Records from 2016 to 2026. Most recent: inspection, 20 January 2026.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 January 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 3 February 2026
Resolved 2 February 2026
Resolution: Received emailed photo evidence of valid FCC certificates.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 January 2026
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Three (03) wooden life float paddles were found split or broken.
46 CFR 180.175(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 2 February 2026
Resolution: Received emailed photo evidence of 03 new paddles.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 January 2026
Resolved
At least one ring life buoy must be fitted with a floating waterlight. Vessel's ring life buoy waterlight (port forward location) did not work.
46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 2 February 2026
Resolution: Received emailed photo evidence of working light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 January 2026
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 2 February 2026
Resolution: Received emailed photo evidence of properly marked ring life buoy.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 January 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. (ISO 18813:2006 Standards)
Vessel's first-aid kit had expired and incomplete contents.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 2 February 2026
Resolution: Received emailed photo evidence of approved type first-aid kit on board.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 January 2025
Resolved
A serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Inspector observed expired alcohol test strips on board.
46 CFR 185.212 ; 701C
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2025
Resolved 14 January 2025
Resolution: New alcohol test strips were witnessed onboard and placed in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 January 2025
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Inspector observed port and starboard aft compartments did not have visual and audible alarm.
46 CFR 182.530(a)(1) ; 701C
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2025
Resolved 13 January 2025
Resolution: Received video evidence of all visual and audible alarms working as required. Resolved deficiency on this date.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 13 January 2025
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio Beacon (EPIRB) installations, as set forth in 47 CFR part 80. Inspector observed expired EPIRB battery and additional EPIRB not registered with NOAA. Rectify w/in 7 days.
46 CFR 184.502 ; 705C
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 January 2025
Resolved 16 January 2025
Resolution: EPIRB was registered with NOAA
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 January 2025
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Inspector observed one paddle broken, 01 light out, & retro tape degraded.
46 CFR 180.175 (d) ; 16C
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 16 January 2025
Resolution: Float light was repaired and working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 January 2025
Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. Inspector observed protective guard for belts on port MDE not attached.
46 CFR 176.402 ; 50C
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 16 January 2025
Resolution: Belt guard was properly mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2025
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Inspector observed lagging not secured on exhaust.
46 CFR 177.970 ; 50C
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 16 January 2025
Resolution: New lagging was installed on the exposed portions of the exhaust piping.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 January 2025
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. Inspector observed temporary cord used to power ventilation fans. Remove fans or install permanent wires for equipment.
46 CFR 183.340 (r) ; 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 16 January 2025
Resolution: Extension cords were removed and fans were plugged directly into outlets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 January 2024
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: "Emergency Exit, Keep Clear".
MI observed the engine room escape hatch cable and stenciling (topside) need to be replaced.
46 CFR 185.30-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 1 February 2024
Resolution: Vessel replaced cable and re-did stenciling for engine room escape hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 January 2024
Resolved
The float-free link must be secured to the painter at one end and secured to the vessel on the other end.
MI observed two life float I-bolts must be replaced due to severe corrosion and do allow the life float to be secured to the vessel.
Passenger count reduced by 24 until deficiency rectified.
46 CFR 180.20-1(1)(iii)
Action required: 705 - Other - as specified
Due 29 January 2024
Resolved 1 February 2024
Resolution: Vessel replaced both I-bolts. Passenger count is no longer reduced by 24.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 January 2024
Resolved
Each life float shall be fitted with a life line and shall be equipped with two paddles, a water light and a painter.
MI observed four port and two starboard life float painters must be replaced due to deterioration.
46 CFR 180.15-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 1 February 2024
Resolution: Vessel provided pictures of new painter lines for life floats.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 September 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces.
Vessel shall install system to the satisfaction of attending USCG Marine Inspector.
46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 29 January 2024
Resolution: MI observed all detectors worked after one detector in accommodation space was set off with smoke.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 September 2023
Resolved
Flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions.
Vessel shall develop plan to the satisfaction of attending USCG Marine Inspector.
