MAURY USCG vessel records Sign in
← All vessels

DANIEL MATHENY V

DANIEL MATHENY V is a 2002 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2002, most recently in June 2026, along with 34 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2009 and 2014.

Records from 2002 to 2026. Most recent: inspection, 24 June 2026.

Built
2002
Last inspected
24 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

512332
Flag
UNITED STATES
—
Maury page id
psix-512332

Inspections, by type

…with no type recorded1
Years with a record 20 calendar years (2002–2026)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.0 ft × 32.7 ft × 4.0 ft
Registered tonnagegross 69 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARCOM INC · PORTLAND, OR, UNITED STATES · built 2002
Hull materialSteel
PropulsionElectric Motor
Hull shapeBox
Hull configurationMonohull
Hailing portWHEATLAND, OR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Simplified, Gross Ton
55 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

24 June 2026 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8412913
24 September 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8010735
6 October 2023 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7807499
17 August 2022 COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7512133
6 July 2022 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7499100
27 January 2022 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7398170
26 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7207266
31 July 2020 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7024043
13 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6718395
20 February 2019 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6629125
19 March 2018 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6376736
31 May 2017 COI Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6162000
11 May 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5873888
12 July 2012 Hull Examination · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4313956
17 January 2012 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4225840
12 March 2010 Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3693320
16 March 2009 Annual Inspection · Plan Review "T" Boat
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3360508
2 February 2009 Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3413599
1 February 2009 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3413616
17 March 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3162182
29 June 2007 In-Service Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2977561
5 April 2007 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2882822
5 February 2007 Deficiency Check · In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2819915
28 March 2006 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2592617
23 August 2005 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2472560
28 June 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2406557
3 March 2005 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2293796
5 May 2004 Plan Review "T" Boat · In-Service Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2060204
22 March 2004 Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2017349
1 July 2003 Plan Review "T" Boat
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1838487
23 June 2003 Deficiency Check · Plan Review "T" Boat
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1824491
21 May 2003 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1789462
28 March 2002 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1602473

