VOYAGER

VOYAGER is a 1975 passenger vessel (inspected). The Coast Guard has recorded 85 inspections since 1985, most recently in March 2026, along with 156 deficiencies and 1 casualty investigation in 2020.

Records from 1985 to 2026. Most recent: inspection, 17 March 2026.

Built
1975
Last inspected
17 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH8901
Flag
UNITED STATES
367034570
Maury page id
psix-51276

Inspections, by type

…with no type recorded6
Years with a record 37 calendar years (1985–2026)
The 85 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)90.0 ft × 23.0 ft × 7.9 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPOINT PLEASANT BEACH, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 16 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH8901MMSI 367034570 · active · compulsorily equipped · granted 15 April 2025, expires 21 March 2035
WDC5026MMSI 367034570 · cancelled · compulsorily equipped · granted 19 April 2005, cancelled 18 March 2015 · licensed under a name not among this hull’s recorded names (not shown)
WTU9609MMSI not assigned · expired · compulsorily equipped · granted 8 August 1996, cancelled 9 December 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 85

17 March 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8331602
20 May 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8139642
16 April 2025 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8112718
21 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8097192
4 March 2025 Internal Structural Exam · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8087840
23 April 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7899947
31 January 2024 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7864375
19 September 2023 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7794047
15 August 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7769236
4 May 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7688990
27 March 2023 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7657437
28 February 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7643119
29 May 2022 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7463513
3 May 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7443307
21 October 2021 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7336909
30 August 2021 Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7298111
14 July 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7255949
28 April 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7185049
16 March 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7156699
11 December 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7115163
15 April 2020 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6939517
10 April 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6937931
7 October 2019 Plan Review "T" Boat · Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6829488
22 April 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6667891
22 February 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6630761
6 September 2018 Inclining Experiment · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6534309
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6505569
17 April 2018 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6389103
25 April 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6131732
14 February 2017 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6102000
23 March 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5838678
18 February 2016 Drydock Exam · Deficiency Check · Plan Review "T" Boat · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5817632
15 August 2014 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4958412
13 May 2014 Deficiency Check · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4857282
7 May 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4853141
14 April 2009 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3449515
10 March 2008 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3161566
12 March 2007 COI Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2886604
29 March 2006 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2608866
23 March 2005 Annual Inspection · Internal Structural Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2316822
11 May 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2077516
29 March 2004 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2033846
28 May 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1830884
9 May 2002 Administrative Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1614727
24 April 2002 In-Service Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1608659
3 April 2002 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1695554
20 March 2002 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1598030
15 March 2001 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1060720
5 May 2000 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1401227
15 March 2000 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1048362
17 March 1999 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 808302
16 April 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1128924
28 March 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364573
10 April 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1099435
7 June 1996 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1188113
21 March 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 884829
23 March 1995 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1178550
16 May 1994 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1168457
22 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 643255
22 March 1994 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1442118
3 June 1993 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1373872
15 April 1993 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1438052
15 May 1992 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1271015
16 April 1992 COI Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 955302
13 December 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1257613
15 May 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1197684
11 April 1991 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1237938
6 December 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1221028
17 May 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1211749
5 April 1990 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 913998
28 November 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1235453
12 April 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1045003
12 April 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1348829
30 March 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1043599
31 March 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 990345
2 September 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1004582
16 April 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1011905
8 April 1987 Examination of Repairs
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1027562
26 March 1987 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1309335
27 January 1987 Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1005346
27 June 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 984990
5 June 1986 Credit Drydock · Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 999749
20 March 1986 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1309236
5 June 1985 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1292107
21 March 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 979707

Deficiency record · 156

09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 March 2026 Resolved
Vessels described by 46 CFR 175.110(d) must comply with the regulations in § 177.500. Vessel's two means of escape from overnight accommodation space lead to the same compartment. Passengers cannot utilize overnight accommodations. 46 CFR 177.115(c)
Action required: 705 - Other - as specified
Due 26 April 2026
Resolved 22 July 2026