46 CFR 185.364
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2023
Resolved 29 January 2024
Resolution: MI observed laminated posters on inside of vessel to ensure rechargeable lithium ion batteries are in spot at all times.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 January 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts, U.S. Coast Pilot, and Coast Guard Light List.
Vessels charts, U.S. Coast Pilot, and Coast Guard Light List were all out of date, and not corrected.
46 CFR 184.420(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2022
Resolved 7 February 2022
Resolution: Attended vessel and verified up to date charts, coast pilot, and light list.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
01 life jacket was found to be torn, and not in serviceable condition. Passenger count reduced by 1.
46 CFR 180.71(a)
Action required: 705 - Other - as specified
Due 10 January 2022
Resolved 21 January 2022
Resolution: Vessel replaced life jacket with a new one.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 January 2022
Resolved
All cable and wire must not be installed with sharp bends.
The cables connecting the port sider generator to the battery were installed with sharp bends coming off the terminal of the battery
46 CFR 183.340(b)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 21 January 2022
Resolution: Vessel re-routed the wiring to the battery to remove the sharp bend.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 January 2022
Resolved
All cable and wire must be installed with metal support spaced not more than 24 inches apart and in such a manner as to avoid chafing and other damage.
The cable going to the transducer in the starboard side #2 hull compartment was not supported in any way and was lying across the deck.
46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 21 January 2022
Resolution: Vessel added support bracket for the wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high
indicating purpose of the valve and direction of operation.
The remote fuel shutoff valves were not marked.
46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 21 January 2022
Resolution: Vessel marked the Fuel shutoff valves.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 January 2022
Resolved
The Emergency check-off list shall contain not less than the applicable portions of the "recommended Emergency Checkoff List", 185.25-5. Cut off air supply to fire- close hatches, ports, doors, and ventilators, etc.
Vessels vent covers for the engine room did not fit snugly over the vent openings and did not cut off the air supply.
46 CFR 185.25-1(b)(Old-T)
46 CFR 185.25-5(c)(1)(Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 21 January 2022
Resolution: Vessel re-engineered how the vent covers are secured to the vent openings, and they now fit properly.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 January 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with
the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
The hull plating in the port side lazaret space was found to have 1/8th inch pitting on the centerline between the forward transverse frame 1 and 2.
Resolve at the 2022 dry dock scheduled for the fall of 2022.
46 CFR 177.01-5 (Old-T)
Action required: 705 - Other - as specified
Due 30 November 2022
Resolved 4 October 2023
Resolution: Received photo of repaired pitting from vessel rep.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 January 2021
Resolved
Crop and renew fractured welds found on bottom plate stiffners located in compartment #2, port side, at the weld to the collision bulkhead.
46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 3 February 2021
Resolution: The operator contracted a third party welder to crop the existing weld and renew as original. Visually inspected weld; all sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 January 2021
Resolved
Crop and renew pitting, measuring 1/8" in depth or more, found on side shell plate in port/stbd compartment #2. Pitting located on the inboard side of the hull.
46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 3 February 2021
Resolution: The operator contracted a third party welder to grind the pitting, weld, and grind flush. The operator will monitor area until next credit dry dock. The side shell plate appeared satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 19 January 2021
Resolved
Identified corroded thru hull valve (positive shut off valve) handle in the lazarette. Replace thru hull valve handle in lazarette.
46 CFR 182.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 3 February 2021
Resolution: The operator replaced the corroded valve handle. Witnessed the operator cycle the valve from inside the space.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 19 January 2021
Resolved
A self propelled vessel of 65 feet or more in length engaged in commercial service shall carry a class A or class B AIS device. 33 CFR 164.46 (b)(1)and (2)
Action required: 705 - Other - as specified
Due 3 March 2021
Resolved 24 February 2021
Resolution: The operator installed a class A AIS unit at the operating station. Verified functionality of equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 January 2021
Resolved
Each vessel that operates on an oceans route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Each vessel certificated to operate on a coastwise route within 3 miles of land must either be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board or meet the standard for collision bulkheads and be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board and have onboard a type 1 406 Mhz EPIRB. Each vessel certificated to operate on a limited coastwise route must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board.
