Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)65.0 ft × 15.0 ft × 7.0 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderT. H. B INC · FERNANDINA, FL, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 8 April 2026 · expires 31 May 2027
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton 36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 18 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 19 March 2025Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following:
Discharge of Oil Prohibited ...
No Discharge of oil Prohibited Placard on board
33 CFR 155.450(a) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 26 March 2025
Resolution: Marpol placard obtiane and on board
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 19 March 2025Resolved
Monthly extinguisher checks - Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
No monthly fire extinguisher checks completed or logged.
46 CFR 31.10-18(a)(2)
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 28 March 2025
Resolution: Updated log book, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 March 2025Resolved
Flame arresters must be of a type and size suitable for the purpose intended and meet ASTM F 1273.
No flame arrestors below oil filters in engine room.
46 CFR 32.20-10
16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 28 March 2025
Resolution: Moved to DD worklist item
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 March 2025Resolved
Each cargo pump within a pump-room must have a discharge pressure gauge outside the pumproom.
Unable to read pressure gauge on deck second cargo pump
46 CFR 153.333
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 26 March 2025
Resolution: All preassure gauges on cargo pumps replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 April 2021Resolved
All vessels except unmanned barges shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment except for ballast, oil, and water tanks which have acceptable means for filling and emptying independent of the bilge system.
46CFR56.50-50(a)(1)
Repair or replace bilge pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2021
Resolved 22 April 2021
Resolution: Operator discovered bilge pump was wired incorrectly. Rewired and tested sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 February 2018Resolved
COI expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2018
Resolved 22 February 2018
Stability › Watertight Integrity › General
Issued 13 January 2017Resolved
provide repair proposal for hull in way of bottom portion of engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2017
Resolved 24 January 2017
Resolution: All repairs were made to the satifaction of attending MI.
Stability › Watertight Integrity › General
Issued 13 January 2017Resolved
provide UT ratings for starboard side at midship.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2017
Resolved 24 January 2017
Resolution: All repairs were made to the satifaction of attending MI.
Stability › Watertight Integrity › General
Issued 13 January 2017Resolved
provide UT ratings for bow thruster.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2017
Resolved 24 January 2017
Resolution: No repairs were necessary to the bow thruster area.
Engineering › Lubricating Oil Service System › Hose
Issued 29 February 2016Resolved
Secure hydraulic leak located on forward spud.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 23 March 2016
Resolution: Hydraulic leak was secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 23 March 2016
Resolution: Nav lighting was properly terminated.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.