Records from 1985 to 2025. Most recent: inspection, 11 June 2025.
Documentation record
Registered dimensions (L × B × D)32.2 ft × 10.0 ft × 3.2 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPAYNE & FRANKLIN · N. KINGSTOWN, RI, UNITED STATES · built 1980
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Gross Ton
6 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 46
11 June 2025
Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8120098
24 April 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7887048
12 June 2023
Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7694676
18 August 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7036150
13 June 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6712138
6 May 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6677670
19 June 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6448251
13 June 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6174250
14 June 2016
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5906879
18 June 2014
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4892463
12 June 2012
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4341921
3 May 2012
Simplified Stability Test · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4304633
13 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4207363
30 March 2010
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3707076
10 June 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3232916
13 June 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2960179
14 June 2006
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2679403
15 June 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2391120
13 April 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2350882
16 June 2004
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2097954
11 June 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1814131
1 May 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1611181
9 April 2002
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1602793
2 May 2001
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1410546
25 October 2000
Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1366021
26 July 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1451588
9 March 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1393362
25 May 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 784252
10 June 1998
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 791546
4 June 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1109656
12 June 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 879207
7 June 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 876946
22 May 1995
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 872461
8 June 1994
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1023218
17 June 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1136051
10 June 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1268431
9 June 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1257828
11 June 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 917113
31 May 1990
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 924838
18 January 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1236841
30 May 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1342097
17 May 1988
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1351269
14 May 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1332061
16 May 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1303766
21 May 1985
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 989660
15 March 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1288867
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 June 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 10 life jackets were found in a non-serviceable condition, but the vessel was carrying 06 life jackets in excess. Replace 04 life jackets on board. Vsl limited to a maximum of 23 total persons until deficiency rectified to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 16 July 2025
Resolution: Operator replaced the required amount of PFDs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2025
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The lanyard and the ring life buoy grab line was deteriorated. Replace lanyard and grab line to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 16 July 2025
Resolution: Grab line and floating waterlight lanyard replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 June 2025
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters consisting of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens were not the correct mesh size. Replace flame screens to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 16 July 2025
Resolution: Flame screen for port fuel vent replaced.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 June 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions were not posted on board. Post emergency instructions to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2025
Resolved 16 July 2025
Resolution: Operator added emergency instructions to captains binder.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 June 2019
Resolved
A submersible electric bilge pump may be used provided a positive shutoff valve is installed at the hull penetration. No valve is installed at the hull penetration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 25 June 2019
Resolution: Valve was installed at thru hull.
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2011
Resolved
Vessel has not verified compliance with new AAWP (185lb) standard. Total persons allowed on board as per the current COI is now reduced from 31 to 23.
Due 1 June 2012
Resolved 3 May 2012
Resolution: Simplified stability test was completed 3MAY2012 on the PATRICK TRACY JACKSON, O.N. D634854, at Lowell, MA. [name withheld] and [name withheld] in attedance for Sector Boston. Stability test found that vessel can carry 27 passengers in protected waters.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2004
Resolved
Update expired items in first aid kit.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 16 June 2004
Resolved
Install donning placards for 2 types of life jackets.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Electrical › Electrical Distribution System (service) › Switch
Issued 16 June 2004
Resolved
Label bilge alarm switch to be "ON" while operating.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 June 2004
Resolved
Mount flashlight by operating station.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Lifesaving
Issued 10 June 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Lifesaving
Issued 11 June 1991
Resolved
PRIOR TO CARRYING PASSENGERS CONDUCT EMERGENCY DRILLS WITH OPERATORS AND DECKHANDS AS OUTLINED IN NAVIC 1-91 DTD 20 FEB 91 IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991