation functional and sealed; photo proof uploaded.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 August 2024
Resolved
Each cable entering a box or fitting must be protected
from abrasion, and must meet the following requirements:
Each opening through which conductors enter must be
adequately closed... In damp or wet locations, each
cable entrance must be watertight... Each junction box,
connection box, and outlet box for use in a damp or wet
location must be of watertight construction. Loose
wiring found in Engine Room and Bar Compartment. Recommended securing in junction box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 6 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 October 2023
Resolved
Operator was unable to prove operation of bilge system. Make repairs and prove operation of bilge suction in each watertight compartment to the satisfaction of the attending Marine Inspector. 46 CFR 182.500(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 2 October 2023
Resolved 3 October 2023
Resolution: Witnessed operation of all bilge suctions.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2023
Resolved
Vessel permanently installed two 5000W heaters on the upper deck without plan approval or installation verification. Provide elementary one-line diagram of heater installation, cable list, rating of circuit breakers and switches, and electrical load analysis or remove heaters. Heaters are not to be operated prior to plan approval and installation verification.
10/27/2023: Vessel rep has disconnected heaters and tagged out breaker while Hargrove completes elementary one-line diagram of heater installation, cable list, rating of circuit breakers and switches, and electrical load analysis. Heaters are not to be reconnected until plans are approved and installation is completed to the satisfaction of the Coast Guard.
10/12/23: Vessel rep requested 14 day extension for def no. 2. Extension granted and due to expire 10/30/2023
Action required: 705 - Other - as specified
Due 16 October 2023
Resolved 3 November 2023
Resolution: Load Analysis received and verified plant is sufficient to operate 5kW heaters.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 September 2021
Resolved
Second deck fire hose has a hole.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2021
Resolved 15 September 2021
Resolution: Operator replaced with a new fire hose.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 September 2021
Resolved
Temporary electric cords were found throughout the vessel being used as permanent electrical installations on second deck band area, bar, operationg station, along railings on the vessel, and 1st deck bar area.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2021
Resolved 15 September 2021
Resolution: Operator removed all surge protectors and reduced load to each outlet to reduce the risk of overloading the circuit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2021
Resolved
Two of the liferings on the vessel were found to be deterorated and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 28 September 2021
Resolution: Received image of new lifebuoys that replaced old ones.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 September 2021
Resolved
Vessel did not have max passenger capacity signs going to 2nd deck and up to the operating station as required by stability letter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 28 September 2021
Resolution: Received image that stickers have been attached to vessel limiting top deck passenger counts.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 September 2021
Resolved
Fire extinguisher on the second deck bar area did not have a bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 30 September 2021
Resolution: Provided photo of approved bracket.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 August 2019
Resolved
Charts not up to date. Update charts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2019
Resolved 5 September 2019
Resolution: Procured updated charts
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 August 2019
Resolved
Retro reflective tape on all life jackets needed replacement. Replace retro on all life jackets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2019
Resolution: Placed SOLAS Reflective tape over worn retro.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 August 2019
Resolved
Public address system inoperable. Repair PA system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2019
Resolution: Repaired PA System
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 19 August 2019
Resolved
Emergency procedures were not posted at the operating station. Post procedures at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2019
Resolved 22 August 2019
Resolution: Posted emergency procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2019
Resolved
Emergency fuel shut off handle was inaccessible. Provide access to emergency fuel shut off handle.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2019
Resolved 22 August 2019
Resolution: Installed a bulkhead cutout to ensure easy access to the fuel shut off.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 August 2019
Resolved
Steel jacketed flex hose attached to the intake side of the fire pump was found to be leaking. Replace in kind as per original design.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2019
Resolved 22 August 2019
Resolution: Installed in kind, a new section of flexable hose.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 August 2019
Resolved
Mast head light inoperable. Repair or replace the mast head light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 August 2019
Resolved 22 August 2019
Resolution: Replaced in kind mast head light.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 August 2019
Resolved
First aid kit not approved. Acquire necessary items.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2019
Resolved 5 September 2019
Resolution: Procured USCG approved first aid kit
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 19 August 2019
Resolved
Stability letter not posted at the operating station. Post stability letter at the operating station.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2019
Resolved 22 August 2019
Resolution: Mounted stability letter at the operating station.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2019
Resolved
No passenger limit decal IAW the vessels stability letter posted on the second deck. Post new decal leading up to the second deck.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 August 2019
Resolved 20 August 2019
Resolution: Posted passenger count sign leading up to second deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2019
Resolved
Dead end wires were found exposed on the starboard side immediately outside the bridge door. Remove or reconnect exposed wires.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2019
Resolved 22 August 2019
Resolution: Reconnected exposed wires.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 19 August 2019
Resolved
