Records from 2001 to 2023. Most recent: inspection, 18 January 2023.
Inspection history · 27
18 January 2023
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7623352
2 August 2022
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7521862
22 February 2022
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7376607
6 January 2022
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7429346
28 October 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7085810
16 July 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7008492
24 October 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6841082
5 August 2019
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6773210
30 August 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6527805
3 July 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6465464
2 November 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6297714
22 March 2017
Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6109500
8 November 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6037272
6 July 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5931543
29 October 2015
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5753423
19 March 2014
Drydock Exam · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4818869
2 December 2011
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4249524
16 April 2009
DAPI Audit · Deficiency Check · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3412276
7 April 2008
Internal Structural Exam · Re-Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3154625
10 April 2007
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2854302
31 March 2006
Hull Examination · Re-Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2613481
21 July 2005
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2434489
14 June 2005
Administrative Inspection · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2391313
16 July 2004
Annual Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2138118
15 July 2003
Annual Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1912568
18 April 2002
Initial Certification
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1605902
26 July 2001
Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1606366
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 February 2022
Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator must be provided. Amp meter inoperable.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2022
Resolved 31 August 2022
Resolution: Verified ammeter's operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 22 February 2022
No resolution recorded
Glass and other glazing material used in windows accessible to passengers and crew must be of material that will not break into dangerous fragments if fractured. STBD aft 3 large windows are broken, replace in kind.
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 January 2022
Resolved
The vessel must undergo an annual inspection within 3 months before or after each anniversary date. The vessel anniversary date is beyond the 3 month window. The vessel must be inspected and issued a new certificate of inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2022
Resolved 22 February 2022
Resolution: Completed COI exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 August 2018
Resolved
All cable and wiring must be protected from the environment, install covers on shore-tie connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2018
Resolved 18 September 2018
Resolution: RCVD pictures of both port and starboard side shore-tie connections with covers designed by manufacturer.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 November 2017
Resolved
Repair jacket water temperature gauage at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 16 November 2017
Resolution: Repaired jacket water temperature gauge.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 November 2017
Resolved
Replace wasted hose on A/C line, port side #2 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 16 November 2017
Resolution: Repaired wasted hose on A/C line, port side #2 void.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 November 2017
Resolved
Replace sea strainer cap to allow maintenance for A/C system in #3 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 16 November 2017
Resolution: Replaced sea strainer cap for A/C system in #3 void.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 November 2017
Resolved
Replace hose on #2 A/C cooling pump in #3 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 16 November 2017
Resolution: Replaced hose on #2 A/C cooling pump in #3 void.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 November 2017
Resolved
Replace wasted hose for sink drains on starboard side in lazerette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 16 November 2017
Resolution: Replaced wasted hose for sink drains on starboard side in lazerette.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 November 2016
Resolved
Replace raw water hose on port m/e. Hose dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 4 January 2017
Resolution: New hose installed.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 8 November 2016
Resolved
ST02- Replace broken window on STBD side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 4 January 2017
Resolution: New window installed.
Engineering › Bilge Water Management System › Strainer
Issued 29 October 2015
Resolved
Strainer in compartment 3 is broken; repair or renew.
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 13 November 2015
Resolution: The sea strainer in compartment 3 was replaced; all SAT.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 29 October 2015
Resolved
Starboard damper found inoperable; repair.
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 13 November 2015
Resolution: Starboard damper was repaired and operationally tested SAT.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 29 October 2015
Resolved
Lazarette hatch found not watertight; make watertight.
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 13 November 2015
Resolution: Lazerette hatch was grinded down and is now watertight; all SAT.
Documentation › Certificates/Documents › Stability Letter
Issued 2 December 2011
Resolved
The vessel's total persons allowed has been reduced to 132 persons with no more than 60 persons on the upper deck. This requirement is effective until you come into compliance with the requirements of the new stability regulations.
Action required: 705 - Other - as specified
Due 2 December 2011
Resolved 24 April 2013
Resolution: Vessel issued new Stability Letter and COI
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 April 2009
Resolved
Provide retro on one ring life buoy
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 7 May 2009
Resolution: Ring life buoy had new retro.
