Records from 1984 to 2018. Most recent: inspection, 21 February 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Navigation › Piloting/Steering › Marine Charts
Issued 25 October 2010
Resolved
Vessel did not have an up to date NOAA chart available at the time of the inspection.
Condition: Improper/Lack of Maintenance
Due 22 November 2010
Resolved 19 September 2011
Resolution: Found satisfactory following COI inspection.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 October 2010
Resolved
Vessel's COD was not up to date at the time of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2011
Resolution: Found to be satisfactory at the time of COI inspection.
Construction/Loadline › Structures › Superstructure
Issued 25 October 2010
Resolved
Upon arrival to the vessel the attending MI observed a new canopy in place over the aft deck of the vessel that was not on the vessel during the HULL/ ISE examination which was completed . Discussed the addition of the structure with the vessel representative and was imformed that the vessel had a canopy on it when he purchased the vessel.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2011
Resolution: Found to be satisfactory at the time of COI inspection, canopy removed.
Documentation › Certificates/Documents › Stability Letter
Issued 25 October 2010
Resolved
A stability test and a Certificate of Inspection exam will be required prior to carrying passengers for hire due to the owner extending the sail area of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2011
Resolved 19 September 2011
Resolution: Found to be satisfactory at the time of COI inspection, canopy removed.
Construction/Loadline › Hull › Hull Plating
Issued 24 March 2008
Resolved
Weld pin hole in transom below deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 March 2008
Resolved
Repair hole in stern.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 August 2006
Resolved
Provide exhaust insulation for portside exhaust. 46CFR182
Action required: 705 - Other - as specified
Due 18 September 2006
Resolved 30 August 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 18 August 2006
Resolved
Provide light covers & lights where hard fixed in engine room. 46CFR183.310
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2006
Stability › Unintentional Flooding › General
Issued 18 August 2006
Resolved
Label high level bilge alarms at bridge console. 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2006
Navigation › Piloting/Steering › Marine Charts
Issued 18 August 2006
Resolved
Obtain large scale chart for area transitted. 46CFR184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 August 2006
Resolved 30 August 2006
Lifesaving › Lifefloat › Float-free Link
Issued 18 August 2006
Resolved
Attach sea painter for life float to weak link. 46CFR180.130
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 August 2006
Resolved
Mount the B-II fire extinguisher in the engine room. 46CFR181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 18 August 2006
Resolved
Replace all retroflective tape on life ring buoy. 46CFR185.604
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2006
Electrical › Electric Supply System (service) › Battery Conductor
Issued 18 August 2006
Resolved
Clean and/or replace battery cables in the vicinity of battery boxes. Noted insulation to be broken, covered in oil and inproperly spliced. 46CFR183
Action required: 705 - Other - as specified
Due 18 September 2006
Resolved 30 August 2006
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 January 2006
Resolved
Replace missing dog on the water tight hatch leading into the engine room from the main deck.
Due 24 February 2006
Resolved 16 February 2006
Resolution: Replaced missing dog on the water tight hatch leading into the engine room
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 January 2006
Resolved
Provide and install a valve and check in way of the A/C cooling water overboard discharge as close to the hull of the vessel as possible.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 16 February 2006
Resolution: Installed a valve and check valve in way of the A/C cooling water overboard discharge.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 January 2006
Resolved
Prove water tight integrity of the water tight bulkhead door leading into the generator room.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 16 February 2006
Resolution: Proved watertight integerity of watertight bulkhead.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 January 2006
Resolved
Remove the plastic through hull fitting in the engine room on the starboard side aft.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 16 February 2006
Resolution: Removed the plastic through hull fitting in the engine room.
