DOUBLE EAGLE III

DOUBLE EAGLE III is a 1980 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1984, most recently in January 2026, along with 230 deficiencies and 2 casualty investigations between 2018 and 2021.

Records from 1984 to 2026. Most recent: inspection, 20 January 2026.

Built
1980
Last inspected
20 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ7560
Flag
UNITED STATES
367016070
Maury page id
psix-51194

Inspections, by type

…with no type recorded7
Years with a record 42 calendar years (1984–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)77.7 ft × 32.8 ft × 6.2 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderQUEEN CRAFT INC · PANAMA CITY, FL, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCLEARWATER, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ7560MMSI 367016070 · active · compulsorily equipped · granted 22 January 2026, expires 22 January 2036 · licensed under a name not among this hull’s recorded names (not shown)
WYQ7340MMSI 367016070 · expired · compulsorily equipped · granted 8 January 2015, cancelled 24 May 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 78

20 January 2026 Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8279599
18 June 2025 Drydock Exam · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8161790
13 January 2025 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8045048
29 January 2024 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7847478
28 September 2023 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7746516
14 September 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7792057
11 January 2023 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7601822
10 January 2022 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7364831
3 September 2021 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7218147
18 August 2021 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7291139
25 January 2021 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7130430
19 January 2021 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7114901
13 January 2020 DAPI Audit · Administrative Inspection · Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6870913
23 September 2019 Examination of Repairs · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6747465
4 February 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6610926
7 November 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6580371
4 December 2017 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6317640
6 September 2017 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6180200
17 January 2017 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6028787
11 January 2016 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5796070
16 September 2015 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5720192
11 March 2014 Deadweight Survey · Annual Inspection · Plan Review "T" Boat · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4813809
3 January 2012 DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4217255
9 September 2011 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4139909
3 January 2011 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3919745
2 March 2010 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3688288
7 January 2010 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3660468
6 January 2009 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3389772
9 January 2008 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3126932
5 September 2007 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3048069
29 July 2007 Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 3011135
5 January 2007 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2850396
12 January 2006 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2566836
15 September 2005 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2493053
27 January 2005 Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2280718
3 August 2004 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2146766
8 January 2004 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1970889
7 January 2003 Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1724271
12 September 2002 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1671026
8 January 2002 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1475441
21 March 2001 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1373155
5 January 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1405089
20 September 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1427893
6 January 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1458727
7 January 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1399131
11 September 1998 Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1432033
8 January 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468419
25 July 1997 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 780984
16 January 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1375083
5 September 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1437155
8 January 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1080379
10 February 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1150256
20 January 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 835457
13 September 1994 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1180546
22 April 1994 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1167138
22 April 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 832603
15 September 1992 Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 936712
1 June 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 947195
1 May 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257114
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 937646
2 May 1991 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 918616
28 September 1990 Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 917237
19 June 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 924841
23 May 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1216924
2 May 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1221845
19 September 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 995850
14 July 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1352098
22 June 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1351941
3 May 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1347437
23 June 1988 Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1343324
3 May 1988 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1195893
23 February 1988 Hull Examination · Drydock Extension
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1351302
4 May 1987 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1026752
9 September 1986 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1313664
20 May 1986 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1305595
18 April 1986 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 999257
31 May 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 981635
24 October 1984 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 974521

Deficiency record · 230

05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 January 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 3 February 2026
Resolved 2 February 2026
Resolution: Received emailed photo evidence of valid FCC certificates.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 January 2026 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Three (03) wooden life float paddles were found split or broken. 46 CFR 180.175(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 2 February 2026
Resolution: Received emailed photo evidence of 03 new paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 January 2026 Resolved
At least one ring life buoy must be fitted with a floating waterlight. Vessel's ring life buoy waterlight (port forward location) did not work. 46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 2 February 2026
Resolution: Received emailed photo evidence of working light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 January 2026 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. 46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 2 February 2026
Resolution: Received emailed photo evidence of properly marked ring life buoy.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 January 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. (ISO 18813:2006 Standards) Vessel's first-aid kit had expired and incomplete contents. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 2 February 2026
Resolution: Received emailed photo evidence of approved type first-aid kit on board.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 January 2025 Resolved
A serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Inspector observed expired alcohol test strips on board. 46 CFR 185.212 ; 701C
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2025
Resolved 14 January 2025
Resolution: New alcohol test strips were witnessed onboard and placed in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 January 2025 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Inspector observed port and starboard aft compartments did not have visual and audible alarm. 46 CFR 182.530(a)(1) ; 701C
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2025
Resolved 13 January 2025
Resolution: Received video evidence of all visual and audible alarms working as required. Resolved deficiency on this date.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 13 January 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio Beacon (EPIRB) installations, as set forth in 47 CFR part 80. Inspector observed expired EPIRB battery and additional EPIRB not registered with NOAA. Rectify w/in 7 days. 46 CFR 184.502 ; 705C
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 January 2025
Resolved 16 January 2025
Resolution: EPIRB was registered with NOAA
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 January 2025 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Inspector observed one paddle broken, 01 light out, & retro tape degraded. 46 CFR 180.175 (d) ; 16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 16 January 2025
Resolution: Float light was repaired and working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 January 2025 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. Inspector observed protective guard for belts on port MDE not attached. 46 CFR 176.402 ; 50C
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 16 January 2025
Resolution: Belt guard was properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2025 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Inspector observed lagging not secured on exhaust. 46 CFR 177.970 ; 50C
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 16 January 2025
Resolution: New lagging was installed on the exposed portions of the exhaust piping.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 January 2025 Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. Inspector observed temporary cord used to power ventilation fans. Remove fans or install permanent wires for equipment. 46 CFR 183.340 (r) ; 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 16 January 2025
Resolution: Extension cords were removed and fans were plugged directly into outlets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 January 2024 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: "Emergency Exit, Keep Clear". MI observed the engine room escape hatch cable and stenciling (topside) need to be replaced. 46 CFR 185.30-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 1 February 2024
Resolution: Vessel replaced cable and re-did stenciling for engine room escape hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 January 2024 Resolved
The float-free link must be secured to the painter at one end and secured to the vessel on the other end. MI observed two life float I-bolts must be replaced due to severe corrosion and do allow the life float to be secured to the vessel. Passenger count reduced by 24 until deficiency rectified. 46 CFR 180.20-1(1)(iii)
Action required: 705 - Other - as specified
Due 29 January 2024
Resolved 1 February 2024
Resolution: Vessel replaced both I-bolts. Passenger count is no longer reduced by 24.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 January 2024 Resolved
Each life float shall be fitted with a life line and shall be equipped with two paddles, a water light and a painter. MI observed four port and two starboard life float painters must be replaced due to deterioration. 46 CFR 180.15-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 1 February 2024
