MAURY USCG vessel records Sign in
← All vessels

BEAVER ISLANDER

BEAVER ISLANDER is a 1962 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1985, most recently in May 2026, along with 46 deficiencies and 5 casualty investigations between 2012 and 2024.

Records from 1985 to 2026. Most recent: inspection, 14 May 2026.

Built
1962
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WT5906
Flag
UNITED STATES
366936060
Maury page id
psix-51273

Inspections, by type

…with no type recorded11
Years with a record 38 calendar years (1985–2026)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)87.2 ft × 27.2 ft × 8.3 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTURGEON BAY SHIPBUILDING · STURGEON BAY, WI, UNITED STATES · built 1962
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST JAMES, MI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 15 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3269MMSI 366936060 · active · compulsorily equipped · granted 23 April 2025, expires 23 April 2035
WT5906MMSI 366936060 · expired · compulsorily equipped · granted 3 April 2014, cancelled 24 August 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 86

14 May 2026 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8392683
28 June 2025 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8212328
15 May 2025 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8172464
25 June 2024 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7965804
18 April 2024 Hull Examination · Damage Survey · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7911233
18 March 2024 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7882589
18 March 2024 Damage Survey · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7882997
11 September 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7814603
16 June 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7721613
18 May 2023 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7701816
6 June 2022 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7470069
10 May 2022 MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7437385
13 October 2021 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7331631
20 April 2021 MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7180153
29 October 2020 Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7087277
19 October 2020 Damage Survey · Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7082629
13 August 2020 Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7031644
11 August 2020 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7031667
2 April 2020 In-Service Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6934580
16 May 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6685942
17 May 2018 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6420990
8 May 2018 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6408763
27 February 2018 Plan Review (Other than "T")
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6399669
1 November 2017 Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6314195
20 June 2017 Damage Survey · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6184391
9 June 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6180522
2 May 2017 COI Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6132457
13 September 2016 Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5999507
19 May 2016 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5882303
21 March 2016 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5843771
19 January 2016 Plan Review (Other than "T")
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5812277
28 June 2014 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4906916
28 June 2014 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4922289
10 June 2014 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4915017
13 June 2012 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4343082
9 May 2012 Deficiency Check · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4306586
20 September 2011 Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4149691
25 September 2008 Annual Inspection
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3337093
12 October 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3078638
19 September 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3062820
30 October 2006 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2810525
2 October 2006 Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2792126
23 September 2005 Re-Inspection
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2500564
17 May 2005 MTSA Verification
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2363023
4 October 2004 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2213168
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1977859
8 September 2003 Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1900513
22 August 2002 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1665269
15 April 2002 Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1604696
2 October 2001 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1467340
2 February 2001 Plan Review "T" Boat
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1059514
23 September 2000 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1408602
25 August 1999 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1402936
5 August 1999 Excursion Permit
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1114726
31 July 1999 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 51377
29 July 1999 Excursion Permit
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1107704
30 September 1998 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1364875
19 September 1998 Excursion Permit
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 799530
27 August 1998 Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 797622
14 October 1997 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 80291
10 September 1997 Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1430454
13 May 1997 Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1097061
16 October 1996 Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 843773
4 September 1996 COI Inspection · Drydock Extension
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1254814
15 September 1995 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1190656
19 April 1995 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 136575
15 September 1994 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1175642
3 November 1993 Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1151897
15 September 1993 COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 835449
13 April 1993 Administrative
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 835072
30 September 1992 Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 950992
17 September 1992 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 945724
5 May 1992 Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1260324
17 September 1991 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 935445
5 April 1991 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1222415
5 April 1990 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 919300
17 April 1989 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1042075
7 April 1989 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1031412
1 November 1988 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 891097
6 April 1988 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 892196
20 May 1987 Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1333444
12 May 1987 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1331969
25 March 1987 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1017294
6 August 1986 Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1305864
4 April 1986 COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1306988
3 April 1985 Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1292024

