CAPTAIN RON

CAPTAIN RON is a 1980 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in March 2026, along with 14 deficiencies and 1 casualty investigation in 2014.

Records from 2014 to 2026. Most recent: inspection, 30 March 2026.

Built
1980
Last inspected
30 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF 5422
Flag
UNITED STATES
Maury page id
psix-51253

Documentation record

Registered dimensions (L × B × D)108.7 ft × 24.6 ft × 3.3 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSWIFTSHIPS INC · MORGAN CITY, LA, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

30 March 2026 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8320323
22 April 2025 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8117058
4 September 2024 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7996365
20 May 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7917129
19 October 2023 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7811656
9 May 2022 Annual Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7446582
1 February 2022 Type not recorded
No type recorded · USCGC TIGER SHARK (WPB 87359) · USCG Heartland District (CGD-H) · Activity 7392239
13 August 2021 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7285649
27 July 2021 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7271373
19 July 2021 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7260820
23 July 2020 COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7013555
13 May 2020 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6952460
1 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6825535
19 June 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6448519
4 June 2018 Drydock Exam · Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6433942
30 October 2017 Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6338015
4 October 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6281419
19 October 2016 Type not recorded
No type recorded · USCGC STURGEON (WPB 87336) · USCG Northeast District (CGD-NE) · Activity 6033546
27 June 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5921697

Deficiency record · 14

09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 May 2025 Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover, guard, or rail. Missing guards on port and center main diesel engine. Renew with guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 20 May 2025
Resolution: Vessel rep provided photo evidence of machinery quards in place on STBD and Center MDE's, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2025 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel has bilge pumps with a fire pump as secondary. Fire pump operates at 70psi, but was not able to test suction for bilge. Have bilge and piping cleaned and tested at next drydock: 31MAY2026.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2026
Resolved 12 August 2026
Resolution: Sector NOLA issued new def for requirement. Closing out to reduce multiple defs of the same requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 June 2022 Resolved
The master of the vessel shall ensure the EPIRB battery is replaced before the date required by FCC regulations. EPIRB battery was expired. Vessel is restricted to 3NM from shore until cleared. 46 CFR 185.728 46 CFR 180.40-1 (OLD T) 46 CFR 185.25-20 (OLD T)
Action required: 705 - Other - as specified
Resolved 7 June 2022
Resolution: New EPIRB purchased
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 June 2022 Resolved
Each EPIRB must be tested monthly and shall be logged or otherwise documented. Vessel only had record of past two months of EPIRB tests logged. 46 CFR 185.728
Action required: 10 - Deficiency Rectified
Resolved 3 June 2022
Resolution: EPIRB tests logged
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2022 Resolved
Circuit breakers and fuses shall be examined visually to determine suitability for service intended. Circuit breaker had an open space without a blank installed. 46 CFR 176.25-15 (OLD T)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2022
Resolution: Blank installed
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 August 2021 Resolved
Repairs or alterations to the hull...that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks...On August 13, 2021, the [name withheld] collided with the barge WEB 323, causing an approximate 12" crack at the main deck/side shell corner plating, thus effecting the vessels watertight integrity and seaworthiness of the vessel. The vessel shall proceed as requested to Broussard Brothers in Intracoastal City, LA to perform necessary repairs to gain necessary watertight integrity. Repairs shall be made to the satisfaction of the local OCMI.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2021
Resolution: Received objective evidence of satisfactory repair to stbd aft corner of the main deck and sideshell weld. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 July 2021 Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Both remote fuel shutoff valves were not labeled and were missing direction of operation arrows. Vessel shall permanently label both remote fuel shutoff valves and label direction of operation by arrows or other appropriate means. 46 CFR 185.30-20(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 27 July 2021
Resolution: Received satisfactory objective evidence photo documentation from vessel rep showing both remote fuel shutoffs labeled and direction of operation arrows indicated.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 July 2021 Resolved
All ducts for spaces containing machinery shall be of rigid permanent construction of fire proof material and reasonably gastight from end to end. The ducts shall lead as direct as possible and be properly fastened and supported. Ventilation closures for the stbd side engine room were inoperable. Vessel shall make ventilation closures for the stbd side engine room operable. 46 CFR 182.20-45(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 27 July 2021
Resolution: Received satisfactory objective evidence photo documentation from vessel rep showing stbd side vent closure for engine room operable.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 July 2021 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. All four bilge indicator lights on board vessel were inoperable. Vessel shall repair/ replace all four bilge indicator lights. 46 CFR 182.530(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2021
Resolved 28 July 2021
Resolution: Received satisfactory objective evidence photo documentation from vessel rep showing all four bilge indicator lights operable.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 July 2021 Resolved
Bilges and other spaces must not have accumulation of oil or other matter which might create a fire hazard. Bilges in engine room were found to have significant oily water accumulation. Vessel shall remove oily water accumulation in engine room bilges. 46 CFR 176.25-50(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 28 July 2021
Resolution: Received satisfactory objective evidence photo documentation from vessel rep showing receipt that bilges were cleaned of oily water accumulation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 July 2021 Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance to salt water, petroleum oils, heat and vibration, may be used. Such hose shall overlap metallic pipe ends at least 1.5 times the pipe diameter and shall be secured at each end by two hose clamps of corrosion resistant metal. Vessel was missing double hose clamp on fuel fill line. Vessel shall install a second hose clamp on the fuel fill line. 46 CFR 182.20-30(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 27 July 2021
Resolution: Received satisfactory objective evidence photo documentation from vessel rep showing double hose clamp installed on fuel fill line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2021 Resolved
All life preservers shall be marked with the vessel's name. Two life jackets were not labeled with the name of the vessel. Vessel shall label two life jackets with name of vessel. 46 CFR 180.25-15(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2021
Resolved 27 July 2021
Resolution: Received satisfactory objective evidence photo documentation from vessel rep showing two PFD's labeled with vessel name.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 October 2019 Resolved
Vessels operated more than 100 nautical miles but not more than 200 nautical miles from the nearest land must be equipped with a VHF-DSC radiotelephone installation. GPS was not connected to the VHF radio, rendering the DSC alert function unable to send position information.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2019
Resolved 1 October 2019
Resolution: Vessel corrected deficiency on the spot
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2016 Resolved
Vessel completed unapproved hull repairs and failed to notify Coast Guard that repairs were conducted.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2016
Resolution: [name withheld] verified repairs and issued hull amendment

Casualty record · 1

19 January 2014Routine · role: Involved in a Marine Casualty · activity 4797276
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.