Records from 2016 to 2026. Most recent: inspection, 28 May 2026.
Inspection history · 30
28 May 2026
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8380950
25 November 2025
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8273389
16 May 2025
PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8135645
6 November 2024
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8029191
30 April 2024
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7902001
30 October 2023
PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7816294
4 April 2023
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7662322
5 October 2022
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7572891
17 September 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7560759
3 September 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7550016
18 April 2022
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7433033
1 April 2022
PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7422742
28 September 2021
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7312916
15 June 2021
Deficiency Check · PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7225693
4 May 2021
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7188836
6 April 2021
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7168721
12 November 2020
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7093993
16 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7078420
2 October 2020
PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7066720
24 March 2020
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6930854
11 February 2020
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6907030
25 September 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6820619
27 March 2019
Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6650105
7 October 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6555537
5 April 2018
ISPS III Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6386477
5 October 2017
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6280545
6 April 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6118077
1 October 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6010532
30 March 2016
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5843847
24 March 2016
ISPS III Exam · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5839841
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 May 2026
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection including fire-resisting divisions, and protection of openings and penetrations in those divisions. The gaskets installed in the fire doors in the oil purifier room, engineer store, emergency escape trunk on platform 8600, the paint store, and the BOSN store are heavily deteriorated or dry rotted and do not maintain the fire boundary requirements.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 June 2026
Resolution: CLASS REPORT WAS RECEIVED FROM BV
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 28 May 2026
Resolved
All life - saving appliances and arrangements shall comply with the applicable requirements of the Code. the normal equipment of every lifeboat shall consist of: watertight receptacles containing a total of 3 L of fresh water for ach person the lifeboat is permitted to accommodate... The freefall lifeboat can accommodate a total of 20 persons and should carry a total of 60 L of fresh water, but is only provided with 24L of fresh water.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 June 2026
Resolution: CLASS REPORT WAS RECEIVED FROM BV
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2026
Resolved
Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. Guard rail and stanchion located port side at cargo hold #3 are severely damaged.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 June 2026
Resolution: CLASS REPORT WAS RECEIVED FROM BV
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 May 2026
Resolved
... On ships carrying at least two search and rescue dry locating devices and equipped with free-fall lifeboats one of the search and rescue locating devices shall be stowed in a free-fall lifeboat and the other located in the immediate vicinity of the navigation bridge... The ship is equipped with a free-fall lifeboat but both SARTS were stowed on the navigation bridge.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 June 2026
Resolution: CLASS REPORT WAS RECEIVED FROM BV
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 May 2026
Resolved
Rescue boats shall be stowed: in a stat of continuous readiness for launching n not more than 5 min... The crew took longer than minutes to start the rescue boat engine.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 June 2026
Resolution: CLASS REPORT WAS RECEIVED FROM BV
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 6 November 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. During annual maintenance, company identified the pelican hook for the free fall lifeboat had major deterioration and needed to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2024
Resolved 4 December 2024
Resolution: Received Class Report attesting to the repairs fo the Pelican hook.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 30 October 2023
Resolved
tHE ANGULAR POSITION OF THE RUDDER SHALL BE RECOGNIZEABLE IN THE STEERING GEAR COMPARTMENT. DURING STERAING GEAR TEST PSCO OBSERVED RUDDER INCDICATOR REPEATER DEVIATED FIVER DEGREES.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 15 November 2023
Resolution: Repairs done by shore technicians with replaced new poteniometers. Operational testcarried out and found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 30 October 2023
Resolved
The condiction of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all repsects will remain fit to proceed to sea without danger to the ship or persons onboard. During deck walk PSCO identified a hole in maitenance deck air pipe on port side near by 15.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2023
Resolved 15 November 2023
Resolution: The air pipe in question was replaced with new section; length of 3500mm. inspected under working pressure and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2023
