Records from 1982 to 2012. Most recent: inspection, 18 May 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 55
18 May 2012
ORV Letter of Designation · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4315130
20 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4228565
23 February 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3950830
16 February 2011
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3946622
5 October 2010
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3864708
17 February 2010
Deficiency Check · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3679225
5 May 2009
Deficiency Check · Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3467666
4 June 2008
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3227045
6 June 2007
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2953210
27 April 2007
COI Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2916924
23 April 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2913484
16 April 2007
Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2909134
23 March 2007
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2893579
12 February 2007
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2870820
16 November 2005
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2531876
24 August 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2554552
1 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232332
21 July 2004
Re-Inspection · Internal Structural Exam · Damage Survey · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2140351
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2004032
24 November 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1953724
21 November 2003
Re-Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1949242
18 November 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1706644
4 March 2002
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1492388
19 October 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379604
10 October 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452724
1 March 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 766819
13 February 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 190285
19 October 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464230
1 April 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 787302
11 June 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877799
30 November 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422606
23 December 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431462
6 January 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399957
3 June 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 643827
3 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 62031
13 January 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395887
6 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213827
27 April 1992
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432605
6 February 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 955710
27 June 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 531864
23 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921608
18 April 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 457199
11 February 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 995265
8 November 1990
Damage Survey · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1221009
7 April 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 468368
5 March 1990
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923905
14 March 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 895172
16 March 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1029977
2 September 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002941
6 March 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016538
3 March 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305951
27 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290327
24 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281693
25 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969840
1 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965337
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 5 October 2010
Resolved
B1 fire extinguisher in engineroom vestibule was in a discharged condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported item has been corrected.
Engineering › Steering Gear System › Rudder
Issued 5 October 2010
Resolved
Stbd rudder arm has a 1/4" long hairline crack in weld.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported item has been corrected.
Engineering › Steering Gear System › Rudder
Issued 5 October 2010
Resolved
Stbd rudder arm was making contact with stop and a closer inspection revealed severe wastage. Stop requires replacement and adjustment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported item has been corrected.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 October 2010
Resolved
Vessel had correct number of lifebouys but two did not have the correct markings or lights attached.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported item has been corrected.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 October 2010
Resolved
Emergency light in [name withheld] stateroom did not work.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported item has been corrected.
Lifesaving › Lifefloat › Float Free
Issued 5 October 2010
Resolved
During inspection found loose gear stowed inside lifefloat. Had crew remove.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: Item corrected on the spot.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 October 2010
Resolved
Several lifejackets needed new retro material.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2010
Resolved 5 October 2010
Resolution: [name withheld] reported lifejackets were corrected.
Communications › Alarms/Indicators › General Alarm
Issued 17 February 2010
Resolved
General Alarm not operable on emergency power. Connect GA to emergency power and demonstrate proper operation.
Due 20 February 2010
Resolved 20 February 2010
Resolution: MI witnessed proper operation of GA.
Stability › Watertight Integrity › Coaming
Issued 17 February 2010
Resolved
Wastage found on coaming of ENG Room Hatch and hatch entering mess deck. Repair coaming to enable proper watertight/weathertight integrity.
Due 20 February 2010
Resolved 20 February 2010
Resolution: MI witnessed sat repairs to coaming on both hatches
Stability › Watertight Integrity › General
Issued 17 February 2010
Resolved
Hatch entering ENG room from main deck was inoperable. Repair door to show proper operation/closure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2010
Resolution: MI witnessed proper operation of ENG room hatch.
Engineering › Pressure Vessel › Marking and Stamping
Issued 17 February 2010
Resolved
Air reciever data plate unreadable. Provide readable data plate.
Due 20 February 2010
Resolved 20 February 2010
Resolution: MI witnessed readable data plate
Deck/Cargo › Holds/Tanks › Hatch
Issued 17 February 2010
Resolved
Engine room emergency escape hatch inoperable and needs repair. Repair and show proper operation of hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2010
Resolution: MI witnessed repair and proper operation.
