MAURY USCG vessel records Sign in
← All vessels

STIM STAR III

STIM STAR III is a 2002 offshore supply vessel. The Coast Guard has recorded 37 inspections since 2002, most recently in March 2026, along with 70 deficiencies — 1 with no resolution recorded — and 4 casualty investigations between 2007 and 2025.

Records from 2002 to 2026. Most recent: inspection, 5 March 2026.

Built
2002
Last inspected
5 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9274991 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA7484
512765
Flag
UNITED STATES
369050000
Maury page id
psix-512765

Inspections, by type

…with no type recorded5
Years with a record 20 calendar years (2002–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)243.5 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 3,191 / net 957
ITC dimensions (L × B × D)243.5 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 3,191 / net 957
BuilderNORTH AMERICAN FABRICATORS LLC · HOUMA, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 24 February 2026 · expires 31 March 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3191 - Convention (Subpart B), Gross Ton
957 - Convention (Subpart B), Net Ton
2511 - Dead Weight, Ton
5186 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA7484MMSI 369050000 · active · compulsorily equipped · granted 24 March 2022, expires 23 March 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CANDY BASKET Passenger (Inspected) · MISLE 441638 · 7 May 2003 · activity 1792175STIM STAR II Offshore Supply Vessel · MISLE 472063 · 7 May 2003 · activity 1792175

Inspection history · 37

5 March 2026 Deficiency Check · Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8312002
21 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8191582
21 July 2025 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8191616
8 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8130827
22 October 2024 Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8036938
2 April 2024 MTSA/ISPS Verification · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7888522
15 February 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7636827
22 November 2022 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7598749
2 July 2022 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7493494
23 November 2021 COI Inspection · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7356311
4 March 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7150007
12 February 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6909115
18 October 2019 Internal Structural Exam · Cargo Tank Internal · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6836815
25 January 2019 Periodic Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6836525
22 December 2017 Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6327817
29 December 2016 MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex II Examination · COI Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6062781
14 November 2016 Cargo Tank Internal · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6040917
24 February 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5821422
1 May 2014 MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4847631
17 January 2012 Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4224357
2 April 2009 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3453106
22 May 2008 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3284866
22 April 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3201886
27 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245404
18 July 2007 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2999686
7 June 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2956191
7 June 2007 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2958519
10 April 2007 Administrative Inspection · Examination of Repairs · Cargo Tank Internal · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2911943
12 June 2006 Re-Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2679454
27 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502152
14 June 2005 Re-Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2390561
1 April 2005 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2340642
25 August 2004 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2176703
4 May 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2058740
10 June 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1813783
7 May 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1792175
24 April 2002 Cargo Tank Internal · Internal Structural Exam · Hull Examination · Inclining Experiment · Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1609019

