Records from 2016 to 2026. Most recent: inspection, 17 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 32
17 March 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8331602
20 May 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8139642
16 April 2025
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8112718
21 March 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8097192
4 March 2025
Internal Structural Exam · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8087840
23 April 2024
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7899947
31 January 2024
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7864375
19 September 2023
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7794047
15 August 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7769236
4 May 2023
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7688990
27 March 2023
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7657437
28 February 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7643119
29 May 2022
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7463513
3 May 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7443307
21 October 2021
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7336909
30 August 2021
Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7298111
14 July 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7255949
28 April 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7185049
16 March 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7156699
11 December 2020
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7115163
15 April 2020
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6939517
10 April 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6937931
7 October 2019
Plan Review "T" Boat · Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6829488
22 April 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6667891
22 February 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6630761
6 September 2018
Inclining Experiment · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6534309
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6505569
17 April 2018
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6389103
25 April 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6131732
14 February 2017
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6102000
23 March 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5838678
18 February 2016
Drydock Exam · Deficiency Check · Plan Review "T" Boat · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5817632
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 March 2026
Resolved
Vessels described by 46 CFR 175.110(d) must comply with the regulations in § 177.500. Vessel's two means of escape from overnight accommodation space lead to the same compartment. Passengers cannot utilize overnight accommodations.
46 CFR 177.115(c)
Action required: 705 - Other - as specified
Due 26 April 2026
Resolved 22 July 2026
Resolution: Vessel added partition to reduce square footage of space, allowing them to only need one means of escape. Vessels existing stairs are satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 March 2026
Resolved
A ladder leading to a deck scuttle may not be used as a means of escape except:(1) On a vessel of not more than 19.8 meters (65 feet) in length, a vertical ladder and a deck scuttle may be used as not more than one of the means of escape from passenger accommodation space. Submit proposal for modifications to the satisfaction of MI.
46 CFR 177.500(j)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 22 July 2026
Resolution: Vessel added partition to reduce square footage of space, allowing them to only need one means of escape. Vessels existing stairs are satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are readily accessible and visible to the crew and passengers. Vessel has life jacket placard for only one of the three types of life jackets on board.
46 CFR 185.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 13 April 2025
Resolution: O/O replaced old lifejackets with same in kind on placards.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 March 2025
Resolved
All fittings on fire hose shall be of brass, copper, or other suitable corrosion resistant material. Nozzles on port and starboard fire hose were severely corroded.
46 CFR 181.15-10(f)
Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 21 March 2025
Resolution: Fittings provided.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 April 2024
Resolved
The scope of the annual inspection is the same as the inspection for certification... At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Due to main engine low oil pressure vessel unable to get u/w.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2024
Resolved 25 April 2024
Resolution: MDE was repaired. Got vsl u/w. Due to sea conditions drill was done dockside. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 April 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the ....operator shall be prepared to conduct tests and have the vessel ready for inspections of ...Operation of the main propulsion machinery both ahead and astern. One MDE was inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2024
Resolved 25 April 2024
Resolution: MDE Lube Oil relief valve was renewed & tested sat. Vessel was tested u/w sat.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 April 2024
Resolved
Stability information (stability details indicated a stability letter), is required on...A vessel which,...complies with requirements in subchapter S of this chapter. Vessel exceeded the limits of Stab Ltr onboard
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 25 April 2024
Resolution: The stability letter was reissued due to errors. The revised stability letter was located and posted while the exististing, incorrect, letter was discarded.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 23 April 2024
Resolved
...a test communication on a required frequency in the 1605 to 27500 kHz band...Operator was unable to demonstrate proper function of the SSB
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 25 April 2024
Resolution: SSB was tested sat by contacting a vessel in the NY Area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 April 2024
Resolved
One or more metallic shutoff valves must be installed adjacent to the fitting...two metallic shutoff valves are installed, one on either side of the bulkhead,... Vessel had flexible hoses penetrating void 2/3 WT Blkhd.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 21 March 2025
Resolution: Shutoff valves installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2024
Resolved
...Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The Port Generator RW discharge hose had several bulges. The bilge suction hose was badly worn.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 November 2024
Resolution: The generator hose was renewed 25 Apr 2024. The bilge piping was repaired with a dresser coupling 7 Nov 2024. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2024
Resolved
Auxiliary boilers and heating boilers and their associated piping and fittings will be given separate consideration and must meet the applicable requirements of subchapter F...heating boilers must be tested or examined every three years. There were no records of boiler or furnace testing. Hoses were not CG approved fire rated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 7 November 2024
Resolution: Boilers were removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2024
Resolved
Electrical installations shall be to the satisfaction of the [name withheld] cord connections were used for fixed lighting and compressor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 7 November 2024
Resolution: Installations were hard wired 25 Apr 2024 & were installed in enclosures 7 Nov 2024.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 April 2024
Resolved
..a vessel for which an extension is granted under paragraph (1)(C) shall provide on the website of such owner or operator of the vessel, the vessel, and each ticket for a passenger a prominently displayed notice that the vessel is exempt from meeting the Coast Guard safety compliance standards concerning egress as described in such section.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 17 March 2026
Resolution: Verified owner had the required wording on their website
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 May 2023
Resolved
Vessel is restricted from carrying overnight passengers until watch alert system required by 46 CFR 184.410 (b) is approved, installed, and verified by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 1 December 2023
Resolved 19 September 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 February 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel missed it's drydock that was due 28FEB23.
Vessel must complete drydock examination prior to carrying passengers. 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2023
Resolution: Drydock inspection complete.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 May 2022
Resolved
MI observed a crack in the steering scuttle outer framing/ knife edge where the gasket would sit.