Construction/Loadline › Hull › Longitudinal Frame
Issued 17 February 2010
Resolved
Frame under both Shafts show wastage. Repair frame.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2010
Resolution: MI witnessed repairs and conducted ND testing. All sat.
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 17 February 2010
Resolved
Excessive leak from STBD shaft. Insufficient number of nuts securing shaft packing. Tighten packing to ensure proper packing leakage is obtained and provide proper number of locking nuts.
Due 20 February 2010
Resolved 20 February 2010
Resolution: MI witnessed allowable leakage from shaft packing and proper number of locking nuts supplied.
Fire Fighting › Fire Pumps › Pressure
Issued 5 May 2009
Resolved
Demonstrate proper operation/pressure of vsl's fire pump.
Action required: 705 - Other - as specified
Resolved 12 May 2009
Resolution: Corrected on the spot.
Fire Fighting › Nozzles › Condition
Issued 5 May 2009
Resolved
Repair/replace one fire nozzle onboard vsl.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2009
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 5 May 2009
Resolved
Install a non-conductive mat at the generator switchboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2009
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 5 May 2009
Resolved
Repaint name and homeport on the stern of the vsl in contrasting colors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2009
Construction/Loadline › Hull › Side Shell
Issued 5 May 2009
Resolved
Properly secure one hanging tire on port side of vsl.
Action required: 705 - Other - as specified
Resolved 13 May 2009
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 4 June 2008
Resolved
Emergency instrucitons were not mounted at the operating station.
Action required: 705 - Other - as specified
Resolved 4 June 2008
Resolution: Corrected on the spot.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 4 June 2008
Resolved
Fuel transfer procedures were not mounted at the fuel transfer manifold.
Action required: 705 - Other - as specified
Resolved 4 June 2008
Resolution: Corrected on the spot.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 4 June 2008
Resolved
Flammable materials were being stowed in the machinery spaces vs. the paint locker.
Action required: 705 - Other - as specified
Resolved 4 June 2008
Resolution: Corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 June 2008
Resolved
The starboard navigantional light bulb was broken.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2008
Resolution: Corrected on the spot.
Fire Fighting › Fire Pumps › Pressure
Issued 4 June 2008
Resolved
The fire pump was not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2008
Resolution: Third party certificate of repair from Power Specialties, Inc.
Stability › Watertight Integrity › General
Issued 6 June 2007
Resolved
Watertight fitting leaking in aft end of Engine Room (rudder angle indicator piping).
Due 20 June 2007
Resolved 7 June 2007
Resolution: Repaired fitting that was leaking in aft end of Engine Room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 June 2007
Resolved
Exposed wiring found in engine room.
Due 20 June 2007
Resolved 7 June 2007
Resolution: Repaired exposed wiring.
Electrical › Electric Generation Source (service) › Generator
Issued 27 April 2007
Resolved
Stbd generator inop
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2007
Fire Fighting › Fire Pumps › Pressure
Issued 27 April 2007
Resolved
Fire pump unable to take prime.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2007
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 27 April 2007
Resolved
02 red flares missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2007
Communications › Public Address System › Announcing Station
Issued 27 April 2007
Resolved
Provide public address system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2007
Engineering › Steering Gear System › Motor
Issued 27 April 2007
Resolved
Steering pump #2 inop.
Due 11 June 2007
Resolved 6 June 2007
Resolution: Steering pump #2 operable.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 27 April 2007
Resolved
03 life jackets missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2007
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 16 April 2007
Resolved
unknown damage to shaft and shaft packing caused engineroom to flood.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 February 2007
Resolved
Monthy EPIRB checks were not conducted.
Action required: 705 - Other - as specified
Resolved 15 March 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 February 2007
Resolved
The life jacket donning placard was missing.
Due 15 March 2007
Resolved 15 March 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 12 February 2007
Resolved
The magnetic compass light was broken.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2007
Lifesaving › Lifefloat › Painter
Issued 12 February 2007
Resolved
The sea painter for the life float was not an approved type.