Deficiency record · 70

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 March 2026 Resolved
The circuit breaker of a generator to be operated in parallel with another generator must comply with §§ 111.12-11(f). When testing #1 generator to drop power and #2 take load, #2 would alarm in reverse power while #1 would alarm in over/under voltage and both drop from bus. When testing for #2 to drop load and #1 take load, system functioned as should with #2 alarming in reverse power and #1 taking load. Have system service to function so both generators take load in the event of reverse power on either generator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 March 2026
Resolution: Tested with CAT tech.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2026 Resolved
Each propulsion-control system, including one operable from the pilothouse, must be designed so that no one complete or partial failure of an easily replaceable component of the system allows the propulsion engine to overspeed or the pitch of the propeller to increase. Unable to test overspeed protection due to malfunction on speed control on both MDE's. Show testing of MDE's that overspeed protection is functioning.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 13 March 2026
Resolution: Tested with CAT tech.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 March 2026 Resolved
Each lighting fixture and lampholder must be fixed. Light in frac house hanging by power cable and not support. Install is intended.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 March 2026
Resolution: Installed in original location to over head.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 March 2026 Resolved
Each vessel must be designed and constructed to minimize fire hazards, as far as reasonable and practicable. Fire protection lagging in the frac house was torn and falling down. Have replaced and/or fixed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2026
Resolved 14 April 2026
Resolution: Rep provided photo evidence of lagging installed, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 March 2026 Resolved
Nothing in this part shall be construed as limiting the inspector from making such tests or inspections as he or she deems necessary to be assured of the safety and seaworthiness of the vessel. Penetration in overhead of frac house was not sealed. Have penetration sealed/corrected.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 March 2026
Resolution: Removed air hose and screwed in plug, sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 March 2026 Resolved
Except in an emergency, no repairs or alterations to the hull or machinery, or to equipment that affects the safety of the OSV, may be made without notice to the cognizant OCMI in the inspection zone where the repairs or alterations are to be made. When the repairs or alterations have been made, notice must be given to this OCMI as soon as practicable. #4 dry bulk piping after valve had a hole leaking water. Have piping repaired to acceptance of attending MI.
Action required: 10 - Deficiency Rectified
Resolved 13 March 2026
Resolution: Welders removed section of piping from clamps, ground down area and welded area. Company plans to fully replace piping section during dry dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 12 March 2026 Resolved
Each vessel must meet the applicable requirements in subchapter S of this chapter. Class 1 WTD in frac house did not seal and was hard to open. Have corrected to make watertight.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 March 2026
Resolution: Crew changed out gasket for new, made adjustments to hinges and dogs, sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 March 2026 Resolved
Surveillnce requirements under 46 U.S.C 4901 requires notice to all crew of surveillance to be posted of video and audible. Notice was not posted on doors or passageways. Vessel rep printed stickers and had posted under cameras and on entry doors. 46 U.S.C. 4901
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 March 2026 Resolved
Each fire station must have at least one length of fire hose. While testing all hoses with fire pump @ 155 psi, a hose ruptured at the fitting. Vessel had spare, cut bad hose and replaced with new.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 March 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 March 2026 No resolution recorded
Each vessel must meet the applicable requirements in subchapter S of this chapter. Doors to CO2 rooms on top of frac house are wasted along with edges. Have fixed and/or replaced at next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2027
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2025 Resolved
Lost of pitch control in pilot house report. Each propulsion-control system operable from the pilothouse must enable. Control of propeller pitch, if a controllable-pitch propeller is fitted. Control of propeller pitch must be reestablished to pilothouse.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2025
Resolved 22 July 2025
Resolution: Tech discovered bad relay and replaced relay. Pilothouse now has the ability to control pitch.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 May 2025 Resolved
Ships shall be subdivided into spaces by thermal and structural divisions in order to contain fire and smoke in the space of origin. There is a hole low in the aft bulk-head of blender in way to the frack-house. 74 SOLAS II-2/8 and II-2/9
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 May 2025
Resolution: Crew corrected.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 May 2025 Resolved