Resolution: Vessel added partition to reduce square footage of space, allowing them to only need one means of escape. Vessels existing stairs are satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 March 2026 Resolved
A ladder leading to a deck scuttle may not be used as a means of escape except:(1) On a vessel of not more than 19.8 meters (65 feet) in length, a vertical ladder and a deck scuttle may be used as not more than one of the means of escape from passenger accommodation space. Submit proposal for modifications to the satisfaction of MI. 46 CFR 177.500(j)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 22 July 2026
Resolution: Vessel added partition to reduce square footage of space, allowing them to only need one means of escape. Vessels existing stairs are satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2025 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are readily accessible and visible to the crew and passengers. Vessel has life jacket placard for only one of the three types of life jackets on board. 46 CFR 185.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 13 April 2025
Resolution: O/O replaced old lifejackets with same in kind on placards.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 March 2025 Resolved
All fittings on fire hose shall be of brass, copper, or other suitable corrosion resistant material. Nozzles on port and starboard fire hose were severely corroded. 46 CFR 181.15-10(f) Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 21 March 2025
Resolution: Fittings provided.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 April 2024 Resolved
The scope of the annual inspection is the same as the inspection for certification... At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Due to main engine low oil pressure vessel unable to get u/w.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2024
Resolved 25 April 2024
Resolution: MDE was repaired. Got vsl u/w. Due to sea conditions drill was done dockside. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 April 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the ....operator shall be prepared to conduct tests and have the vessel ready for inspections of ...Operation of the main propulsion machinery both ahead and astern. One MDE was inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2024
Resolved 25 April 2024
Resolution: MDE Lube Oil relief valve was renewed & tested sat. Vessel was tested u/w sat.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 April 2024 Resolved
Stability information (stability details indicated a stability letter), is required on...A vessel which,...complies with requirements in subchapter S of this chapter. Vessel exceeded the limits of Stab Ltr onboard
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 25 April 2024
Resolution: The stability letter was reissued due to errors. The revised stability letter was located and posted while the exististing, incorrect, letter was discarded.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 23 April 2024 Resolved
...a test communication on a required frequency in the 1605 to 27500 kHz band...Operator was unable to demonstrate proper function of the SSB
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 25 April 2024
Resolution: SSB was tested sat by contacting a vessel in the NY Area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 April 2024 Resolved
One or more metallic shutoff valves must be installed adjacent to the fitting...two metallic shutoff valves are installed, one on either side of the bulkhead,... Vessel had flexible hoses penetrating void 2/3 WT Blkhd.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 21 March 2025
Resolution: Shutoff valves installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2024 Resolved
...Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The Port Generator RW discharge hose had several bulges. The bilge suction hose was badly worn.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 November 2024
Resolution: The generator hose was renewed 25 Apr 2024. The bilge piping was repaired with a dresser coupling 7 Nov 2024. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2024 Resolved
Auxiliary boilers and heating boilers and their associated piping and fittings will be given separate consideration and must meet the applicable requirements of subchapter F...heating boilers must be tested or examined every three years. There were no records of boiler or furnace testing. Hoses were not CG approved fire rated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 7 November 2024
Resolution: Boilers were removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2024 Resolved
Electrical installations shall be to the satisfaction of the [name withheld] cord connections were used for fixed lighting and compressor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 7 November 2024
Resolution: Installations were hard wired 25 Apr 2024 & were installed in enclosures 7 Nov 2024.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 April 2024 Resolved
..a vessel for which an extension is granted under paragraph (1)(C) shall provide on the website of such owner or operator of the vessel, the vessel, and each ticket for a passenger a prominently displayed notice that the vessel is exempt from meeting the Coast Guard safety compliance standards concerning egress as described in such section.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 17 March 2026
Resolution: Verified owner had the required wording on their website
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 May 2023 Resolved
Vessel is restricted from carrying overnight passengers until watch alert system required by 46 CFR 184.410 (b) is approved, installed, and verified by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 1 December 2023
Resolved 19 September 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 February 2023 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel missed it's drydock that was due 28FEB23. Vessel must complete drydock examination prior to carrying passengers. 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2023
Resolution: Drydock inspection complete.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 May 2022 Resolved
MI observed a crack in the steering scuttle outer framing/ knife edge where the gasket would sit. 46CFR176.01-10(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 30 May 2022
Resolution: re-welded the crack. Orderd and has a new hatch on hand to replace at the dry dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 May 2022 Resolved
MI observed that on the Generator switchboard the ammeter and the frequency (hertz) meter were inop. Require vsl repair/replace equipment for proper operation. 46cfr183.10-5(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 30 May 2022
Resolution: both ammeter and frequency meters were replace and working.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 May 2022 Resolved
MI observed ground detection on the generator switchboard inop. Require repair/replace equipment for proper operation. 46cfr111.05-21
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 3 November 2022
Resolution: Received tech report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2022 Resolved
MI observed numerous black ground cables on the engine room batteries had cuts and crack on the insulation. Require cables be replaced with proper battery cables. 46cfr183.05-40(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 30 May 2022
Resolution: replace all cracked ground cables from batteries.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2021 Resolved
Identified misalignment of installed portable fire extinguishers with revised regulations and policy. Vessel has one legacy B-II CO2 fire extinguisher in ER, with remaining fire extinguishers NFPA-10/UL rated or dual rated w/USCG rating. In addition, when the COI was revised to list the new performance-based rating, the required arrangement was not updated. For the current operating arrangements, layout, and configuration, the VOYAGER should have (1) 10-B:C on the upper deck/ operating station, (2) 2-A w/ (1) in the main deck salon and (1) in the below deck berthing, and (2) 40-B:C located in the concession area outside of the Engine Room with (1) for responding to Engine Room fires and the other for fires in the Concession area from risk of fire from the furnace or appliances. Vessel must add two (2) 40-B:C extinguishers in the vicinity of the Concession area/access to the Engine Room and replace the 10-B:C in the Salon with a 2-A extinguisher. CITE: CG-CVC Policy Ltr 18-04, & 46 CFR §181.500(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 2 September 2021