Deficiency record · 34

09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 June 2026 No resolution recorded
[name withheld] Public Works shall install protective guards around the exposed portions of the DANIEL MATHENY V's propulsion shafting on both sides of the cable ferry. The protective guards shall be installed prior to the completion of the vessel's next scheduled dry-docking in July of 2027.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 July 2027
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2021 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The lanyard attaching the waterlight to the ring life buoy was found to be frayed and worn. Replace with a suitable lanyard to the satisfaction of the attending marine inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 27 January 2022
Resolution: Life buoy lines replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 May 2021 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each unmanned space. Installed float switches in multiple voids were found to be inoperable / unable to be tested for audible and visual alarm. Repair or Replace the bilge high water level monitors and demonstrate proper operation to the attending marine inspector.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 27 January 2022
Resolution: verified operation of audible and visual high bilge alarms in wheel house.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 May 2021 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: (1) A hatch on a watertight trunk that extends at least 305 millimeters (12 inches) above the weather deck;(2) A hatch in a cabin top; and(3) A hatch on a vessel that operates only on protected waters. Multiple gaskets on hatches leading to the bilge were degraded, worn out, and non-functional, as evident by the excess accumulation of water in the bilge. Replace with new gaskets and pump out bilges, to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 27 January 2022
Resolution: Because of non availability of gasket material, operator temporary using gasket sealant for hatch covers.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 May 2016 Resolved
AWM01 Replace/repair waterlight to standard - Vessels waterlight batteries were expired and required to be replaced by manufacturer at least every two years.
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 11 May 2016
Resolution: Corrected on the spot with new batteries.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 May 2016 Resolved
AWM02 Provide proof of enrollment in Drug/Alcohol testing program.
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 19 May 2016
Resolution: Provided proof of enrollment as per attached letter (see activity 5873888) dated June 7, 2011 from [name withheld]
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 May 2016 Resolved
AWM03 Provide maintenance records attesting to the successful indication of bilge alarm in W Rake. West rake visual and audible alarms were not indicating on screen at operator’s station.
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 31 May 2016
Resolution: Received maintenance record attesting to the successful indication of bilge alarm in W Rake.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 11 May 2016 Resolved
AWM04 Post additional instructions for operation of fixed fire extinguishing system at pull box.
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 19 May 2016
Resolution: Instructions posted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 11 May 2016 Resolved
AWM05 Replace breakglass enclosure for remote controls on fixed fire system.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 19 May 2016
Resolution: Brek glass replaced
Documentation › Certificates/Documents › Permit, Other
Issued 11 May 2016 Resolved
AWM06 Provide proof of Marine Operator Permit for on board VHF Radio. 47 CFR 80.159 (e)
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 19 May 2016
Resolution: Vessel uses UHF, Operators license not required.
Electrical › Electric Supply System (service) › Cable
Issued 12 March 2010 Resolved
BW02 Properly terminate or remove dead-end wiring in machinery space. 46CFR183.340
Condition: Improper/Lack of Maintenance
Due 19 March 2010
Resolved 17 March 2010
Resolution: The wire was completely removed by Farnham Electric on March 17, 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 12 March 2010 Resolved
BW03 Remove or properly repair deck light in vicinity of head. 46CFR183.340
Condition: Damaged By Earlier Event
Due 19 March 2010
Resolved 17 March 2010
Resolution: The light fixture was completely replaced by Farnham Electric on March 17, 2010.
Lifesaving › Lifebuoys › Serviceable
Issued 12 March 2010 Resolved
BW01 Renew life ring buoy with proper replacement. 46CFR180.70
Condition: Improper/Lack of Maintenance
Due 13 March 2010
Resolved 17 March 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 March 2008 Resolved
Install new floating line on ring buoy, 60ft long.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 13 May 2008
Resolution: Replaced line.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 March 2008 Resolved
Make repairs to bilge alarm system, fax service invoice to USCG Portland, Or office. make round of bilge spaces at least every one hour of operation, log results.
Action required: 705 - Other - as specified
Due 17 April 2008
Resolved 13 May 2008
Resolution: Replaced alarm system components.
Engineering › Electric Propulsion System › Contactor
Issued 13 November 2006 Resolved
Port and starboard main motor controllers repeatedly shut down due to overheating. Install new motor controllers and prove proper operation to attending Coast Guard Inspector. Correct prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2006
Resolved 5 December 2006
Resolution: Installed new main motor controllers. Tested sat.
Engineering › Freshwater System (intermediary cooling) › Hose
Issued 3 March 2005 Resolved
Renew antifreeze cooling flexible hose. 46CFR182.720.
Due 3 April 2005
Resolved 28 June 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 March 2005 Resolved
Provide retroreflective tape on ring buoy. 46CFR185.604.
Due 3 April 2005
Resolved 28 June 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 March 2004 Resolved
Complete servicing of CO2 system and fax report to MSO Portland, OR
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2004
Resolution: Received fax copy of servicing report, sat. Curt Farrell, MSO Portland, OR.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2004 Resolved
two of the four life ring waterlight cap fasteners are missing and need to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2004
Resolution: Received a fax from Senior Ferry operator [name withheld] stating that he had replaced the waterlight fasteners, sat. Curt Farrell, MSO Portland, OR.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 May 2003 Resolved
Demonstrate operation of alarm, pressure switch, time delay, fan and louver shut down for fixed CO2 system in engine room. LEGACY COMPONENT DESC: Operating Controls
Due 21 June 2003
Resolved 23 June 2003
Resolution: Witnessed satisfactory operational testing of all shutdowns for fixed CO2 system.
Accommodation/Occupational Safety › Medical/First Aid
Issued 21 May 2003 Resolved
Renew expired items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 21 June 2003
Resolved 23 June 2003
Resolution: Verified all expired items in the kit were renewed.
Communications › Alarms/Indicators
Issued 21 May 2003 Resolved
Demonstrate operation of alarm panel. Until this item is completed, hourly rounds of the engine room and fuel tank space must be made and logged. LEGACY COMPONENT DESC: Lube Oil Low Pressure Alarm
Due 21 June 2003
Resolved 23 June 2003
Resolution: Verified proper operation of alarm panel by testing of high water alarms and smoke/heat detectors.
Communications › Alarms/Indicators
Issued 5 April 2002 Resolved
Repair and prove operation of installed alarm system. Until this item is completed, vessel must operate with engine room door open and hourly rounds of fuel tank space must be made and logged. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Unknown
Due 12 April 2002
Resolved 12 April 2002
Electrical › Electrical Distribution System (service)
Issued 5 April 2002 Resolved
Correct ground fault indication on main switchboard. LEGACY COMPONENT DESC: Switchboard
Due 12 April 2002
Resolved 12 April 2002
Engineering › Non-conventional Propulsion/Steering
Issued 28 March 2002 Resolved
Modify propulsion motor enclosures to prevent water spray from hitting electrical connections or enclosures.
Condition: Design Flaw
Due 5 April 2002
Resolved 5 April 2002
Resolution: Installed separation barrier between motor and pulleys (around shafts).
Personnel › Training
Issued 28 March 2002 Resolved
Demonstrate crew competence in all vessel systems. LEGACY COMPONENT DESC: Familiarization Training
Due 5 April 2002
Resolved 5 April 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 28 March 2002 Resolved
Provide and post instructions for fixed CO2 firefighting system.
Due 5 April 2002
Resolved 5 April 2002
Documentation › Certificates/Documents › Stability Letter
Issued 28 March 2002 Resolved
Post Stabiliy Letter in pilothouse.
Due 5 April 2002
Resolved 5 April 2002
Communications › Alarms/Indicators
Issued 28 March 2002 Resolved
Prove operation of audible alarm for all installed alarms. LEGACY COMPONENT DESC: Fire Alarm
Condition: Placed in Improper Service
Due 5 April 2002
Resolved 5 April 2002
Engineering › Fuel Oil Service System › Pump
Issued 28 March 2002 Resolved
Demonstrate 24VDC to 110VAC inverter for fuel pump (start diesel generator without shore tie).
Condition: Design Flaw
Due 5 April 2002
Resolved 5 April 2002
Documentation › Markings/Placards
Issued 28 March 2002 Resolved
Modify and post emergency instructions in pilot house.
Due 12 April 2002
Resolved 5 April 2002
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 28 March 2002 Resolved
Conduct fire and man overboard drill in the presence of a Coast Guard inspector.
Due 5 April 2002
Resolved 5 April 2002
Operations/Management › Navigation Safety
Issued 28 March 2002 Resolved
Demonstrate procedure for generator failure while underway (vessel's ability to reach either shore without propulsion power). LEGACY COMPONENT DESC: Navigation Underway, General
Due 5 April 2002
Resolved 5 April 2002

Casualty record · 2

1 February 2009Routine · role: Involved in a Marine Investigation (non-casualty) · activity 3413616
25 April 2014Routine · role: Involved in a Marine Casualty · activity 4862422
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.