Records from 2002 to 2007. Most recent: inspection, 5 July 2007.
Documentation record
Tonnage as PSIX records it325 - Convention (Subpart B), Gross Ton
96 - Regulatory (Subpart C or D), Gross Ton
97 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
5 July 2007
Internal Structural Exam · MARPOL Annex II Examination · MTSA/ISPS Verification · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2983966
8 March 2007
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2891499
5 April 2006
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2616650
23 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571408
26 April 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2342433
4 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303744
10 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290227
19 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2244458
29 June 2004
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2114753
23 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2051145
29 March 2004
Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2033628
25 June 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1826347
8 March 2002
Initial Certification · Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1492245
Construction/Loadline › Structures › Ventilators
Issued 8 March 2007
Resolved
COMPLETE ALL WELDING REPAIRS TO CRACKED WELDS AS MARKED.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2007
Resolved 8 March 2007
Resolution: COMPLETED
Communications › Radio Communications › EPIRB
Issued 8 March 2007
Resolved
RENEW EPIRB ANTENNA.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2007
Resolved 8 March 2007
Resolution: COMPLETED
Operations/Management › Drills/Instruction › Safety Orientation
Issued 8 March 2007
Resolved
DISPLAY CORRECT DONNING PLACARD FOR LIFE JACKETS AT NOTED AREAS.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2007
Resolved 8 March 2007
Resolution: COMPLETED
Construction/Loadline › Structures › Superstructure
Issued 8 March 2007
Resolved
INSTALL THIRD CHAIN SAFETY RAIL AT STERN RAIL.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2007
Resolved 8 March 2007
Resolution: COMPLETED
Engineering › Diesel Engine (propulsion-direct drive)
Issued 2 April 2004
Resolved
Repair exhaust leak on the #5 main diesel engine exhaust as required by 46 CFR 182.430(b). LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 2 April 2004
Resolution: Inspected the repair of the exhaust leak on the #5 main diesel engine.
Construction/Loadline › Hull
Issued 29 March 2004
Resolved
Arrest, gouge and reweld crack in starboard rudder. LEGACY COMPONENT DESC: Rudder
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 March 2004
Resolved 29 March 2004
Resolution: Inspected the proper repair of the crack in the starboard rudder.
Communications › Radio Communications
Issued 29 March 2004
Resolved
Install new hydrostatic release for the EPIRB as required by 46 CFR 180.64. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 2 April 2004
Resolution: Inspected the installation of a new hydrostatic release for the EPIRB.
Fire Fighting › Means of Escape
Issued 25 June 2003
Resolved
Make repairs to engine room escape hatch and ladder to 01 deck by welding. LEGACY COMPONENT DESC: Escape Hatch
Action required: 705 - Other - as specified
Due 25 July 2003
Resolved 25 June 2003
Lifesaving › Buoyant Apparatus
Issued 25 June 2003
Resolved
Make repairs to stbd top lifefloat. LEGACY COMPONENT DESC: Lifefloat
Action required: 17 - Rectify deficiencies prior to departure
Due 25 July 2003
Resolved 25 June 2003