Records from 1981 to 2007. Most recent: inspection, 18 September 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 57
18 September 2007
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3067582
29 January 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2863394
10 August 2006
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2743858
12 October 2005
Damage Survey · Re-Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2522695
12 September 2005
Drydock Extension
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2490360
10 August 2005
In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2458492
3 August 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2471921
22 March 2005
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2316531
9 December 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2256123
5 September 2003
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1897550
6 January 2003
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1726547
14 December 2001
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1476110
9 November 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403494
23 January 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399530
15 February 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817408
2 December 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452595
9 December 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468030
5 December 1997
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443945
26 November 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453303
28 May 1996
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1085118
20 May 1996
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1084069
10 April 1996
COI Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1452141
29 March 1996
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1079453
29 February 1996
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 885804
13 April 1995
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 840846
31 March 1995
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 834913
1 March 1995
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1166140
16 June 1994
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1452021
5 April 1994
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 857460
4 March 1994
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1164878
17 March 1993
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1145635
5 March 1993
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1152372
9 March 1992
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1008856
6 March 1992
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1318064
23 April 1991
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 923787
11 April 1991
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1220359
4 May 1990
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1224907
26 April 1990
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1232139
28 March 1990
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1288382
10 May 1989
Administrative
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1196922
25 April 1989
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1339029
17 March 1989
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1210128
16 March 1989
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 898539
14 July 1988
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1034248
24 June 1988
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 900568
25 April 1988
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1341270
21 July 1987
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1025568
4 May 1987
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1017980
23 April 1987
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1322499
1 April 1987
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1009083
28 May 1986
Damage Survey
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 988938
25 April 1986
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1304403
8 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983766
29 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971817
17 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964583
18 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970633
20 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972163
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 September 2007
No resolution recorded
Provide original COD onboard vsl.
Action required: 705 - Other - as specified
Communications › Radio Communications › EPIRB
Issued 18 September 2007
Resolved
Affix EPIRB registration sticker directly to EPIRB unit.
Due 18 October 2007
Resolved 18 September 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 18 September 2007
Resolved
Install a light above each bunk in crews' quarters.
Due 18 October 2007
Resolved 18 September 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 September 2007
Resolved
Install an operable e-light facing towards emergency escape hatch in generator room.
Due 18 October 2007
Resolved 18 September 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 12 October 2005
Resolved
Provide rubber mat for generator control panel.
Condition: Unknown
Due 28 December 2005
Resolved 17 January 2006
Resolution: Rubber mat provided.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 12 October 2005
Resolved
Provide breaker bar to prevent simultaneous operation of both generators to supply power.
Condition: Improper Installation
Due 28 December 2005
Resolved 17 January 2006
Resolution: Breaker bar provided by owner/operator.
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 October 2005
Resolved
Provide proper battery box for generator start batteries.
Condition: Improper Installation
Due 28 December 2005
Resolved 17 January 2006
Resolution: Battery box with cover provided.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 12 October 2005
Resolved
Plug holes in stbd generator housing.
Condition: Improper Installation
Due 28 December 2005
Resolved 17 January 2006
Resolution: Holes sealed using metal plates.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 12 October 2005
Resolved
Replace power available lights on generator control panel.
Condition: Improper/Lack of Maintenance
Due 28 December 2005
Resolved 17 January 2006
Resolution: Light replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 October 2005
Resolved
Provide junction box for loose wiring on fwd e/r bulkhead.
Condition: Improper Installation
Due 28 December 2005
Resolved 17 January 2006
Resolution: Repair completed.
Lifesaving › Lifefloat › Serviceable
Issued 12 October 2005
Resolved
Replace deteriorated 6-man lifefloat.
Condition: Improper/Lack of Maintenance
Due 28 December 2005
Resolved 17 January 2006
Resolution: New lifefloat provided.
Construction/Loadline › Structures › Scuttle
Issued 12 October 2005
Resolved
Mark emergency escape hatches on weather decks.
Condition: Unknown
Due 28 December 2005
Resolved 17 January 2006
Resolution: Hatched marked ''Emergency Exit, Keep clear''.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 12 October 2005
Resolved
Replace missing bolts in enhaust hangers.
