Records from 1982 to 1999. Most recent: inspection, 17 December 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
17 December 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812132
25 June 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1127880
7 May 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130162
2 January 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398817
20 March 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1102534
6 February 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363950
4 January 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446284
10 February 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440906
10 March 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389780
21 May 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412530
31 July 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469742
27 March 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 954772
22 March 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243865
7 November 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229393
12 April 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211840
31 March 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344774
29 April 1988
Hull Examination · COI Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344445
17 November 1987
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1332818
13 April 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007159
21 April 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302505
5 November 1985
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985260
5 November 1985
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995716
7 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283165
2 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972949
22 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278895
10 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975562
3 May 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967436
Electrical
Issued 6 February 1997
Resolved
REPACK WIRING CONNECTIONS FOR THE BATTERY BOXES AND PILOTHOUSE THROUGH HULLCONNECTIONS
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Construction/Loadline
Issued 6 February 1997
Resolved
CROP AND RENEW FLANGE PLATING IN WAY OF THE STBD RUDDER STOCK WHERE PITTED AND WASTED
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Engineering
Issued 6 February 1997
Resolved
MAKE AIR RECEIVERS IN ENGINE ROOM AVAILABLE FOR INTERNAL EXAM OR HYDROSTATIC TESTING.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Engineering
Issued 6 February 1997
Resolved
PROVE PROPER OPERATION OF OVERSPEED SHUTDOWNS FOR BOTH MDEs.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Accommodation/Occupational Safety
Issued 6 February 1997
Resolved
RELOCATE AND SECURE WASHER AND DRYER. PRESENTLY LOCATED IN CREW'S MESS, STBD SIDE IN WAY OF DRY STORES
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Construction/Loadline
Issued 6 February 1997
Resolved
MAKE PERMANENT REPAIR TO BILGE DISCHARGE PIPING IN THE ENGINEROOM WHERE SOFT PATCH INSTALLED
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Lifesaving
Issued 6 February 1997
Resolved
MAKE PERMANENT REPAIR TO RESCUE BOAT ON THE STBD QUARTER WHERE CORNER BRACKET WHERE BROKEN.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Engineering
Issued 2 May 1984
Resolved
MAKE PERMANENT REPAIRS TO TACHOMETERS ON BOTH MAIN ENGINES AND DEMONSTRATE PROPER OPERATION OF OVERSPEED TRIPS ON BOTH MAIN ENGINES.
Condition: Unknown
Due 2 May 1984
Resolved 2 May 1984
Unknown
Issued 2 May 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE M/V LULU TIDE, O.N. 620317.
Condition: Unknown
Due 2 May 1984
Resolved 2 May 1984
Deck/Cargo
Issued 10 November 1983
Resolved
PROVIDE STARBOARD ANCHOR
Condition: Unknown
Due 10 November 1983
Resolved 10 November 1983
Unknown
Issued 10 November 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL LULU TIDE, DN620317
Condition: Unknown
Due 10 November 1983
Resolved 10 November 1983
Unknown
Issued 3 May 1982
Resolved
PROVIDE APPROVED PLANS & TEST PROCEDURES FOR THE NEWLY INSTALLED MACHINERY SPACE MONITORING/ALARM SYSTEM FOR REDUCED ENGINEROOM MANNING
Condition: Unknown
Due 3 May 1982
Resolved 3 May 1982