Resolution: Vessel provided pictures of new painter lines for life floats.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 September 2023 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel shall install system to the satisfaction of attending USCG Marine Inspector. 46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 29 January 2024
Resolution: MI observed all detectors worked after one detector in accommodation space was set off with smoke.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 September 2023 Resolved
Flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Vessel shall develop plan to the satisfaction of attending USCG Marine Inspector. 46 CFR 185.364
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 29 January 2024
Resolution: MI observed laminated posters on inside of vessel to ensure rechargeable lithium ion batteries are in spot at all times.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 January 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts, U.S. Coast Pilot, and Coast Guard Light List. Vessels charts, U.S. Coast Pilot, and Coast Guard Light List were all out of date, and not corrected. 46 CFR 184.420(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2022
Resolved 7 February 2022
Resolution: Attended vessel and verified up to date charts, coast pilot, and light list.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 01 life jacket was found to be torn, and not in serviceable condition. Passenger count reduced by 1. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Due 10 January 2022
Resolved 21 January 2022
Resolution: Vessel replaced life jacket with a new one.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 January 2022 Resolved
All cable and wire must not be installed with sharp bends. The cables connecting the port sider generator to the battery were installed with sharp bends coming off the terminal of the battery 46 CFR 183.340(b)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 21 January 2022
Resolution: Vessel re-routed the wiring to the battery to remove the sharp bend.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 January 2022 Resolved
All cable and wire must be installed with metal support spaced not more than 24 inches apart and in such a manner as to avoid chafing and other damage. The cable going to the transducer in the starboard side #2 hull compartment was not supported in any way and was lying across the deck. 46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 21 January 2022
Resolution: Vessel added support bracket for the wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2022 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. The remote fuel shutoff valves were not marked. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 21 January 2022
Resolution: Vessel marked the Fuel shutoff valves.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 January 2022 Resolved
The Emergency check-off list shall contain not less than the applicable portions of the "recommended Emergency Checkoff List", 185.25-5. Cut off air supply to fire- close hatches, ports, doors, and ventilators, etc. Vessels vent covers for the engine room did not fit snugly over the vent openings and did not cut off the air supply. 46 CFR 185.25-1(b)(Old-T) 46 CFR 185.25-5(c)(1)(Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 21 January 2022
Resolution: Vessel re-engineered how the vent covers are secured to the vent openings, and they now fit properly.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 January 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. The hull plating in the port side lazaret space was found to have 1/8th inch pitting on the centerline between the forward transverse frame 1 and 2. Resolve at the 2022 dry dock scheduled for the fall of 2022. 46 CFR 177.01-5 (Old-T)
Action required: 705 - Other - as specified
Due 30 November 2022
Resolved 4 October 2023
Resolution: Received photo of repaired pitting from vessel rep.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 January 2021 Resolved
Crop and renew fractured welds found on bottom plate stiffners located in compartment #2, port side, at the weld to the collision bulkhead. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 3 February 2021
Resolution: The operator contracted a third party welder to crop the existing weld and renew as original. Visually inspected weld; all sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 January 2021 Resolved
Crop and renew pitting, measuring 1/8" in depth or more, found on side shell plate in port/stbd compartment #2. Pitting located on the inboard side of the hull. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 3 February 2021
Resolution: The operator contracted a third party welder to grind the pitting, weld, and grind flush. The operator will monitor area until next credit dry dock. The side shell plate appeared satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 19 January 2021 Resolved
Identified corroded thru hull valve (positive shut off valve) handle in the lazarette. Replace thru hull valve handle in lazarette. 46 CFR 182.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 3 February 2021
Resolution: The operator replaced the corroded valve handle. Witnessed the operator cycle the valve from inside the space.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 19 January 2021 Resolved
A self propelled vessel of 65 feet or more in length engaged in commercial service shall carry a class A or class B AIS device. 33 CFR 164.46 (b)(1)and (2)
Action required: 705 - Other - as specified
Due 3 March 2021
Resolved 24 February 2021
Resolution: The operator installed a class A AIS unit at the operating station. Verified functionality of equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 January 2021 Resolved
Each vessel that operates on an oceans route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Each vessel certificated to operate on a coastwise route within 3 miles of land must either be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board or meet the standard for collision bulkheads and be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board and have onboard a type 1 406 Mhz EPIRB. Each vessel certificated to operate on a limited coastwise route must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. Found three 12 person life floats with decayed passenger nets. Renew life floats in accordance with manufacturer specifications and Coast Guard guidance. Total persons onboard on oceans routes reduced to 63 persons. 46 CFR 180.202(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 17 February 2021
Resolution: The operator ordered Q spec netting from the approved manufacturer in California. The operator installed the netting and placed all three life floats back into service.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 January 2020 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at pump outlet. The pump outlet shall be fitted with a pressure gage. During inspection Marine Inspector witnessed faulty pressure gauge on fire pump. Replace pressure gauge on outlet side of fire pump. 46 CFR 181.10-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 21 January 2020
Resolution: Gauge installed and fire pump tested at 60 psi, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 January 2020 Resolved
Propulsion machinery shall be capable of operating at constant marine load under such requirements without exceeding its design limitations. During inspection, Marine Inspector identified starboard generator fuel hose having deep cut/groove. Replace starboard generator fuel hose with same type hose or J-1942 or equivalent. 46 CFR 182.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 21 January 2020
Resolution: Vessel o/o replaced fuel line with J-1942 hose. Tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 13 January 2020 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1 inch letters, "EMERGENCY EXIT, KEEP CLEAR". During inspection, Marine Inspector witnessed lack of required markings on engine room emergency exits. Mark all emergency exits with proper markings. 46 CFR 185.30-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 21 January 2020
Resolution: Vessel o/o stenciled both sides of port and starboard engineroom emergency exits.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 January 2020 Resolved
On a vessel on which the number of passengers permitted on the upper decks is limited by stability criteria, as indicated by the vessels stability letter, the max number of passengers allowed on the upper decks must be indicated by a durable marking of numbers and letters at least one inch in height at the entranceway to each such deck. During inspection, Marine Inspector identified lack of required markings leading to upper deck indicating max number of passengers allowed. Provide correct marking to indicate max number of passengers allowed on upper deck. 46 CFR 185.30-3(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 21 January 2020
Resolution: Vessel o/o stenciled max pax count on ladderwell to upper deck.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 February 2019 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The gauge at the pump outlet read 45 PSI during the test witnessed by the Marine Inspector. Verify proper operations to the required 60 PSI. 46CFR181.10-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 15 February 2019
Resolution: Operator replaced guage; witnessed proper operation of fire pump.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 February 2019 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. The watertight door located in the starboard side, under deck void forward of the diesel tanks was in bad repair. The gasket surrounding the door has past its useful life and is no longer creating a watertight seal on the knifes edge. Additionally the top and bottom dogs were no longer touching the backing plate on the door opening and need to be adjusted to allow for a tight seal on the door. 46CFR171.114(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator adjusted door closures; verified proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 February 2019 Resolved
The lifeline and pendants must be as furnished by the manufacturer with the approved life float. The pendants on two life floats located on the starboard side of the top deck of the vessel is loosing it strength and becoming brittle. Replace each pendants on these two life floats according to manufacturer requirements. 46CFR180.175(f)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator replaced pendants.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 February 2019 Resolved
A vessel of more than 65 feet in length must have at least one fire axe located in or adjacent to the primary operating station. The fire axe's mounting location has been damaged and can no longer hold the axe. Replace. 46CFR181.600
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator replaced axe mounting bracket.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2019 Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46CFR4.06. Alcohol test strips provided by ASAP used for testing within 2 hours of a serious marine incident are expired. Replace. 46CFR16.240
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator replaced expired testing devices.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 February 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The first-aid kit on board did not meet requirements listed. Replace. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator replaced first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 February 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; Coast Guard Light List; and Tide tables. The vessel had outdated publications. Replace with current. Additionally extracts from the publications for the areas to be transited my be used instead of the complete publication. 46CFR184.420(a)(2),(3), and (4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator updated required publications.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 4 February 2019 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. The number of passengers allowed on the top deck has been removed due to repairs conducted and is no longer readable. 46CFR185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator labeled upper deck capacity.