Resolution: Vessel added extinguisher to accommodation/salon area.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2021 Resolved
Life Ring Buoy on upper deck by wheelhouse is in unserviceable condition. Vessel is required to have a USCG Approved Ring Buoy w/ Light in this location. Replace with new, approved Lighted Ring Life Buoy. CITE: 46 CFR §180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 2 September 2021
Resolution: Life buoy was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2021 Resolved
One older Kapok PFD unserviceable (Kapok cells leaking). Replace unserviceable PFD with new, USCG Approved PFD. CITE: 46 CFR §180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 14 May 2021
Resolution: Replaced prior to end of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Observed significant rusting and wastage of the end shell of the 15 gal combined air compressor/receiver in Compartment 2. Prove safe condition of or replace air receiver. CITE: 46 CFR §182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 3 May 2022
Resolution: Attended vsl, observed a new air receive mounted properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 April 2021 Resolved
Electronic propulsion control systems must be designed so that a loss of power to the control system does not result in increased shaft speed or propeller pitch, as per 184.620(c). A propulsion control system drawing should be submitted along with a ‘Test Protocol’ to verify this. The Test Protocol should consist of a limited Qualitative Failure Analysis (QFA) and Design Verification Test Procedure (DVTP), only including analysis of the loss of power to the control system. Please provide copies of the propulsion control system drawing with Test Protocol for review. CITE: CG-CVC_POL17-07, CG-CVC_POL17-07-RefB, & PRG.E2-23.2017.07.26
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 14 July 2021
Resolution: Uploaded VOYAGER QFA-DVTP Appvl, MSC ltr E2-2102172.pdf MSC Approval Ltr of installed electronic propulsion control system's QFA/DVTP to MISLE Documents.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 May 2020 Resolved
Prove operation of the fire pump and bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2020
Resolution: Observed sat test via facetime.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 May 2020 Resolved
Repair or replace engine room bilge visual alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 May 2020
Resolution: Replaced LED.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2020 Resolved
Label electrical breakers in the engine room with the circuits serviced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 May 2020
Resolution: Labeled breakers
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2020 Resolved
Provide a sign stating the upper deck is limited to 50 person in accordance with the stability letter. Remove sign that states 60 persons.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 May 2020
Resolution: Affixed new sign.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 April 2020 Resolved
Complete COI Renewal inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2020
Resolved 1 May 2020
Resolution: COI inspection completed #6939517
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2019 Resolved
Vessel has two fire hydrants and only one spanner. Provide additional spanner. 16C 46 CFR 181.310(d).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Vessel purchased spanner wrench.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
Vsl is broadcasting: No static draft information.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 6 November 2018
Resolution: AIS information updated.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 April 2018 Resolved
Place machinery guards around rotating machinery on the main propulsion engines.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 June 2018
Resolved 30 April 2018
Resolution: Guards were placed on the exposed belts.
Engineering › Fuel Oil Service System › Filter
Issued 17 April 2018 Resolved
PG02. Place plugs or caps on all fuel strainers in the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2018
Resolved 20 April 2018
Resolution: The crew placed caps on the Racor fuel filters. Photos are in MISLE.
Construction/Loadline › Penetrations › Valve Flange
Issued 14 February 2017 Resolved
Replace sea chest valve on generator.
Condition: Improper/Lack of Maintenance
Due 9 March 2017
Resolved 8 March 2017
Resolution: Recieved pictures of new valve. Attached in documents.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 August 2014 Resolved
Vessel is required to carry 12 child life jackets and 2 were found un-serviceable. Vessel must replace with approved type and is restricted to a total of 100 passengers
Due 30 August 2014
Resolved 20 November 2014
Resolution: New Life Jackets on board
Lifesaving › Lifefloat › Float Free
Issued 15 August 2014 Resolved
Vessels life floats are currently covered and could prevent launching, must remove during underway operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2014
Documentation › Logs/Records › Drug Test Records
Issued 15 August 2014 Resolved
Vessel currently have only 1 out of 5 deckhands that are in the vessels DAPI program, vessel may only operate with crew members currently enrolled in program and are compliant.
Due 30 August 2014
Resolved 1 December 2014
Resolution: Copy of test results provided by owner of vessel.
Construction/Loadline › Hull › Hull Plating
Issued 13 May 2014 Resolved
Plating underneath the portside hatch to the engine room needs to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2014
Resolved 13 May 2014
Resolution: Port Side was noted as having less than 25% of hull plating remaining. Repair proposal conducted by [name withheld], accepted by USCG. Plate was fitted and replaced.
Construction/Loadline › Hull › Hull Plating
Issued 7 May 2014 Resolved
Conduct Credit Drydock
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2014
Resolution: Credit drydock completed on 13MAY14 at Yanks Marine.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 May 2014 Resolved
Replace 2 life jackets vsl may only carry 112 passengers until life jackets are replaced.
Action required: 705 - Other - as specified
Due 31 March 2015
Resolved 31 March 2015
Resolution: Verified w/ previous marine inspector that def had been resolved. Issued CG-835 for reduction to 101 pax during COI conducted on this date.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 April 2009 Resolved
Install door and drip shield on galley electric distribution panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 23 June 2009
Resolution: Owner installed cover and drip shield on the electrical distribution panel in the galley.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 April 2009 Resolved
Install blank and drip shield on engine room electric distribution panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2009
Resolved 23 June 2009
Resolution: Owner installed blank and drip shield on engine room electric distribution panel.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 March 2007 Resolved
Provide up to date current tables.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 11 April 2007
Resolution: O/O stated up to date current table placed on board vessel.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 13 March 2007 Resolved
Repair Hydraulic Fluid leak in E/R stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 11 April 2007
Resolution: O/O stated hydraulic fluid leak stopped. Informed O/O MI would verify during next visit to area.