Deficiency record · 46

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 June 2025 Resolved
MDE exhaust temp repair requires permanent repairs.
Action required: 705 - Other - as specified
Due 31 October 2025
Resolved 14 May 2026
Resolution: inspected repairs, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2025 Resolved
MDE exhaust cracked at main deck. Temp repair plan submitted, temp repair plan approved.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2025
Resolved 30 June 2025
Resolution: Temp repairs approved. Permanent repairs to be effected after Labor Day 2025.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 March 2024 Resolved
Complete permanent repairs to holed bottom plate port side of engineroom 1 foot inboard the integral fuel tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2024
Resolved 18 April 2024
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023 Resolved
Remove old power strip from wheelhouse. Replace with new and marine type if needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 22 May 2023
Resolution: removed & replaced.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 June 2017 Resolved
Effect permanent repairs to leaking stbd fuel tank. All repairs shall be made to the satisfaction of the attending MI and after approval of repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 27 June 2017
Resolution: wasted piece cropped and renewed.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 May 2017 Resolved
Provide senior deckhand letter listing all qualified senior deck hands.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 16 May 2017
Resolution: Company emailed copy of letter complying with requirement.
Personnel › Training › Safety Orientation
Issued 11 May 2017 Resolved
Provide Haz Mat training to all crew.
Action required: 705 - Other - as specified
Due 11 June 2017
Resolved 9 June 2017
Resolution: Management provided proof of hazmat training done on 6/9/2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 May 2016 Resolved
One fixed steating fixture in upper deck passenger accomodation was loose and unsafe, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 19 May 2016
Resolved 19 May 2016
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 19 May 2016 Resolved
Policy information and assistance hotline not displayed, corrected during inspection.
Condition: Improper/Lack of Maintenance
Due 19 May 2016
Resolved 19 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 June 2014 Resolved
Hard-wire sewage pump on main deck in manner suitable for wet location.
Condition: Improper Installation
Due 10 July 2014
Resolved 8 July 2014
Resolution: per digital images and phoncon.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 June 2014 Resolved
Make all electrical outlets on main deck suitable for wet locations.
Condition: Improper Installation
Due 10 July 2014
Resolved 8 July 2014
Resolution: per digital images and phoncon.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 10 June 2014 Resolved
Provide means of emergency disconnection on emergency generator cranking battery.
Condition: Improper Installation
Due 10 July 2014
Resolved 8 July 2014
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 10 June 2014 Resolved
Provide overcurrent protection for small gauge wiring at emergency generator cranking battery.
Condition: Improper Installation
Due 10 July 2014
Resolved 8 July 2014
Resolution: per digital images and phoncon.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 10 June 2014 Resolved
Provide overcurrent protection for control and instrument feed wiring at connection to both main engine cranking motors.
Condition: Improper Installation
Due 10 July 2014
Resolved 8 July 2014
Resolution: per digital images and phoncon.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 10 June 2014 Resolved
Provide additional thermal insulation on both main engine exhaust systems to cover exposed sections.
Condition: Improper/Lack of Maintenance
Due 10 July 2014
Resolved 8 July 2014
Resolution: per digital images and phoncon.
Communications › Radio Communications › EPIRB
Issued 10 June 2014 Resolved
Provide valid hydrostatic release unit for EPIRB.
Condition: Improper/Lack of Maintenance
Due 10 July 2014
Resolved 8 July 2014
Resolution: per digital images and phoncon.
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 May 2012 Resolved