Construction/Loadline › Structures › Superstructure
Issued 8 January 2018 Resolved
Permanently repair crack welds on P/S above aft door. 46CFR 176.802(a)(3)
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Resolution: Crack welds were properly ground and re-welded.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 January 2018 Resolved
Provide technician's report of proper install/operation of VHF-DSC distress call button. IAW MSIB 15-15. 46CFR184.25-1(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 9 January 2018
Resolution: Received tech report of proper install/operation.
Lifesaving › Lifefloat › Serviceable
Issued 8 January 2018 Resolved
Provide (1) 12 man life float to replace damaged life float. Until then passenger count on COI is reduced to 87.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 17 January 2018
Resolution: New (12) man life float installed. Passenger count re-instated to 99.
Stability › Watertight Integrity › General
Issued 6 September 2017 Resolved
Repair/replace thru-hull ball valves at bottom of hull on port and starboard lazarette for MSD. Currently frozen in position. 46CFR176.25-10(a)(6)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 18 September 2017
Resolution: received video confirmation of proper operation of ball valves
Engineering › Bilge Water Management System › Hose
Issued 6 September 2017 Resolved
Make permanent repairs to wasted bilge piping on stbd manifold overboard discharge pipe. Replace temp repair of flexible hose with fixed piping. 46CFR 182.40-1 (a)(3)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 18 September 2017
Resolution: Piping was replaced with hard piping.
Engineering › Non-conventional Propulsion/Steering › Hydraulic Steering Cylinder (jet)
Issued 17 January 2017 Resolved
Repair and prove proper operation of stbd hydraulic steering ram. 46 CFR 182.610(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2017
Resolved 18 January 2017
Resolution: Satisfactory completed repair of stbd hydraulic steering ram.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 January 2017 Resolved
Prove proper service of galley portable fire extinguisher (B-II). 46 CFR 181.301(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2017
Resolved 18 January 2017
Resolution: Provided portable fire extinguisher to the satisfaction of the Marine Inspector.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 January 2017 Resolved
Provide 05 life jackets in good service condition. 46 CFR 180.25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 7 February 2017
Resolution: Provided 05 Adult life jackets.
Lifesaving › Lifefloat › Quantity
Issued 17 January 2017 Resolved
Provide 01 life float for 12 people in good service condition. 46 CFR 180.10-5(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 17 February 2017
Resolution: Life float was replaced.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 17 January 2017 Resolved
Repair 02 fractured welds inboard of port engine frame. 46 CFR 176.25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 February 2017
Resolution: Welds were ground out and re-welded.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 January 2017 Resolved
Provide appropriate cover for breaker in galley with proper label. 46 CF 183.330
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 18 January 2017
Resolution: Appropriate cover and label provided to the satisfaction of the Marine Inspector.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 17 January 2017 Resolved
Provide evidence of current FCC Bridge to Bridge certificate. 47 CFR 80
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 18 January 2017
Resolution: Evidence of current Bridge to Bridge certificate provided to the satisfaction of the Marine Inspector.
Stability › Watertight Integrity › General
Issued 17 January 2017 Resolved
Repair/replace dog on watertight hatch on portside lazerette. 46 CFR 174.360
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 February 2017
Resolution: The hatch dog was replaced and in working condition.
Stability › Watertight Integrity › General
Issued 17 January 2017 Resolved
Install capture chains on port and stbd watertight hatches. 46 CFR 174.360
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 18 January 2017
Resolution: Capture chains installed on port and stbd watertight hatches to the satisfaction of the Marine Inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 January 2016 Resolved
One B-II fire extinguisher has not been serviced and is not charged. Needs to be serviced or replaced. 46CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2016
Resolution: The extinguisher was serviced
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 11 January 2016 Resolved
01 life jacket light is missing. Vessel is restricted to 98 passengers for 104 total persons when exceeding 20NM from a harbor of safe refuge. 46CFR 180.75
Due 25 January 2016
Resolved 11 January 2016
Resolution: Missing light was found and re-attached to life jacket.
Construction/Loadline › Structures › Scuttle
Issued 17 September 2015 Resolved
Repair crack on starboard side lazarette hatch. 46 CFR 176.610
Due 1 October 2015
Resolved 29 September 2015
Resolution: Welding complete.
Construction/Loadline › Hull › Bottom Plating
Issued 17 September 2015 Resolved
Make hole watertight inboard side of starboard void forward of ladderwell. 46 CFR 176.610
Due 1 October 2015
Resolved 29 September 2015
Resolution: Welding complete.
Construction/Loadline › Hull › Transverse Frame
Issued 17 September 2015 Resolved
Repair crack longitudinal frame in the forward port compartment. 46 CFR 176.610
Due 1 October 2015
Resolved 29 September 2015
Resolution: Insert installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 September 2015 Resolved
Reduce rail courses on vessel embarkation area. 46 CFR 177.35-1 (b)
Due 1 October 2015
Resolved 29 September 2015
Resolution: Installed
Electrical › Electric Supply System (service) › Cable
Issued 11 March 2014 Resolved
Ensure there are no dead head wires throughout vessel.