Engineering › Bilge Water Management System › Pump
Issued 29 March 2006 Resolved
Bilge pump in fwd. peak did not have proper suction.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 10 April 2006
Resolution: Attended vessel. Pinhole area has been welded and pipe sounded satisfactory.
Communications › Radio Communications › EPIRB
Issued 29 March 2006 Resolved
Hydrostatic Release Unit not marked with expiry date and no certificate was available to prove current validity. Vsl. restricted to within 3 mi. from shore until hydrostatic replaced and verified by attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2006
Resolved 29 March 2006
Resolution: Attended vessel and confirmed new installation of HRU on EPIRB. Exp. date MARCH 08.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 March 2005 Resolved
Repair starboard running light (light extinguished).
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 13 April 2005
Resolution: Attended vessel and observed that light is operational. Cause was a burnt bulb.
Lifesaving › Lifefloat › Serviceable
Issued 23 March 2005 Resolved
Make repairs to minor ckecks in two lifefloats.
Action required: 705 - Other - as specified
Due 23 April 2005
Resolved 13 April 2005
Resolution: Attended vessel and observed that repairs have been made to the lifefloats. All satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 May 2004 Resolved
Vessel is restricted to 84 passengers due to 40 worn life jackets.
Due 28 May 2004
Resolved 17 May 2004
Resolution: Vessel purchased 40 new life jackets. Inspected sat with lights and vessel name.
Lifesaving
Issued 11 May 2004 Resolved
Replace both lines connecting 2 forward and 2 aft life floats.
Due 28 May 2004
Resolved 17 May 2004
Resolution: Replaced all above lines. Inspected sat.
Lifesaving
Issued 28 May 2003 Resolved
Replace hydro-release on EPRIB. Vessel is restricted to no greater than 3NM
Due 28 May 2003
Resolved 29 May 2003
Resolution: Purchased and installed new hydro-release for EPRIB.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 28 May 2003 Resolved
Replace 59 adult and 10 children expired lights on these life jackets. Vessel is restricted to 75 adult and 3 children beyond 20 NM.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Inspected 59 adult and 10 children life jackets for new lights. All sat.
Lifesaving
Issued 28 May 2003 Resolved
Replace retro-tape on both first deck ring buoys.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Installed new retro-tape on both first deck ring buoys. Inspected sat.
Documentation
Issued 28 May 2003 Resolved
Post Waste Management Plan and MARPOL V placard in accomadation space.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Posted both placards. Inspected sat.
Accommodation/Occupational Safety
Issued 28 May 2003 Resolved
Replace cracked pilothose window on port side.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Installed new bridge window. Inspected sat.
Navigation
Issued 28 May 2003 Resolved
Provide current Light List Volume II and Navigation Rules publications.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Purchased both pubs. Inspected sat.
Lifesaving
Issued 28 May 2003 Resolved
Shorten ring buoy water light line to 3- 6 feet.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Shortened water light line to 5 feet. Inspected sat.
Navigation
Issued 28 May 2003 Resolved
Provide current charts 12300, 12353, 12200, 12211.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Purchased new charts. Inspected sat.
Fire Fighting
Issued 28 May 2003 Resolved
Re-stencil fire axe in pilothouse with vessel's name.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Stenciled fire axe.
Documentation
Issued 28 May 2003 Resolved
Provide update/current training log. Log incomplete.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Updated training log. Inspected sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 28 May 2003 Resolved
Mount B-I fire fighting extinguisher in pilot house.
Condition: Unknown
Due 27 June 2003
Resolved 26 June 2003
Resolution: Installed B-I bracket and extinguisher.
Accommodation/Occupational Safety
Issued 28 May 2003 Resolved
Provide eye wash in first aid kit.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Purchased new eye wash and placed in first aid kit.
Lifesaving
Issued 28 May 2003 Resolved
Replace worn life lines on top life float.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Replaced worn life lines on top life float. Inspected sat.
Operations/Management
Issued 28 May 2003 Resolved
Provide CPR cards for 50% of the crew.
Due 27 June 2003
Resolved 26 June 2003
Resolution: Master provided proof of passing test. Cards will be mailed out.
Electrical › Electrical Distribution System (service)
Issued 24 April 2002 Resolved
Prove proper operation of switchboard power available indicators. LEGACY COMPONENT DESC: Switchboard
Condition: Improper/Lack of Maintenance
Due 7 May 2002
Resolved 8 May 2002
Resolution: Received fax verification of completion by O/O.
Electrical › Electrical Distribution System (service)
Issued 24 April 2002 Resolved
Provide non-conducting matting at switchboard. LEGACY COMPONENT DESC: Switchboard
Condition: Unknown
Due 7 May 2002
Resolved 8 May 2002
Resolution: Received fax verification of completion by O/O.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 April 2002 Resolved
Post hearing conservation placard at entrance to engine room. LEGACY COMPONENT DESC: Hearing conservation
Condition: Unknown
Due 7 May 2002
Resolved 8 May 2002
Resolution: Received fax verification of completion by O/O.
