OCEAN LIBERTY

OCEAN LIBERTY is a 1980 oil recovery. The Coast Guard has recorded 17 inspections since 2016, most recently in October 2023, along with 32 deficiencies and 1 casualty investigation in 2008.

Records from 2008 to 2023. Most recent: inspection, 11 October 2023.

Built
1980
Last inspected
11 October 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 October 2023
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7923299
WDJ8856
Flag
UNITED STATES
Maury page id
psix-51215

Documentation record

Tonnage as PSIX records it290 - Regulatory (Subpart C or D), Gross Ton
197 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

11 October 2023 Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7807148
28 June 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7724361
7 October 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7573579
22 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7270018
1 July 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7241990
1 June 2021 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7247316
13 August 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7032986
31 July 2020 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7047181
23 July 2019 Internal Structural Exam · Deficiency Check · Annual Inspection · Administrative Inspection · Inclining Experiment · Underwater Inspection in lieu of Drydock · DAPI Audit
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6753766
17 September 2018 Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6542723
6 August 2018 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6503462
14 June 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6154662
8 August 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5966404
10 June 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6028843
20 May 2016 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5874888
13 April 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5854162
26 January 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5777859

Deficiency record · 32

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 June 2023 Resolved
At each inspection for certification the inspector will check the fire-extinguishing equipment with the following tests: on all fire extinguishing systems, all piping controls, valves, and alarms must be checked to ascertain that the system is in operating condition. Vessel's system is within date but could not be demonstrated during inspection. Fire company scheduled to demonstrate system on 19JUL23. 46 CFR 91.25-20(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 19 July 2023
Resolution: Witnessed fixed fire system testing. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2023 Resolved
All vessels except unmanned barges shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment. Pin hold and epoxy patch found on vessels bilge / fire pump approximately 4ft above pump. Pump is leaking. 46 CFR 56.50-50
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 7 September 2023
Resolution: Vessel replaced pipe where epoxy patch was and rebuilt the pump. Operational tests all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2023 Resolved
Shutoff valves shall be installed in the fuel supply lines. Valves shall be accessible at all times. Vessels shut off valve is stripped. 46 CFR 50-75(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 7 September 2023
Resolution: Vessel added nut to the valves so it can be closed properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2023 Resolved
Lead or other heat sensitive materials shall not be used in piping systems which make such bulkhead or deck penetrations where the deterioration of such systems in the event of fire would impair the integrity of the bulkheads. Branch of vessels bilge piping through and forward of the engine room is plastic piping. 46 CFR 56.50-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 8 August 2023
Resolution: Vessel replaced pipe with steel pipe.
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 28 June 2023 Resolved
Fuel oil and lubricating oil discharge containments shall have the ability to close each drain or scupper within the coaming. The Port Dirty Oil containment mechanical plug is missing.33 CFR 155.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 8 August 2023
Resolution: Vessel has appropriate plugs.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 28 June 2023 Resolved
Containers, brackets, racks, and other similar stowage locations for lifesaving equipment must be marked with symbols IAW IMO Res. A.760(18). Vessel does not have lifejacket and immersion suit stowage location markings. 46 CFR 199.178 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 8 August 2023
Resolution: Vessel removed lifesaving from box behind bridge.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 20 October 2022 Resolved
Tests and inspections to evaluate the operation and reliability of controls, alarms, and safety features for monitored machinery systems must be verified periodically. The E/R Main Machinery Alarm Panel power failure test did not function as designed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 15 November 2022
Resolution: Vessel replaced batteries, system operates as designed.
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 20 October 2022 Resolved
