Records from 2016 to 2026. Most recent: inspection, 8 July 2026.
Inspection history · 19
8 July 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8433392
26 March 2026
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8334525
16 July 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8182629
30 April 2025
In-Service Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8126919
18 July 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7959551
21 June 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7720855
19 April 2023
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7671740
21 April 2022
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7435491
21 October 2021
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7343963
8 June 2021
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7220021
21 April 2021
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7179523
9 June 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6972587
9 April 2019
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6659129
9 April 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6659133
29 November 2018
Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6596625
23 May 2018
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6420567
8 May 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6408579
28 April 2017
COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6134651
18 April 2016
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5942199
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 18 July 2024
Resolved
Provide proof of enrollement in CG approved drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2024
Resolution: provided
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 July 2024
Resolved
Ensure IBA is serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2024
Resolution: serviced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 July 2024
Resolved
Prove proper operation of vapor detector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2024
Resolution: test sat
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 July 2024
Resolved
Conduct satisfactory drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2024
Resolution: drills satisfactory conducted
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 21 June 2023
Resolved
Vessel must have valid FCC Station License.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 18 July 2024
Resolution: renewed
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 21 June 2023
Resolved
Vessel must have valid FCC Safety Radiotelephony Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 18 July 2024
Resolution: renewed
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 June 2023
Resolved
Vessel must have two (02) portable lights. One at the operating station and one at the aft part of the cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2023
Resolved 27 September 2023
Resolution: vsl owner stated 02 portable lights are on the vessel
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 June 2023
Resolved
Ensure all crew has completed pre-employment drug testing (with a negative result) and is enrolled in a CG approved drug testing program prior to serving in a safety sensitive position.
Action required: 10 - Deficiency Rectified
Resolved 21 June 2023
Resolution: Educated new owner on requirements.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 May 2019
Resolved
Bilge high level alarm is not operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2019
Resolved 13 June 2019
Resolution: Tested satisfactorily.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 23 May 2018
Resolved
Fire extinguisher located in passenger space, gauge was found in the red. Replace or service fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 28 May 2019
Resolution: All fire extinguishers were serviced and good.
Navigation › Piloting/Steering › Marine Charts
Issued 23 May 2018
Resolved
Vessel required navigation charts for the area operated in.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 28 May 2019
Documentation › Markings/Placards › Garbage Placard
Issued 23 May 2018
Resolved
Vessels garbage placard is outdated. Update with current placard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2018
Resolved 13 June 2019
Resolution: Provided owner with an updated placard.
Construction/Loadline › Structures › End Bulkhead
Issued 8 May 2018
Resolved
Cracks found located on vessels transom, owner to fill cracks and make permanent repairs after operating season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 28 May 2019