Condition: Improper/Lack of Maintenance
Due 28 December 2005
Resolved 17 January 2006
Resolution: Repair completed.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 October 2005
Resolved
Clean port side engineroom exhaust fan.
Condition: Improper/Lack of Maintenance
Due 28 December 2005
Resolved 17 January 2006
Resolution: Fan cleaned.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 12 October 2005
Resolved
Provide FCC Radio Operator Permit.
Condition: Unknown
Due 28 December 2005
Resolved 10 August 2006
Navigation › Piloting/Steering › Marine Charts
Issued 12 October 2005
Resolved
Update charts to local notice to mariners.
Condition: Improper/Lack of Maintenance
Due 28 December 2005
Resolved 10 August 2006
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 August 2005
Resolved
Provide draft marks on vessel hull.
Action required: 705 - Other - as specified
Due 10 August 2005
Resolved 10 August 2005
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 August 2005
Resolved
Provide vessel name on stern.
Action required: 705 - Other - as specified
Due 10 August 2005
Resolved 10 August 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 3 January 2005
Resolved
Provide Emergency stops that secure main engiens in all operating conditions.
Action required: 705 - Other - as specified
Due 13 January 2005
Resolved 22 March 2005
Resolution: Demonstrated emergency main engine shut downs from primary operating station.
Electrical › Lighting (service)
Issued 5 September 2003
Resolved
RENEW ELECTRIC WIRE WEATHER TIGHT COUPLING ON BRIDGE TOP. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 11 September 2003
Lifesaving › Hand Flares › Quantity
Issued 5 September 2003
Resolved
PROVIDE ONE ORANGE FLARE PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2003
Resolved 11 September 2003
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 5 September 2003
Resolved
PROVIDE AND POST LIFE JACKET DONNING PLACARD PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2003
Resolved 11 September 2003
Electrical › Lighting (service)
Issued 5 September 2003
Resolved
PROVIDE AND INSTALL COVER ON RANGE HOOD LIGHT AND FAN. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 5 September 2003
Resolved
INSTALL RACK LIGHTS ON BERTHING RACKS.
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 11 September 2003
Construction/Loadline › Structures
Issued 5 September 2003
Resolved
ADJUST DOGS ON ESCAPE HATCH. LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Construction/Loadline › Structures
Issued 5 September 2003
Resolved
ADJUST ARMS ON ENGINE ROOM HATCH. LEGACY COMPONENT DESC: Machinery Space Opening
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Fire Fighting › Ventilation Systems › Fans
Issued 5 September 2003
Resolved
DEMONSTRATE PROPER OPERATION OF ENGINE ROOM EXHAUST FANS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 11 September 2003
Engineering › Fuel Oil Service System › Hose
Issued 5 September 2003
Resolved
PROVIDE AND INSTALL HOSES ON PORT AND STARBOARD GENERATOR AND STARBOARD MAIN ENGINE MEETING J1942 REGULATIONS.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2003
Resolved 11 September 2003
Electrical › Electrical Distribution System (service)
Issued 5 September 2003
Resolved
INSTALL COVER PLATE ON MAIN SWITCHBOARD IN ENGINE ROOM. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Fire Fighting › Means of Escape
Issued 5 September 2003
Resolved
STENCIL EMERGENCY EXIT ON DOOR IN GALLEY LEGACY COMPONENT DESC: Escape Route Signs
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Electrical › Electrical Distribution System (service)
Issued 5 September 2003
Resolved
STENCIL ALL ELECTRICAL MOTOR CONTROLLING SWITCHES IN ENGINE ROOM. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Accommodation/Occupational Safety › Potable Water System
Issued 5 September 2003
Resolved
