MAURY USCG vessel records
← All vessels

DELRIVER

DELRIVER is a 1980 oil recovery. The Coast Guard has recorded 21 inspections since 2016, most recently in February 2025, along with 24 deficiencies and 2 casualty investigations between 2018 and 2019.

Records from 2016 to 2025. Most recent: inspection, 7 February 2025.

Built
1980
Last inspected
7 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

7923304
WAV8408
Flag
UNITED STATES
Maury page id
psix-51213

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (2016–2025)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it425 - Regulatory (Subpart C or D), Gross Ton
289 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 21

7 February 2025 Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8076326
5 February 2025 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8075200
25 April 2024 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7900848
12 March 2024 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7877877
30 November 2023 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7831653
7 April 2023 Deficiency Check · MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7665667
5 May 2022 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7447212
22 September 2021 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7318269
29 July 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7284567
27 April 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7184903
11 February 2020 Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6950554
23 January 2020 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6894898
10 May 2019 In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6681317
9 May 2019 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6681155
11 March 2019 Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6639982
8 May 2018 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6409306
5 January 2018 In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6333429
5 January 2018 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6334883
17 May 2017 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6148197
15 July 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5944464
2 May 2016 DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5859373

Deficiency record · 24

10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 25 April 2024 Resolved
The vessel's main steering gear and it's components must give full follow up control of the rudder. Vessel was unable to demonstrate satisfactory full follow up control of the rudder as rudder angle position had 5 degrees of variance with position of full follow up control lever in the pilot house. Ensure full follow up control steering is operating properly.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2024
Resolved 2 May 2024
Resolution: Vessels bridge full follow up control lever and indicator is operating satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2024 Resolved
Means shall be provided for closing all other openings to the space provided from outside such space. Bulkhead opening for shore tie system was unable to be closed from outside the space in the event of deployment of halon system. Ensure means are provided to close the opening.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2024
Resolved 2 May 2024
Resolution: Vessel installed cap on thru-bulkead shore tie connection port in ER.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2023 Resolved
Each cargo vessel must carry the number of lifebuoys as prescribed in table 46 CFR 199.271 of this section. The DELRIVER is required to have 08 lifebuoys and one lifebuoy was not in satisfactory condition. Replace lifebuoy with an approved typed lifebuoy in accordance with 46 CFR 160.150.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2023
Resolved 31 May 2023
Resolution: Vessel provided reeipt for new life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 May 2022 Resolved
(a) At each inspection for certification and periodic inspection the marine inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as he feels necessary to check safe operation. While witnessing main propulsion test MI found ahead and astern gauges indicator fault. Repair to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 19 May 2022
Resolution: Gauge reading correctly, SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 May 2022 Resolved
"it shall be the responsibility of the master to assure himself that all exposed cargo hatches and other openings in the hull of his vessel are closed, made properly watertight by the use of tarpaulins, gaskets or similar devices, and in all respects properly secured for sea before leaving protected waters." MI found bow deck watertight hatches securing lanyard not attached to watertight hatches. Attached securing lanyard to watertight hatches to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 19 May 2022
Resolution: Cover properly secured, SAT.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 May 2022 Resolved
(3) A mechanical means of closing each drain and scupper in the container or enclosed deck area required by this section. MI found no mechanical devises at the moment of the inspection. Provide mechanical devises to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 9 May 2022
Resolution: Mechanical plug provided.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 May 2022 Resolved
(1) Each fixture in the weather or in a location exposed to splashing water must be watertight. Each fixture in a damp or wet location must at least be dripproof. While inspecting the vessel MI found water inside two light fixtures. Repair to satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 19 May 2022
Resolution: Fixture fixed, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2021 Resolved
Engines have heater type hose that is hose clamped. Replace hoses with SAE J-1942 rated hose fitted with factory SAE J1475 fittings. 46 CFR §56.60-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 29 July 2021
Resolution: Verified replacement fuel line hoses
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 27 April 2021 Resolved
Both engine room exits leading to the weather deck are fitted with padlocks on the exterior. Propose alternate arrangement that would allow for a person egressing vessel to open door from inside if locked. 46 CFR 92.10-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 29 July 2021
Resolution: Verified installation of wing nut bolt pin that is removable from inside space for emergency exits
