Records from 1981 to 2004. Most recent: inspection, 24 March 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
24 March 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2030279
18 March 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2026652
10 May 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1791850
10 May 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2024580
7 April 2003
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1769817
10 May 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1614975
4 April 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460502
12 April 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469621
29 March 1999
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468041
14 May 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 666493
29 April 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409902
12 March 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 215414
16 February 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 196834
7 March 1997
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364003
1 July 1996
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1095365
13 March 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 667445
17 October 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 665873
11 October 1995
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878418
9 October 1995
Permit to Proceed
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1363397
8 October 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 48605
8 October 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 182814
17 March 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1374246
13 March 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446183
20 May 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 859661
3 May 1994
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1374054
27 September 1993
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1154277
4 May 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 827393
22 April 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 826392
6 September 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1218549
19 November 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931988
9 November 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911069
9 November 1989
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 924050
19 October 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1285351
8 August 1989
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1280688
21 October 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890817
10 February 1988
Hull Examination · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1333188
2 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017642
21 October 1987
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1326363
15 July 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022816
25 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327058
30 October 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324742
7 November 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292836
9 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297288
21 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984238
24 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974100
24 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275707
25 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277788
22 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966133
Personnel › Certificates/Documents/Licenses
Issued 10 April 2003
Resolved
Provide proof that one member of the crew has a radio operator permit. LEGACY COMPONENT DESC: License, FCC Radio Operator
Action required: 705 - Other - as specified
Due 10 May 2003
Resolved 14 April 2003
Personnel › Certificates/Documents/Licenses
Issued 10 April 2003
Resolved
Provide proof of license for one mate, the vessel is restricted to operations of less than twelve hours. LEGACY COMPONENT DESC: License, Mate
Action required: 705 - Other - as specified
Due 10 May 2003
Resolved 14 April 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 April 2003
Resolved
Repair the main engine shut downs in the pilothouse. LEGACY COMPONENT DESC: Shut Down
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 14 April 2003
Fire Fighting › Grease Extraction Hood
Issued 10 April 2003
Resolved
Provide a filter and a light cover for the range hood. LEGACY COMPONENT DESC: Filter
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 14 April 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 10 April 2003
Resolved
Provide sea rails for the galley stove. LEGACY COMPONENT DESC: Stove
Action required: 705 - Other - as specified
Due 10 May 2003
Resolved 14 April 2003
Engineering › Fuel Oil Service System
Issued 10 April 2003
Resolved
Replace the fuel hose on the stbd. generator. LEGACY COMPONENT DESC: Hose
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 14 April 2003
Engineering › Fuel Oil Service System
Issued 10 April 2003
Resolved
Remove all petcocks from the RAYCOR filters and provide plugs or petcocks that will accept a plug. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 10 May 2003
Resolved 14 April 2003
Electrical › Lighting (emergency)
Issued 10 April 2003
Resolved
Repair the emergency light for the switchboard. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2003
Resolved 14 April 2003
Communications › Radio Communications
Issued 9 May 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 10 June 2002
Resolved 14 April 2003
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 May 2002
Resolved
RINGBOUYS NOT MARKED WITH HOMEPORT.
Due 10 May 2002
Resolved 10 May 2002
Fire Fighting › Fire Main › Condition
Issued 9 May 2002
Resolved
FIREMAIN PIPING FRACTURED AND LEAKING WATER INTO ENGINEROOM BILGES.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2002
Resolved 10 May 2002
Construction/Loadline
Issued 17 March 1995
Resolved
WELD DECK INSERTS ABOVE PORT AND STARBOARD MAIN ENGINES.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Lifesaving
Issued 17 March 1995
Resolved
PROVIDE ONBOARD A RESCUE PLATFORM.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Engineering
Issued 17 March 1995
Resolved
PROVIDE PULLEY GUARD FOR STARBOARD MAIN ENGINE.
Condition: Unknown
Due 17 March 1995
Resolved 17 March 1995
Construction/Loadline
Issued 3 May 1994
Resolved
PROPERLY ADJUST PORTSIDE BRIDGE WATERTIGHT DOOR AND INSTALL GROMMETS IN BULKHEAD FOR WIRES.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Engineering
Issued 3 May 1994
Resolved
INSTALL PROTECTION GUARDS OVER COMPRESSOR BELTS.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Construction/Loadline
Issued 3 May 1994
Resolved
WELD AREA ON OVERHEAD ABOVE THE STARBOARD MAIN ENGINE.
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Navigation
Issued 4 May 1993
Resolved
RELOCATE NAVIGATION STERN LIGHT TO COMPLY WITH THE REQUIREMENTS OG CURRENT COLREGS.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Electrical
Issued 4 May 1993
Resolved
RESUBMIT ELECTRICAL INSTALLATION PLANS FOR APPROVAL IN ACCORDANCE WITH G- MSC-2 LETTER E-10115 OF 05MAR91 AND PROVIDE APPROVED TO LOCAL MARINE INSPECTOR FOR VERIFICATION.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Navigation
Issued 24 February 1984
Resolved
REPAIR OR REPLACE DEFECTIVE STERN LIGHT FIXTURE (LOOSE SOCKET BASE).
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Unknown
Issued 24 February 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL KELLIE CHOUEST DN601477
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Fire Fighting
Issued 24 February 1984
Resolved
PROVIDE THREE CLOSED CLAMP TYPE FIRE EXTINGUISHER BRACKETS.
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Unknown
Issued 24 February 1984
Resolved
PLACE FLAME SCREEN ON SEWAGE TANK GOOSENECK VENT.
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984