REPAIR FRESH WATER PUMP PRIOR TO SAILING. LEGACY COMPONENT DESC: FRESH WATER PUMP
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2003
Resolved 11 September 2003
Communications › Alarms/Indicators
Issued 5 September 2003
Resolved
RENEW AND REPLACE BILGE SWITCHES. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2003
Resolved 11 September 2003
Engineering › Fuel Oil Service System
Issued 5 September 2003
Resolved
INSTALL CHAFFING GEAR ON ALL ENGINES AS DISCUSSED. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Deck/Cargo › Vapor Control Systems
Issued 5 September 2003
Resolved
STENCIL ALL DECK VALVES LEGACY COMPONENT DESC: VALVE MARKING
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Deck/Cargo › Vapor Control Systems
Issued 5 September 2003
Resolved
PROVIDE AND MOUNT PLUGS FOR ALL DECK VENTS. LEGACY COMPONENT DESC: VENT PLUGS
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 5 September 2003
Construction/Loadline › Structures
Issued 5 September 2003
Resolved
INSTALL CHAIN ON FORWARD VOID HATCH. LEGACY COMPONENT DESC: Scuttle
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Engineering › Steering Gear System
Issued 5 September 2003
Resolved
REMOVE OR REPAIR RUDDER ANGLE INDICATOR TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Communications › Alarms/Indicators
Issued 5 September 2003
Resolved
REPAIR OR REPLACE CENTER ENGINE RPM GAUGE PRIOR TO SAILING. LEGACY COMPONENT DESC: Propeller Revolutions Rate Indicator
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2003
Resolved 11 September 2003
Documentation › Certificates/Documents
Issued 5 September 2003
Resolved
PROVIDE BRIDGE-TO-BRIDGE CERTIFICATE. LEGACY COMPONENT DESC: BRIDGE TO BRIDGE CERTIFICATE.
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Personnel › Certificates/Documents/Licenses
Issued 5 September 2003
Resolved
PROVIDE FCC OPERATOR PERMIT . LEGACY COMPONENT DESC: License, Operator
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 15 September 2003
Deck/Cargo › Holds/Tanks
Issued 5 September 2003
Resolved
COMPLETE ALL REPAIRS FROM HULL EXAM PRIOR TO SAILING. LEGACY COMPONENT DESC: HULL EXAM REPAIRS
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2003
Resolved 11 September 2003
Construction/Loadline › Structures
Issued 9 January 2003
Resolved
MAKE REPAIR TO CRACKED WELD OVER PORT SIDE EXHAUST.
Due 23 January 2003
Resolved 14 January 2003
Resolution: Corrected
Construction/Loadline › Structures
Issued 9 January 2003
Resolved
MAKE REPAIRS TO CRACKED WELDS ON PORT AND STBD LAZERETTE STERN CORNERS.
Due 23 January 2003
Resolved 6 February 2003
Resolution: Satisfactory repairs made.
Stability › Watertight Integrity
Issued 9 January 2003
Resolved
PROVIDE STUFFING TO WATERTIGHT BULKHEAD PENETRATION PORT SIDE E/R.
Due 23 January 2003
Resolved 14 January 2003
Resolution: Corrected
Engineering › Bilge Water Management System
Issued 9 January 2003
Resolved
MAKE REPAIRS TO BILGE SUCTION LINE AT TONNAGE BULKHEAD.
Due 23 January 2003
Resolved 14 January 2003
Resolution: Repaired to the satisfaction of the attending inspector.
Accommodation/Occupational Safety
Issued 9 January 2003
Resolved
MAKE REPAIRS TO STBD SIDE DECK RAILING AT GANGWAY OPENING.
Due 23 January 2003
Resolved 14 January 2003
Resolution: Rewelded to the satisfaction of the attending inspector.
Construction/Loadline › Hull
Issued 9 January 2003
Resolved
MAKE PROPER REPAIR TO PORT SIDE HULL FWD.
Due 23 January 2003
Resolved 16 January 2003
Resolution: Witnessed satisfactory test of hull insert. High pressure water was used to verify weld.
Lifesaving
Issued 7 January 2002
Resolved
ARRANGE LIFEFLOATS IN A FLOAT FREE DESIGN PRIOR TO SAILING. LEGACY COMPONENT DESC: LIFEFLOATS
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 January 2002
Resolved 7 January 2002
Communications › Audible Communications
Issued 7 January 2002
Resolved
INSTALL A PUBLIC ADDRESS SYSTEM THROUGHOUT VESSEL.