Fire resistance of doors shall be equivalent to that of the division in which they are fitted. Fire-doors fitted in boundary bulkheads shall be self-closing. Self-closing B Class Fire-door between blender room and frackhouse on the portside was held open with a rope and self-closing mechanism was inoperable. 74 SOLAS II-2 9.4.2
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 8 May 2025
Resolution: Removed rope and self-closing mechanism corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 May 2025 Resolved
Each opening in a bulkhead in a machinery space must have means to make it watertight. Aft watertight door of pump-room on the portside leading to aft deck couldn't be closed.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 9 May 2025
Resolution: Vessel rep confirmed WT door secured tightly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 May 2025 Resolved
Fire resistance of doors shall be equivalent to tha of the division in which they are fitted. Fire-doors fitted in boundary bulkheads shall be self-closing. Self-closing B Class Fire-door between galley and kitchen was self-closing but didn't latch closed. 74 SOLAS II-2 9.4.2
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 29 August 2025
Resolved 8 May 2025
Resolution: Fire door latch was corrected and is now self closing.
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 8 May 2025 Resolved
Ships must be provided with a DSC in GMDSS that can initiate the transmission of vessel position. GMDSS is operational, but the DSC can't point at vessel's location. 47 CFR 80.1085
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 9 May 2025
Resolution: Technician came onboard to integrate vessel position in DSC.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 April 2024 Resolved
Doors fitted in boundary bulkheads of category A machinery spaces shall be self closing. The self closing mechanism on the door to the FRAC machinery space was corroded and not functioning.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 3 April 2024
Resolution: Rep provided video of self-closing door functioning as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2024 Resolved
Electrical equipment on a vessel must be maintained to provide service necesary for safety in normal and emergency operating conditions. There were exposed dead end wires under the fuel filter storage area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 10 April 2024
Resolution: Received photos of repaired electrical connections.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 April 2024 Resolved
Records of daily hours of rest must be maintained onboard the vessel. Logs of daily rest were not kept. provide Logs at next topside.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2025
Resolved 8 May 2025
Resolution: Reviewed rest hours logged on vessel's computer.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 2 April 2024 Resolved
Onboard a seagoing vessel of 1,000 HP or more, no person may serve as an RFPEW unless the person serving holds a valid, appropriate STCW endorsement. A crew member was serving as an RFPEW without the appropriate endorsement. Provide at next topside.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 April 2025
Resolved 8 May 2025
Resolution: Identified all engine room crew held RFPEW endorsements.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 2 April 2024 Resolved
Ships shall be fitted with a system to automatically transmit the information specified in paragraph 5. The LRIT conformance test report on board was not from the system actually present on the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 22 April 2024
Resolution: Received new LRIT conformance test report for installed system, uploaded into documents.
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 2 April 2024 Resolved
The Type II retro-reflective tape must be in accordance with IMO resolution A.658(16). The retro-reflective tape present on the rescue boat was not in accordance with the IMO resolution.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 3 April 2024
Resolution: Rep sent pictures of rescue boat with proper Retro-reflective tape installation.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 2 April 2024 Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. There are holes in the bulhead of the entrance to the FRAC pump room. Make temp repairs now and permanent repairs at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2024
Resolved 6 June 2024
Resolution: Cleared on bhealf of [name withheld] were completed and photos issued to CG inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 15 February 2023 Resolved
Assigned class authority shall make an annual survey of each vessel holding an appropriate certificate issue under this subchapter. Class to endorse International Load Line Certificate for annual survey.
Action required: 702 - Prior to embarking on international voyage
Resolved 16 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 22 November 2022 Resolved
13 NOV 22 Actuator for rescue boat davit failed during monthly test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2022
Resolved 23 November 2022
Resolution: Replaced actuator and tested. ABS Verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 March 2021 Resolved
Electric equipment must be arranged to prevent damage to equipment from accumulation of dust, oil vapors, etc. Windings on the No. 1 forward generator are needing cleaning.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 15 March 2021
Resolution: Cleared to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 March 2021 Resolved