Found three 12 person life floats with decayed passenger nets. Renew life floats in accordance with manufacturer specifications and Coast Guard guidance. Total persons onboard on oceans routes reduced to 63 persons.
46 CFR 180.202(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2021
Resolved 17 February 2021
Resolution: The operator ordered Q spec netting from the approved manufacturer in California. The operator installed the netting and placed all three life floats back into service.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 January 2020
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at pump outlet. The pump outlet shall be fitted with a pressure gage.
During inspection Marine Inspector witnessed faulty pressure gauge on fire pump.
Replace pressure gauge on outlet side of fire pump.
46 CFR 181.10-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 21 January 2020
Resolution: Gauge installed and fire pump tested at 60 psi, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 January 2020
Resolved
Propulsion machinery shall be capable of operating at constant marine load under such requirements without exceeding its design limitations.
During inspection, Marine Inspector identified starboard generator fuel hose having deep cut/groove.
Replace starboard generator fuel hose with same type hose or J-1942 or equivalent.
46 CFR 182.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 21 January 2020
Resolution: Vessel o/o replaced fuel line with J-1942 hose. Tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 13 January 2020
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1 inch letters, "EMERGENCY EXIT, KEEP CLEAR".
During inspection, Marine Inspector witnessed lack of required markings on engine room emergency exits.
Mark all emergency exits with proper markings.
46 CFR 185.30-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 21 January 2020
Resolution: Vessel o/o stenciled both sides of port and starboard engineroom emergency exits.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 January 2020
Resolved
On a vessel on which the number of passengers permitted on the upper decks is limited by stability criteria, as indicated by the vessels stability letter, the max number of passengers allowed on the upper decks must be indicated by a durable marking of numbers and letters at least one inch in height at the entranceway to each such deck.
During inspection, Marine Inspector identified lack of required markings leading to upper deck indicating max number of passengers allowed.
Provide correct marking to indicate max number of passengers allowed on upper deck.
46 CFR 185.30-3(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 21 January 2020
Resolution: Vessel o/o stenciled max pax count on ladderwell to upper deck.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 February 2019
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The gauge at the pump outlet read 45 PSI during the test witnessed by the Marine Inspector. Verify proper operations to the required 60 PSI. 46CFR181.10-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 15 February 2019
Resolution: Operator replaced guage; witnessed proper operation of fire pump.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 February 2019
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. The watertight door located in the starboard side, under deck void forward of the diesel tanks was in bad repair. The gasket surrounding the door has past its useful life and is no longer creating a watertight seal on the knifes edge. Additionally the top and bottom dogs were no longer touching the backing plate on the door opening and need to be adjusted to allow for a tight seal on the door. 46CFR171.114(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator adjusted door closures; verified proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 February 2019
Resolved
The lifeline and pendants must be as furnished by the manufacturer with the approved life float. The pendants on two life floats located on the starboard side of the top deck of the vessel is loosing it strength and becoming brittle. Replace each pendants on these two life floats according to manufacturer requirements. 46CFR180.175(f)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator replaced pendants.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 February 2019
Resolved
A vessel of more than 65 feet in length must have at least one fire axe located in or adjacent to the primary operating station. The fire axe's mounting location has been damaged and can no longer hold the axe. Replace. 46CFR181.600
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator replaced axe mounting bracket.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2019
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46CFR4.06. Alcohol test strips provided by ASAP used for testing within 2 hours of a serious marine incident are expired. Replace. 46CFR16.240
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator replaced expired testing devices.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 February 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The first-aid kit on board did not meet requirements listed. Replace. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator replaced first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 February 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; Coast Guard Light List; and Tide tables. The vessel had outdated publications. Replace with current. Additionally extracts from the publications for the areas to be transited my be used instead of the complete publication. 46CFR184.420(a)(2),(3), and (4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator updated required publications.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 4 February 2019
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. The number of passengers allowed on the top deck has been removed due to repairs conducted and is no longer readable. 46CFR185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 13 February 2019
Resolution: Operator labeled upper deck capacity.