Portable emergency lights missing at the operating station and in the engine room. Install working lights at both the operating station and in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2019
Resolved 5 September 2019
Resolution: Procured working portable lights
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2019
Resolved
Ammeter missing from battery charger. Install ammeter on the battery charger.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2019
Resolved 5 September 2019
Resolution: Procured new battery charger with ammeter included.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2019
Resolved
Identified evidence of a slight hydraulic fluid leak coming from the piston seals on the hydraulic steering ram. Repair or replace hydraulic steering ram.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2019
Resolved 5 September 2019
Resolution: Hydraulic leak repaired, no sign of leakage.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 21 September 2018
Resolved
Public address system inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2018
Resolved 25 October 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 September 2018
Resolved
Dead end wires in second deck concession area. Remaove or place in proper junction box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2018
Resolved 25 October 2018
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 21 September 2018
Resolved
Vessel does not have a max passenger count placard for the second deck. Max count as per stability letter on second deck is 130.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2018
Resolved 25 October 2018
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 10 August 2017
Resolved
Fire pump does not reach proper pressure (35 PSI vice 60 PSI), show proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 24 October 2017
Resolution: Fire pump was tested to the satisfaction of the MI.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Crankcase
Issued 10 August 2017
Resolved
#2 generator is inoperable, make operable.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 October 2017
Resolution: #2 generator operable to satisfaction of the MI.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 10 August 2017
Resolved
Engine room ventilation closures do not fully close, make closures vapor tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 October 2017
Resolution: Ventilation dampers properlly working to the satisfaction of the MI.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 10 August 2017
Resolved
EPIRB self test/ignite switch does not return to the close position, have EPIRB serviced to show proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 October 2017
Resolution: Epirb fixed and operable to satisfaction of the MI.
Fire Fighting › Fire Main › Condition
Issued 10 August 2017
Resolved
Fire station on the 02 deck is inoperable, make operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 October 2017
Resolution: Fire station operable and satisfactory to the MI.
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 August 2017
Resolved
Electronic compass is showing deviation, verify proper operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 October 2017
Resolution: Compass operable to satisfaction of the MI.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 August 2017
Resolved
Secure galley/concession stand appliances.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 October 2017
Resolution: Galley and concession stand appliances secured to the satisfaction of the MI.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 August 2017
Resolved
Forward bow void watertight hatch is not moused, mouse hatch to vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 October 2017
Resolution: Watertight hatch moused to satisfaction of MI.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 August 2017
Resolved
Forward engine room bulkhead has broken receptacle, repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 October 2017
Resolution: Receptacle replaced.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 10 August 2017
Resolved
Stern has loose wires on 01 deck, either remove the wires or place wires in watertight enclosure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 October 2017
Resolution: Wires secured to satisfaction of the MI.
Engineering › Bilge Water Management System › Valve
Issued 10 August 2017
Resolved
Remove check valve from the fire main/bilge system or provide portable hand pump for each space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 24 October 2017
Resolution: Removed Check valve in firemain/bilge system.
Communications › Alarms/Indicators › High Water Alarm
Issued 10 August 2017
Resolved
High water alarm becomes disabled after acknowledging any single compartment, make operable.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 29 January 2018
Resolution: High water panel was changed with individual visual and audible alarms. Checked satisfactory.
Fire Fighting › Ventilation Systems › Ducts
Issued 24 May 2016
Resolved
Port and starboard-side engine room ventilation duct closure inop. Ensure ventilation to engine room may be secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Adjusted vent closures.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 24 May 2016
Resolved
Spaces toring (and protected by) carbon dioxide not properly marked. Ensure spaces are properly marked.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Compartments were labeled.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 May 2016
Resolved
Dishwasher, soda machine, and alcohol are unsecured. Ensure gear adrift is secured for rough weather.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Added shelf supports for underway safety.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 24 May 2016
Resolved
Provide current radio operator permits for all acting captains.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Provided marine operator permit.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 24 May 2016
Resolved
Drug consortium roster is not up-to-date. Provide updated drug consortium roster.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: DAPI letter roster with all crew members.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 May 2016
Resolved
EAP supervisor training certification not completed. Provide certification for all acting captains.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Supervisory training completed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 24 May 2016
Resolved
Grey water valve not labeled on tank on starboard side. Ensure all valves are properly labeled.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Valve labeled.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 24 May 2016
Resolved
Galley windows are cracked and broken. Repair or replace windows.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Windows replaced.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 24 May 2016
Resolved
Ground tackle (anchor) does not have mousing to secure shackle. Ensure mousing is provided for ground tackle.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Mousing added to anchor.