MAURY USCG vessel records Sign in
← All vessels

PETERSON 1

PETERSON 1 is a 2002 tank ship. The Coast Guard has recorded 48 inspections since 2002, most recently in April 2026, along with 78 deficiencies and 1 operational control.

Records from 2002 to 2026. Most recent: inspection, 8 April 2026.

Built
2002
Last inspected
8 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7781
512446
Flag
UNITED STATES
367076860 (licence lapsed)
Maury page id
psix-512446

Inspections, by type

…with no type recorded14
Years with a record 22 calendar years (2002–2026)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 15.0 ft × 7.0 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderT. H. B INC · FERNANDINA, FL, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 April 2026 · expires 31 May 2027
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC7781MMSI 367076860 · expired · voluntarily equipped · granted 15 November 2005, cancelled 16 January 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 48

8 April 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8345309
19 December 2025 Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8285751
14 June 2025 Security Breach
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8160599
26 March 2025 Examination of Repairs · Drydock Exam · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8099815
19 March 2025 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8096555
5 April 2024 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890351
15 February 2023 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7637018
25 May 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7489633
30 March 2022 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7421662
13 April 2021 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7174694
18 August 2020 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7038062
11 March 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6924418
5 March 2020 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6920941
25 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6627911
22 February 2018 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6354360
30 March 2017 MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6122794
13 January 2017 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6069733
29 February 2016 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5823742
27 August 2014 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4967666
30 June 2014 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4908484
26 June 2014 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4905966
4 May 2012 MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4304070
8 March 2010 Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3690293
17 March 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3434033
31 October 2008 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3355402
13 December 2007 COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3113493
21 February 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2588808
6 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2509746
27 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2502301
11 August 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2458904
13 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2425451
21 June 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2397604
18 June 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2394281
8 June 2005 MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2386394
14 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2333548
28 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2300450
13 January 2005 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2274074
3 January 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2267909
25 August 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2176075
8 January 2004 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2195665
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2013902
17 December 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1965817
12 December 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1963320
19 November 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1952237
28 May 2003 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1803785
16 May 2003 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1794849
17 October 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1690898
7 February 2002 Initial Construction-Excluding Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1484867

