Documentation record
Registered dimensions (L × B × D)45.3 ft × 14.8 ft × 7.8 ft
Registered tonnagegross 32 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMEDLEY, FL, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCAPE CHARLES, VA
Endorsements, as the file codes themcw_un, fi, rec
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 15 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 15
24 April 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7674743
17 March 2023
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7646423
2 May 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7442431
25 April 2022
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7434605
23 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7178051
26 March 2021
Hull Examination · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7162934
20 April 2020
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6941282
26 April 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6671182
22 March 2019
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6642545
2 May 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6393337
27 April 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6129855
31 March 2017
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6113153
7 June 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5908452
12 May 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5874346
2 May 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5862111
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts; charts not updated per broadcase notice to mariners; rectify within 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2022
Resolved 2 May 2022
Resolution: Owner/operator demonstrated charts had been updated with appropriate BNMs
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 April 2022
Resolved
Life floats must be equipped with a floating water light approved under series 161.010 or other standard approved by the Commandant; water light battery expired; repair/replace within 7 days.
Action required: 705 - Other - as specified
Due 2 May 2022
Resolved 2 May 2022
Resolution: owner/operator replaced the waterlight with one of an approved type.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 April 2021
Resolved
The waterlight for the lifefloat must be attached around the body of the lifefloat. The lifefloat light was not wrapped around the body and was attached to a becket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 26 May 2021
Resolution: Master provided documentation of correct arrangement of waterlight line.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 April 2021
Resolved
Hatches exposed to weather must be water tight. FWD and AFT hatches did not have gaskets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 30 April 2021
Resolution: MI's attended vessel and completed sat chalk test of gaskets on water tight hatches.
Lifesaving › Lifebuoys › Serviceable
Issued 27 April 2017
Resolved
The vessle's ring life buoy grab line is detriorated. Renew to original condition to the satisfaction of the Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 26 May 2017
Resolution: Vessel owner renewed the ring life buoy's grab line as original.
Engineering › Steering Gear System › Rudder
Issued 2 May 2016
Resolved
Port rudder post on steering gear was leaking. Old "T" 46CFR182.30-1.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 12 May 2016
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 2 May 2016
Resolved
Fixed halocarbon fire fighting system bottle was past hydrostatic test date. 46CFR176.810(b)(2).
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 10 June 2016
Resolution: Owner/operator emailed photograph of fire system servicing report for servicing on 25 April 2016.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 May 2016
Resolved
Starboard waterlight battery on lifefloat was expired.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 12 May 2016
Communications › Radio Communications › EPIRB
Issued 2 May 2016
Resolved
EPIRB did not have registration. 47CFR80.106(f).
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 12 May 2016
Lifesaving › Hand Flares › Storage
Issued 2 May 2016
Resolved
Flare container was missing watertight latch.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 12 May 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2016
Resolved
First aid kit was missing ammonia inhalants.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 12 May 2016