Records from 2016 to 2025. Most recent: inspection, 13 May 2025.
Inspection history · 12
13 May 2025
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8134843
16 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909645
9 May 2023
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684779
29 April 2022
Drydock Exam · Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7450138
30 April 2021
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7186317
2 August 2020
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7018610
26 June 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6719074
22 October 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6566171
21 May 2018
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6415541
12 May 2017
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6152506
9 March 2017
Drydock Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6100750
26 April 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5862758
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 May 2025
Resolved
Each life jacket must be marked with type 1 retroreflective material. MI found 04 lifejackets with wasted retroreflective material. Replace to MI satisfaction.
46 CFR 185.604(h)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 16 May 2025
Resolution: Submitted photo evidence of replaced retro tape, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil.. MI discovered excessive oil in the engine room bilge. Clean to MI satisfaction.
46 CFR 176.830(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 16 May 2025
Resolution: Submitted photo evidence of a cleaned engine room bilge, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 May 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its certificate of inspection giving consideration to provisions for a seaworthy hull. MI discovered signs of decayted wood in lazarette on stbd stern weatherdeck. Provide repair plan and effect repairs to MI satisfaction.
46 CFR 177.100
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 23 May 2025
Resolution: Completed satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections if the hull structure including the following, inspection of accessible parts of the exterior and interior hull. The vessel has an abnormal leak in the underwater body in way of the aft most transverse frame supporting the hull planking behind the port rudder post. Submit a repair proposal to the satisfaction of the Marine Inspector. Complete permanent repair prior to 2025 operating season.
46 CFR 176.802(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2024
Resolved 9 July 2024
Resolution: Temporary repair proposal completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including operation of the main propulsion machinery. Vessel’s stbd me wet exhaust was found to be leaking.
46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 9 July 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 May 2024
Resolved
Each hatch exposed to the weather must be watertight. Vessel’s laz hatch is not fully watertight.
46 CFR 179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 9 July 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2024
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Wing nuts found on battery terminals on both the Port/stbd batteries in the engine room.
46 CFR 183.350(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 9 July 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 16 May 2024
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Aft port hole's/windows of the main seating area found with no covering.
46 CFR 177.1020
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2024
Resolved 9 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2023
Resolved
Main steering gear must be of adequate strength. One mounting bolt of steering gear was loose and missing hardware causing movement when operating. Owner shall replace and tighten mounting bolt.
46 CFR 182.610(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 May 2023
Resolution: Owner replaced bolt/hardware and tested system satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 17 May 2023
Resolved
An exposed hazard, such as gears on rotating machinery must be properly protected by a cover, guard, or rail. Vessels STBD engine was missing a machinery guard over the inboard pulley. Vessel shall install guard for safety of crew.
46 CFR 177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 31 May 2023
Resolution: Operator installed guard on engine pulley.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 29 April 2022
Resolved
The master shall conduct sufficient drills and give sufficient instructions during emergencies that necessitate abandon ship or recovery of persons who have fallen overboard. Owner did not want to get underway due to high wind advisory. Vessel shall provide satisfactory man overboard drill to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 24 May 2022
Resolution: Operator conducted successful man overboard drill for attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires in tank space. Remove dead end wires.
46 CFR 183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 June 2021
Resolution: Operator removed dead end wires.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 April 2021
Resolved
On a vessel of at least 26 feet (7.9 meters) in length, a visual and audible alarm must be provided at the operating station to indicate a highwater level in each of the following unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from the sea water piping within the space. High water alarm was inoperable in the engine room.
Action required: 10 - Deficiency Rectified
Resolved 30 April 2021
Resolution: Operator replaced high water alarm during the inspection.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 June 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List, tide tables and current tables. Vessles chart was out of date and missing several navigation publications. Update required navigation publications.
46 CFR 184.420 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 11 July 2019
Resolution: Operator submitted email including photos of current updated charts and most current nautical publications.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 June 2019
Resolved
A vessel must carry either a first aid kiet approved under approval series 160.041 or a kit with equivalent contents and instructions. Aspirin in the kit was expired. Replace aspirin in vessels first aid kit.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 10 July 2019
Resolution: Operator sent photos showing new aspirin in first aid kit.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 June 2019
Resolved
46 CFR 176.25-5 - At each initial and subsequent inspection the marine inspector shall examine all accessible part of the hull. Sections of the lining or ceiling may be removed or the parts otherwise probed or exposed so that the marine inspector may be satisfied to the condition of the hull structure. Wood rot witnessed along internal of vessel transom and along port beams within engine room. Vessel must have all wood rot removed and effected areas repaired at next dry dock in November 2019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 6 August 2020
Resolution: Corrected.
Lifesaving › Lifefloat › Pendant
Issued 21 May 2018
Resolved
Replace life float pendants IAW 46CFR160.010-4(g).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Photo documentation/ materials receipt provided.
Engineering › Bilge Water Management System › Not Operational
Issued 21 May 2018
Resolved
Replace bilge water high level audible alarm.
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Photo documentation/ part invoive provided.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 21 May 2018
Resolved
Clean port & stbd fuel strainer for main engines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Photo documentation provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2018
Resolved
Complete first aid kit.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Photo documentation provided.
Construction/Loadline › Structures › Door
Issued 21 May 2018
Resolved
Properly secure stern access hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2018
Resolved 29 May 2018
Resolution: Photo documentation provided.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 21 May 2018
Resolved
Either make the bilges/deck hatches watertight or complete new stability test (as an open boat) prior to the AY19 operating season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 6 August 2020
Resolution: Issued in error. Vessel has watertight bulkhead.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 12 May 2017
Resolved
Provide 2 BII and 1 BI fire extinguishers as per COI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 9 June 2017
Resolution: Received photo documentation for correction.
Fire Fighting › Fire Bucket › Availability
Issued 12 May 2017
Resolved
Provide 3 fire buckets properly labeled on board.
Condition: Invalid
Due 12 June 2017
Resolved 9 June 2017
Resolution: Received photo documentation for correction.