Action required: 705 - Other - as specified
Due 19 May 2014
Resolved 15 May 2014
Resolution: Owner removed dead head wires.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 11 March 2014 Resolved
Replace expired EPIRB battery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2014
Resolution: EPIRB battery was replaced.
Lifesaving › Lifefloat › Float-free Link
Issued 11 March 2014 Resolved
Replace spent weak link on life float.
Action required: 705 - Other - as specified
Due 19 May 2014
Resolved 15 May 2014
Resolution: Broken weak link was replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 March 2014 Resolved
Replace battery in floating water light for life float.
Action required: 705 - Other - as specified
Due 19 May 2014
Resolved 15 May 2014
Resolution: Battery in floating water light was replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 March 2014 Resolved
Provide annual test on galley fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2014
Resolution: Fire extinguisher was properly serviced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 March 2014 Resolved
Provide ammonia inhalants to be included in first aid kit.
Action required: 705 - Other - as specified
Due 19 May 2014
Resolved 15 May 2014
Resolution: Vessel provided new ammonia inhalants.
Navigation › Piloting/Steering › Marine Charts
Issued 11 March 2014 Resolved
Provide new chart or update existing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2014
Resolution: Vessel provided new, up to date charts.
Communications › Audible Communications › Horn/Whistle
Issued 11 March 2014 Resolved
Ensure horn is in working condition.
Action required: 705 - Other - as specified
Due 19 May 2014
Resolved 15 May 2014
Resolution: Owner repaired horn
Navigation › Piloting/Steering › Gyro Compass
Issued 11 March 2014 Resolved
Ensure compass is capable of illuminating.
Action required: 705 - Other - as specified
Due 19 May 2014
Resolved 15 May 2014
Resolution: Owner replaced compass light.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 3 January 2012 Resolved
06 Children's lifejackets condemned. POC to replace IAW 46CFR180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 January 2012
Resolution: Owner provided receipt of ordered new lifejackets. Had 3 extras on hand. Will run with 02 less children until others arrive.
Fire Fighting › Fire Pumps › Arrangement
Issued 3 January 2012 Resolved
Found rusted and failing fire pump bracket in Stbd Engine Room. Replace IAW46CFR181.300.
Condition: Improper/Lack of Maintenance
Due 3 February 2012
Resolved 7 February 2012
Resolution: Replaced pump bracket. Picture in local vsl folder.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 January 2012 Resolved
Properly dead end two wires on No. 3 engine. IAW 46CFR176.806(a)
Condition: Improper/Lack of Maintenance
Due 3 February 2012
Resolved 7 February 2012
Resolution: Properly dead ended all wires with permanent type connections.
Engineering › Fuel Oil Service System › Filter
Issued 3 January 2012 Resolved
Replace secondary fuel filter gasket on No. 2 engine. IAW 46CFR176.804(d)
Condition: Improper/Lack of Maintenance
Due 10 January 2012
Resolved 7 February 2012
Resolution: Replaced with new gasket.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 January 2012 Resolved
Replace anti-chaffing on wire bundles in engine rm compartment, and replace wire shielding for starter on No. 4 engine. IAW 46CFR176.806
Condition: Improper/Lack of Maintenance
Due 3 February 2012
Resolved 7 February 2012
Resolution: Replaced anti-chafing and replaced shielding on wire bundles.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 3 January 2011 Resolved
Provide valid Bridge to Bridge Radiotelephony Certificate as per 46 CFR 184.502
Due 10 January 2011
Resolved 10 January 2011
Resolution: Received valid Vessel Bridge to Bridge Radiotelephony Certificate.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 January 2011 Resolved
Repair/replace 5 waterlights as per 46 CFR 180.175(f)(4)
Due 10 January 2011
Resolved 6 January 2011
Resolution: Bill for 5 ordered and delivered waterlights was faxed to our office and corroberated.
Lifesaving › Liferaft Equipment › Instructions (survival)
Issued 3 January 2011 Resolved
Provide manufacturer's instructions for survival craft as per 46 CFR 185.702
Due 10 January 2011
Resolved 10 January 2011
Resolution: Received lifefloat inspection pointsILO manufacturer instructions as the manufacturer does not supply an inspection instructional manual.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 January 2011 Resolved
Provide proof of complete first-aid kit as per CFR 46 CFR 160.041
Due 10 January 2011
Resolved 19 January 2011
Resolution: Received receipt for Coast Guard approved first-aid kit that has already been delivered to the vessel.
Stability › Watertight Integrity › General
Issued 3 January 2011 Resolved
Provide proof port and stbd forepeak are watertight as per 46 CFR 179.212
Due 3 February 2011
Resolved 12 January 2011
Resolution: Received pictures and receipt for 2 replaced hatch covers.
Lifesaving › Lifefloat › Serviceable
Issued 3 January 2011 Resolved
Provide proposal for repair of lifefloats as per 46 CFR 180-175(d)
Due 3 February 2011
Resolved 10 January 2011
Resolution: Received repair proposal.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 3 January 2011 Resolved
Provide proof of 36" X 36" platform attached to rescue ladder in place of deteriorated rescue platform as per local policy.
Due 3 February 2011
Resolved 15 February 2011
Resolution: Master e-mailed pictures of resue platform installed on vessel.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 3 January 2011 Resolved
Replace smoke detector with approved UL217 type as per 46 CFR 181.450(a)(1)
Due 10 January 2011
Resolved 13 January 2011
Resolution: Received recept for UL approved smoke detector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 January 2011 Resolved
Properly dead-end or remove all hanging wires in port and stbd engine rooms as per 46 CFR 183.01-15 (old T).
Due 10 January 2011
Resolved 6 January 2011
Resolution: Master removed all dead-ended wires to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 January 2011 Resolved
Replace romex cable with boat cable as per 46 CFR 183.01-15.
Due 10 January 2011
Resolved 10 January 2011
Resolution: Romex cable removed as it was old wiring for a piece of equipment no lnger on-board.
Navigation › Piloting/Steering › Marine Charts
Issued 3 January 2011 Resolved
Provide current charts as per 46 CFR 184.420.
Due 10 January 2011
Resolved 6 January 2011
Resolution: Received receipt for new nautical charts.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 January 2011 Resolved
Afix wires with mettalic band clamps every 24" in engine room as per 46 CFR 111.60 (b)(5)
Due 10 January 2011
Resolved 12 January 2011
Resolution: Received pictures of referenced wiring afixed to overhead with metallic band clamps.
Construction/Loadline › Penetrations › Weld
Issued 3 January 2011 Resolved
Drill stop cracked welds in way of tonnage door and provide marine architect proposal for permanent repairs for next dry dock period as per 46 CFR 182.20-30 (b).
