WILLKATE

Built
1980
Last inspected
20 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI7291
Flag
UNITED STATES
Maury page id
psix-51239

Documentation record

Registered dimensions (L × B × D)64.9 ft × 18.4 ft × 6.7 ft
Registered tonnagegross 61 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMILFORD, DE, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBALTIMORE, MD
Endorsements, as the file codes themcw_un
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 26 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

20 March 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8331724
2 February 2026 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8304923
14 January 2026 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8296415
11 April 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8112670
29 January 2024 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7864427
23 March 2023 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7671016
15 March 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7651586
5 December 2022 Examination of Repairs · Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7604523
5 December 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7609425
4 April 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7424041
7 December 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7375514
15 July 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7257385
4 May 2021 Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7189081
19 March 2021 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7159413
5 February 2021 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7136351
27 January 2021 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7131861
10 September 2020 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7055423
21 July 2020 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7011375
8 May 2019 Administrative Inspection · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6679414
28 February 2019 Damage Survey · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6635819
8 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6504741
1 July 2018 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6468366
19 July 2017 Simplified Stability Test
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6214237
16 June 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6177853
18 May 2016 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5874850
1 March 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6005412

Deficiency record · 37

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 January 2024 Resolved
46 CFR 58.25-10(c)(1) The auziliary steering gear must be of being brought speedily into action in an emergency. Current cargo loading arrangements allow for stowage on access hatch to steering gear compartment. Update stowage arrangements to allow access at all times.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2024
Resolution: Amended COI for carriage of 18 portable IBC totes and not allow stowage on steering compartment.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 January 2024 Resolved
46 CFR 171.124(b) Each hatch cover must have securing devices and be attached to the hatch frame or combing by hinges, captive chains, or other devices to prevent loss. None of the vessel hatch covers were appropriately attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 February 2024
Resolution: Recieved documentation that scuttle capture chains have been reinstalled.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 January 2024 Resolved
46 CFR 98.33-9 Each portable tank must be secured to the vessel by devices of sufficient strength and number to prevent the tank from moving in any direction during transport. L-bracket holding tanks in place have multiple weld fractures and need to be repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2024
Resolution: Weld repairs made to L brackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 March 2023 Resolved
A vessel must be provided with bilge pumps…each fixed power bilge pump must be self priming. It must be permanently connected to the bilge manifold. Fixed bilge pump not working properly at time of attendance. Unable to dewater the forepeak space when tested. *Portable bilge pump placed onboard and its functionality demonstrated to attending CG MIs prior to completion of inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 20 April 2023
Resolution: The pump was replaced with a brand new pump. Attending MI observed a satisfactory dewatering test of forepeak space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 March 2023 Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. Isolation valve for the bilge piping in the forepeak is stuck in the open position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 20 April 2023
Resolution: Isolation valve replaced and confirmed working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 March 2023 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance shall be in working order and readily available for immediate use. The port side lifebuoy found with a wasted/holed plug.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 20 April 2023
Resolution: Two new ring buoys provided onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 March 2023 Resolved
The frame or support of each semi-portable fire extinguisher must be welded or otherwise permanently attached to a bulkhead or deck. The 160B semi-portable extinguisher is missing the bracket/attachment that prevents it from shifting/rolling.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 20 April 2023
Resolution: Securing bracket added to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 March 2023 Resolved
At each inspection for certification, periodic inspection, and at other times necessary, the inspector will determine that all fire-extinguishing equipment is in suitable condition. The fire hose has a small leak through the jacket and needs to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2023
Resolved 20 April 2023
Resolution: Existing fire hose replaced with brand new 1.5 inch UL 19 fire hose. Attending MI observed satisfactory pressure test of the new fire hose while onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 March 2023 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance shall be in working order and readily available for immediate use. Most lifejacket lights found with January 2022 expiry date.
Action required: 10 - Deficiency Rectified
Due 15 March 2023
Resolved 15 March 2023
Resolution: Vessel rep replaced the 6 expired lifejacket lights prior to completion of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 December 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel operator reported a Loss of Propulsion to the vessel due to a broken shaft. 46 CFR 182.100
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 January 2023
Resolution: Shaft was replaced and a visual inspection and sea trial were conducted. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 April 2022 Resolved
Vessel should be equipped with independently driven fire pumps. Fire pump leaking excessively from impeller/coupling area. Poses electric shock hazard. Update 4/4/22 PM: extended deficiency due date two weeks and permitted vessel operations based on satisfactory functional test of portable fire pump to be used as a temporary measure. Updated 4/29: extended deficiency an additional two weeks.
Action required: 60 - Rectify deficiencies prior to movement
Due 4 April 2022
Resolved 11 May 2022
Resolution: Attending MI confirmed that newly installed/replaced fire pump functions satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 April 2022 Resolved
At every vessel inspection, the bilges may be examined to see that there is no excessive accumulation of oil in the bilge. Excessive oil in the bilge. To be removed.
Action required: 60 - Rectify deficiencies prior to movement
Due 4 April 2022
Resolved 4 April 2022
Resolution: CG MI re-attended and confirmed that excess oil in the bilge had been satisfactorily removed (it was vacued out).
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 April 2022 Resolved