Resolved
Fire-fighting systems and appliances shall be kept in good working order and ready for immediate use. 04 fire hoses were observed by PSCO to not be in proper working order with leaks identified.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 October 2022
Resolved
Before the ship leaves port at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO's observed failure of the rescue boat engine to start within the allotted timeframe of five minutes on three separate occasions.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2022
Resolution: Vessel replaced rescue boat engine with a new outboard motor approved by Class.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 1 April 2022
Resolved
A safety management certificate shall be issued to every ship by the Administration or an Organization recognized by the Administration. Ships ISM-SMC was expired. Ship has surveys scheduled for next port. 74 SOLAS 2020 cons CH IX Reg 4.3
Action required: 15 - Rectify deficiencies by next port
Resolved 2 April 2022
Resolution: Class issued 1 month extension on ISSC
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 1 April 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. Ship could not demonstrate proper operation of the oily water separator. MARPOL 73/78 2011 Cons Annex I Reg 6.4.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2022
Resolution: Received report of survey from class.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 April 2022
Resolved
Ships shall be maintained in compliance with the mechanical requirements of a class society. PSCO observed an air leak on an air line that supplies the secondary starting charge cylinder for the Emergency Generator. 74 SOLAS 04 Cons CH II-1 Reg 3-1.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 April 2022
Resolution: Received report of survery from Class.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 September 2021
Resolved
The fire damper shall operate automatically but shall also be capable of being closed manually from both sides of the bulkhead or deck. The fire dampers located in the purifier room were incapable of closing manually - 74 SOLAS (2001) II-2/48 - 10C
Action required: 10 - Deficiency Rectified
Resolved 28 September 2021
Resolution: PSCO verified fire dampers located in the purifier room. All was found in proper working order. Deficiency Cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 September 2021
Resolved
Where the emergency source of electrical power is a generator, unless a second independent means of starting the emergency generator is provided the single source of stored energy shall be protected to preclude its complete depletion by the automatic starting system. PSCO identified cross over valve open from the emergency air supply tank to the main. 74 SOLAS (2004) II-1/43.3.1.2 - 10c
Action required: 10 - Deficiency Rectified
Resolved 28 September 2021
Resolution: PSCO verified cross over valve from the emergency air supply tank to the main was closed. All was found in proper working order. Deficiency Cleared.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 September 2021
Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed no change shall be made in the structural arrangements, machinery, equipment without the sanction of the administration. Thermal oil cabinet located in the engine room that control quick closing valves for this system have been disabled by the crew. 74 SOLAS(2020) I/11(b) 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 30 September 2021
Resolution: MSD LW received and accepted BV survey report attesting to the corrective action taken with the thermal oil system/heater. Deficiency Cleared.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 15 June 2021
Resolved
All external high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high-pressure line failure. A jacketed pipe incorporates an outer pipe into which the high-pressure fuel pipe is placed, forming a permanent assembly. The jacketed piping system shall include a means for collection of leakages and arrangements shall be provided with an alarm in case of a fuel line failure. The Port Main Diesel Engine leakage alarm was found inoperative and in alarm since 21May2021 - 74 SOLAS (2001 Cons) Ch II-2/15.2.9 - 30ac
Action required: 30 - Ship detained
Resolved 18 June 2021
Resolution: Repairs were made to the satisfaction of Class and the CG. See the class survey reports in docs for details.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 June 2021
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. No fuel oil leaks shall be situated where spillage or leakage therefore can constitute a hazard by falling on heated surfaces. The port main diesel engine secondary duplex fuel filters were found excessively leaking fuel. The port main diesel engine crankcase breather discharge was found routed into a five gallon bucket with approximately 2.5 gallons of fuel in it located outboard side of the engine. A fuel oil leak was discovered on the governors for both main engines, which then drained into two five gallon buckets. The main engines’ fuel supply lines had a temporary repair that was leaking and being collected in a five gallon bucket. The fuel module system in the purifier room is leaking from the relief valve and being captured into drum then transferred to the number 40 overflow tank via portable pump. Cardboard was found to be placed around the fuel oil leaks on the main engines’ governors; the pieces of cardboard were saturated with fuel oil creating an extreme fire hazard. Portable buckets and drums were found throughout the engine room nearly completely full from the collection of leaking fuel oil.- 74 SOLAS (2001 Cons) Ch II-2/15.2 - 30ac
Action required: 30 - Ship detained
Resolved 18 June 2021
Resolution: Repairs were made to the satisfaction of Class and the CG. See the class survey reports in docs for details.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2021
Resolved
