MAURY USCG vessel records Sign in
← All vessels

MARY CHERAMIE

MARY CHERAMIE is a 2002 industrial vessel. The Coast Guard has recorded 33 inspections since 2002, most recently in July 2025, along with 43 deficiencies.

Records from 2002 to 2025. Most recent: inspection, 10 July 2025.

Built
2002
Last inspected
10 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9271171 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDK8678
512198
Flag
UNITED STATES
366854410
Maury page id
psix-512198

Inspections, by type

…with no type recorded5
Years with a record 19 calendar years (2002–2025)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)152.4 ft × 46.0 ft × 13.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)152.4 ft × 46.0 ft × 13.0 ft
ITC tonnagegross 703 / net 210
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 May 2026 · expires 30 June 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
703 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
210 - Convention (Subpart B), Net Ton
850 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK8678MMSI 366854410 · active · compulsorily equipped · granted 30 May 2019, expires 30 May 2029
WDH3445MMSI 366854410 · cancelled · compulsorily equipped · granted 26 February 2014, cancelled 22 May 2019 · licensed under a name not among this hull’s recorded names (not shown)
WDA8444MMSI 366854410 · cancelled · compulsorily equipped · granted 15 March 2012, cancelled 27 January 2014 · licensed under a name not among this hull’s recorded names (not shown)
WDB2257MMSI 367124970 · expired · compulsorily equipped · granted 9 November 2002, cancelled 12 January 2013 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 33

10 July 2025 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8153821
3 May 2024 Administrative Inspection · Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7905934
26 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7856028
20 July 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7714989
15 June 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7716029
29 April 2022 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7440552
6 April 2022 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7425354
10 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7002535
20 May 2019 Drydock Exam · Internal Structural Exam · Periodic Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6690384
8 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6658520
5 October 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6587308
10 September 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6553068
3 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6280125
17 May 2017 COI Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6148123
22 July 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5949556
17 June 2016 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5922231
31 July 2015 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5206940
13 June 2014 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4886823
5 June 2014 Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4880532
21 May 2014 Hull Examination · Cargo Tank Internal · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4863480
24 May 2012 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4319587
11 May 2012 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4308474
7 July 2011 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4073106
29 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3311945
18 July 2008 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3271760
7 May 2007 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2920522
30 April 2007 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2919077
21 July 2005 Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2434755
9 June 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2384744
23 May 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2367148
2 June 2004 Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2086325
5 August 2003 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1867085
10 May 2002 Internal Structural Exam · Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1613391