Construction/Loadline › Structures › Superstructure
Issued 8 January 2018
Resolved
Permanently repair crack welds on P/S above aft door. 46CFR 176.802(a)(3)
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 8 February 2018
Resolution: Crack welds were properly ground and re-welded.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 January 2018
Resolved
Provide technician's report of proper install/operation of VHF-DSC distress call button. IAW MSIB 15-15. 46CFR184.25-1(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 9 January 2018
Resolution: Received tech report of proper install/operation.
Lifesaving › Lifefloat › Serviceable
Issued 8 January 2018
Resolved
Provide (1) 12 man life float to replace damaged life float. Until then passenger count on COI is reduced to 87.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 February 2018
Resolved 17 January 2018
Resolution: New (12) man life float installed. Passenger count re-instated to 99.
Stability › Watertight Integrity › General
Issued 6 September 2017
Resolved
Repair/replace thru-hull ball valves at bottom of hull on port and starboard lazarette for MSD. Currently frozen in position. 46CFR176.25-10(a)(6)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 18 September 2017
Resolution: received video confirmation of proper operation of ball valves
Engineering › Bilge Water Management System › Hose
Issued 6 September 2017
Resolved
Make permanent repairs to wasted bilge piping on stbd manifold overboard discharge pipe. Replace temp repair of flexible hose with fixed piping. 46CFR 182.40-1 (a)(3)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 18 September 2017
Resolution: Piping was replaced with hard piping.
Engineering › Non-conventional Propulsion/Steering › Hydraulic Steering Cylinder (jet)
Issued 17 January 2017
Resolved
Repair and prove proper operation of stbd hydraulic steering ram. 46 CFR 182.610(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2017
Resolved 18 January 2017
Resolution: Satisfactory completed repair of stbd hydraulic steering ram.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 January 2017
Resolved
Prove proper service of galley portable fire extinguisher (B-II). 46 CFR 181.301(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 January 2017
Resolved 18 January 2017
Resolution: Provided portable fire extinguisher to the satisfaction of the Marine Inspector.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 January 2017
Resolved
Provide 05 life jackets in good service condition. 46 CFR 180.25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 7 February 2017
Resolution: Provided 05 Adult life jackets.
Lifesaving › Lifefloat › Quantity
Issued 17 January 2017
Resolved
Provide 01 life float for 12 people in good service condition. 46 CFR 180.10-5(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 17 February 2017
Resolution: Life float was replaced.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 17 January 2017
Resolved
Repair 02 fractured welds inboard of port engine frame. 46 CFR 176.25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 February 2017
Resolution: Welds were ground out and re-welded.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 January 2017
Resolved
Provide appropriate cover for breaker in galley with proper label. 46 CF 183.330
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 18 January 2017
Resolution: Appropriate cover and label provided to the satisfaction of the Marine Inspector.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 17 January 2017
Resolved
Provide evidence of current FCC Bridge to Bridge certificate. 47 CFR 80
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 18 January 2017
Resolution: Evidence of current Bridge to Bridge certificate provided to the satisfaction of the Marine Inspector.
Stability › Watertight Integrity › General
Issued 17 January 2017
Resolved
Repair/replace dog on watertight hatch on portside lazerette. 46 CFR 174.360
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 February 2017
Resolution: The hatch dog was replaced and in working condition.
Stability › Watertight Integrity › General
Issued 17 January 2017
Resolved
Install capture chains on port and stbd watertight hatches. 46 CFR 174.360
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 18 January 2017
Resolution: Capture chains installed on port and stbd watertight hatches to the satisfaction of the Marine Inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 January 2016
Resolved
One B-II fire extinguisher has not been serviced and is not charged. Needs to be serviced or replaced. 46CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 January 2016
Resolution: The extinguisher was serviced
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 11 January 2016
Resolved
01 life jacket light is missing. Vessel is restricted to 98 passengers for 104 total persons when exceeding 20NM from a harbor of safe refuge. 46CFR 180.75
Due 25 January 2016
Resolved 11 January 2016
Resolution: Missing light was found and re-attached to life jacket.