Records from 1981 to 1999. Most recent: inspection, 7 May 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
7 May 1999
Type not recorded
No type recorded · Station Fort Pierce · USCG Southeast District (CGD-SE) · Activity 1508704
23 January 1996
Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1186854
10 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880491
1 August 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 865393
28 July 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1173685
13 July 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 866030
17 February 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165102
13 April 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 833240
29 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1151877
30 January 1993
Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1148657
30 January 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405344
14 January 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 955796
26 June 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226195
17 January 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901200
7 August 1990
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1238959
2 March 1990
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223705
30 January 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1286602
3 February 1989
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349294
4 February 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1337986
3 April 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004552
21 August 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1035013
6 March 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998404
6 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982722
30 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280616
1 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284996
19 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275229
17 February 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1279239
17 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276392
Engineering
Issued 17 February 1994
Resolved
PROVE PROPER OPERATION OF THE STBD E/R EXHAUST FAN. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Engineering
Issued 17 February 1994
Resolved
REPLACE ALL 4 MDE LUBE OIL SENTINALS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Lifesaving
Issued 17 February 1994
Resolved
REPLACE 3 RUBBER HOSES WITH UNIONS ON THE STBD GEN SUCTION LINE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Documentation
Issued 17 February 1994
Resolved
PROVIDE 46 CFR 166 TO 199 AND COLREGS (RULES OF THE ROAD)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Navigation
Issued 17 February 1994
Resolved
REPAIR LIGHT FOR FATHOMETER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Deck/Cargo
Issued 17 February 1994
Resolved
REPAIR LEAK ON ANCHOR WINDLASS PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 17 February 1994
Resolved
PROVE PROPER OPERATION OF PORT MDE TACH INBOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Electrical
Issued 17 February 1994
Resolved
REPAIR STBD S/S GEN START SWITCH. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Engineering
Issued 30 March 1984
Resolved
HAVE COAST GUARD STAMP AND [name withheld] ON THE TWO ASME APPROVED S/S AIR RECEIVERS.
Condition: Unknown
Due 30 March 1984
Resolved 30 March 1984
Documentation
Issued 30 March 1984
Resolved
PROVIDE RESPONSE TO COMMENTS ON HULL PLAN REVIEW LETTER DATED 05JAN84 FROM COAST GUARD DISTRICT EIGHT MMT.
Condition: Unknown
Due 30 March 1984
Resolved 30 March 1984
Accommodation/Occupational Safety
Issued 30 March 1984
Resolved
MAKE SENAGE SYSTEM OPERABLE.
Condition: Unknown
Due 30 March 1984
Resolved 30 March 1984
Accommodation/Occupational Safety
Issued 30 March 1984
Resolved
PROVIDE LEVEL INDICATOR ON NEWLY INSTALLED SENAGE HOLDING TANK.
Condition: Unknown
Due 30 March 1984
Resolved 30 March 1984