Construction/Loadline › Structures › Superstructure
Issued 16 April 2009
Resolved
Repair cracked window on port side fwd on main deck.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 7 May 2009
Resolution: New window installed.
Construction/Loadline › Structures › Manhole
Issued 16 April 2009
Resolved
Provide suitable means to attach aft deck hatch to vsl.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 7 May 2009
Resolution: Hatch was attached to deck.
Lifesaving › Lifefloat › Painter
Issued 10 April 2007
Resolved
Replace life float painter(s) - two(2).
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2007
Resolved 11 April 2007
Resolution: Painters replaced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 April 2006
Resolved
Owner /operator changed, COD expires 30APR
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 30 April 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 July 2005
Resolved
Prove servicing of fixed fire system for the E/R.
Due 22 July 2005
Resolved 11 August 2005
Resolution: 08/11/05: Vessel Had Roybal Fire extinguishing services of Middletown, CT perform an annual servicing of installed fire extinguishing system. DEF cleared
Communications › Radio Communications › VHF Radiotelephone
Issued 14 June 2005
Resolved
Provide FCC certs/station lic, safety cert.
Due 10 July 2005
Resolved 21 July 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 June 2005
Resolved
Provide Nav pubs, charts, coast pilot, nav rules, tide tables, currents, notice to mariners.
Due 10 July 2005
Resolved 21 July 2005
Resolution: Sighted
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 14 June 2005
Resolved
Provide logs for bridge, training, life saving eq.
Due 10 July 2005
Resolved 21 July 2005
Communications › Visual Communication › Red Warning Signal
Issued 14 June 2005
Resolved
provide signaling devices, 3 smoke, 3 red flares
Due 10 July 2005
Resolved 21 July 2005
Resolution: Sighted
Communications › Radio Communications › VHF Radiotelephone
Issued 14 June 2005
Resolved
Provide emg broadcast placard
Due 10 July 2005
Resolved 21 July 2005
Resolution: Sighted
Lifesaving › Lifefloat › Paddle
Issued 14 June 2005
Resolved
Provide paddles for the life floats, 14
Due 10 July 2005
Resolved 21 July 2005
Resolution: Sighted.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 14 June 2005
Resolved
Provide working float light for ring buoy.
Due 10 July 2005
Resolved 21 July 2005
Resolution: Sighted
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 June 2005
Resolved
Provide first aid kit.
Due 10 July 2005
Resolved 21 July 2005
Resolution: Sighted
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 June 2005
Resolved
service portable fire extinguishers
Due 10 July 2005
Resolved 21 July 2005
Resolution: Sighted tags.
Stability › Watertight Integrity › General
Issued 14 June 2005
Resolved
Repack shafts, both leaking at the dock with little or no adjustment left.
Due 10 July 2005
Resolved 21 July 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 14 June 2005
Resolved
Lable life jackets with vessel name.
Due 10 July 2005
Resolved 21 July 2005
Resolution: Sighted
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 April 2002
Resolved
Lifejacket donning placard missing.
Condition: Unknown
Due 18 April 2002
Resolved 18 April 2002
Lifesaving › Lifebuoys › Stowage
Issued 18 April 2002
Resolved
Lifebuoy missing detachable clip for light.
Condition: Unknown
Due 18 April 2002
Resolved 18 April 2002
Operations/Management › Equipment Service/Testing › EPIRB
Issued 18 April 2002
Resolved
EPIRB needs to be registered to vessel.
Due 18 April 2002
Resolved 18 April 2002
Documentation › Markings/Placards
Issued 18 April 2002
Resolved
Label pull stations for fire and ventilation.
Condition: Unknown
Due 18 April 2002
Resolved 18 April 2002
Stability
Issued 18 April 2002
Resolved
Permanent ballast not permanently installed. LEGACY COMPONENT DESC: Ballast
Condition: Improper Installation
Due 18 April 2002
Resolved 18 April 2002