Tank level test petcocks on potable water tank pose high risk of contaminating potable water supply, to be removed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 4 June 2012
Resolution: cleared per email & photos from owner
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2012 Resolved
Provide permanent lug type connections at terminals on SSG starting batteries.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2012
Resolved 4 June 2012
Resolution: cleared per owner email/photos
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 9 May 2012 Resolved
Uninsulated exhaust line in proximity of diesel fuel tank for on-deck generator poses risk of fire, corrected during inspection.
Condition: Improper Installation
Due 17 June 2012
Resolved 17 May 2012
Resolution: corrected during inspection.
Engineering › Bilge Water Management System › Strainer
Issued 22 September 2011 Resolved
Remove all existing bilge suction strainers & install suitable bilge suction strainers having an open area not less than 3 times the area of the bilge pipe as required by (old T-L) 46 CFR 182.25-5(b) with the exception of the bilge suction strainer in the compartment forward of the collision bulkhead as allowed by (old T-L) 46 CFR 182.25-5(a)(1).
Due 22 October 2011
Resolved 17 October 2011
Resolution: Received photos of suitable bilge suction strainers in all required compartments.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 30 October 2006 Resolved
Permanently seal the open hole in the sewage collection/settling tank to prevent the possibility of sewage spilling or overflowing onto the vehicle deck. 33 CFR 159.95 (a) (1).
Condition: Unknown
Due 30 December 2006
Resolved 4 September 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 2 October 2006 Resolved
Label the three Electrical Circuit Breakers Boxes which are not identified IAW 46CFR 120.220(d). Boxes/Circuit Breakers mounted on the aft port side engine room bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 December 2006
Resolved 4 September 2007
Fire Fighting › Nozzles › Type
Issued 2 October 2006 Resolved
Outfit all Fire Fighting hose with an approved nozzle IAW 46CFR 118.320(c) and IAW 46CFR 162.027 (Combination Solid Stream & Water Spray Fire hose Nozzle).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 December 2006
Resolved 4 September 2007
Fire Fighting › Fire Pumps › Arrangement
Issued 2 October 2006 Resolved
Provide plans for review/approval, for the installation of a remote fire pump (PTO) starting switch/actuator to meet the requirements of 46 CFR 76.23-15. The current arrangement requires the watch stander to pass through the space on fire to actuate the sprinkler system. 46 CFR 181.25-1 & 46 CFR 181.25-5 (old T-L).
Condition: Design Flaw
Due 5 December 2006
Resolved 4 September 2007
Lifesaving › Rescue Boat › Carriage Requirement
Issued 2 October 2006 Resolved
Provide a Coast Guard approved Rescue boat and davit system for the vessel. Or, to meet the intent of 46 CFR 117.210 (a) (2) - install bridge wing engine controls stations on the port and stbd sides of the navigation bridge. Another alternative would be an installed camera system with a monitor on the navigation bridge. 46 CFR 117.15 & 46 CFR 117.210.
Condition: Unknown
Due 5 December 2006
Resolved 4 September 2007
Engineering › Fuel Oil Service System › Pump
Issued 2 October 2006 Resolved
Replace the current automotive type fuel pump on the diesel generator with an approved marine type fuel pump. 46 CFR 176.25-1 also see 46 CFR 58.10-5 (a), ABS Steel Vessels 4/2/1/1/1.1 & ABYC H-33 Diesel fuel systems. Fuel pumps cannot leak into the bilge - a mechanical fuel pump has to be a double diaphragm pump or have some other means to keep the fuel from leaking into the bilge.
Condition: Placed in Improper Service
Due 5 December 2006
Resolved 1 December 2006
Resolution: Cleared after same type fuel pump was found on DNV Class approved series 4045 John Deere engine.
Stability › Intact Righting Energy › General
Issued 2 October 2006 Resolved
Provide procedure for taking mid-body drafts as required by the vessels stability letter - after loading the vessel but before departing the dock as required by 46 CFR 122.315. The vessel’s stability letter states the minimum freeboard at the mid-body is 41" and the Master was not aware of this requirement - nor is the vessel outfitted to check this requirement.