Each rudder angle indicator system must have a transmitter at the rudder with the angular movement of the rudder transmitted to a remote indicator. Rudder angle indicator for port rudder in aft steering has a 10 degree variance to rudder angle indicator on bridge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 9 March 2021
Resolution: Cleared to satisfaction of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2020 Resolved
All electrical installations in hazardous locations shall comply with IEEE45-1998 and NFPA NEC 2002. Electrical installations in pump room were found using non-approved extenstion cords; lighting fixtures at hose reel found with damaged wires and exposed conductors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2020
Resolution: Electrician corrected wiring issues.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2020 Resolved
Means shall be provided for closing all openings to a space protected by a CO2 extinguishing system. Aft bulkhead in pumproom can't be made gas tight due to damaged cable and pipe penetrations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2020
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 February 2020 Resolved
The fire integrity of divisions in structural fire protecction shall be maintained at openings and penetrations. Multiple fire doors in "client spaces" found not closing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2020
Resolution: ABS Surveyor [name withheld] witnessed correction of fire doors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2020 Resolved
Each pressure vessel in service must be examined every five years. Two pressure vessel in client spaces have not been examined.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2020
Resolution: CIV Manning received correspondence from vsl rep. The air receiver has been removed from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 14 February 2020 Resolved
All lifesaving appliances shall be maintained ready for immediate use. Rescue boat found with a crack in the hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 14 February 2020 Resolved
The master shall make periodic inspections of all spaces. Client spaces found with excessive oil on decks creating a hazard to personnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 February 2020
Resolution: Crew cleaned spaces and removed hazards.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 February 2020 Resolved
Each class 1 WTD must be capable of withstanding a head of water. Several WTD in client spaces found not capable of being made water tight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2020
Resolution: Crew made doors water tight and ABS surveyor [name withheld] attested to completion.
Engineering › Steering Gear System › Power Unit
Issued 29 December 2016 Resolved
Each vessel is required to have either a main and auxillary steering or two identical main power units. Vesel's STBD #1 power unit for steering is inoperable due to fault on emergency switchboard. Correct prior to movement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2017
Resolution: Vessel provided satisfactory evidence to clear DEF.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 February 2016 Resolved
Remove air conditioner and refrigerator from conex box located in hazardous zone.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 4 March 2016
Resolution: Received documentation from vessel rep showing the hazards were removed and the access was covered with a plate.
Lifesaving › Inflatable Liferafts › Capacity
Issued 1 May 2014 Resolved
The vessel did not have enough liferafts on board IAW SOLAS. Vessel has one 25 man and one 20 man raft on each side of the vessel. Loss of the largest raft on either side does not allow for 100% support of the crew IAW SOLAS Chapter III Reg 31 1.3 for 30 persons. Vessel must install a 10man liferaft that is easily transferable to either side to come into compliance prior to international voyage
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 March 2015
Resolution: A ten man life raft had been installed on both port and stbd side so that one life raft did not have to be transferred fm side to side.
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 22 April 2008 Resolved
Provide one barrel of containment at emergency generator fuel vent.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 22 April 2008 Resolved
Renew emergency lighting in client space, all e-lights not working off emerg. generator.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 April 2008 Resolved
Remount control box in client space.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Electrical › Electric Supply System (service) › Cable
Issued 22 April 2008 Resolved
Provide metal banding for overhead wire in client space.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 22 April 2008 Resolved
Remove all non-intrinsically safe equipment in client space, ie.. tread mill
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 22 April 2008 Resolved
Replace rusty/worn latch for damper release mechanism.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 22 April 2008 Resolved
Provide Solas exit signs in passageways of client spaces.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 22 April 2008 Resolved
Renew watertight doors automatic closure devices for CO2 protected spaces, doors do not close automatically.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 22 April 2008 Resolved
Provide air receiver on 01 deck for internal inspection or provide U1-A.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 April 2008
Construction/Loadline › Penetrations › Gasket
Issued 22 April 2008 Resolved
Renew gasket and adjust emergency escape hatch in steering room.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Fire Fighting › Fire Hydrants › Condition