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 April 2021 Resolved
Engine exhaust lagging was found loose and not secure. Secure lagging. 46 CFR 56.50-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 29 July 2021
Resolution: Verified installation of lagging in E/R
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2021 Resolved
Steering failure alarm does not annunciate in wheelhouse. Troubleshoot, repair and provide findings. 46 CFR §58.25-25.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 29 July 2021
Resolution: Verified proper operation of Alarm
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021 Resolved
Multiple light fixtures in the machinery spaces had damaged lenses. Replace in kind. 46 CFR 111.01-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 29 July 2021
Resolution: Verified repair of damaged lights
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2021 Resolved
Extension cords are in permanent service throughout the machinery spaces. Evaluate installations, eliminate unnecessary cords and provide proposal for relocation or installation of additional receptacles as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 29 July 2021
Resolution: Verified remocval of extension cords
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2021 Resolved
At least two life ring buoys on the vessel must be fitted with a self activating smoke signal approved under 160.157. Life buoys fitted with smoke signals must also be fitted with lights. 46 CFR 199.70(3)(iii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2021
Resolved 29 July 2021
Resolution: Verified proper installation of Smoke signal on ring buoys.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 23 January 2020 Resolved
Vessel's Load Line Certificate is expired due to lack of required annual survey from issuing authority (ABS) for 2019. A new Load Line Certificate will be required prior to issuance of COI permitting the vessel to sail seaward of the boundary line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2020
Resolution: Vessel provided evidence of ABS attendance to complete annual Load Line survey and endorsement of Load Line Certificate.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 23 January 2020 Resolved
Vessel's liquid cargo hoses have not been tested to 150% of their MAWP in more than 5 years. MAWP is 150 psi; complete hydrostatic test of all hoses to 225 psi and document the results of this test in the ship's records. (Request you please let me know which date this will occur for training/observation purposes).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2020
Resolved 31 January 2020
Resolution: Vessel crew completed hydrostatic test at 1.5 times the MAWP (225 psi)
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 January 2020 Resolved
No original copy of FCC Station License onboard and photocopy of original is obscured in portion. Provide original copy of FCC Station License prior to issuance of COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2020
Resolved 4 February 2020
Resolution: Vessel provided original FCC station license.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2020 Resolved
15 of the 41 life jackets onboard are not equipped with marker lights. Equip these 15 life jackets with marker lights prior to issuance of COI that will permit up to 40 persons onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2020
Resolved 4 February 2020
Resolution: Vessel provided lights and equipped them to all 15 lifejackets that were previously missing them.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 May 2018 Resolved
Electrical panels and watertight doors were painted over, re-label as before.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 8 June 2018
Resolution: Verified labels for electrical panels were re-installed/re-painted. Verified that the WTD's were re-painted to indicate requirements to keep closed while underway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 May 2018 Resolved
Fans in the engine room were found without protective covers, install protective covers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 8 June 2018
Resolution: Verified installation of protective covers over vents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 May 2018 Resolved
Wiring was reversed for the forward and aft bilge alarms in the engine room, causing an alarm in the opposite location. Reverse the wiring as directed by the CGMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 8 June 2018
Resolution: Verified wiring for forward and aft bilge alarms were rewired correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 May 2018 Resolved
Glass on fire pump pressure gauge located on the thruster motor was broken; replace with calibrated gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 8 June 2018
Resolution: Verified installation of calibrated gauge on fire pump.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 5 January 2018 Resolved
1). All ocean vessels using electricity for ship's service power or light shall be provided with at least two ship's service generating sets. The capacity of the generating sets shall be sufficient to carry the necessary sea load under normal operation with any one generating set in reserve. The vessel's superintendent has reported that the ship's starboard service generator is inoperable due to damaged components in the armature end. Effect proper repairs to the damaged generator to the satisfaction of an attending CG Marine Inspector, including technician's diagnosis & recommended repair prescription(s). Alternatively, provide a proposal for replacing the generator to USCG MSD Lewes for approval. PRIOR TO SAILING. 46 CFR 111.10-1(b)(1) [OLD J].
Action required: 60 - Rectify deficiencies prior to movement
Due 13 January 2018
Resolved 13 January 2018
Resolution: Verified repair to generator.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 2 May 2016 Resolved
Fixed Halon System shall be weight tested and weight change shall not exceed 5% of weight. During weight test of vessel's only cylinder consisting of Halon, CG found that weight change exceeded 5%. Vessel shall overhaul fixed Halon system at next available drydock to the satisfaction of attending CG MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 12 August 2016

Casualty record · 2

5 January 2018Routine · role: Involved in a Marine Casualty · activity 6334883
9 May 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6681155
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record