Deficiency record · 43

01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 20 July 2023 Resolved
There must be a sufficient number of persons to operate the launching arrangements of survival craft; vessel did not have sufficient lifeboatmen/lifeboatmen-limited. 46 CFR 199.100(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2023
Resolved 24 July 2023
Resolution: Crew changed to include appropriate endorsements.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 July 2023 Resolved
Scope of annual inspection is the same as that for COI; during inspection, noted three (03) WTDs and one (01) escape hatch to not seal properly. 46 CFR 126.510(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2023
Resolution: All issues rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 July 2023 Resolved
Liferafts must be arranged for float-free launching; liferaft improperly hooked up. 46 CFR 133.130(b)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 20 July 2023
Resolution: Re-installed
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 20 July 2023 Resolved
Each vessel must comply with 47 CFR part 80; vessel did not have SSB or MF. 46 CFR 130.210
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2023
Resolved 6 September 2023
Resolution: Installation complete.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2023 Resolved
Vessel must be designed and constructed to minimize fire hazards; vessel had leaking fuel filter and high-pressure fuel line on stbd MDE. 46 CFR 127.220(c)
Action required: 10 - Deficiency Rectified
Resolved 20 July 2023
Resolution: Fuel leakages addressed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 April 2022 Resolved
Electric installations and equipment must be inspected to determine mechanical and electrical condition and performance. Starboard generator would not start. 46 CFR 110.30-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2022
Resolution: Witnessed operable starboard generator.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 29 April 2022 Resolved
The steering gear must be capable of moving the rudder from 35 degrees on either side to 35 degrees on the other. Starboard side rudder would not go past 30 degrees. 46 CFR 58.25-10(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 4 May 2022
Resolution: Witnessed rudder angle indicator match steering.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2022 Resolved
Inspection of machinery shall ensure satisfactory condition and fit for the service for which it is intended. Port main engine had a jacket water leak. 46 CFR 91.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 4 May 2022
Resolution: Jacket water leak was corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 April 2022 Resolved
The emergency power source must meet table 112.05-5(a) and have the capacity to supply all loads that are simultaneously connected to it. The emergency lighting in the engine room was inoperable. 46 CFR 112.05-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2022
Resolved 4 May 2022
Resolution: Witnessed operable emergency lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 May 2019 Resolved
Permanently affix number of persons and number of life raft to each liferafts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2019
Resolved 28 June 2019
Resolution: Verified Markings
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 May 2019 Resolved
Mark vessel hull with hailing port and name in clear legible letters of the Latin alphabet or Arabic or Roman numerals not less than 4 inches in height.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2019
Resolved 28 June 2019
Resolution: Markings verified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 May 2019 Resolved
Provide documentation of vessel enrollment into Vessel General Permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2019
Resolved 27 June 2019
Resolution: Verfied enrollment
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 20 May 2019 Resolved
Vessel required to have approved NTVRP. Plan has to be submitted, provide approval letter within 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2019
Resolved 19 August 2019
Resolution: Approval letter recieved.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 May 2019 Resolved
Provide appropriate size charts for navigable waterways in operating area.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 June 2019
Resolution: Reviewed new charts.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 May 2019 Resolved
Update vessel name on the fire and life saving plans.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2019
Resolved 19 August 2019
Resolution: Vessel name was placed on fire and safety plan
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2019 Resolved
Provide three additional life jackets to satisfy life saving requirements for vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2019
Resolved 27 June 2019
Resolution: Provided additional life jackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2019 Resolved
Replace wasted fuel hoses on the port MDE fuel return line, starboard MDE fuel return line, and starboard generator fuel line.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2019
Resolution: Fuel hoses replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 May 2019 Resolved
Adjust watertight doors to ensure watertight integrity is met.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2019
Resolution: Adjusted door
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 May 2019 Resolved
Adjust engine room emergency escape hatch to ensure that it can be opened and closed properly from the interior of the ship.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2019
Resolution: Adjusted hatch
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 May 2019 Resolved
Provide proper operation of vessel navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2019
Resolution: Proved proper operation of navigation lights
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 May 2019 Resolved
Replace inoperable rudder angle indicator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2019
Resolution: Proved proper operation of the rudder angle indicator.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 May 2019 Resolved