Issued 22 April 2008 Resolved
Remove chain in front of box, blocking fire station #13.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 22 April 2008 Resolved
Renew SCBA air tank to fire suit at fire station #13, bottle is past hydro date.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 22 May 2008
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 12 June 2006 Resolved
Provide/ install approved electrical mat at emergency switchboard.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 12 June 2006
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 12 June 2006 Resolved
Renew SOLAS reflective tape on life rings as discussed.
Action required: 705 - Other - as specified
Resolved 12 June 2006
Stability › Watertight Integrity › General
Issued 12 June 2006 Resolved
Adjust water tight door, renew gaskets & dogs as discussed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2006
Accommodation/Occupational Safety › Heating › Heating Fuel
Issued 12 June 2006 Resolved
Display steam table emergency shut down placard in galley.
Action required: 705 - Other - as specified
Resolved 12 June 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 June 2006 Resolved
Demonstrate proper operation of OWS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2006
Stability › Watertight Integrity › General
Issued 12 June 2006 Resolved
Adjust engine room WTD closer on main deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2006
Communications › Audible Communications › Horn/Whistle
Issued 12 June 2006 Resolved
Prove proper operation of stbd horn.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 June 2005 Resolved
Make compass light operable prior to night-time operations and by 15 JUL 2005.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 20 July 2005
Resolution: Compass light installed.
Fire Fighting › Fire Main › Pressure
Issued 14 June 2005 Resolved
Provide and install 125 psi relief valve for the main and emergency fire pumps by 15 JUL 2005.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 20 July 2005
Resolution: Installed 125 psi relief valves.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 14 June 2005 Resolved
Make permanent repairs to dry bulk piping by 15 JUL 2005
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 20 July 2005
Resolution: Repairs completed to piping.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 June 2005 Resolved
Demonstrate proper operation of the oily water separator prior to 15 JUL 2005. All oily waste shall be retained onboard or removed to an approved facility.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 20 July 2005
Resolution: Demonstrated proper operation of OWS.
Fire Fighting › Fire Hoses › Material
Issued 10 June 2003 Resolved
RENEW ENGINE ROOM HOSES WITH GREATER THAT 150 PSI HOSES.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 July 2003
Resolved 11 June 2003
Navigation › Piloting/Steering
Issued 10 June 2003 Resolved
REPAIR PILOT HOUSE STEERING PUMP POWER AVAILABLE LIGHTS. LEGACY COMPONENT DESC: STEERING ALARMS
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 11 June 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 10 June 2003 Resolved
PROVIDE AND POST LIQUID MUD TRANSFER PROCEDURES AT LIQUID MUD PUMPS. LEGACY COMPONENT DESC: TRANSFER PROCEDURES
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Fire Fighting › Fire Main
Issued 10 April 2002 Resolved
Replace firemain relief valve, or set to a max of 150 p.s.i. Fire stations closest to fire pump are only rated for 150 psi. LEGACY COMPONENT DESC: Valves
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 6 May 2002
Resolution: Relief valve lowered to 150 psi.
Fire Fighting › Fire Main
Issued 10 April 2002 Resolved
Redirect firemain relief. (Flooding hazard) LEGACY COMPONENT DESC: Valves
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 6 May 2002
Resolution: Firemain repiped into sea chest.
Construction/Loadline › Structures
Issued 10 April 2002 Resolved
Demonstrate proper operation of vent closure to emergency generator room. LEGACY COMPONENT DESC: Ventilators
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 10 May 2002
Resolution: Securing devices added, assisting in proper operation.
Engineering › Fuel Oil Service System
Issued 10 April 2002 Resolved
Demonstrate proper operation of remote fuel transfer pump shut downs (Haliburton). LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 6 May 2002
Resolution: All remote stops tested and verified.
Personnel › Training
Issued 10 April 2002 Resolved
Demonstrate proper man-overboard and firefighting drills. LEGACY COMPONENT DESC: Personal Safety/Social Responsibilities
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 6 May 2002
Resolution: Drills passed.
Electrical › Electric Generation Source (service)
Issued 10 April 2002 Resolved
Demonstrate load shed, overspeed, and reverse power relay of the SSDG's.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 6 May 2002
Resolution: Switch board operations sat.
Fire Fighting › Portable Foam Applicators
Issued 10 April 2002 Resolved
Provide proper fire fighting equipment for well stim equipment. (Foam applicators missing)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2002
Resolved 6 May 2002
Resolution: Proper fire fighting equipment provided.

Casualty record · 4

7 June 2007Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2956191
4 December 2012Routine · role: Involved in a Marine Casualty · activity 4497405
24 March 2013Routine · role: Involved in a Marine Casualty · activity 4557038
21 July 2025Routine · role: Involved in a Marine Casualty · activity 8191616
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.