Lifesaving
Issued 20 March 2002 Resolved
Expired registration sticker on EPIRB.
Condition: Unknown
Due 25 March 2002
Resolved 25 March 2002
Resolution: Placed registration sticker on EPIRB.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 20 March 2002 Resolved
Vessel name missing on three (3) adult life jackets.
Condition: Unknown
Due 25 March 2002
Resolved 25 March 2002
Resolution: Stinceled vessel name on life jackets
Lifesaving › Hand Flares
Issued 20 March 2002 Resolved
Handheld flares expired. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Due 20 April 2002
Resolved 26 April 2002
Resolution: Purchased flares. New flare on board.
Navigation › Piloting/Steering
Issued 20 March 2002 Resolved
Missing proper Light list and Coast Pilot. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Due 20 April 2002
Resolved 26 April 2002
Resolution: Purchased Coast Pilot and Light List.
Communications › Radio Communications
Issued 20 March 2002 Resolved
Missing standard marine broadcast information on bridge. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 20 April 2002
Resolved 26 April 2002
Resolution: Posted marine broadcast placard.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 20 March 2002 Resolved
Life jacket designation missing number following Adult and
Condition: Unknown
Due 25 March 2002
Resolved 25 March 2002
Resolution: Number of Adult and Child life jackets numbered.
Documentation › Logs/Records › Drug Test Records
Issued 20 March 2002 Resolved
Missing drug consortium information.
Condition: Unknown
Due 25 March 2002
Resolved 25 March 2002
Resolution: Provided information to Coast Guard on drug consortium used for crew.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 20 March 2002 Resolved
Missing cover plate on junction box.
Condition: Unknown
Due 25 March 2002
Resolved 25 March 2002
Resolution: Replaced the missing cover on junction box.
Construction/Loadline › Hull
Issued 20 March 2002 Resolved
21/4 inch holes with visible light in forepeak deck. LEGACY COMPONENT DESC: Weld
Condition: Unknown
Due 25 April 2002
Resolved 26 April 2002
Resolution: Repaired 1/4 inch holes in deck.
Deck/Cargo › Mooring/Anchoring
Issued 20 March 2002 Resolved
Wasted fittings on hydraulic system for ground tackle in forepeak.
Condition: Unknown
Due 25 March 2002
Resolved 25 March 2002
Resolution: Replaced hydraulic line fittings in forepeak.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 20 March 2002 Resolved
BI extinguisher in operating station not properly serviced. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 20 April 2002
Resolved 26 April 2002
Resolution: Serviced B-I fire extinguisher.
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 March 2002 Resolved
Missing 1 hose clamp on 2 exhaust discharge piping/hose connections.
Condition: Unknown
Due 25 March 2002
Resolved 25 March 2002
Resolution: Replaced with proper hose clamps.
Electrical › Electrical Distribution System (service)
Issued 20 March 2002 Resolved
Loose wires on top of each main. Wires just run for new starter engauge/disengauge lights for each main. Installation not yet completed. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 20 April 2002
Resolved 24 April 2002
Resolution: Wirng repairs complete.
Fire Fighting › Remote Fuel Shutoff
Issued 20 March 2002 Resolved
Emergency fuel shutoff not properly labeled with direction to open/close. LEGACY COMPONENT DESC: Labeling
Condition: Unknown
Due 20 April 2002
Resolved 24 April 2002
Resolution: Shutoff labeled and reach rod test sat.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 March 2002 Resolved
Line on liferings fish-hooking and needs replaced.
Condition: Unknown
Due 25 March 2002
Resolved 25 March 2002
Resolution: Line replaced in liferings.
Navigation › Piloting/Steering › Marine Charts
Issued 20 March 2002 Resolved
Update charts for operating area.
Condition: Unknown
Due 25 March 2002
Resolved 25 March 2002
Resolution: Charts corrected for operating area.
Engineering › Bilge Water Management System
Issued 20 March 2002 Resolved
Missing bilge high water alarms in lazzarette.. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Due 20 April 2002
Resolved 26 April 2002
Resolution: Installed bilge alarm in lazzarette.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 March 2002 Resolved
Missing one flashlight and batteries for the flashlight on board.
Condition: Unknown
Due 25 March 2002
Resolved 25 March 2002
Resolution: Batteries replaced for flashlight on board and second light also now on board and in proper working order.
Lifesaving
Issued 15 March 2001 Resolved
re-register and renw hydrostatic relief for vessel's EPIRB.
Condition: Unknown
Due 31 May 2001
Resolved 11 April 2002
Resolution: Registered EPRIB. Installed a new hydrostatic release.
Lifesaving
Issued 15 March 2001 Resolved
Replace life float lifelines on bottom two life floats in fwd stack and bottom life float in aft stack.
Condition: Unknown
Due 31 May 2001
Resolved 11 April 2002
Resolution: Installed new life float lines.
Lifesaving
Issued 15 March 2001 Resolved
Label the location and the total number of child and adult life jackets.