All electrical apparatuses shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. PSCO identified exposed wires forward of anchoring arrangements on the bow of the main deck - 74 SOLAS (2004 Cons) Ch II-1/45.1.3 - 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 18 June 2021
Resolution: Repairs were made to the satisfaction of Class and the CG. See the class survey reports in docs for details.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 15 June 2021
Resolved
The Oil Record Book Part I shall be completed on each occasion, on a tank-to-tank basis if appropriate, whenever any of the following machinery space operations takes place in the ship: collection and disposal of oil residues (sludges). The oil residue/ sludge that was found to be leaking from the main engines was not recorded in the Oil Record Book - MARPOL 2017 ANNEX I/17.2.3 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2021
Resolution: Repairs were made to the satisfaction of Class and the CG. See the class survey reports in docs for details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The central sea water cooling pipe for both main engines was found to be leaking then collected, piped to the vessel’s bilge pocket, and subsequently to the slop tanks via portable pump - 74 SOLAS (2020 Cons) Ch 1/11(a) - 30ac
Action required: 30 - Ship detained
Resolved 18 June 2021
Resolution: Repairs were made to the satisfaction of Class and the CG. See the class survey reports in docs for details.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 15 June 2021
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements, which may be established by the company. In meeting these requirements, the company should ensure that: the inspections are held at appropriate intervals; any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. PSCOs collected objective evidence that the vessel was not identifying non-conformities and following the inspection and reporting requirements of its SMS. An external audit conducted by the Flag is required within 30 days to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port - 74 SOLAS (2014 Cons) Ch IX/Reg 3.1 ISM Code Part A Reg 6.4 10.2.2, 5.1.5, and 9.1 - 30ac
Action required: 30 - Ship detained
Resolved 18 June 2021
Resolution: Repairs were made to the satisfaction of Class and the CG. See the class survey reports in docs for details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Spring loaded gate valves on the #33 & 34 lube oil tanks were tied open and unable to be automatically closed - 74 SOLAS (2020 Cons) Ch 1/11(a) - 30ac
Action required: 30 - Ship detained
Resolved 18 June 2021
Resolution: Repairs were made to the satisfaction of Class and the CG. See the class survey reports in docs for details.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 June 2021
Resolved
Fire extinguishers shall be situated ready for use. Portable extinguishers which have been discharged shall immediately be recharged or replaced with an equivalent unit. Fire extinguisher #23 in the engine room is low on pressure and therefore not in compliance. - 74 SOLAS (2020 Cons) Ch II-2/10.3.2.4 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2021
Resolution: Repairs were made to the satisfaction of Class and the CG. See the class survey reports in docs for details.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 15 June 2021
Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable Type II device. Vessels marine sanitation device type II chemical treatment system is inoperable - 33 CFR 159.7(a)(1) - 10c
Action required: 10 - Deficiency Rectified
Resolved 15 June 2021
Resolution: PSCO Verified corrective action taken by shipboard personnel and witnessed an satisfactory test the the marine sanitation device type II. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 April 2021
Resolved
The following fire protection systems shall be kept in good order so as o ensure required performance if fire occurs; structural fire protection and protection of openings. Emergency escape door frame located in the lower level engine room has wastage compromising fire integrity. - 74SOLAS(2014) 11-2/14.2.1.1 - 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 4 May 2021
Resolution: Received class report and accepted this correspondence from [name withheld] stating " Emergency escape door frame located in lower engine room was replaced with new". MSD Lake Worth has accepted this report and deficiency is cleared.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 October 2020
Resolved
service spaces protected by class A-0 doors must be self closing at all levels. The Galley an laundry class A-0 doors do not self close. 74 Solas (01) 11-2/46.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 16 October 2020
Resolution: recieved proper documentatin from technician and chief engineer
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020
Resolved
Piping systems shall be of construction adequate for the service for which they are intended and should be installed and protected to reduce danger to persons on board due to hot surfaces and other hazards. The fuel service line in the purifyer room is kincked and multiple lagging pieces are missing. 74 Solas (04) II-1/26.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 16 October 2020
Resolution: recieved proper documentation from technician and chief engineer
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2020
Resolved
Machinery installations shall be protected to reduce any danger to persons on board with due regard to hazards. 05 oil buckets are in the engine room, shaft seal is full of oil in the bilge, forward bilge on star/port full of oily water. Bilge alarm not functioning. 74 Solas (04) II-1/26.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2020
Resolved 16 October 2020
Resolution: Recieved proper documentatoin from technician and chief engineer
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 March 2016
Resolved
FSD bewteen changing room and engine room has a closing mechanism which prevents the door from being secured and will not stay closed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 April 2016
Resolved 30 March 2016
Resolution: FSD fixed and functioning properly.