MAURY USCG vessel records Sign in
← All vessels

OFFSHORE ACCOUNT

OFFSHORE ACCOUNT is a 2002 commercial fishing vessel. The Coast Guard has recorded 22 inspections since 2002, most recently in March 2022, along with 28 deficiencies and 1 operational control.

Records from 2002 to 2022. Most recent: inspection, 3 March 2022.

Built
2002
Last inspected
3 March 2022
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

513067
Flag
UNITED STATES
366855520, 367652970 (licence lapsed)
Maury page id
psix-513067

Inspections, by type

…with no type recorded4
Years with a record 17 calendar years (2002–2022)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)35.7 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK INDUSTRIES INC · SEBRING, FL, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLITTLE RIVER, SC
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH7929MMSI 367652970 · expired · compulsorily equipped · granted 13 January 2015, cancelled 15 March 2025 · licensed under a name not among this hull’s recorded names (not shown)
WDA8545MMSI 366855520 · expired · compulsorily equipped · granted 1 June 2002, cancelled 4 August 2012 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 22

3 March 2022 Type not recorded
No type recorded · USCGC POMPANO (WPB 87339) · USCG East District (CGD-E) · Activity 7405772
10 July 2021 Type not recorded
No type recorded · USCGC RAYMOND EVANS (WPC-1110) · USCG Southeast District (CGD-SE) · Activity 7296082
2 May 2021 Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 7202160
6 April 2021 Type not recorded
No type recorded · USCGC POMPANO (WPB 87339) · USCG East District (CGD-E) · Activity 7174404
19 June 2019 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6719170
12 June 2018 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6442155
23 May 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6416833
12 May 2017 COI Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6144799
3 November 2016 Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6034649
11 May 2016 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5875236
23 May 2014 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4866096
2 May 2012 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4300505
8 September 2010 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3857897
22 July 2009 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3544309
15 May 2008 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3214277
8 May 2007 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2922011
9 August 2006 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2735099
18 July 2005 Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2430833
1 July 2004 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2156564
20 June 2003 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1825851
23 May 2002 Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1620005
21 May 2002 Simplified Stability Test
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1620455