Fuel oil and lubricating oil discharge containments shall have the ability to close each drain or scupper within the coaming. The Port Dirty Oil containment mechanical plug is missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 16 November 2022
Resolution: Vessel has mechanical plug for port dirty oil containment.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 October 2022 Resolved
Each vessel must carry a category 1 406 MHz satellite EPIRB meeting the requirements of 47 CFR part 80. Vessel's EPIRB had expired batteries. Make permanent repairs prior to departing further than 3 NM from land. 46 CFR 199.510(a)
Action required: 705 - Other - as specified
Resolved 24 October 2022
Resolution: Vessel provided objective evidence that new epirb has been installed and registered.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 October 2022 Resolved
Each vessel must carry not less than 12 rocket parachute flares approved under approval series 160.136. Vessel has mixture of 6 hand flares, 3 rocket parachute flares, and 3 smoke flares. 46 CFR 199.60(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2022
Resolved 15 November 2022
Resolution: Vessel obtained 12 rocket parachute flares.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 August 2020 Resolved
It shall be the duty of the owner, master, or person in charge to require the fixed fire extinguishing systems on board once in every twelve months. Vessel fixed fire suppression systems need to be serviced no later than 14SEP2020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2020
Resolved 31 August 2020
Resolution: Vessel rep submitted Taylorfire annual servicing cert under MISLE activitiy 7047181.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 August 2020 Resolved
Vessel must comply with the stability letter and LLC issued to the vessel. Vessel had none watertight gasket on the aft watertight door leading into the galley and the watertight door from the galley to teh engine room.
Action required: 10 - Deficiency Rectified
Resolved 14 August 2020
Resolution: Vessel rep installed watertight gasket.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 14 November 2019 Resolved
Deck cargo was found to be roughly 15 ft high and not stored in compliance with posted stability letter. Remove deck cargo that exceeds max of 6 feet in height per posted stability letter or have stability recalculated and approved by Marine Safety Center to meet cargo storage requirements. 46 CFR 170.120
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 November 2019
Resolved 8 July 2021
Resolution: Vessel did not have stacked cargo on deck.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 July 2019 Resolved
The main steering gear, must be capable of moving the rudder from 35 degrees on either side to 35 on the other. Steering gear pump number 2 does not operate from local control to starboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2019
Resolved 30 July 2019
Resolution: Vessel demonstrated a satisfactory steering test.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 July 2019 Resolved
All vessels other than motor boats shall carry spare charges for at least 50 percent. Vessel has 10 portable extinguishers of which 9 are required as per the COI. The vessel is missing the following required spares: 1-120B, 1-2A, 1-20BC, and 3-40BC.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2019
Resolved 30 July 2019
Resolution: Vessel was equipped with adequate amount of spares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2019 Resolved
Periodic Safety tests must demonstrate the proper operation of the primary and alternate control alarms, power sources, transfer override arrangements, interlocks, and safety controls. Vessel crew was unable to demonstrate Periodic Safety Test Procedures (PSTP).
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2019
Resolved 30 July 2019
Resolution: Vessel conduced periodic safety test procedures with FUSION in attendance.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 July 2019 Resolved
Marine employer does not have marine drug testing program, random drug testing program, Employee Assistance Program, Management Information System form, and consortium or third party program administrator. Vessel is not in compliance with required Drug and Alcohol Program, due to an expired compliance letter.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2019
Resolved 30 July 2019
Resolution: Vessel provided compliance letter, all sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 July 2019 Resolved
At each inspection for certification and periodic inspection, the inspector shall test fire extinguishing equipment IAW table 91.25-30(a)(1). Fixed fire fighting servicing was not made available or tested since 05JUN2018.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2019
Resolved 30 July 2019
Resolution: Vessel provided servicing tech to demonstrate servicing maintenance in the presence for [name withheld] servicing was completed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 July 2019 Resolved
AIS must be maintained in effective operating condition, which includes the accurate input and upkeep of all AIS data fields and system updates.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 July 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 26 July 2019 Resolved