Construction/Loadline › Hull › Hull Plating
Issued 17 January 2006
Resolved
Make weld repairs to the hole in the bottom plate in the forward peak in way of the keel and bottom plate.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 16 February 2006
Resolution: Repaired holed area in bottom plate.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 June 2005
Resolved
Post Certifcate of Inspection on board vessel as required by 46 CFR 176.107.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 11 August 2005
Resolution: COI posted
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 June 2005
Resolved
Provide up to date tide and current tables as required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 11 August 2005
Resolution: Updated pubs onboard
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 June 2005
Resolved
Provide up to date US Coast Pilot as required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 11 August 2005
Resolution: Updated Coast Pilot onboard
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 June 2005
Resolved
Provide up to date Coast Guard Light List as required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 11 August 2005
Resolution: Updated Light List onboard
Navigation › Collision/Grounding Avoidance › Radar
Issued 21 June 2005
Resolved
Provide for proper operation on the radar as per 46 CFR 184.404.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 11 August 2005
Resolution: Radar test sat
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 21 June 2005
Resolved
Renew/repair single side band radio IAW 46 CFR 184.502.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 11 August 2005
Resolution: SSB operational
Stability › Watertight Integrity › General
Issued 21 June 2005
Resolved
Renew port dog on emergency escape hatch and prove tightness of hatch as per 46 CFR 177.500.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 11 August 2005
Resolution: Dog renewed
Stability › Watertight Integrity › General
Issued 21 June 2005
Resolved
Renew broken dogs on watertight door to generator room and prove tightness of door as per 46 CFR 179.330.
Action required: 705 - Other - as specified
Due 21 July 2005
Resolved 11 August 2005
Resolution: Dogs renewed
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 September 2004
Resolved
Replace 6 PFD's that were found in NOT IAW 46 CFR 180.71 Passenger count reduced to 22 untill PFD's are replaced
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2004
Resolved 22 September 2004
Resolution: Operator purchased additional PFDs.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 1 September 2004
Resolved
Provide proof of enrollment of drug testing program IAW 46 CFR part 16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2004
Resolved 22 September 2004
Resolution: Provided proof of drug testing program enrollment.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 July 2004
Resolved
Post Certificate of Inspection IAW 46CFR 176.107
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Owner had COI posted upon inspectors return to vessel
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 July 2004
Resolved
Provide CG light list IAW 46 CFR 184.420
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Light list was purchased by owner.
Navigation › Piloting/Steering › US Coast Pilot
Issued 28 July 2004
Resolved
Provide US Coast Pilot IAW 46 CFR 184.420
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Owner purchased new Coast Pilot
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 July 2004
Resolved
Provide current tide/current tables IAW 46 CFR 184.4220
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Owner purchased new tables.
Navigation › Piloting/Steering › Magnetic Compass
Issued 28 July 2004
Resolved
Repair magnetic compass light IAW 46 CFR
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Attended vessel and verified operation of magnetic compass.
Communications › Radio Communications › EPIRB
Issued 28 July 2004
Resolved
Provide NOAA registration for EPIRB IAW 46 CFR 180.64
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Registrations was presented and verified by inspector.
Communications › Radio Communications › EPIRB
Issued 28 July 2004
Resolved
Renew hydrostatic release for EPIRB IAW 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Hydrostatic release was renewed by owner
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 28 July 2004
Resolved
Missing one PFD IAW COI and 46 CFR 180.71
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Vessel provided additional PFD
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 July 2004
Resolved
Renew lifelines and grabline on lifebuoy IAW 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Owner purchased new line.
Lifesaving › Lifefloat › Markings
Issued 28 July 2004
Resolved
Renew markings on lifefloats IAW 46 CFR 1853604 (a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Markings were renewed on lifefloats.
Lifesaving › Lifefloat › Painter
Issued 28 July 2004
Resolved
Renew grablines, painter and net IAW 46 CFR 160.010-8
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 14 September 2004
Resolution: All lines reaplaced on lifefloat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 July 2004
Resolved
Provide waterlight for lifefloat IAW 46 CFR 180.175
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Owner purchased waterlight for life float
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 July 2004
Resolved
Renew expired eyewash and aspirin in First Aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Owner pruchased new eyewash and aspirin.
