A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Accommodation/Occupational Safety
Issued 6 June 1986
Resolved
MAKE NECESSARY REPAIRS TO ALL SYSTEMS AFFECTED BY THE FIRE IN THE TOOL PUSHER'S STATEROOM ON 5 JUNE 1986.
Condition: Unknown
Due 19 July 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 March 1985
Resolved
MAKE PERMANENT REPAIRS TO SPUD CAN #4 PRIOR TO RESUMING OEPRATIONS IN ACCORDANCE WITH 46 CFR 107.261
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Lifesaving
Issued 27 March 1985
Resolved
RESERVICE PORT SIDE LIFERAFT AND PROPERLY INSTALL PRIOR TO RESUMING OPERA- TIONS IN ACCORDANCE WITH 46 CFR 108.506
Condition: Unknown
Due 15 May 1985
Resolved 27 March 1985
Lifesaving
Issued 27 March 1985
Resolved
REPLACE NEOPRENE SEALS ON TWO (2) MUD PIT DUMP VALVES STBD SIDE WITHIN SEVEN (7) IN ACCORDANCE WITH 46 CFR 108.453.
Condition: Unknown
Due 15 May 1985
Resolved 27 March 1985
Lifesaving
Issued 27 March 1985
Resolved
REPAIR FOUR (4) WATER SPRAY NOZZLES ON #2 LIFEBOAT WITHIN SEVEN (7) DAYS IN ACCORDANCE WITH 46 CFR 108.503(G)(3)
Condition: Unknown
Due 15 May 1985
Resolved 27 March 1985
Lifesaving
Issued 19 July 1984
Resolved
INSTALL RING BUOY SMOKE SIGNALS ON THE OUTSIDE OF THE HANDRAILS.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984
Resolved
PROPERLY END LOOSE WIRE ON HYDRAULIC PUMP #3 MOTOR.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984
Resolved
REPAIR REVERSE POWER RELAY ON THE #3 GENERATOR.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Lifesaving
Issued 19 July 1984
Resolved
CONDUCT WEIGHT TESTS OF BOTH LIFEBOATS.
Condition: Unknown
Due 19 August 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 19 July 1984
Resolved
REPAIR OR REMOVE CONVEYOR.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Construction/Loadline
Issued 19 July 1984
Resolved
DETERMINE CAUSE OF WEEPING WELD 12' AFT OF THE FORWARD LEG RECESS AND 12' IN FROM THE STARBOARD SIDE AND REPAIR.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984
Resolved
INSULATE TOW GENERATOR EXHAUST MANIFOLD AND REPAIR GENERATOR SHACK SO IT ISWEATHERTIGHT.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984
Resolved
INSTALL PURGE ALARMS ON MARTIN DECKER METERS (2) AND GAS DETECTORS (2) ON THE RIG FLOOR.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Construction/Loadline
Issued 19 July 1984
Resolved
PROPERLY PACK SCR ROOM STUFFING TUBES AND SEAL AREA AROUND THE AIR CONDITIONER.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984
Resolved
REPAIR OR REMOVE THE DEAD END CABLE IN THE SCR ROOM AND COVER OPEN BREAKER SPACES ON THE MAIN SWTICHBOARD.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Accommodation/Occupational Safety
Issued 19 July 1984
Resolved
INSTALL FAN GUARD IN HYDRAULICS ROOM.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984
Resolved
LABEL ALL MCC AND START/STOP SWITCHES.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984
Resolved
PROVIDE PROPER BATTERY BOX FOR THE TOW GENERATOR STARTING BATTERY (LEAD- LINED, WOOD CHOCKED, COVERED).
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984
Resolved
STENCIL TOW GENERATOR EMERGENCY FUEL SHUTOFF VALVE.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Unknown
Issued 19 July 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE PHOENIX SEADRILL BIGFOOT ONE, DN618176.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Unknown
Issued 7 May 1982
Resolved
SATISFACTORILY TEST ALL THREE RIG SERVICE GENERATORS. ALSO TEST EMERGENCY GENERATOR.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE RELIEF VALVES OF THE PROPER TYPE ON ALL BULK TANKS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
REPLACE THE POTABLE WATER PRESSURE TANK RELIEF VALVE.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
LABEL THE FUEL OIL STORAGE TANK REMOTE SHUTDOWN VALVES.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
UPDATE ALL ELECTRICAL PANEL BOARD DIRECTORIES.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE PROPER HOSES AND BACK PRESSURE SHUTOFF VALVES FOR HALLIBURTON UNIT.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE AN ASME APPROVED RELIEF VALVE ON THE DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE POURED EYS FITTINGS AS NEEDED IN ALL HAZARDOUS AREAS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE A B-II FIRE EXTINGUISHER FOR THE HALLIBURTON UNIT AND THE SCHLUMBERGER UNIT.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
REPLACE THE MISSING GLOBES AND GUARDS ON TWO LIGHTS IN THE WELDING SHOP.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE A CRANE RECORD BOOK FOR EACH CRANE ON VESSEL AS PER 46 CFR 109.437.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
MAKE NECESSARY ENTRIES IN MASTER'S LOGBOOK AS PER 46 CFR 109.433.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE VESSEL WITH VALID FMC CERTIFICATE.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE VESSEL WITH APPROVED PAINT LOCKER. PLANS FOR PAINT LOCKER ARE TO BE SUBMITTED TO OCMI IN ZONE WHICH VESSELS IS LOCATED.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
SERVICE ALL PORTABLE AND SEMI-PORTABLE FIRE EXTINGUISHERS ON VESSELS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
SERVICE THE TWENTY-MAN INFALTABLE LIFERAFT AT A COAST GUARD APPROVED SER- VICING COMPANY. SERVICE THE HYDROSTATIC RELEASE ALSO.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE FIXED POLLUTION PREVENTION CONTAINMENT AROUND FUELING HOSE STATIONS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE NECESSARY EQUIPMENT FOR LINE THROWING APPARATUS AS PER 46 CFR 160.031.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
REPAIR OR REPLACE DEFECTION GENERAL ALARM WARNING BELLS LOCATED IN SCR ROOM AND OUTSIDE JACKING CONTROL HOUSE.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
INSTALL SEPARATE BATTERY INSTALLATIONS FOR THE FOGHORN, OBSTRUCTION LIGHTS AND GENERAL ALARM POWER SYSTEMS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
ENCLOSE AND PROVIDE A BATTERY CHARGER FOR THE EMERGENCY GENERATOR STARTING BATTERIES.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
REPLACE TORN FLAME SCREENS & FREE UP VENT COVERS ON FUEL OIL DAY TANKS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
FREE UP AND SATISFACTORILY TEST THE REMOTE SHUTOFF ON THE MAIN FUEL OIL DAYTANK.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
REPLACE THE SIGHT GLASSES ON BOTH FUEL OIL DAY TANKS WITH HEAT RESISTANT GLASS, AND PROTECT THEM WITH SUITABLE GUARDS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
LABEL ALL MOTOR CONTROLLERS WITH THE NAME OF THE MOTOR IT SERVES.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE VESSEL WITH A VALID LOADLINE CERTIFICATE.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982
Resolved
PROVIDE VESSEL WITH AN APPROVED U. S. COAST GUARD STABILITY LETTER AND OPERATING MANUAL.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982