Condition: Unknown
Due 31 May 2001
Resolved 11 April 2002
Resolution: Labeld all life jacket stowage lockers.
Construction/Loadline
Issued 15 March 2001 Resolved
Provide an audible and visible high level bilge alarm indicator panel on bridge.
Condition: Unknown
Due 31 May 2001
Resolved 11 April 2002
Resolution: Installed panel on bridge.
Lifesaving
Issued 15 March 2001 Resolved
Label entrance to upper deck with the total number of people allowed.
Condition: Unknown
Due 31 May 2001
Resolved 11 April 2002
Resolution: Stenciled upper deck with total number of passengers allowed.
Engineering
Issued 15 March 2000 Resolved
"PROHIBITED OIL DISCHARGE" PLACARD NOT PRESENT IN MACHINERY SPACE.
Condition: Unknown
Due 15 April 2000
Resolved 3 April 2000
Lifesaving
Issued 15 March 2000 Resolved
AFFIX A LABEL INFORMING PASSENGERS AS TO THE LOCATION OF LIFE JACKETS ON THE SECOND DECK.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
ALL FLOAT LIGHTS REQUIRE NEW BATTERIES._x001C_
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
FUEL FILTER FLAME GUARDS NOT INSTALLED
Condition: Unknown
Due 15 April 2000
Resolved 3 April 2000
Lifesaving
Issued 15 March 2000 Resolved
PADDLES TO 1 OF THE 5 LF WAS NOT ATTACHED AS REQUIRED BY REGULATION.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
REFLECTIVE TAPE WAS NOT APPLIED TO BOTH SIDES OF THE LIFE FLOATS. ALL FIVELF DID NOT HAVE REFLECTIVE TAPE ON BOTH SIDES AS REQUIRED BY REGULATION.
Condition: Unknown
Due 15 April 2000
Resolved 3 April 2000
Lifesaving
Issued 15 March 2000 Resolved
MACHINERY SPACE LIGHT BULB SHIELDS NOT INSTALLED.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
52 OF THE 124 PFD'S HAD EXPIRED CHEM LIGHTS.
Condition: Unknown
Due 22 March 2000
Resolved 3 April 2000
Navigation
Issued 15 March 2000 Resolved
OUTDATED NAVIGATION PUBLICATIONS
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Lifesaving
Issued 15 March 2000 Resolved
REPAIR HOLES IN ALL LIFE FLOATS.
Condition: Unknown
Due 15 April 2000
Resolved 3 April 2000
Construction/Loadline
Issued 23 March 1995 Resolved
MAKE PERMANENT REPAIRS TO THE FOLLOWING BOTTOM PLATE FRAMING FRACTURES: _x001C_ COMPT #3: BOTTOM PLATE LONGITUDINAL STIFFENERS FRACTURED AT FORWARD BLKHD(4 PORT SIDE, 2 STBD SIDE) GRIND DOWN, VEE-OUT AND REWELD._x001C_ COMPT #3: PORT SIDE BOTTOM FRAMES 1 & 2 AT 2ND LONG SUPPORT VEE & WELD.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Documentation
Issued 23 March 1995 Resolved
PROVIDE WRITTEN PROCEDURES FROM THE MARINE EMPLOYER SHOWING THE CHEMICAL DRUG TESTING RANDOM EMPLOYEE SELECTION PROCESS USES A "SCIENTIFICALLY VALIDMETHOD" PER 46 CFR 16.230(c).
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Engineering
Issued 23 March 1995 Resolved
PREPARE THE 3,000 GAL INTEGRAL FUEL TANK FOR A USCG MARINE INSPECTOR TO CONDUCT AN INTERNAL EXAMINATION OF STRUCTURAL FRAMING NOT LATER THAN THE NEXT SCHEDULED HULL EXAM.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Documentation
Issued 23 March 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Documentation
Issued 22 March 1994 Resolved
PROVIDE WRITTEN DOCUMENTATION ON RANDOM DRUG TESTING PROCEDURES (SELECTION_x001C_OF EMPLOYEES, DATE AT A RATE OF 50% OR MORE) AND PROCEDURE FOR OBTAINING_x001C_ THE STATISICAL SUMMARY URINALYSIS TESTS AS REQUIRED BY 46 CFR 40.27
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Fire Fighting
Issued 22 March 1994 Resolved
PROVIDE 2 FIRE HOSES PRIOR TO OPERATING.
Condition: Unknown
Due 22 March 1994
Resolved 23 March 1994
Lifesaving
Issued 22 March 1994 Resolved
PROVIDE ONE LIGHT FOR ONE OF THE LIFE FLOATS PRIOR TO OPERATING.
Condition: Unknown
Due 22 March 1994
Resolved 23 March 1994
Lifesaving
Issued 22 March 1994 Resolved
MARK THE NUMBER OF LIFE PRESERVERS ON EACH BOX.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Lifesaving
Issued 22 March 1994 Resolved
PROVIDE 25 LIGHTS FOR 22 ADULT AND 3 CHILDREN LIFE PRESERVERS PRIOR TO_x001C_ CARRYING MORE THAN 99 PASSENGERS.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Accommodation/Occupational Safety
Issued 22 March 1994 Resolved
INSTALL/REPLACE THE HEATING UNIT FACE COVER AND THE COVER ON THE SWITCH_x001C_ BOX IN THE HEATING UNIT SPACE.