Inspector not limited from making such tests or inspections deemed necessary. Vessel crew is unable to demonstrate operation of installed OWS (OWS not required per CFR)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2019
Resolved 30 August 2019
Resolution: 7/30/19: Crew locked out system and does not intend on using for the time being. 8/30/2019: Vsl installed Calibrated (MEPC.107 (49)) oil content monitor and proved proper operation of system.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 July 2019 Resolved
Materials used in the manufacture of tubing, pipes, valves, flanges, and fittings shall be selected from those specifications that appear in the CFR or ASME Section VIII. Crossover between the steering hydraulic tanks is not an approved material (hard piped or SAEJ1942).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2019
Resolved 30 July 2019
Resolution: Vessel removed the hydraulic hose and intends on replacing with a SAWJ1942 approved hose.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 July 2019 Resolved
Scope of inspection shall include inspection of structure, boilers, and other pressure vessels, machinery, and equipment. Flame screens have holes, are rusted, and/or missing bolts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2019
Resolved 30 July 2019
Resolution: Vessel crew rectified the worn flame screens. All sat.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 26 July 2019 Resolved
Scope of inspection shall include inspection of structure, boilers, and other pressure vessels, machinery, and equipment. 03 P/V valves located on the port (01) and starboard (02) are corroded.
Action required: 10 - Deficiency Rectified
Resolved 26 July 2019
Resolution: P/V valves were cleaned and reinstalled.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 26 July 2019 Resolved
Drills must, as far as practicable, be conducted as if there were an actual emergency. Vessel failed fire drill by not responding to the fire as prescribed by the vessel procedures.
Action required: 10 - Deficiency Rectified
Resolved 26 July 2019
Resolution: The second fire drill conducted was satisfactory.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 6 August 2018 Resolved
Current arrangement requires rescue swimmer to enter water to recover unconscious man overboard. Provide means to rescue person in water without need to have swimmer enter water.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 6 September 2018
Resolved 17 September 2018
Resolution: Vessel obtained a lifesling and [name withheld] to aid in man overboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2018 Resolved
Unable to test MDE's and SSDG's per PSTP's due to lack of testing equipment. Provide testing equipment and conduct all required test for MDE's and SSDG's per approved PSTP's.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 September 2018
Resolved 17 September 2018
Resolution: Attended vessel with Fusion and successfully tested PSTP's
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 August 2018 Resolved
Deck cargo was found to be roughly 15 ft high and not stored in compliance with posted stability letter. Remove deck cargo that exceeds max of 6 feet in height per posted stability letter or have stability recalculated and approved by Marine Safety Center to meet cargo storage requirements. 46 CFR 170.120
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 6 September 2018
Resolved 26 July 2019
Resolution: Conducted stability incline test.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 August 2018 Resolved
Electrical wires were found unsupported or inadequately supported in engine room. Properly support all electrical wires in accordance with IEEE 45-2002 25.5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2018
Resolved 17 September 2018
Resolution: All unsupported wires were supported with SS straps. Def Cleared.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 August 2018 Resolved
4 portable fire extinguishers were found with J hook brackets. Provide the correct brackets which will hold the extinguisher securely in its stowage location.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2018
Resolved 17 September 2018
Resolution: All J-hook brackets were replaced with an approved bracket. Def Cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 August 2018 Resolved
Required 12 rocket parachute flares and only had three onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 August 2018
Resolved 6 August 2018
Resolution: 9 distress signals were purchased prior to completion of inspection. Def Cleared.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 August 2018 Resolved
Marine cable transits in fwd engine-room watertight bulkhead were found loose and not water tight. Tighten or replace packing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 August 2018
Resolved 6 August 2018
Resolution: stuffing tubes were replaced and tightened. Def cleared.
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 13 April 2016 Resolved
Make permanent repairs to the engine room fire suppression system. Operate in accordance with the detail plan dated 13 April 2016.
Due 13 April 2016
Resolved 21 April 2016
Resolution: Received fire servicing report from Ross Marine Fire Safety.

Casualty record · 1

31 July 2008Routine · role: Involved in a Marine Casualty · activity 3285253
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CLEAN BAY II (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.