Records from 2016 to 2025. Most recent: inspection, 8 January 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)72.1 ft × 24.0 ft × 9.5 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNICHOLS BROTHERS BOAT · VANCOUVER WA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
8 January 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8060323
14 December 2023
COI Inspection · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7838796
9 December 2022
Deficiency Check · Examination of Repairs · Inclining Experiment · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7606817
8 November 2022
SIP Inspection/Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7584355
15 July 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7507702
10 November 2021
Administrative Inspection · Deficiency Check · Annual Inspection · SIP Inspection/Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7349817
25 March 2021
In-Service Inspection · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7162635
29 January 2021
Deficiency Check · Annual Inspection · SIP Inspection/Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7132917
6 January 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7120288
21 November 2019
Administrative Inspection · Annual Inspection · SIP Inspection/Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6859977
1 May 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6674409
20 December 2018
Administrative Inspection · Annual Inspection · SIP Inspection/Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6600483
11 December 2018
Damage Survey · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6596188
10 December 2018
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6599170
30 November 2017
COI Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6308436
1 November 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection · Construction Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6025546
19 October 2016
Annual Inspection · Administrative Inspection · SIP Inspection/Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6025149
25 July 2016
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5952835
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Discovered multiple dead end wires under the helm console. Remove the dead end wires, prior to credit drydock, to the satisfaction of the MI.
46 CFR 120.200 (b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 June 2025
Resolution: Operator submitted photos of finished wiring, see documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child-size life jackets equal to at least 10% of the number of persons permitted on board must be provided. Identified two child and two adult life jackets that were damaged beyond repair. Life jackets were replaced during the inspection.
46 CFR 117.71 (a & b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 January 2025
Resolution: Lifejackets were replaced during inspection.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 December 2023
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Operation of the fire main system and checking of the pressure at the most remote and highest outlets. Vessels fire main found weeping from a cracked weld during operational testing.
46 CFR 115.810(a)(3)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2023
Resolved 10 January 2024
Resolution: Temporary repair completed-granted 2 week extension for holiday down time.
Weld repair completed and pressure tested.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 December 2023
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Emergency light cage broken by port side boarding door.
46 CFR 120.410
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 December 2023
Resolution: Received picture of corrected E light cage.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 December 2023
Resolved
Portable fire extinguishers must be refilled when the net content weight loss exceeds that specified for fixed systems Table 115.810(b). Portable fire extinguisher found with pressure gauge in the red.
46 CFR 115.810(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2023
Resolution: A new fire extinguisher was delivered at the end of the inspection.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 14 December 2023
Resolved
After loading and prior to departure, and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's stability letter. Upper decks were found marked with passengers counts in excess of those allowed by the current stability letter.
46 CFR 122.315(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 December 2023
Resolution: Received picture of corrected deck passenger signage.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 December 2023
Resolved
Each buoyant apparatus must have Type II retro reflective material meeting subpart 164.018. BA missing retro reflective material.
46 CFR 160.10(p)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 December 2023
Resolution: Received corrected picture of BA SOLAS tape.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 14 December 2023
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Medical certificates must be issued and will remain current for the following periods of time, unless otherwise noted on the certificate. Captain was missing MMC medical card.
46 CFR 15.401(c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 March 2024
Resolution: Mariner relieved of duty.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 December 2023
Resolved
Life jackets may be continued to be used if they are maintained in good and serviceable condition. Life jacket found to be torn.
46 CFR 180.71(d)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 14 December 2023
Resolution: Replaced torn life jacket with new life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 December 2023
Resolved
Each survival craft must be; Stowed in a way that neither the survival craft nor its stowage arrangements will interfere with the embarkation and operation. IBA line tied incorrectly to the weak link.
46 CFR 117.130 (a)(2)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 14 December 2023
Resolution: IBA Line was correctly tied to the weak link.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 June 2023
Resolved
The cognizant Officer in Charge, Marine Inspection (OCMI) determines the total number of persons permitted to be carried on a vessel. In determining the total number of persons, the OCMI may consider the total weight of passengers, crew, and variable loads; stability restrictions and subdivision requirements of the vessel; the vessel's route, general arrangement, means of escape, and lifesaving equipment; minimum manning requirements; and the maximum number of passengers permitted in accordance with § 115.113 of this subpart. Vessel is limited to 50 passengers on the third (02) deck and 100 (01) passengers on the second deck.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 October 2023
Resolution: Recieved new stability letter from MSC.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 June 2023
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Vessel has exceeded allowable limit on weight changes since the last stability evaluation. Vessel shall conduct new stability testing and obtain new stability letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2023
Resolved 6 October 2023
Resolution: recieved new stability letter from MSC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Relocated emergency fuel shutoff valve pull cables to be tested.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2023
Resolution: Newly installed shutoffs tested satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 8 November 2022
Resolved
At each inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspections of the hull structure including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Identified 3" crack in overhead of main deck with temp patch in place and no documented Correction Report. Make permanent repairs at next credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2022
Resolved 17 May 2023
Resolution: Repairs made to the satisfaction of attending MI.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 November 2022
Resolved
A Coast Guard marine inspector will conduct required periodic and follow-on inspections necessary to ensure compliance with Coast Guard regulations. Certain components of company action plan lists inspection intervals at daily/monthly/quarterly (steering/lifesaving/firefighting) that are not being documented.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 14 December 2023
Resolution: Vessel removed from SIP in 2023.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. 46 CFR 120.200(c) Improper splice was found by MI on FWD 12v battery, port side E/R. Repair, and make new. 46 CFR 120.200(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2021
Resolved 29 November 2021
Resolution: Received photo of repaired wire.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 November 2021
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected the cognizant OCMI may conduct an internal structural examination in any affected space... and to effect permanent repairs. Holes and corrosion were discovered above port main engine exhaust in overhead. Provided plan proposal to MI for permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2021
Resolved 17 May 2023
Resolution: Repairs made to the satisfaction of the attending MI.