MAURY USCG vessel records Sign in
← All vessels

PHOENIX SEADRILL BIG FOOT ONE

PHOENIX SEADRILL BIG FOOT ONE is a 1980 mobile offshore drilling unit. The Coast Guard has recorded 10 inspections since 1980, most recently in June 1989, along with 47 deficiencies.

Records from 1980 to 1989. Most recent: inspection, 16 June 1989.

Built
1980
Last inspected
16 June 1989
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-51214

Inspections, by type

…with no type recorded9
Years with a record 6 calendar years (1980–1989)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 37 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1962 - Regulatory (Subpart C or D), Net Ton
1962 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

16 June 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1341569
7 August 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 997758
6 June 1986 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 988568
27 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 980360
19 July 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 972732
10 August 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273095
21 June 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963748
7 May 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965115
7 May 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280977
31 March 1980 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969884

Deficiency record · 47

Accommodation/Occupational Safety
Issued 6 June 1986 Resolved
MAKE NECESSARY REPAIRS TO ALL SYSTEMS AFFECTED BY THE FIRE IN THE TOOL PUSHER'S STATEROOM ON 5 JUNE 1986.
Condition: Unknown
Due 19 July 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 27 March 1985 Resolved
MAKE PERMANENT REPAIRS TO SPUD CAN #4 PRIOR TO RESUMING OEPRATIONS IN ACCORDANCE WITH 46 CFR 107.261
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Lifesaving
Issued 27 March 1985 Resolved
RESERVICE PORT SIDE LIFERAFT AND PROPERLY INSTALL PRIOR TO RESUMING OPERA- TIONS IN ACCORDANCE WITH 46 CFR 108.506
Condition: Unknown
Due 15 May 1985
Resolved 27 March 1985
Lifesaving
Issued 27 March 1985 Resolved
REPLACE NEOPRENE SEALS ON TWO (2) MUD PIT DUMP VALVES STBD SIDE WITHIN SEVEN (7) IN ACCORDANCE WITH 46 CFR 108.453.
Condition: Unknown
Due 15 May 1985
Resolved 27 March 1985
Lifesaving
Issued 27 March 1985 Resolved
REPAIR FOUR (4) WATER SPRAY NOZZLES ON #2 LIFEBOAT WITHIN SEVEN (7) DAYS IN ACCORDANCE WITH 46 CFR 108.503(G)(3)
Condition: Unknown
Due 15 May 1985
Resolved 27 March 1985
Lifesaving
Issued 19 July 1984 Resolved
INSTALL RING BUOY SMOKE SIGNALS ON THE OUTSIDE OF THE HANDRAILS.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984 Resolved
PROPERLY END LOOSE WIRE ON HYDRAULIC PUMP #3 MOTOR.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984 Resolved
REPAIR REVERSE POWER RELAY ON THE #3 GENERATOR.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Lifesaving
Issued 19 July 1984 Resolved
CONDUCT WEIGHT TESTS OF BOTH LIFEBOATS.
Condition: Unknown
Due 19 August 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 19 July 1984 Resolved
REPAIR OR REMOVE CONVEYOR.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Construction/Loadline
Issued 19 July 1984 Resolved
DETERMINE CAUSE OF WEEPING WELD 12' AFT OF THE FORWARD LEG RECESS AND 12' IN FROM THE STARBOARD SIDE AND REPAIR.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984 Resolved
INSULATE TOW GENERATOR EXHAUST MANIFOLD AND REPAIR GENERATOR SHACK SO IT ISWEATHERTIGHT.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984 Resolved
INSTALL PURGE ALARMS ON MARTIN DECKER METERS (2) AND GAS DETECTORS (2) ON THE RIG FLOOR.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Construction/Loadline
Issued 19 July 1984 Resolved
PROPERLY PACK SCR ROOM STUFFING TUBES AND SEAL AREA AROUND THE AIR CONDITIONER.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984 Resolved
REPAIR OR REMOVE THE DEAD END CABLE IN THE SCR ROOM AND COVER OPEN BREAKER SPACES ON THE MAIN SWTICHBOARD.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Accommodation/Occupational Safety
Issued 19 July 1984 Resolved
INSTALL FAN GUARD IN HYDRAULICS ROOM.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984 Resolved
