Records from 2002 to 2015. Most recent: operational control imposed, 8 September 2015.
Inspection history · 7
8 September 2015
PII Safety Exam · Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5232206
3 November 2008
PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3346581
27 March 2006
ISPS III Exam · NPV Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2610108
16 March 2006
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2603443
13 March 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2601766
5 April 2005
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2326735
11 March 2002
Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1491602
Lifesaving › Lifeboat › Propulsion Starting System
Issued 8 September 2015
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Crew was unable to start the vessel's starboard side lifeboat after several attempts. 74SOLAS(09cons) III/20.2 - Action taken: 30abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2015
Resolved 9 September 2015
Resolution: Life boat engine was repaired by vessel's crew and hired technicians from Diesel Electric Marine. PSCO attended the vessel and witnessed successful operation of the life boats engine.
Construction/Loadline › Penetrations › Valve Flange
Issued 17 October 2008
Resolved
Seachest valve, starboard side, leading to Marine Growth Prevention System, has a temporary repair for a leak. The repair has not been approved by Class and failure of the repair would cause flooding of the Engine Room. It was reported by the crew to the PSCO, that the leak first occurred and was temporarily repaired in January 2008. SOLAS 2004 (cons) Chapter I Reg. 11, 17a,c.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Resolution: The temporarily repaired sea valve was inspected and slight leakage was found by Class NK surveyor. The valve was reinforced and repaired by "Devcon" with the attending NK surveyors satisfaction.
Engineering › Bilge Water Management System › Eductor
Issued 17 October 2008
Resolved
Bilge eductor line from direct bilge suction to overboard has a temporary repair that is leaking. SOLAS 2004 (cons) Chapter I Reg. 11 17a,c.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Resolution: The bilge eductor was examined and local corrosion was found by Class NK surveyor. The leakage point was repaired by "Devcon" and spot welding by the crew and the temporary repair was approved by NK surveyor.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 27 March 2006
Resolved
Inspection of provisional stores concluded an inadequate supply of provisions for a 20 man crew. This is vsl's 3rd consecutive U.S. port with inadequate provisions. Vsl required to summit invoice for full purchase of provisions to Coast Guard prior to departure from port.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2006
Resolution: Received full purchase invoice for provisions from IL Dong Imports & Marine Supply Co.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 27 March 2006
Resolved
Vsl's Garbage log indicated disposal of 1.0m3 CAT 2 products being disposed of in the Wider Caribbean Region Special Area. Recommend inspect and review vsl's Garbage log after 30 days to satisfaction of Coast Guard Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 April 2006
Resolved 4 August 2009
Resolution: The attending PSCO reviewed and verified the new management of the vessel was logging all required information accurately in the vessel Garbage record book satisfying outstanding requirement.