Deficiency record · 78

14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 19 March 2025 Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following: Discharge of Oil Prohibited ... No Discharge of oil Prohibited Placard on board 33 CFR 155.450(a) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 26 March 2025
Resolution: Marpol placard obtiane and on board
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 19 March 2025 Resolved
Monthly extinguisher checks - Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. No monthly fire extinguisher checks completed or logged. 46 CFR 31.10-18(a)(2) 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 28 March 2025
Resolution: Updated log book, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 March 2025 Resolved
Flame arresters must be of a type and size suitable for the purpose intended and meet ASTM F 1273. No flame arrestors below oil filters in engine room. 46 CFR 32.20-10 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 28 March 2025
Resolution: Moved to DD worklist item
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 March 2025 Resolved
Each cargo pump within a pump-room must have a discharge pressure gauge outside the pumproom. Unable to read pressure gauge on deck second cargo pump 46 CFR 153.333 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 26 March 2025
Resolution: All preassure gauges on cargo pumps replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 April 2021 Resolved
All vessels except unmanned barges shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment except for ballast, oil, and water tanks which have acceptable means for filling and emptying independent of the bilge system. 46CFR56.50-50(a)(1) Repair or replace bilge pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2021
Resolved 22 April 2021
Resolution: Operator discovered bilge pump was wired incorrectly. Rewired and tested sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 February 2018 Resolved
COI expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2018
Resolved 22 February 2018
Stability › Watertight Integrity › General
Issued 13 January 2017 Resolved
provide repair proposal for hull in way of bottom portion of engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2017
Resolved 24 January 2017
Resolution: All repairs were made to the satifaction of attending MI.
Stability › Watertight Integrity › General
Issued 13 January 2017 Resolved
provide UT ratings for starboard side at midship.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2017
Resolved 24 January 2017
Resolution: All repairs were made to the satifaction of attending MI.
Stability › Watertight Integrity › General
Issued 13 January 2017 Resolved
provide UT ratings for bow thruster.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2017
Resolved 24 January 2017
Resolution: No repairs were necessary to the bow thruster area.
Engineering › Lubricating Oil Service System › Hose
Issued 29 February 2016 Resolved
Secure hydraulic leak located on forward spud.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 23 March 2016
Resolution: Hydraulic leak was secured.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 February 2016 Resolved
Properly secure navigation light wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 23 March 2016
Resolution: Nav lighting was properly terminated.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 May 2012 Resolved
Replace water light to ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 May 2012 Resolved
Properly mount retroreflective tape on ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 May 2012 Resolved
Service all portable fire extinguishers, the wheeled B-V, and provide service technician documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 7 May 2012 Resolved
Replace the outlet hydraulic hose from the MDE gear driven pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Engineering › Lubricating Oil Service System › Hose
Issued 7 May 2012 Resolved
Replace the hydraulic hose fwd of the aux engine from the operation station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 7 May 2012 Resolved
Install the turbo filter housing on the MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Electrical › Electric Supply System (service) › Cable
Issued 7 May 2012 Resolved
Remove the battery cables from the bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2012 Resolved
Provide a first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Engineering › Bilge Water Management System › Manifold
Issued 7 May 2012 Resolved
Properly label the bilge dewatering system manifold.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 May 2012 Resolved
Install a insulated boot/guard over bilge pump electrical connections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Air Silencer
Issued 7 May 2012 Resolved
Install hose on the aux engine air intake manifold.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 7 May 2012 Resolved
Hydro-test conduit transfer hose, relief valve, and cargo piping. Provide procedures of test to sector Miami prior to scheduling follow up inspection and test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 7 May 2012 Resolved
Label transfer hoses in IAW 33CFR155.800 and 33CFR154.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 7 May 2012 Resolved
Provide a cargo pump gauge for each cargo pump IAW 46CFR32.50-5.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 May 2012 Resolved
Provide all original vessel documents onboard vessel. Ensure updated copies of the VSP and VRP onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 7 May 2012 Resolved
Completed the VSP exercise assessment and include comments as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2008 Resolved
Scale down area of hull IWO bow thruster propeller and make available for USCG inspection.
Action required: 705 - Other - as specified
Due 11 November 2008
Resolved 11 November 2008
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2008 Resolved
Provide gauging report (hull area) for 3"-4" ban IWO bow thruster propeller.
Action required: 705 - Other - as specified
Resolved 11 November 2008
Stability › Watertight Integrity › General
Issued 31 October 2008 Resolved
Make all watertight hatches watertight to the satisfaction of attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 11 November 2008
Stability › Watertight Integrity › General
Issued 31 October 2008 Resolved
Submit proposal for seal around cargo tanks.
Action required: 705 - Other - as specified
Resolved 7 November 2008
Stability › Watertight Integrity › General
Issued 13 December 2007 Resolved
Make collision bulkhead watertight
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 27 December 2007
Engineering › Lubricating Oil Service System › Hose
Issued 13 December 2007 Resolved
Make proper repair to leak on Bow thruster hydraulic hose.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 27 December 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 December 2007 Resolved
Properly secure for sea gear in fwd peak.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 27 December 2007
Engineering › Lubricating Oil Service System › Hose
Issued 13 December 2007 Resolved
Make proper repair to leaking hydraulic hose in tank void IVO ladder.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 27 December 2007
Stability › Watertight Integrity › General
Issued 13 December 2007 Resolved
Make aft bulkhead in tank void watertight.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 27 December 2007
Engineering › Lubricating Oil Service System › Hose
Issued 13 December 2007 Resolved