46CFR176.01-10(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 30 May 2022
Resolution: re-welded the crack. Orderd and has a new hatch on hand to replace at the dry dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 May 2022
Resolved
MI observed that on the Generator switchboard the ammeter and the frequency (hertz) meter were inop.
Require vsl repair/replace equipment for proper operation.
46cfr183.10-5(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 30 May 2022
Resolution: both ammeter and frequency meters were replace and working.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 May 2022
Resolved
MI observed ground detection on the generator switchboard inop.
Require repair/replace equipment for proper operation.
46cfr111.05-21
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 3 November 2022
Resolution: Received tech report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2022
Resolved
MI observed numerous black ground cables on the engine room batteries had cuts and crack on the insulation.
Require cables be replaced with proper battery cables.
46cfr183.05-40(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 30 May 2022
Resolution: replace all cracked ground cables from batteries.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2021
Resolved
Identified misalignment of installed portable fire
extinguishers with revised regulations and policy.
Vessel has one legacy B-II CO2 fire extinguisher in ER,
with remaining fire extinguishers NFPA-10/UL rated or
dual rated w/USCG rating. In addition, when the COI was
revised to list the new performance-based rating, the
required arrangement was not updated. For the current
operating arrangements, layout, and configuration, the
VOYAGER should have (1) 10-B:C on the upper deck/
operating station, (2) 2-A w/ (1) in the main deck salon
and (1) in the below deck berthing, and (2) 40-B:C
located in the concession area outside of the Engine
Room with (1) for responding to Engine Room fires and
the other for fires in the Concession area from risk of
fire from the furnace or appliances. Vessel must add
two (2) 40-B:C extinguishers in the vicinity of the
Concession area/access to the Engine Room and replace
the 10-B:C in the Salon with a 2-A extinguisher.
CITE: CG-CVC Policy Ltr 18-04, & 46 CFR §181.500(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 2 September 2021
Resolution: Vessel added extinguisher to accommodation/salon area.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2021
Resolved
Life Ring Buoy on upper deck by wheelhouse is in
unserviceable condition. Vessel is required to have a
USCG Approved Ring Buoy w/ Light in this location.
Replace with new, approved Lighted Ring Life Buoy.
CITE: 46 CFR §180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 2 September 2021
Resolution: Life buoy was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2021
Resolved
One older Kapok PFD unserviceable (Kapok cells leaking).
Replace unserviceable PFD with new, USCG Approved PFD.
CITE: 46 CFR §180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 14 May 2021
Resolution: Replaced prior to end of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2021
Resolved
All machinery and equipment must be installed and
maintained in such a manner as to afford adequate
protection from causing fire, explosion, machinery
failure, and personnel injury. Observed significant
rusting and wastage of the end shell of the 15 gal
combined air compressor/receiver in Compartment 2.
Prove safe condition of or replace air receiver.
CITE: 46 CFR §182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 3 May 2022
Resolution: Attended vsl, observed a new air receive mounted properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 April 2021
Resolved
Electronic propulsion control systems must be designed
so that a loss of power to the control system does not
result in increased shaft speed or propeller pitch, as
per 184.620(c). A propulsion control system drawing
should be submitted along with a ‘Test Protocol’ to
verify this. The Test Protocol should consist of a
limited Qualitative Failure Analysis (QFA) and Design
Verification Test Procedure (DVTP), only including
analysis of the loss of power to the control system.
Please provide copies of the propulsion control system
drawing with Test Protocol for review.
CITE: CG-CVC_POL17-07, CG-CVC_POL17-07-RefB, & PRG.E2-23.2017.07.26
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2021
Resolved 14 July 2021
Resolution: Uploaded VOYAGER QFA-DVTP Appvl, MSC ltr E2-2102172.pdf MSC Approval Ltr of installed electronic propulsion control system's QFA/DVTP to MISLE Documents.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 May 2020
Resolved
Prove operation of the fire pump and bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2020
Resolution: Observed sat test via facetime.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 May 2020
Resolved
Repair or replace engine room bilge visual alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 May 2020
Resolution: Replaced LED.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 May 2020
Resolved
Label electrical breakers in the engine room with the circuits serviced.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 May 2020
Resolution: Labeled breakers
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2020
Resolved
Provide a sign stating the upper deck is limited to 50 person in accordance with the stability letter. Remove sign that states 60 persons.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 May 2020
Resolution: Affixed new sign.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 April 2020
Resolved
Complete COI Renewal inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2020
Resolved 1 May 2020
Resolution: COI inspection completed #6939517
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2019
Resolved
Vessel has two fire hydrants and only one spanner. Provide additional spanner. 16C 46 CFR 181.310(d).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2019
Resolution: Vessel purchased spanner wrench.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: No static draft information.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 6 November 2018
Resolution: AIS information updated.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 April 2018
Resolved
Place machinery guards around rotating machinery on the main propulsion engines.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 June 2018
Resolved 30 April 2018
Resolution: Guards were placed on the exposed belts.
Engineering › Fuel Oil Service System › Filter
Issued 17 April 2018
Resolved
PG02. Place plugs or caps on all fuel strainers in the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2018
Resolved 20 April 2018
Resolution: The crew placed caps on the Racor fuel filters. Photos are in MISLE.
Construction/Loadline › Penetrations › Valve Flange
Issued 14 February 2017
Resolved
Replace sea chest valve on generator.
Condition: Improper/Lack of Maintenance
Due 9 March 2017
Resolved 8 March 2017
Resolution: Recieved pictures of new valve. Attached in documents.