Condition: Unknown
Due 22 March 1994
Resolved 23 March 1994
Lifesaving
Issued 15 April 1993 Resolved
MARK ALL LIFE PRESERVER STOWAGE LOCATIONS WITH THE NUMBER OF LIFE PRESERVERS STOWED WITHIN EACH LOCATION.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Engineering
Issued 15 April 1993 Resolved
PROVIDE HANDLE FOR FUEL SHUT-OFF VALVE FOR CENTER MAIN DIESEL ENGINE IN ENGINE ROOM.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Documentation
Issued 15 April 1993 Resolved
PROVE COMPLIANCE WITH CHEMICAL DRUG TESTING AS PER 46 CFR PARTS 4,5, AND 16
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Lifesaving
Issued 15 April 1993 Resolved
PROVIDE SIX (06) ORANGE FLARES PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 April 1993
Resolved 19 April 1993
Engineering
Issued 15 April 1993 Resolved
RENEW MARKING FOR EMERGENCY FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Electrical
Issued 15 April 1993 Resolved
PROVIDE ELECTRICAL BOX CONNECTOR FOR WIRING ON SEWAGE PUMP AND FRESH WATER PUMP MOTORS.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Documentation
Issued 15 April 1993 Resolved
PROVIDE SENIOR DECKHAND DESIGNATION LETTER.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Lifesaving
Issued 15 April 1993 Resolved
PROVIDE FORTY-THREE (43) USCG APPROVED LIGHTS FOR ADULT LIFE PRESERVERS. VESSEL IS RESTRICTED TO CARRYING EIGHTY-ONE (81) TOTAL PERSONS ON OCEAN ROUTE UNTIL LIGHTS ARE PROVIDED AND ATTACHED TO LIFE PRESERVERS.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Lifesaving
Issued 15 April 1993 Resolved
VESSEL RESTRICTED TO ONE-HUNDRED NINETEEN (119) TOTAL PERSONS ON_x001C_ COASTWISE AND LAKES, BAYS AND SOUND ROUTES UNTIL FIVE (05) ADULT TYPE I USCG APPROVED LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Lifesaving
Issued 16 April 1992 Resolved
RENEW 12' PENDANTS ON THREE (03) LIFEFLOATS AND TWO (02) 18' LINES ON WATERLIGHTS FOR LIFEFLOATS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Accommodation/Occupational Safety
Issued 16 April 1992 Resolved
DEMONSTRATE RELIEF SETTING OF PRESSURE RELIEF VALVE FOR PRESSURE VESSEL.
Condition: Unknown
Due 28 July 1992
Resolved 28 July 1992
Documentation
Issued 16 April 1992 Resolved
POST MARPOL ANNEX V GARBAGE POLLUTION PLACARD IN PASSENGER AREA.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Engineering
Issued 16 April 1992 Resolved
AT NEXT DRYDOCK MAKE PERMANENT REPAIRS TO THE TEMPORARY PATCHES ON THE PORTAND STBD GENERATOR EXHAUST IN THE ENGINEROOM.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Construction/Loadline
Issued 16 April 1992 Resolved
AT NEXT DRYDOCKING REPAIR FRACTURES OF TRANSVERSE FRAME JOINTS AT #3 PORT, 5 & 6 STBD & #2 VERTICAL STANCHION IN THE 2ND COMPT, BOTTOM LONGS 3 THRU 7 AT THE AFT BLKHD OF 3RD COMPT, BOTTOM LONG FRACTURED WELD IN STERN VOID PORT AFT AREA.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Navigation
Issued 16 April 1992 Resolved
PROVIDE UPDATED/CORRECTED CHARTS AND LIGHT LIST FOR FLORIDA ROUTE PRIOR TO OPERATING ON FLORIDA ROUTE.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Navigation
Issued 16 April 1992 Resolved
PROVIDE CLASS "A" EPIRB MFG OR UPGRADED AFTER 01OCT88. ROUTE RESTRICTED TOCOASTWISE NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Engineering
Issued 16 April 1992 Resolved
REPAIR LEAK AT JABSCO COOLING WATER CIRCULATING PUMP ON PORT GENERATOR.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Navigation
Issued 16 April 1992 Resolved
REPAIR HYDRAULIC OIL LEAK (WEEPING) IN STEERING SYSTEM PIPING AT OIL TANK IN E/R STBD SIDE.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Fire Fighting
Issued 16 April 1992 Resolved
PROVIDE B-I PORTABLE FIRE EXT FOR WHEELHOUSE. PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Lifesaving
Issued 16 April 1992 Resolved
TOTAL PERSONS ON BOARD RESTRICTED TO 115 ADULTS UNTIL 9 TYPE I ADULT LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Navigation
Issued 16 April 1992 Resolved
PROVIDE CHARTS UPDATED OR A CURRENTLY CORRECTED EDITION FOR MONTAUK POINT TO CAPE CHARLES ROUTE.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Navigation
Issued 16 April 1992 Resolved
PROVIDE USCG LIGHT LIST VOL I (EDITION WITHIN 3 YRS OR UPDATED)
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Lifesaving
Issued 11 April 1991 Resolved
PROVIDE (3) CHILD PFD LIGHTS WHERE MISSING.