Due 15 March 2007
Resolved 15 March 2007
Fire Fighting › Fire Pumps › Gland Sealing
Issued 12 February 2007
Resolved
The fire pump had a leaking valve.
Due 15 March 2007
Resolved 15 March 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 February 2007
Resolved
The port and starboard generators needed guards for rotating machinery. The exhaust lagging on the port engine was worn and needed to be replaced.
Due 15 March 2007
Resolved 15 March 2007
Operations/Management › Pollution › Retention of Oily Mixture
Issued 21 July 2004
Resolved
Pump oily residue from engine room bilges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2004
Resolution: Pumped to dirty oil tank awaiting transfer to approved facility.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 July 2004
Resolved
Bilge alarm inoperative
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2004
Resolution: Electrician on board repaired during inspection.
Construction/Loadline › Structures › Deck Plating
Issued 21 July 2004
Resolved
replace missing bolts IWO main deck / engine room soft patches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2004
Resolution: Deck hand installing bolts during inspection.
Construction/Loadline › Hull › Bottom Plating
Issued 21 July 2004
Resolved
Crop and renew as original damaged shell plating:
bottom IWO fuel oil tank: 24"x36", forepeak portside 3'x6' , stbd side 3'x6'
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2004
Resolution: Plating repaired air tested sat.
Construction/Loadline › Hull › Bottom Plating
Issued 21 July 2004
Resolved
Crop and renew as original IWO port and stbd stuffing boxes, 24"x36" due to wastage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2004
Resolution: Repairs completed, dye pen test sat.
Construction/Loadline › Hull › Hull Plating
Issued 21 July 2004
Resolved
Crop and renew engine room aft bulkhead inboard of port stuffing tube due to wastage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2004
Resolution: Inserted as original, air test sat.
Navigation › Piloting/Steering
Issued 21 November 2003
Resolved
Provide compass deviation table. LEGACY COMPONENT DESC: Compass Deviation Table
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2003
Resolved 21 November 2003
Communications › Alarms/Indicators
Issued 21 November 2003
Resolved
Show proper operation of bilge alarm. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 21 November 2003
Electrical › Electrical Distribution System (service)
Issued 21 November 2003
Resolved
Show proper operation of generator switchboard lights. LEGACY COMPONENT DESC: Switchboard
Due 21 December 2003
Resolved 21 November 2003
Engineering › Bilge Water Management System › Manifold
Issued 21 November 2003
Resolved
Label bilge manifold
Due 21 December 2003
Resolved 21 November 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 21 November 2003
Resolved
Provide grease filter for range hood LEGACY COMPONENT DESC: Grease Filter
Due 21 December 2003
Resolved 21 November 2003
Stability › Weathertight Integrity
Issued 21 November 2003
Resolved
Show proper operation of all watertight doors. LEGACY COMPONENT DESC: Doors
Action required: 705 - Other - as specified
Due 21 December 2003
Resolved 21 November 2003
Communications › Radio Communications › Emergency Source of Power
Issued 18 November 2002
Resolved
Provide back up battery & charger for SSB and 1 VHF radio IAW 47 CFR part 80.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2002
Resolution: Suitable back up power provided.
Fire Fighting › Nozzles › Type
Issued 18 November 2002
Resolved
Provide on board CG approved nozzles
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2002
Resolution: Nozzles provided.
Lifesaving › Buoyant Apparatus
Issued 18 November 2002
Resolved
Remove gear adrift IWO lifefloats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2002
Resolution: Gear adrift removed prior to completion of inspection.
Operations/Management › Other Criminal/Civil Violations
Issued 18 November 2002
Resolved
Vessel operated 28 days with expired COI.
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 18 November 2002
Resolution: Vessel was presented to USCG for inspection.
Engineering
Issued 11 February 1991
Resolved
PROVIDE MAIN ENGINE STARTS IN PILOTHOUSE AS REQUIRED BY 46CFR 175.10-29
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991