WAN HE is a 2002 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in October 2024, along with 11 deficiencies and 1 operational control.

Records from 2016 to 2024. Most recent: inspection, 2 October 2024.

Built
2002
Last inspected
2 October 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9248461
512732
Flag
MARSHALL ISLANDS
Maury page id
psix-512732

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it15148 - Convention (Subpart B), Gross Ton
7022 - Convention (Subpart B), Net Ton
24405 - Dead Weight, Metric Ton
31561 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 13

2 October 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8010391
25 September 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8009278
6 June 2019 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6705608
10 April 2019 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6656072
17 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6416793
7 May 2018 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6403377
3 January 2018 MARPOL Annex II Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6331769
13 October 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6287100
22 April 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6130255
10 April 2017 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6121074
5 February 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6082952
5 October 2016 ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6016491
29 February 2016 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5821328

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 2 October 2024 Resolved
The inert gas system shall be desibed and operated as to render and maintain the atmosphere of the Cargo tanks at all times. The Inert gas generator was non operational vessel is prohibited from carrying cargoes required to be inerted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2024
Resolved 5 December 2024
Resolution: Vessel submitted Class Report attesting to the repairs of the inert gas system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2024 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of a electrical fault, in such areas, special precausions against such risk shall be taken. Exposed wiring identified at each high level overfill detector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 October 2024
Resolved 2 October 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 2 October 2024 Resolved
The company shall establish and maintain procedures for identifying any training and ensure training is provided. Crew was not proficient with the operation and testing of the IGS and gas detection system. RO Audit required to ensure compliance with SMS certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 October 2024
Resolved 5 December 2024
Resolution: Vessel submitted a Class Report attesting to an audit/training had been completed in regards to the IGS and gas detection system.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 10 April 2019 Resolved
06105-ATMOSPHERE TESTING INSTRUMENTS-WHERE THE ATMOSHERE IN DOUBLE HULL SPACES CANNOT BE RELIABLY MEASURED USING FLEXIBLE GAS HOSES SUCH SPACES SHALL BE FITTED WITH PERMANENT GAS SAMPLING LINES. PSCO NOTED THE LOW FLOW SENSOR WAS INOPERABLE, THE CREW REPLACED THE SENSOR. PSCO WITNESSED PROPER OPERATION OF THE GAS DETECTION SYSTEM AND ASSOCIATED ALARMS. 74SOLAS(01)II-2/4.4.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 April 2019
Resolved 10 April 2019
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 10 April 2019 Resolved
06107-CARGO OPERATION-EACH INERT GAS SYSTEM MUST BE DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF SOLAS II-2/62. PSCO NOTED THE INSTALLED DOUBLE BLOCK AND BLEED SEAL SYSTEM WAS INOPERABLE. CREW SERVICED VALVES AND PSCO WITNESSED PROPER OPERATION OF DOUBLE BLOCK AND BLEED SEAL. SOLAS 74(01) II-2/62. 46CFR32.53-10(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 April 2019
Resolved 10 April 2019
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 10 April 2019 Resolved
06107-CARGO OPERATION-THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO NOTED CARGO TANK #11 PORT RADAR SOUNDING SHOWED CONTENTS IN THE TANK. THE TANK IS ACTUALLY COMPLETELY EMPTY AND CLEAN. 74SOLAS(01)I/11
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 10 April 2019
Resolved 6 June 2019
Resolution: Reviewed corrective action report attesting to the proper operation of radar gauging system.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 7 May 2018 Resolved
1840 - The condition of the ship and its equipment shall be made to conform with the provisions of the present regulations to ensure the ship in all respects remains fit to proceed to sea. PSCO observed the pressure indicator for the 12S centrifugal pump was inoperational and displayed that the pump was maintaining pressure even after the pump and power packs were shut down. 74 SOLAS(a) 2014 cons. I/11; 16a.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 17 May 2018
Resolution: SEC HOU-GAL PSC received a tech report from FRAMO satisfying the requirement
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 May 2018 Resolved
0999 - Where cables are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault, in such areas special precautions against such risks shall be taken. PSCO observed the pressure sensors for the #2-4 vapor recovery line had exposed wiring and the boxes housing the sensors had inadequate securing devices rendering them not airtight/intrinsically safe. 74 SOLAS(a) 2001 cons. II-1/45.5.4; 10c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 May 2018
Resolution: PSCO witnessed vessel electrician reinstall the pressure sensors and remove the hazard of exposed wires by encasing in electrician's putty, the retrofit was verified against the pressure sensor install in vapor recovery line #1.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 3 January 2018 Resolved
The master or person in charge of an oceangoing ship shall ensure that NLS residue is retained onboard. Annex II overboard discharge valve not completely closed, allowing residual annex II discharge. 33CFR151.43(a)(1)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 January 2018
Resolved 3 January 2018
Resolution: Valve was properly secured and the piping was blanked.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 10 April 2017 Resolved
The inert gas system referred to in regulation 60 shall be designed, constructed and tested to the satisfaction of the administration. Water seal piped to scrubber in E/R was leaking water, additionally, engineering crew could not display proper operation of IGG. Vessel is carrying IBC cargoes that do not require the use of the IGG. Demonstrate to class and Coast Guard proper operation of IGG.
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 22 April 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 10 April 2017 Resolved
Acceptable types of water seals include the wet and semi wet type. Other types of seals may be accepted on a case by case basis if approval is given by MSC. Vessel does not have a wet or semi wet deck water seal, they have a double block and bleed arrangement dry type seal with no approval from MSC. 46 CFR 32.53-10(b)(1)
Action required: 705 - Other - as specified
Due 24 April 2017
Resolved 22 April 2017
Resolution: PSC NOLA received an alternative acceptance letter from MSC satisfying the requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.