Due 3 February 2011
Resolved 7 January 2011
Resolution: [name withheld] determined the cracks in the bulkhead were most likely the result of poor welds. The Master will have the area rewelded at the next dry-dock period as the cracks do not impede the structural integrity of the vessel in any way.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 January 2011 Resolved
Repair/replace port engine room bilge alarm as per 46 CFR 182.530.
Due 10 January 2011
Resolved 3 January 2011
Resolution: Receipt for new bilge alarm was faxed to our office and corroberated.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 3 January 2011 Resolved
Make temporary repairs to seal stbd fuel tank fill tube at tank top and provide proposal for permanent repairs at next dry dock period as per 46 CFR 182.20-30(b).
Due 10 January 2011
Resolved 16 February 2011
Resolution: [name withheld] visited this vessel today and deemed the repairs made to the fuel tank sufficient. The Master will continue to closely monitor the fuel tank.
Construction/Loadline › Structures › Door
Issued 3 January 2011 Resolved
Properly label emergency exits as per 46 CFR 185.606.
Due 10 January 2011
Resolved 12 January 2011
Resolution: Received pictures of emergency exits being labelled IAW our instructions.
Lifesaving › Lifefloat › Netting
Issued 7 January 2010 Resolved
Replace nets on (3) lifefloats. Passenger count is reduced to 69 passengers and 3 crew until netting has been properly installed and cleared by CG.
Action required: 705 - Other - as specified
Resolved 22 January 2010
Resolution: Rcvd photos of nets replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 January 2010 Resolved
Replace batteries in (2) water lights on life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2010
Resolution: Rcvd fax of receipt for batteries.
Stability › Watertight Integrity › General
Issued 7 January 2010 Resolved
Replace (plug or cap) through bulkhead pipe leading from stbd engine room to steering compartment.
Action required: 705 - Other - as specified
Due 7 February 2010
Resolved 22 January 2010
Resolution: Rcvd digital photos of repair. Pipe was cut and replaced with a bolt and rubber washers on each side.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 January 2010 Resolved
Replace cracked florescent light covers port and stbd engine rooms.
Action required: 705 - Other - as specified
Due 7 February 2010
Resolved 25 January 2010
Engineering › Fuel Oil Service System › Valve, Control
Issued 7 January 2010 Resolved
Properly attach reach rod to the fwd stbd emergency fuel shut off valve. Plastic wire ties unacceptable.
Action required: 705 - Other - as specified
Due 7 February 2010
Resolved 12 January 2010
Resolution: Attached with screws.
Stability › Watertight Integrity › General
Issued 7 January 2010 Resolved
Replace union nut on bilge piping bulkhead penetration stuffing box located fwd void port side.
Action required: 705 - Other - as specified
Due 7 February 2010
Resolved 12 January 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 January 2010 Resolved
Replace broken window in port side head (male).
Action required: 705 - Other - as specified
Due 7 February 2010
Resolved 12 January 2010
Navigation › Piloting/Steering › Marine Charts
Issued 7 January 2010 Resolved
Provide current and corrected charts and pubs.
Action required: 705 - Other - as specified
Due 7 February 2010
Resolved 25 January 2010
Lifesaving › Visual Distress Signals (General) › Expired
Issued 6 January 2009 Resolved
Provide (6) six red hand flares and (6) six orange smoke signals or equivalent.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 6 January 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 January 2009 Resolved
Provide a total of 105 adult life jackets - type I CG approved. A total of 67 was destroyed and 35 new ones were added for a total of 73 on board vessel currently.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 8 January 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 January 2009 Resolved
Provide a total of 11 child size Type I CG approved life jackets. Two (2) were destroyed, with a total of (9) nine on board currently.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 8 January 2009
Electrical › Electrical Distribution System (service) › Switchboard
Issued 6 January 2009 Resolved
Label electrical panels at operating station and in the galley.
Action required: 705 - Other - as specified
Due 6 January 2009
Resolved 8 January 2009
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 6 January 2009 Resolved
Provide current and corrected charts for areas of operation.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 6 February 2009
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 6 January 2009 Resolved
Provide verticle philament bulbs/lamps for both port and starboard navigation lights.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 8 January 2009
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 6 January 2009 Resolved
Provide MF & HF communications.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 9 January 2009
Communications › Radio Communications › EPIRB
Issued 9 January 2008 Resolved
REPAIR/REPLACE EPIRB.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2008
Resolution: POC purchased a new EPIRB and a fax copy of the new NOAA registration was rcvd.
Lifesaving › Lifefloat › Float-free Link
Issued 9 January 2008 Resolved
REPLACE WEAK LINK ON LIFEFLOAT.
Condition: Placed in Improper Service
Due 16 January 2008
Resolved 14 January 2008
Resolution: Weak link was replaced.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 9 January 2008 Resolved
VESSEL IS RESTRICTED TO NO MORE THAN 20 MILES UNTIL LIGHTS ON LIFE JACKETS ARE REPLACED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 January 2008
Resolution: New lights were purchased and installed.
Engineering › Reduction Gearing/Clutches › Casing
Issued 9 January 2008 Resolved
REPAIR L/O LEAKS ON BOTH STBD AND PORT MAIN REDUCTION GEARS.
Due 23 January 2008
Resolved 14 January 2008
Resolution: Leaks were repaired after replacing the o-rings.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 9 January 2008 Resolved
REPAIR L/O LEAKS ON STBD OUTBOARD MAIN ENGINE.
Due 23 January 2008
Resolved 14 January 2008
Resolution: New hoses and fittings were installed.
Engineering › Fuel Oil Service System › Hose
Issued 9 January 2008 Resolved
REPLACE FUEL HOSES FOR STBD ENGINE ROOM SUPPLY.
Due 16 January 2008
Resolved 14 January 2008
Resolution: New hoses were purchased and installed.
Electrical › Electric Supply System (service) › Cable
Issued 9 January 2008 Resolved
REMOVE DEAD ENDED CABLES FOR EXISTING VOLTAGE REGULATORS.
Due 23 January 2008
Resolved 14 January 2008
Resolution: Electrical cables were removed.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 January 2008 Resolved
VESSEL IS RESTRICTED TO NO MORE THAN 20 MILES UNTIL REPAIRS ARE MADE TO THE MF RADIO AND A SUCCESSFUL RADIO CHK IS CONDUCTED WITH CG SECTOR ST PETERSBURG.