Security drills, exercises not conducted, and VSO not familiar with VSP. Conduct security drills, exercises, and ensure VSO familiarity with VSP.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 June 2019
Resolution: Conducted exercises and security drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 May 2019 Resolved
Repair leaking reduction gear expansion tank sight glass.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2019
Resolved 27 June 2019
Resolution: Leak repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 May 2019 Resolved
Replace missing exhaust lagging in the engine room and in the passage way leading to the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2019
Resolution: Lagging replaced
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 September 2018 Resolved
Two (02) engine room e-lights inoperable
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2018
Resolution: Batteries replaced and e-lights working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2018 Resolved
Racor drain plugs missing
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2018
Resolution: Plugs placed under Racor filters
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 September 2018 Resolved
Engine room emergency escape hatch needs new gasket and adjustment
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2018
Resolution: New gasket installed and chalk tested for seal, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 September 2018 Resolved
Float light batteries expired
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2018
Resolution: Float light batteries replaced
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 10 September 2018 Resolved
Oily water in engine room bilge
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2018
Resolution: Oily water removed from bilge and bilge cleaned
Fire Fighting › Firemans Outfit › Axe
Issued 8 June 2017 Resolved
MISSING 01 FIRE AX. ADD 01 FIRE AX. 46CFR95.60-5(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 13 June 2017
Resolution: 01 FIRE AX WAS ADDED TO VESSEL.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 June 2017 Resolved
NEED APPROVED PLANS DISPLAYED FOR FIRE AND SAFETY. 46CFR97.36-1(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 July 2017
Resolved 13 June 2017
Resolution: FIRE & SAFETY PLAN STAMPED ON 12 JUN 2017 AND APPROVED. PLANS DISPLAYED IN GALLEY OF VESSEL.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 July 2015 Resolved
Background of nav lights painted semi-gloss blue on both port and starboard lights.
Action required: 705 - Other - as specified
Due 7 August 2015
Resolved 1 August 2015
Resolution: Crew painted backgrounds with flat black paint.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 31 July 2015 Resolved
Vessel had on board NOI issued prior to vessel ownership and name change.
Action required: 705 - Other - as specified
Due 31 August 2015
Resolved 7 August 2015
Resolution: Received updated VGP NOI from vessel rep.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 June 2014 Resolved
Emergency lighting not provided at the life rafts.
Due 13 July 2014
Resolved 17 June 2014
Resolution: E- lighting installed at the life rafts.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 13 June 2014 Resolved
STBD SSDG cannot maintain the electrical load when fire or bilge pumps are energized.
Action required: 705 - Other - as specified
Resolved 17 June 2014
Resolution: Generator was tested while vessel was underway conducting a DP test. All sat.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 24 May 2012 Resolved
Port/STBD MDE being serviced at time of inspection. Vessel shall contact once both MDE are ready for complete testing by marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2012
Resolution: Port/Stbd MDE properly demonstrated for E-stops and normal operation, guages, clutches and alarms.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 24 May 2012 Resolved
EPA VGP NOI missing onboard vessel. Vessel shall provide copy of NOI onboard vessel.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 31 May 2012
Resolution: EPA VGP NOI onboard vessel.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 24 May 2012 Resolved
Port/STBD air receivers have incorrect pop-off size relief valves. Vessel shall replace both Port/STBD air recievers pop-off relief valves with correct size.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 31 May 2012
Resolution: Verified air receivers pop-off relief valves correct size.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 18 July 2008 Resolved
Anchor chain shows signs of significant wasteage. Vsl tp provide evidence of acceptable standards to ABS rules or replace in kind.
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 24 June 2009
Resolution: Anchor chain meets standards
Engineering › Fuel Oil Service System › Piping
Issued 2 June 2004 Resolved
Renew main engine fuel hoses with SAE J-1942 or with SAE 1527. Coast Guard Inspectors will contact Marine Safety Center to determine authorization of Caterpillar hose, SAE 100R2 Type AT.
Action required: 705 - Other - as specified
Due 2 July 2004
Resolved 5 June 2004
Resolution: Vessel SAE 1527 fuel hoses came as package with engine. Fuel hoses were determined satisfactory.
Electrical › Electric Generation Source (service) › Generator
Issued 2 June 2004 Resolved
Make repairs to number one and number two generator overspeeds and provide third party documentation to the satisfaction of Coast Guard attending Marine Inspector.
Action required: 705 - Other - as specified
Due 2 July 2004
Resolved 5 July 2004
Resolution: Vessel made repairs to the number one and number two generator overspeeds as well as provided thrid party repair documentation.
Personnel › Certificates/Documents/Licenses
Issued 10 May 2002 Resolved
Provide licensed master and crew prior to operating vessel. LEGACY COMPONENT DESC: License, Master
Action required: 705 - Other - as specified
Due 13 May 2002
Resolved 10 May 2002
Resolution: Licensed master and crew were provided on 10 May 02.
Operations/Management › Drills/Instruction
Issued 10 May 2002 Resolved
Prior to operating vessel, conduct fire, abandon ship and man overboard drills. LEGACY COMPONENT DESC: Fire
Action required: 705 - Other - as specified
Due 13 May 2002
Resolved 10 May 2002
Resolution: All drills were conducted to the satisfaction of the attending marine inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.