LABEL ALL MCC AND START/STOP SWITCHES.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984 Resolved
PROVIDE PROPER BATTERY BOX FOR THE TOW GENERATOR STARTING BATTERY (LEAD- LINED, WOOD CHOCKED, COVERED).
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Electrical
Issued 19 July 1984 Resolved
STENCIL TOW GENERATOR EMERGENCY FUEL SHUTOFF VALVE.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Unknown
Issued 19 July 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE PHOENIX SEADRILL BIGFOOT ONE, DN618176.
Condition: Unknown
Due 19 July 1984
Resolved 19 July 1984
Unknown
Issued 7 May 1982 Resolved
SATISFACTORILY TEST ALL THREE RIG SERVICE GENERATORS. ALSO TEST EMERGENCY GENERATOR.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE RELIEF VALVES OF THE PROPER TYPE ON ALL BULK TANKS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
REPLACE THE POTABLE WATER PRESSURE TANK RELIEF VALVE.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
LABEL THE FUEL OIL STORAGE TANK REMOTE SHUTDOWN VALVES.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
UPDATE ALL ELECTRICAL PANEL BOARD DIRECTORIES.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE PROPER HOSES AND BACK PRESSURE SHUTOFF VALVES FOR HALLIBURTON UNIT.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE AN ASME APPROVED RELIEF VALVE ON THE DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE POURED EYS FITTINGS AS NEEDED IN ALL HAZARDOUS AREAS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE A B-II FIRE EXTINGUISHER FOR THE HALLIBURTON UNIT AND THE SCHLUMBERGER UNIT.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
REPLACE THE MISSING GLOBES AND GUARDS ON TWO LIGHTS IN THE WELDING SHOP.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE A CRANE RECORD BOOK FOR EACH CRANE ON VESSEL AS PER 46 CFR 109.437.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
MAKE NECESSARY ENTRIES IN MASTER'S LOGBOOK AS PER 46 CFR 109.433.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE VESSEL WITH VALID FMC CERTIFICATE.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE VESSEL WITH APPROVED PAINT LOCKER. PLANS FOR PAINT LOCKER ARE TO BE SUBMITTED TO OCMI IN ZONE WHICH VESSELS IS LOCATED.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
SERVICE ALL PORTABLE AND SEMI-PORTABLE FIRE EXTINGUISHERS ON VESSELS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
SERVICE THE TWENTY-MAN INFALTABLE LIFERAFT AT A COAST GUARD APPROVED SER- VICING COMPANY. SERVICE THE HYDROSTATIC RELEASE ALSO.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE FIXED POLLUTION PREVENTION CONTAINMENT AROUND FUELING HOSE STATIONS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE NECESSARY EQUIPMENT FOR LINE THROWING APPARATUS AS PER 46 CFR 160.031.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
REPAIR OR REPLACE DEFECTION GENERAL ALARM WARNING BELLS LOCATED IN SCR ROOM AND OUTSIDE JACKING CONTROL HOUSE.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
INSTALL SEPARATE BATTERY INSTALLATIONS FOR THE FOGHORN, OBSTRUCTION LIGHTS AND GENERAL ALARM POWER SYSTEMS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
ENCLOSE AND PROVIDE A BATTERY CHARGER FOR THE EMERGENCY GENERATOR STARTING BATTERIES.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
REPLACE TORN FLAME SCREENS & FREE UP VENT COVERS ON FUEL OIL DAY TANKS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
FREE UP AND SATISFACTORILY TEST THE REMOTE SHUTOFF ON THE MAIN FUEL OIL DAYTANK.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
REPLACE THE SIGHT GLASSES ON BOTH FUEL OIL DAY TANKS WITH HEAT RESISTANT GLASS, AND PROTECT THEM WITH SUITABLE GUARDS.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
LABEL ALL MOTOR CONTROLLERS WITH THE NAME OF THE MOTOR IT SERVES.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE VESSEL WITH A VALID LOADLINE CERTIFICATE.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982
Unknown
Issued 7 May 1982 Resolved
PROVIDE VESSEL WITH AN APPROVED U. S. COAST GUARD STABILITY LETTER AND OPERATING MANUAL.
Condition: Unknown
Due 7 May 1982
Resolved 7 May 1982

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.