Action required: 705 - Other - as specified
Resolved 15 February 2008
Resolution: MF radio was sent to manufacture and repaired. Conducted radio check with Sector St Pete command center. Transmission was weak but readable.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 5 January 2007 Resolved
Provide EAP training as per 46 CFR 16.401 and document.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 5 January 2007
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 January 2007 Resolved
Provide alcohol test program and method of compliance, include training for master on use of kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2007
Resolved 5 January 2007
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 5 January 2007 Resolved
Provide proof of MIS report submittal for 2005.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 5 January 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 January 2007 Resolved
Provide summary of the 2006 tests conducted under chemical testing program.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 5 January 2007
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 5 January 2007 Resolved
Properly display EAP informational material as per 46 CFR 16.401 (a).
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 5 January 2007
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 5 January 2007 Resolved
Provide vesel with Local Notice to Mariners.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Lifesaving › Buoyant Apparatus › Marking
Issued 5 January 2007 Resolved
Stencil life floats as needed due to fading.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 5 January 2007 Resolved
Renew retroreflective tape for one life float.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 5 January 2007 Resolved
Properly attach the water lights to the body of the life floats.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 5 January 2007 Resolved
Secure sewage tank valves as per 33 CFR 159.7 (c).
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Engineering › Fuel Oil Service System › Hose
Issued 5 January 2007 Resolved
Renew supply fuel hoses in the engine rooms as discussed (2 port, 1 stbd) due to deterioration.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 5 January 2007 Resolved
Label the breakers in the panel under the sink in the galley.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 January 2007 Resolved
Renew expired items in the first aid kit.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 5 January 2007 Resolved
Remove the fuel from the bilge of the stbd aft hold and repair the vent pipe hose due to leakage.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 12 January 2006 Resolved
Provide a light cover for the range hood.
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 12 January 2006
Fire Fighting › Grease Extraction Hood › General
Issued 12 January 2006 Resolved
Provide a grease filter for the range hood.
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 12 January 2006
Construction/Loadline › Structures › Superstructure
Issued 12 January 2006 Resolved
Repair the broken window on the port side of the pilothouse.
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 12 January 2006
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 12 January 2006 Resolved
Provide a current Nav. Rules.
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 12 January 2006
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 12 January 2006 Resolved
Provide the vessel with the Local Notice to Mariners.
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 12 January 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 12 January 2006 Resolved
Service all fire extinguishers.
Action required: 705 - Other - as specified
Due 12 February 2006
Resolved 12 January 2006
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 12 January 2006 Resolved
At next dry dock paint draft marks.
Action required: 705 - Other - as specified
Due 3 August 2006
Resolved 20 September 2006
Documentation › Certificates/Documents › FCC SSL
Issued 27 January 2005 Resolved
Provide a copy of your Bridge-to-Bridge radiotelephony certificate which expired 08SEP99.
Condition: Improper/Lack of Maintenance
Due 27 February 2005
Resolved 17 February 2005
Documentation › Certificates/Documents › FCC SSL
Issued 27 January 2005 Resolved
Provide a copy or your FCC Safety Radiotelephony certificate which expired 03SEP04.
Condition: Improper/Lack of Maintenance
Due 27 February 2005
Resolved 17 February 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 January 2005 Resolved
Provide up-dated Nautical Publications IAW 46CFR185.20-35. (Charts, Coast Pilot [name withheld], Notices to Mariners, Tide Tables and Cyrrent Tables.
Condition: Improper/Lack of Maintenance
Due 10 February 2005
Resolved 17 February 2005
Lifesaving › Hand Flares › Expired
Issued 27 January 2005 Resolved
Prior to the carriage of passengers, provide 12 red hand held day/night flares and re-label container.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 27 January 2005
Electrical › Electric Supply System (service) › Cable
Issued 27 January 2005 Resolved
Remove wire nuts on PORT bilge pump electrical connection and make a solid connection.
Condition: Improper Installation
Due 10 February 2005
Resolved 17 February 2005
Communications › Radio Communications › EPIRB
Issued 27 January 2005 Resolved
Replace hydro-static release.
Condition: Improper/Lack of Maintenance
Due 31 January 2005
Resolved 17 February 2005
Fire Fighting › Fire Pumps › Pressure
Issued 27 January 2005 Resolved
Replace fire pump pressure gauge.
Condition: Improper/Lack of Maintenance
Due 27 February 2005
Resolved 17 February 2005
Lifesaving › Buoyant Apparatus › Marking
Issued 27 January 2005 Resolved
Re-label LF's with vsl's name and amunt as needed.
Condition: Improper/Lack of Maintenance
Due 27 February 2005
Resolved 17 February 2005
Lifesaving › Buoyant Apparatus › Approval
Issued 27 January 2005 Resolved
Prior to the carriage of passengers, provide 2 ring buoy's which one needs to be outfitted with a water light and 60 ft of line. Water light needs 3-6 ft lanyard with a clip as discussed.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 27 January 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 January 2005 Resolved
Update first aid kit.
Condition: Improper/Lack of Maintenance
Due 10 February 2005
Resolved 17 February 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 January 2005 Resolved
Provide 50% of crew with first-aid / CPR training.
Condition: Improper/Lack of Maintenance
Due 27 February 2005
Resolved 17 February 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 January 2005 Resolved
Label amount of life jackets in storage lockers.
Condition: Improper/Lack of Maintenance
Due 27 February 2005
Resolved 17 February 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 January 2005 Resolved
Prior to the carriage of passengers, provide a safety line for person assisting person OVBD.
Condition: Improper/Lack of Maintenance
Due 27 January 2005
Resolved 27 January 2005
Lifesaving › Buoyant Apparatus
Issued 7 January 2003 Resolved
Replace three(3) water lights on life floats. (1 on PORT, 2 on STBD) prior to the carriage of passengers. LEGACY COMPONENT DESC: Water Light
Condition: Improper/Lack of Maintenance
Due 7 January 2003
Resolved 9 January 2003
Lifesaving › Lifejacket/PFD (General)
Issued 7 January 2003 Resolved
Replace worn retro-reflective tape on life jackets as needed. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 21 January 2003
Resolved 9 January 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 7 January 2003 Resolved
Repair FWD, STBD fire extinguisher bracket. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper/Lack of Maintenance
Due 21 January 2003
Resolved 9 January 2003
Fire Fighting › Fire Hydrants
Issued 7 January 2003 Resolved
Replace valve handles on all fire station plugs prior to the carriage of passengers. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 7 January 2003
Resolved 9 January 2003
Engineering › Bilge Water Management System
Issued 7 January 2003 Resolved
Make bilge manifold labels readable. LEGACY COMPONENT DESC: Manifold labeling
Condition: Improper/Lack of Maintenance
Due 21 January 2003
Resolved 9 January 2003
Communications › Radio Communications
Issued 7 January 2003 Resolved
Replace hydrostatic release on EPIRB prior to the carriage of passengers. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 7 January 2003
Resolved 9 January 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 7 January 2003 Resolved
Move one portable fire extinguisher from inside each engine room, outside, by the entrances. LEGACY COMPONENT DESC: Location
Condition: Improper Installation
Due 21 January 2003
Resolved 9 January 2003
Lifesaving › Lifejacket/PFD (General)
Issued 7 January 2003 Resolved
Replace 3 life jacket lights prior to the carriage of passengers. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Due 7 January 2003
Resolved 9 January 2003
Accommodation/Occupational Safety
Issued 7 January 2002 Resolved
Post maximum number of passengers per stability letter. (24 persons allowed on upper deck)
Condition: Unknown
Due 14 January 2002
Resolved 8 January 2002
Navigation › Piloting/Steering
Issued 7 January 2002 Resolved
Replace the three hydraulic hoses on steering system as discussed. (2 STBD and 1 PORT)
Condition: Improper/Lack of Maintenance
Due 8 January 2002
Resolved 8 January 2002
Engineering › Bilge Water Management System › Pump
Issued 7 January 2002 Resolved
Repair PORT and STBD bilge pumps.