Deficiency record · 28

Engineering › Steering Gear System › Bracket/Clamp
Issued 23 May 2018 Resolved
Found wood support for the steering system to have excessive rot. Renew wood support system for the steering system.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 June 2018
Resolved 12 June 2018
Resolution: Inspected and tested satisfactory repairs.
Communications › Radio Communications › EPIRB
Issued 12 May 2017 Resolved
Renew hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2017
Resolved 22 May 2017
Resolution: EPIRB hydro static release renewed.
Communications › Visual Communication › Red Warning Signal
Issued 12 May 2017 Resolved
Provide 6 additional hand red flares to meet rout requirements.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2017
Resolved 22 May 2017
Resolution: Flares provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 12 May 2017 Resolved
Remount Fireboy cylinder on aft engine room bulkhead as it appears to be sliding downward in bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 23 May 2018
Resolution: Cleared with Annual Inspection.
Engineering › Steering Gear System › Rudder Stock
Issued 12 May 2017 Resolved
Adjust/tighted loose packing nut and backer for portside rudder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 23 May 2018
Resolution: Cleared with Annual Inspection.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 3 November 2016 Resolved
Renew port and starboard cutlass bearings at the struts. Wear is beyond acceptable wear.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2016
Resolved 22 May 2017
Resolution: Bearings renewed. All sat.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 May 2016 Resolved
There was no Great Lakes Radio Agreement on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2016
Resolved 22 May 2017
Resolution: Provide valid Great Lakes Radio Agreement
Communications › Radio Communications › EPIRB
Issued 11 May 2016 Resolved
The EPIRB's battery expired in 2014.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 22 May 2017
Resolution: Renew EPIRB Battery.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 May 2016 Resolved
The water light's battery was expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 22 May 2017
Resolution: Battery renewed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 May 2016 Resolved
The all round navigation light was in-operative
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 22 May 2017
Resolution: Prove proper operation of the allround navigation lights.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 2 May 2012 Resolved
Issued requirement to mount fire extinguisher.
Condition: Improper Installation
Due 31 May 2012
Resolved 6 March 2013
Resolution: Cleared def per e mail from owner.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 May 2012 Resolved
FCC Great Lakes Certificate not on board. Issued requirement to provide document on board.
Due 31 May 2012
Resolved 30 May 2012
Resolution: Completed requirement.
Lifesaving › Hand Flares › Expired
Issued 2 May 2012 Resolved
Issued requirement to renew 6 hand flares.
Due 31 May 2012
Resolved 30 May 2012
Resolution: Flares renewed
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 2 May 2012 Resolved
Issued requirement to renew batteries in life jacket lights.
Due 31 May 2012
Resolved 6 March 2013
Resolution: Cleared def per e mail from owner.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 2 May 2012 Resolved
Stern light on mast extinguished, lights obstructed by life float & radar. Issued requirement to install longer/taller mast.
Due 31 May 2012
Resolved 6 March 2013
Resolution: Cleared def per e mail & photo from owner.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 September 2010 Resolved
Vessel operating outside valid reinspection dates
Action required: 705 - Other - as specified
Due 8 September 2010
Resolved 8 September 2010
Electrical › Lighting (service) › Lighting Feeder
Issued 22 July 2009 Resolved
Remove dead ended conductors in electrical panel.
Condition: Improper Installation
Due 3 August 2009
Resolved 17 August 2009
Resolution: Condutors removed per telecon 8/17.
Communications › Radio Communications › EPIRB
Issued 22 July 2009 Resolved
Renew battery & hydrostatic release. Vsl restricted to within 3 NM of shore.
Condition: Improper/Lack of Maintenance
Due 3 August 2009
Resolved 12 August 2009
Resolution: Owner faxed copy of work order for renewal of battery and hydrostatic release.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 22 July 2009 Resolved
COI required 2 B-II extinguishers, only one was on board. Issued requirement to add another B-II extinguisher.
Due 3 August 2009
Resolved 8 September 2010
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 July 2009 Resolved
Renew reflective tape on ring buoy.
Condition: Improper/Lack of Maintenance
Due 3 August 2009
Resolved 17 August 2009
Resolution: Reflected tape has been installed per telecon on 8/17.
Engineering › Bilge Water Management System › Not Operational
Issued 22 July 2009 Resolved
Aft bilge high level alarm inoperable. Repair as required.
Condition: Improper/Lack of Maintenance
Due 3 August 2009
Resolved 17 August 2009
Resolution: Loose connection corrected per telecon on 8/17.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 22 July 2009 Resolved
Install overcurrent protection in conductor aconnected to positive terminal on battery.
Condition: Improper Installation
Due 3 August 2009
Resolved 17 August 2009
Resolution: In line fuse installed per telecon on 8/17.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 July 2005 Resolved
Provide new Coast Pilot and Light List.
Due 27 July 2005
Resolved 27 July 2005
Resolution: New Coast Pilot and Light List on board.
Communications › Radio Communications › EPIRB
Issued 20 July 2005 Resolved
Replace/ Rrepair EPIRB and hydrostatic release.
Due 27 July 2005
Resolved 27 July 2005
Resolution: New EPIRB antena and Hydrostatic release.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 20 July 2005 Resolved
Replace batteries in all life jacket lights.
Due 27 July 2005
Resolved 27 July 2005
Resolution: All batteries have been replaced.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 July 2005 Resolved
Provide one portable flash light.
Due 27 July 2005
Resolved 27 July 2005
Resolution: Provided one portable light.
Fire Fighting › Fire Bucket › Stenciling
Issued 1 July 2004 Resolved
Stencil fire buckets with vessel name.
Condition: Improper/Lack of Maintenance
Due 30 July 2004
Resolved 30 July 2004
Engineering › Bilge Water Management System › Pump
Issued 1 July 2004 Resolved
Provide a portable Bilge pump for vessel.
Condition: Improper/Lack of Maintenance
Due 30 July 2004
Resolved 30 July 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.