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 July 2004
Resolved
Repair broken valve on remote emergency fuel shutoffs IAW 46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Valve was repaired and SAT operation was witnessed by inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 28 July 2004
Resolved
Service all fire extinguishers IAW 46 CFR 176.180
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Fire extinguishers were serviced. Inspector verified inspection dates.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 July 2004
Resolved
Provide emergency lighting IAW 46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Emergnecy lighting was verified on-scene by inspector.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 28 July 2004
Resolved
Provide vessel's name on 2 PFDs
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Owner stenciled name on PFDs.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 July 2004
Resolved
Repair forward running light IAW 72 COLGREGS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: Light was operable as witnessed by inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 28 July 2004
Resolved
Provide charts for operating area IAW 46 CFR 184.420
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 September 2004
Resolved 1 September 2004
Resolution: New charts were purchased by owner.
Documentation
Issued 30 October 2002
Resolved
Provide for Coast Guard review, current FCC Safety Certificate. LEGACY COMPONENT DESC: FCC Safety Certificate
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 4 November 2002
Resolution: A current FCC Safety Certificate was provided.
Documentation › Certificates/Documents
Issued 30 October 2002
Resolved
Provide current FCC Marine Operator [name withheld] DESC: FCC Marine Radio Operators Permit
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 4 November 2002
Resolution: Vessel rep provided current FCC Marine Operator Permit
Accommodation/Occupational Safety › Occupational Safety
Issued 30 October 2002
Resolved
Remove and properly stow debris and loose gear in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 4 November 2002
Resolution: Loose gear was stowed. Trash was removed from vessel and disposed of properly.
Electrical › Electrical Distribution System (service)
Issued 30 October 2002
Resolved
Install covers to all engine room junction boxes to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 4 November 2002
Resolution: Covers were placed on junction boxes and were properly secured.
Electrical › Electric Generation Source (service)
Issued 30 October 2002
Resolved
Make repairs or renewals as necessary to ensure all batteries are stowed in box with appropriate fittings for cable runs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 4 November 2002
Resolution: Proper stuffing tubes were installed in battery box.
Engineering › Lubricating Oil Storage/Transfer System
Issued 30 October 2002
Resolved
Provide suitable guards to sight glass on lube oil day tank to the staisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 4 November 2002
Resolution: Proper guards (all thread) were installed.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 October 2002
Resolved
Mark emergency escape hatch as required by 46 CFR 185.606, "Emergency Exit, Keep Clear". LEGACY COMPONENT DESC: Emergency Escape
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 4 November 2002
Resolution: Hatches were stenciled in block, 3in letters
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 30 October 2002
Resolved
All portable fire extinguishers shalll be serviced and marked in accordance with 46 CFR 176.810. LEGACY COMPONENT DESC: Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 4 November 2002
Resolution: Fire extinguishers were serviced. Certificates and labeling were provided.
Navigation › Piloting/Steering
Issued 30 October 2002
Resolved
Provide current navigation publications as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Navigation Publications
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 4 November 2002
Resolution: Current navigation publications were purchased, stenciled and placed on board vessel.
Documentation
Issued 20 July 2001
Resolved
PROVIDE STABILITY LETTER NO LATER THAN 20AUG01
Condition: Unknown
Due 20 August 2001
Resolved 26 September 2001
Electrical
Issued 20 July 2001
Resolved
PROVIDE FASTENERS FOR WIRING IN ENGINE ROOM AS REQUIRED BY 46 CFR 183.340P
Condition: Unknown
Due 20 August 2001
Resolved 26 September 2001
Accommodation/Occupational Safety
Issued 20 July 2001
Resolved
PROVIDE MARKINGS ON EMERGENCY ESCAPE HATCH AS REQUIRED BY 46 CFR 185.606
Condition: Unknown
Due 20 August 2001
Resolved 26 September 2001
Lifesaving
Issued 20 July 2001
Resolved
PROVIDE CABLE FOR FORWARD HATCH, ENSURE HATCH IS CLOSED WHEN UNDERWAY AS PER 46 CFR 179.360
Condition: Unknown
Due 20 August 2001
Resolved 26 September 2001