Condition: Improper/Lack of Maintenance
Due 8 January 2002
Resolved 8 January 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 January 2002 Resolved
Replace wasted retro-reflective tape on life jackets as needed
Condition: Improper/Lack of Maintenance
Due 14 January 2002
Resolved 8 January 2002
Lifesaving › Buoyant Apparatus
Issued 7 January 2002 Resolved
Properly label life ring, PORT side, AFT.
Condition: Improper/Lack of Maintenance
Due 14 January 2002
Resolved 8 January 2002
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 7 January 2002 Resolved
Remove discharge line from waste oil tank that goes OVBD.
Condition: Improper Installation
Due 8 January 2002
Resolved 8 January 2002
Accommodation/Occupational Safety › Ventilation
Issued 7 January 2002 Resolved
Prior to 20SEP02 (NEXT DRYDOCK), provide a 2 1/2 inch dia gooseneck vent for the PORT and STBD tank room IAW 46 CFR 182.20-50. LEGACY COMPONENT DESC: Fuel Tank Space (PORT & STBD)
Condition: Unknown
Due 20 September 2002
Resolved 12 September 2002
Resolution: VENTS INSTALLED.
Engineering › Bilge Water Management System › Interface Detector
Issued 7 January 2002 Resolved
Repair STBD, AFT high bilge water level alarm.
Condition: Improper/Lack of Maintenance
Due 8 January 2002
Resolved 8 January 2002
Lifesaving › Rigid Liferafts › Painter
Issued 4 January 2002 Resolved
Replace line from LF's to LF lights.
Condition: Improper/Lack of Maintenance
Due 14 January 2002
Resolved 8 January 2002
Lifesaving
Issued 21 March 2001 Resolved
Prior to carrying passenger on the upper deck, submit stability calculations for number of passengers desired on upper deck showing adequate reserve stability.
Condition: Unknown
Due 8 January 2002
Resolved 8 January 2002
Resolution: Vessel received a new stability test March 2001
Lifesaving
Issued 5 January 2001 Resolved
REPLACE LIGHTS ON LIFEJACKETS AS NEEDED.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Construction/Loadline
Issued 5 January 2001 Resolved
INSTALL VENT CLOSURES ON ENGINE ROOM AND STACK VENTS.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Fire Fighting
Issued 5 January 2001 Resolved
REPLACE 8" PIPE ON FIRE MAIN SYSEM IWO PUMP.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Engineering
Issued 5 January 2001 Resolved
INSTALL COMPRESSION FITTINGS IN FUEL LINE AT FUEL STRAINER AND GENSET.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Construction/Loadline
Issued 5 January 2001 Resolved
REPAIR HIGH LEVEL BILGE ALARMS IN LAZRETTE.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Engineering
Issued 5 January 2001 Resolved
INSTALL PLUGS ON FUEL SRAINERS.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Lifesaving
Issued 7 January 1999 Resolved
REPLACE BATTERIES FOR ALL (10) WATERLIGHTS AND ATTEST TO SATISFACTORY OPERATION OF SAME PRIOR TO CARRIAGE OF PASSENGERS AFTER SUNSET.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Documentation
Issued 8 January 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 January 1998
Resolved 21 January 1998
Engineering
Issued 8 January 1998 Resolved
RE-INSTALL PROTECTIVE COVERS OVER PROP SHAFTS AT LADDER BASE IN EACH ENGINEROOM.
Condition: Unknown
Due 15 January 1998
Resolved 21 January 1998
Lifesaving
Issued 8 January 1998 Resolved
FOR LIFEFLOATS: REPLACE MISSING RETAINING CLIPS; CONDUCT ANNUAL BATTERY CHANGE; REPAIR OR REPLACE FOUR PADDLES; AND, PROIR TO CARRIAGE OF MORE THAN96 TOTAL PERSONS ON AN OCEANS ROUTE, REPAIR OR REPLACE DAMAGED LENS ON 9TH LIFEFLOAT WATERLIGHT.
Condition: Unknown
Due 15 January 1998
Resolved 21 January 1998
Engineering
Issued 8 January 1998 Resolved
RE-STENCIL FUEL OIL SHUT-OFF VALVES.
Condition: Unknown
Due 15 January 1998
Resolved 21 January 1998
Navigation
Issued 20 January 1995 Resolved
Provide onboard current charts, light list and tide & current tables.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Accommodation/Occupational Safety
Issued 20 January 1995 Resolved
Replace broken windows back of pilot house.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Construction/Loadline
Issued 20 January 1995 Resolved
Repair port bilge pump.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Electrical
Issued 20 January 1995 Resolved
Relabel switches and breaker on panels in pilot house.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Engineering
Issued 20 January 1995 Resolved
Install guard over rotating machinery starboard generator.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Accommodation/Occupational Safety
Issued 20 January 1995 Resolved
Maintain daily garbage diposal log.
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Lifesaving
Issued 20 January 1995 Resolved
Repair or replace 1 waterlight.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Lifesaving
Issued 20 January 1995 Resolved
Replace 2 lifefloat paddles.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Lifesaving
Issued 20 January 1995 Resolved
Repair or replace 6 pfds lights.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Engineering
Issued 20 January 1995 Resolved
Replace flame screen starboard aft vent.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Engineering
Issued 15 September 1992 Resolved
Label emergency fuel shut off valves at fuel tank and to engines.
Condition: Unknown
Due 1 October 1992
Resolved 1 October 1992
Accommodation/Occupational Safety
Issued 15 September 1992 Resolved
Reconnect suction line from MSD holding tank to hand pump.
