MAURY USCG vessel records
← All vessels

MI-JO II

Built
2002
Last inspected
12 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 May 2026
Operational controls 1 with no removal date recorded
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA7765
512351
Flag
UNITED STATES
Maury page id
psix-512351

Documentation record

Registered dimensions (L × B × D)65.0 ft × 19.0 ft × 6.2 ft
Registered tonnagegross 51 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYANK MARINE INC · TUCKAHOE, NJ, UNITED STATES · built 2002
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portATLANTIC HIGHLANDS, NJ
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 9 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Simplified, Gross Ton
41 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

12 May 2026 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8370963
27 April 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8356878
25 February 2026 Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8310630
10 June 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8156581
23 April 2025 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8118039
13 May 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7911137
19 March 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7881459
4 March 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7873734
10 May 2023 Annual Survey · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7685517
11 May 2022 Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7447349
3 February 2022 Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7390961
11 May 2021 Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7194081
2 June 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6965891
21 January 2020 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6893383
13 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6689717
9 January 2019 Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6653370
7 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6576308
8 May 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6408756
25 April 2017 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6131785
16 March 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6104206
5 May 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5869368

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 May 2026 Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. MI observed maximum fire pump pressure gauge reading of 38 psi. Repair gauge or provide evidence that the pump is capable of producing the required throughput of 50 gallons per minute. 46 CFR 181.300(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 21 May 2026
Resolution: Received video of satisfactory test of fire pump.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2026 Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, each hose must:(1) Be lined commercial fire hose that conforms to UL 19 (incorporated by reference, see 46 CFR 175.600) or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent in performance;(2) Be 15.25 meters (50 feet) in length and 40 millimeters (1.5 inches) in diameter; and(3) Have fittings of brass or other suitable corrosion-resistant material that comply with NFPA 1963. MI observed pinhole on towards hydrant end of fire hose. Replace fire hose to the satisfaction of MI. 46 CFR 181.320(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 21 May 2026
Resolution: Received video of satisfactory test of fire pump, as well as photos of newly installed hose.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 June 2025 Resolved
System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system. Bulkhead penetration between engine room anf fuel void is not sealed. 46CFR181.410(a)(3)
Action required: 10 - Deficiency Rectified
Resolved 11 June 2025
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 May 2024 Resolved
Chart aboard vessel was found not up to date. 46 CFR 185.420 As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible;
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 17 May 2024
Resolution: O/O provide photos of up to date charts intended for voyage aboard vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2024 Resolved
Currency of alcohol testing devices were out of date. 46 CFR 4.06-15(a)(1) The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 20 May 2024
Resolution: O/O provided picture of new alchol testing devices with an expiration of 31JAN2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 May 2024 Resolved
EPIRB registration was expired. O/O provided proof of new registration through e-mail (see attached).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 May 2024
Resolution: Deficiency was resolved on 13 MAY 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel did not complete credit drydock inspection which was due by 29 FEB 2024. Vessel will need to complete drydock inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2024
Resolution: Completed Credit Drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2023 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. Several lights on child's lifejackets were inoperable. Replace as necessary. 46 CFR § 180.75 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2023
Resolved 26 May 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 February 2022 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry dock examination and an internal structural examination at least once every two year. The last dry dock and internal structure exam was conduct February 10, 2020. A dry dock and internal structure exam must be conducted prior to passenger.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2022
Resolution: Conducted dry dock and ISE, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 June 2020 Resolved
Provide proof of SOLAS grade retro tape currently installed on lifebuoys and lifefloats, replace as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 June 2020
Resolution: All SOLAS approved tape installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 January 2020 Resolved
Provide repair plan for hull plate replacement in lazzarette near bilge suction prior to credit drydock.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2020
Resolution: Replaced plating in lazarette
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 January 2020 Resolved
Clean and provide a gauging report for hull platting along centerline under deck platting in #2 space prior to credit drydock
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 February 2020
Resolution: Cleaned and clad welded identified areas in #2 space
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 May 2019 Resolved
Tested CO2 system engine shut downs and alarms, pressure switches failed to shut down all engines and activate audible alarm. Vessel must prove proper operation of alarm and shut down devices. 46CFR181.410 (b)(10)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2019
Resolution: Witnessed proper operation of engine shutdowns and alarm.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 November 2018 Resolved
Vsl is broadcasting incorrect Name, Vsl is broadcasting incomplete dimension information (AIS Antenna Position "X" equals 0) and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 June 2020
Resolution: AIS Tech cleared AIS errors.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 April 2017 Resolved
MMSI number needs to be programed into VHF Radio
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 27 April 2017
Resolution: Installed MMSI into readio.
Engineering › Bilge Water Management System › Not Operational
Issued 25 April 2017 Resolved
Bilge suction in steering gear space/laz is not working. Vessel limited to carrying no more than 49 pax until fixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 April 2017
Resolution: Fixed stuck check valve on bilge piping. Tested sytem for suction succesfully.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 April 2017 Resolved
COI needs to be posted in area accessible to passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 27 April 2017
Resolution: Mounted COI un glass in main cabin in view of all customers.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 5 May 2016 Resolved
Vessel did not meet the ground detection requirements of 46CFR183.324(c). Vessel must istall ground detection.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 16 June 2016
Resolution: Vessel installed appropriate ground detection monitor and panel. (See photos).

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.