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Lifesaving
Issued 11 April 1991 Resolved
PROVIDE (29) ADULT PFD LIGHTS WHERE MISSING.
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Navigation
Issued 5 April 1990 Resolved
PROVIDE AN UP TO DATE LIGHT LIST (VOL. 1).
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Construction/Loadline
Issued 5 April 1990 Resolved
REWELD THE PORTSIDE INNER CHINE WHERE FRACTURED AT THE COLLISION BHD IN THEFOREPEAK.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Construction/Loadline
Issued 5 April 1990 Resolved
REWELD THE STARBOARD SIDE INNER CHINE WHERE FRACTURED AT THE COLLISION BHD IN THE 2ND COMPARTMENT.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 5 April 1990 Resolved
PROVIDE A HAND RELIEF VALVE ON THE AIR RECEIVER IN THE 3RD COMPARTMENT.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Electrical
Issued 5 April 1990 Resolved
DEMONSTRATE OPERATION OF THE GENERATOR TACHOMETERS.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 26 March 1987 Resolved
RENEW CENTER MAIN ENGINE SHAFT PACKING GLAND BOLT.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Navigation
Issued 26 March 1987 Resolved
RELOCATE PORT AND STARBOARD RUNNING LIGHTS SO THEY ARE NOT FORWARD OF THE MAST HEAD LIGHTS.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 26 March 1987 Resolved
RENEW CRACKED WELDS IN NO. 1 VOID.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Lifesaving
Issued 26 March 1987 Resolved
PROVIDE 2 CHILD LIFE JACKETS. VESSEL RESTRICTED TO CARRIAGE OF NO MORE THAN 11 CHILDREN UNTIL CORRECTED.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 26 March 1987 Resolved
RENEW CRACKED WELDS IN STEERING COMPARTMENT.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Construction/Loadline
Issued 27 January 1987 Resolved
CROP AND INSERT WASTED PORTION OF AFT ENGINE ROOM BULKHEAD BETWEEN TRANSVERSE STIFFNERS #1 AND 2 IN WAY OF OLD MSD OUTLINE.
Condition: Unknown
Due 27 January 1987
Resolved 27 January 1987
Engineering
Issued 5 June 1986 Resolved
PROVIDE LAGGING ON ENGINE EXHAUSTS UP TO WATER COOLED SECTION.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Construction/Loadline
Issued 5 June 1986 Resolved
REPAIR CRACKS TO PORT WEB IN ENGINE ROOM AT SHAFT LOG AND PORT ENGINE SUPPORT INBOARD.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Construction/Loadline
Issued 20 March 1986 Resolved
MAKE WATERTIGHT THE SQUARE CUT OUT IN MAIN DECK ABOVE AFTER STEERING AT NEXT DRYDOCK.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Navigation
Issued 20 March 1986 Resolved
PROVIDE COAST PILOT FROM SANDY HOOK, NJ TO MONTAUK POINT, NJ. UNTIL PROVIDED, VESSEL MAY NOT OPERATE IN THAT ZONE.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Construction/Loadline
Issued 20 March 1986 Resolved
PROVIDE RETAINING CHAINS FOR HATCHES IN WEATHER FOR CONNECTION TO HULL.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Lifesaving
Issued 20 March 1986 Resolved
PROVIDE SEPARATION OF CHILDREN'S LIFEJACKETS FROM ADULT JACKETS AND STENCILACCORDINGLY.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Construction/Loadline
Issued 20 March 1986 Resolved
MAKE WATERTIGHT WIRE PENETRATIONS IN ENGINE ROOM BULKHEADS.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Fire Fighting
Issued 20 March 1986 Resolved
PROVIDE PROPER BRACKETS FOR THE B-II EXTINGUISHERS.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Construction/Loadline
Issued 20 March 1986 Resolved
REPAIR CRACKED WELDS AT NEXT D/D. OUTBOARD STBD SIDE AT REVERSE CHINE AT COLLISION BHD; OUTBOARD P/S IN #2 VOID AT 1ST,2ND & 3RD FRAMES WHERE JOINEDTO LONGITUDINALS ON HORIZONTAL PLATE; JUNCTURE OF #2 VOID FWD BHD & APPROX 6 LONGITUDINALS; SBTD OUTBOARD DECK BEAM IN E/R; PORT AFT WEB IN ENGINE RM.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Lifesaving
Issued 20 March 1986 Resolved
PROVIDE SIGN AT MAIN DECK OVERHEAD AFT INDICATING LOCATION OF LIFEJACKETS.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Documentation
Issued 21 March 1985 Resolved
PERMANENTLY POST VESSEL'S STABILITY LETTER ON VESSEL.
Condition: Unknown
Due 21 March 1985
Resolved 21 March 1985

Casualty record · 1

11 December 2020Routine · role: Involved in a Marine Investigation (non-casualty) · 1 dead · activity 7115163
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.