Make proper repairs to leaking hydraulic hoses in tank void stbd side forward.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 11 November 2008
Engineering › Fuel Oil Service System › Filter
Issued 13 December 2007 Resolved
Provide plug on flame bowl for Aux. generator.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 31 January 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 December 2007 Resolved
Make repairs to exhaust leak on MDE.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 8 February 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 December 2007 Resolved
Clean out debris in steering gear void bilge.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 27 December 2007
Communications › Alarms/Indicators › Rate of Turn Indicator
Issued 13 December 2007 Resolved
Make repairs to Aux generator RPM gauge.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 31 January 2008
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2007 Resolved
Provide fixed ballast plan.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 27 December 2007
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2007 Resolved
Provide Stability (deadweight survey) MSC approval letter.
Action required: 705 - Other - as specified
Due 27 December 2007
Resolved 27 December 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 7 March 2006 Resolved
Provide explosive gas and oxygen indicator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 February 2006 Resolved
Service date past due on BV service or replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2006
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 21 February 2006 Resolved
Remove oil soaked rags from cargo void and engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 21 February 2006 Resolved
Remove wood decking from engine room bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2006
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 21 February 2006 Resolved
Provide proper test certificate for cargo piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 21 February 2006 Resolved
Repair/replace light fixutre in engine room.
Due 21 March 2006
Resolved 7 March 2006
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 21 February 2006 Resolved
Provide proper sight glass tubing for fuel tanks.
Due 21 March 2006
Resolved 10 March 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 February 2006 Resolved
Service past due on one BII, propely service or replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 February 2006 Resolved
Provide missing support brackets for exhaust piping steering gear compartment.
Due 21 March 2006
Resolved 7 March 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 February 2006 Resolved
Present vessel for annual exam no later than 17 JAN 06.
Due 21 February 2006
Resolved 21 February 2006
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 21 February 2006 Resolved
Provide pre-employment background testing for personnel enrolled in drug testing program and proof of MIS submission.
Due 21 March 2006
Resolved 7 March 2006
Engineering › Bilge Water Management System › Piping
Issued 21 February 2006 Resolved
Prove proper operation of bilge dewateing system.
Due 21 March 2006
Resolved 7 March 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 21 February 2006 Resolved
Repair excessive leak in lower crank case located on the port side engine.
Due 5 March 2006
Resolved 7 March 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 January 2005 Resolved
Provide metal support for overhead electrical wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 8 February 2005
Construction/Loadline › Penetrations › Weld
Issued 13 January 2005 Resolved
Missing weld under side of deck fittings for fuel and hydraulic tank vents.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 14 January 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 January 2005 Resolved
All electrical splices must be in an enclousure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 8 February 2005
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 13 January 2005 Resolved
Provide chaffing protrection under fixed lead ballast in forward compartment,
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 14 January 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 13 January 2005 Resolved
Repair hydraulic leakage in cargo pump room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 8 February 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 January 2005 Resolved
Rearrange electrical termination at starter solenoid.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 14 January 2005
Stability › Watertight Integrity › General
Issued 13 January 2005 Resolved
Repair bolts at watertight hatch at port side engine space.
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 14 January 2005
Engineering › Bilge Water Management System › Pump
Issued 13 January 2005 Resolved
Demonstrate proper operation of fixed bilge system in all compartments.
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 14 January 2005
Engineering › Steering Gear System › Actuator
Issued 13 January 2005 Resolved
Reinstall and prove proper operation of steering actuator on both sides.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 January 2004 Resolved
Provide original COI onboard.
Due 8 February 2004
Resolved 14 January 2004
Personnel › Certificates/Documents/Licenses › License, Master
Issued 8 January 2004 Resolved
Provide original Masters licenses on board.
Due 8 February 2004
Resolved 14 January 2004
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 January 2004 Resolved
Provide logs of drills and training showing topics and each person attending.
Due 8 February 2004
Resolved 14 January 2004
Stability › Intact Righting Energy › General
Issued 8 January 2004 Resolved
Re-stow lead ballast in proper place.
Due 8 February 2004
Resolved 14 January 2004
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 8 January 2004 Resolved
Provide documentation of annual cargo piping and transfer hose test.
Due 8 February 2004
Resolved 14 January 2004
Documentation › Markings/Placards › Warning Signs
Issued 8 January 2004 Resolved
Locate vessel warning signs to be visible at all times.
Due 8 February 2004
Resolved 14 January 2004
Personnel › Training › Familiarization Training
Issued 8 January 2004 Resolved
The vessel crew shall be one Master and one crew person until all Masters prove compentency to operate all vessel systems.
Due 8 February 2004
Resolved 14 January 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 8 January 2004 Resolved
Provide an additional ventalation duct for pump room.
Due 8 February 2004
Resolved 14 January 2004
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 8 January 2004 Resolved
Provide tide and current tables onboard.
Due 8 February 2004
Resolved 14 January 2004
Pollution Prevention/Response › Response Equipment › Protective Clothing
Issued 8 January 2004 Resolved
Provide combustible gas indicator onboard.
Due 8 February 2004
Resolved 14 January 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 January 2004 Resolved
Provide a explosition proof portable light onboard.
Due 8 February 2004
Resolved 14 January 2004
Engineering › Bilge Water Management System › Pump
Issued 8 January 2004 Resolved
Remove submersible electrical pump from pump room or prove safe for space.
Due 8 February 2004
Resolved 8 January 2004
Engineering › Bilge Water Management System › Not Operational
Issued 8 January 2004 Resolved
Prove proper operation of fixed bilge system prior to further transfer operations.
Due 8 February 2004
Resolved 14 January 2004

Ownership record