A vessel on Lakes, Bays, Sounds route must carry 3 hand orange smoke and 3 hand red flares, or substitutions under (c). All flares expired.
Action required: 10 - Deficiency Rectified
Due 4 April 2022
Resolved 4 April 2022
Resolution: Vessel operator provided 6 new flares onboard prior to completion of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 April 2022 Resolved
A visual and audible high water alarm shall be provided at the operating station. Forepeak high water audible/visual alarm inop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 29 April 2022
Resolution: Attending marine inspector observed satisfactory functional test of high water alarm for forepeak.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 April 2022 Resolved
A vessel must carry a first aid kit approved under 160.041. Various contents of first aid kit expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 29 April 2022
Resolution: Attending marine inspector sighted new first aid kit materials onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2022 Resolved
Propulsion machinery must be suitable for the installation. Shaft missing protective guard near access ladder in compartment aft of the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 29 April 2022
Resolution: Attending marine inspector sighted protective guard properly installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 April 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 4 April 2022
Resolved 22 September 2022
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 April 2022 Resolved
A vessel must be provided with bilge pumps in accordance with 182.520 (a). Bilge pump is not functioning properly and cannot take suction to dewater the forepeak when tested. Update 4/4/22 PM: extended deficiency due date two weeks and permitted vessel operations based on satisfactory functional test of portable fire pump to be used as a temporary measure. Updated 4/29: extended deficiency an additional two weeks.
Action required: 60 - Rectify deficiencies prior to movement
Due 4 April 2022
Resolved 11 May 2022
Resolution: Attending MI confirmed that newly installed/replaced bilge pump functions satisfactorily and is able to dewater the forepeak space.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 July 2020 Resolved
Escape scuttle from engine room missing opening device on interior side. Replace handle and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2020
Resolved 30 July 2020
Resolution: Handle installed on scuttle. Picture accepted of repair.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 July 2020 Resolved
VHF radio does not have required GPS input. Program radio to include GPS input.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 10 August 2020
Resolution: Radio now receives GPS input. Picture of repair accepted.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 July 2020 Resolved
No emergency lighting present in crew space. Install emergency lighting in crew space near steps from engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 10 September 2020
Resolution: Emergency lighting installed. Received and accepted email and video from operator.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 July 2020 Resolved
The sidelights of a power-driven vessel shall be placed at least one meter lower than the forward masthead light. They shall not be so low as to be interfered with by deck lights. The masthead light and sidelights are on the same plane. Provide proposal for creating required vertical separation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 30 July 2020
Resolution: Mast head light raised above plane of sidelights. Picture accepted of repair.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 July 2020 Resolved
Vertical sectors of electric lights shall ensure that at least the minimum intensity is maintained at all angles from 5 degrees above to 5 degrees below the horizontal. Port sidelight mounting is no longer horizontal. Make repairs to mounting to ensure light is horizontal and unobstructed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 30 July 2020
Resolution: Sidelight frame repaired. Pictures accepted of repair.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 July 2020 Resolved
Sternlight minimum intensity shall be maintained over the arc of the horizon; stern light is obstructed by exhaust piping mid sector. Provide proposal to ensure full arc of stern light visibility.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 30 July 2020
Resolution: Stern light located aft of the engine stack and no longer obstructed. Picture accepted of repair.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2020 Resolved
Aft battery in engine room has termination that is failing. Make connection with captive style connector appropriate for size of conductor and post. Forward battery has a post with greater than 4 terminations. Provide proposal for reducing terminations on a single post to 4 or less.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 30 July 2020
Resolution: Terminations reduced on battery post. Picture accepted of repair.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2020 Resolved
Junction box on aft part of superstructure has a broken stuffing tube. Replace box cover to restore watertightness.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 30 July 2020
Resolution: Junction box repaired. Picture accepted of repair.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 May 2019 Resolved
The fwd end of the port side containment area is wasted through. Vessel must complete a satisfactory repair to ensure proper containment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 May 2019 Resolved
The forward white mast light is working intermittently and its bracket weld is broken. Make proper repairs to the light and bracket and prove proper operation to attending CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2019 Resolved
Identify bilge high level alarm that is not marked on the bridge console.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 28 May 2019 Resolved
The fire pump discharge must be fitted with a pressure gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 28 May 2019 Resolved
The fire pump shall be available for use at all times. The current arrangement does not allow the operation of a separate fire and bilge pump at all times.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2019
Resolved 13 February 2020
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 28 May 2019 Resolved
The vessel shall have a rudder angle indicator at the principle steering station.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 June 2019
Resolution: Tested the rudder angle indicator.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 May 2019 Resolved
The auxiliary steering gear (tiller) must be proven to operate with the vessel's crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2019 Resolved
Install a suitable bilge strainer having an open area of not less than three times that of the suction pipe on the lazarette bilge pick-up.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2019
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 February 2019 Resolved
Make permanent repairs to the rudder where it connects to the shaft. Vessel restricted from carrying cargo or passengers until repairs have been made and sea trials conducted, to the satisfaction of the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2019
Resolution: Effective repairs made to satisfaction of attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 February 2019 Resolved
Make permanent repairs to the vessel prop. Proper repairs must be completed by shop and a report myst be sent to the CG attesting to repairs made.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2019
Resolution: Received satisfactory repair report.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 August 2018 Resolved
Vsl is broadcasting: Invalid Call Sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 September 2018
Resolved 10 September 2020
Resolution: Operator updated AIS unit. Verified correct broadcast information with NAVCEN.