Condition: Unknown
Due 1 October 1992
Resolved 1 October 1992
Lifesaving
Issued 1 May 1992 Resolved
Permanently mount approved EPIRB. Vessel may not operate on oceans route until this requirement is cleared.
Condition: Unknown
Due 5 June 1992
Resolved 5 June 1992
Construction/Loadline
Issued 2 May 1991 Resolved
SECURE P & S ENGINE DECK HATCHES.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Deck/Cargo
Issued 2 May 1991 Resolved
PROVIDE ADEQUATE SUCTION AND DISCHARGE HOSES FOR PORTABLE BILGE PUMP.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
RENEW STBD OUTBOARD ENGINE SEA SUCTION HOSE.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Fire Fighting
Issued 2 May 1991 Resolved
PROVIDE 1 B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Accommodation/Occupational Safety
Issued 2 May 1991 Resolved
FPROVIDE CAPS FOR ALL VENTS.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
RENEW 7 LIFE FLOAT PAINTERS.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
REPAIR 2 LIFE FLOAT LIGHTS.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
INSTALL REFECTIVE TAPE, ALL LIFE FLOATS.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Deck/Cargo
Issued 2 May 1991 Resolved
REPAIR 2 ENGINE DRIVEN BILGE PUMPS.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Construction/Loadline
Issued 2 May 1991 Resolved
REPAIR 4 FRACTURES IN FRAMES JUST FWD OF PORT OUTBOARD RUDDER PRIOR TO NEXTDRYDOCK OR 28MAR92.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Engineering
Issued 2 May 1991 Resolved
INSTALL REMOTE CLOSING DEVICE FOR 4 FWD FUEL TANKS PRIOR TO NEXT DRYDOCK OR28MAR92.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Construction/Loadline
Issued 2 May 1991 Resolved
REPAIR 2 FRACTURES IN DECKHOUSE ABOVE TONNAGE OPENING. TO BE COMPLETED PRIOR TO NEXT DRYDOCK OR 28MAR92.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Construction/Loadline
Issued 2 May 1991 Resolved
REMOVE CAULKING - TONNAGE OPENING.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Fire Fighting
Issued 2 May 1991 Resolved
MOUNT B-I FIRE EXTINGUISHER IN PILOTHOUSE.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
PROVIDE 1 CHILD PFD.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
PROVIDE ALL PFD'S WITH NEW LIGHT BATTERIES.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
RENEW RING BUOY WITH LIGHT.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Deck/Cargo
Issued 28 September 1990 Resolved
CLEAN BILGE STRAINERS IN STEERING COMPARTMENTS.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Accommodation/Occupational Safety
Issued 28 September 1990 Resolved
LABEL REACH RODS FOR MSD HOLDING TANK OVERBOARD VALVES ON BULKHEAD MAINDECK"WARNING, DO NOT OPEN WHILE IN INLAND WATERS". DEMONSTRATE THE OPERTION OF THE VALVES.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Fire Fighting
Issued 28 September 1990 Resolved
RENEW THE STARBOARD FIRE MAIN PIPE FITTING ON MAIN DECK.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Construction/Loadline
Issued 28 September 1990 Resolved
CREDIT DRYDOCK DUE 28MAR92. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Engineering
Issued 28 September 1990 Resolved
RENEW OVERBOARD DISCHARGE VALVE ON OUTBOARD M/E PORT SIDE OR REPAIR VALVE HANDLE.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Construction/Loadline
Issued 28 September 1990 Resolved
VEE AND WELD BOTTOM FRAME FRACTURED WELDS WHERE MARKED IN PORT AND STBD COMPARTMENTS JUST AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Engineering
Issued 28 September 1990 Resolved
CLEAN MAIN ENGINE SEA SUCTION STRAINERS AND VALVES BODIES (4 TOTAL).
Condition: Unknown
Due 28 September 1990
Resolved 28 September 1990
Lifesaving
Issued 2 May 1990 Resolved
RENEW LINES TO WATERLIGHTS ON ALL 9 LIFEFLOATS WITH 18' LENGTHS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE A LADDER AND PLATFORM SUITABLE FOR RETRIEVING A PERSON FROM THE WATER.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
RENEW FLOAT-FREE LINKS ON 5 LIFEFLOATS WITH PROPER CAPACITY (11-20 PERSON)LINKS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990 Resolved
STENCIL BOTH EMERGENCY F/O SHUTOFF VALVES.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Documentation
Issued 19 September 1989 Resolved
CREDIT DRYDOCK DUE 19MAR91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 19 September 1989
Resolved 19 September 1989
Lifesaving
Issued 3 May 1989 Resolved
RENEW ALL LIFEFLOAT PADDLES, 18 TOTAL.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Construction/Loadline
Issued 3 May 1989 Resolved
PROVIDE WARNING INDICATOR DEVICES ON BOTH BELOW DECK WATERTIGHT DOORS WITH INDICATOR LIGHTS IN WHEELHOUSE TO TELL WHEN DOORS ARE OPEN.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Documentation
Issued 3 May 1989 Resolved
PROVIDE NEW RULES OF THE ROAD (NAVIGATION RULES) BOOK.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Navigation
Issued 3 May 1989 Resolved
REPAIR EPIRB, ROUTE REDUCED TO 20 MILES FROM LAND UNTIL COMPLETED.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Navigation
Issued 3 May 1989 Resolved
PROVIDE SHIP'S BELL (SIZE IAW NAVIGATION RULES) EITHER 10" OR 12".
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Lifesaving
Issued 3 May 1989 Resolved
PROVIDE 2 PFD LIGHTS OR REPAIR EXISTING, TOTAL NUMBER OF ADULT PASSENGERS IS REDUCED BY 2 UNTIL COMPLETED.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Construction/Loadline
Issued 3 May 1989 Resolved
STENCIL BOTH DOORS WITH "WARNING, KEEP CLOSED WHILE UNDERWAY".
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Fire Fighting
Issued 3 May 1988 Resolved
INSTALL APPROVED NOZZLE ON FIRE HOSES.
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988
Lifesaving
Issued 3 May 1988 Resolved
INSTALL LIGHTS ON CHILD LIFE PRESERVERS.
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988
Electrical
Issued 3 May 1988 Resolved
INSTALL JUNCTION BOX ON ELECTRICAL SPLICE TO GALLEY F.W. PUMP.
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988
Fire Fighting
Issued 3 May 1988 Resolved
INSTALL GAGE ON FIRE PUMP.
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988

Casualty record · 2

7 November 2018Routine · role: Involved in a Marine Casualty · activity 6580371
25 January 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7130430
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.