Condition: Unknown
Due 5 December 2006
Resolved 30 November 2006
Resolution: Received fax copy of memo to vessel Captains - regarding the minimum freeboard at the mid-body. See scaned memo in MISLE Documents for details.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 August 2002 Resolved
REPLACE BROKEN LIGHT FIXTURE GLOBE ON MAIN DECK OVERHEAD STBD SIDE.
Condition: Unknown
Due 22 September 2002
Resolved 22 August 2002
Resolution: CORRECTED DURING INSPECTION.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 22 August 2002 Resolved
SECURE PORT MAIN ENGINE STARTER SELINOID ELECTRICAL WIRES WITH TAPE OR TIE WRAPS. LEGACY COMPONENT DESC: STARTER SOLENOID
Condition: Unknown
Due 22 September 2002
Resolved 22 August 2002
Resolution: CORRECTED DURING INSPECTION.
Construction/Loadline › Hull
Issued 15 April 2002 Resolved
Crop and renew hull plating approximately 3' X 4' in way of the forward two frames, port side engineroom, underneath the potable water tank. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2002
Resolution: Satisfactory hose test of repair.
Lifesaving
Issued 2 October 2001 Resolved
ONE OF 3 RING LIFE BUOYS EXCESSIVELY DETERIORATED IWO NYLON BANDS FOR GRABLINES, REPLACED DURING INSPECTION.
Condition: Unknown
Due 23 October 2001
Resolved 23 October 2001
Lifesaving
Issued 23 September 2000 Resolved
Stow buoyant apparatus pendants as per 46 CFR 160.101.4 prior to the compliance date.
Condition: Unknown
Due 23 September 2000
Resolved 23 September 2000
Navigation
Issued 25 August 1999 Resolved
FOUND ALL CLAMP BOLTS MODERATELY LOOSE ON BOTH RUDDER STOCKS, TIGHTENED DURING INSPECTION.
Condition: Unknown
Due 26 August 1999
Resolved 26 August 1999
Electrical
Issued 25 August 1999 Resolved
REROUTE OR SHORTEN PORT MAIN ENGINE STARTING CABLES BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Lifesaving
Issued 25 August 1999 Resolved
RENEW LANYARDS FOR FLOAT LIGHTS ON 2 AFT BUOYANT APPARATUS BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Lifesaving
Issued 25 August 1999 Resolved
REPLACE TRANSOM BOARD AND WELD FRACTURED ALUMINUM GUNWALE IN WAY OF AFT PORT HOISTING PADEYE, BEFORE THE COMPLIANCE DATE.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Lifesaving
Issued 4 September 1996 Resolved
Install retroreflective tape on Ring Lifebuoys and rescue boat.
Condition: Unknown
Due 4 October 1996
Resolved 15 October 1996
Lifesaving
Issued 15 September 1993 Resolved
REPLACE THREE WORN WATER LIGHT LIGHT LINES ATTACHED TO BUOYANT APPARATUS.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Navigation
Issued 15 September 1993 Resolved
PROVIDE PROPER BULBS FOR NAVIGATION LIGHTS TO SATISFY RULE 22 OF INLAND NAVIGATION RULES, AND 33 CFR 84.15 FOR MINIMUM LUMINOUS INTENSITY.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Fire Fighting
Issued 17 September 1992 Resolved
HYDROSTATICALLY TEST ALL PORTABLE CO2 BOTTLES.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Lifesaving
Issued 17 September 1992 Resolved
PROVIDE 21 ADULT PFD'S. PASSENGER CAPACITY REDUCED TO 185 UNTIL PFD'S _x001C_ ONBOARD.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Lifesaving
Issued 17 September 1992 Resolved
PROPERLY STENCIL PFD STORAGE LOCKERS TO ACCURATELY REFLECT CONTENTS.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Navigation
Issued 7 April 1989 Resolved
RENEW CABLE ON STEERING GEAR
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Electrical
Issued 7 April 1989 Resolved
REPAIR OR RENEW AMP METER ON GENERATOR.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Fire Fighting
Issued 7 April 1989 Resolved
REPLACE (2) 50' 1 1/2" FIREHOSES
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989
Lifesaving
Issued 7 April 1989 Resolved
PROVIDE 3 ADDITIONAL ADULT PFD'S. TOTAL NUMBER OF PERSONS ALLOWED IS HEREBY REDUCED TO 203 PENDING COMPLETION OF THIS REQUIREMENT.
Condition: Unknown
Due 7 April 1989
Resolved 7 April 1989

Casualty record · 5

13 June 2012Routine · role: Involved in a Marine Casualty · activity 4343082
19 August 2012Routine · role: Involved in a Marine Casualty · activity 4415115
28 June 2014Routine · role: Involved in a Marine Casualty · activity 4906916
6 June 2022Routine · role: Involved in a Marine Casualty · activity 7470069
18 March 2024Routine · role: Involved in a Marine Casualty · activity 7882589
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.