Condition: Unknown
Due 14 January 2002
Resolved 10 September 2003
Resolution: INSTALLED PUBLIC ADDRESS SYSTEM THROUGHOUT VESSEL.
Engineering
Issued 7 January 2002
Resolved
MAIN ENGINE GAUGES NOT WORKING AT PILOT HOUSE LEGACY COMPONENT DESC: GAUGES
Condition: Improper/Lack of Maintenance
Due 7 January 2002
Resolved 7 January 2002
Electrical
Issued 7 January 2002
Resolved
REPAIR HIGH BILGE ALARM IN RUDDER ROOM PRIOR TO SAILING. LEGACY COMPONENT DESC: HIGH BILGE ALARM
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 January 2002
Resolved 7 January 2002
Accommodation/Occupational Safety
Issued 7 January 2002
Resolved
STENCIL ALL WATERTIGHT DOORS "KEEP CLOSED WHILE UNDERWAY" PRIOR TO SAILING LEGACY COMPONENT DESC: STENCILING
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 January 2002
Resolved 7 January 2002
Fire Fighting › Fire Hoses › Material
Issued 7 January 2002
Resolved
CONDEMENED ONE FIRE HOSE. REPLACE PRIOR TO SAILING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 January 2002
Resolved 7 January 2002
Electrical › Electrical Distribution System (service)
Issued 7 January 2002
Resolved
BULBS NOT INSTALLED IN MAIN SWITHCBOARD. LEGACY COMPONENT DESC: Switchboard
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 January 2002
Resolved 7 January 2002
Documentation
Issued 23 January 2001
Resolved
PROVIDE PROPER STABILITY PERMITTING OPERATION FURTHER THAN 20NM FROM SHORE IN THE OIL AND GAS INDUSTRY.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Construction/Loadline
Issued 23 January 2001
Resolved
PROVIDE HIGH WATER LEVEL BILGE ALARM IN THE VOID SPACE BELOW THE FORWARD PASSENGER COMPARTMENT (IAW 46 CFR 182.530) TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Electrical
Issued 23 January 2001
Resolved
PROVIDE 01 ADDITIONAL EMERGENCY EGRESS LIGHT IN THE VICINITY OF THE AFT ENGINE ROOM BULKHEAD TO ILLUMINATE THE PATH OF ESCAPE. INSTALL LIGHTING IAW46 CFR 183.432 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Construction/Loadline
Issued 2 December 1999
Resolved
PROPERLY INSTALL CHECK VALVES IN ALL BILGE SUCTION LINES, IAW 46 CFR _x001C_ 182.25-5(C) TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Engineering
Issued 29 February 1996
Resolved
REPLACE FRAYED ELECTRICAL CABLE TO PORT ENGINE.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Engineering
Issued 29 February 1996
Resolved
REPAIR MECHANICAL TACHOMETER ON STARBOARD ENGINE.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Construction/Loadline
Issued 29 February 1996
Resolved
PROVIDE NEW (HARD RUBBER) GASKET FOR AFT HEAD EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Electrical
Issued 29 February 1996
Resolved
HARDWIRE THE PILOT HOUSE FLOODLIGHTS.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Navigation
Issued 29 February 1996
Resolved
REPAIR PORT AFT RADIO ANTENNA BASE.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Navigation
Issued 29 February 1996
Resolved
REPLACE PORT, STARBOARD AND STERN RUNNING LIGHTS LENSES.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Electrical
Issued 29 February 1996
Resolved
IDENTIFY CIRCUIT BREAKERS IN ELECTRICAL DISTRIBUTION PANELS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Electrical
Issued 29 February 1996
Resolved
REMOVE OR CAP DEAD END ELECTRICAL CABLE IN THE MSD COMPARTMENT.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Electrical
Issued 29 February 1996
Resolved
PROVIDE COVER FOR ELECTRICAL RECEPTABLE OVER GALLEY SINK THAT COMPLETELY COVERS THE OUTLET OPENING.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Documentation
Issued 29 February 1996
Resolved
PROVIDE INSPECTOR WITH COPY OF WRITTEN DRUG POLICY PRIOR TO 07MAR96.
Condition: Unknown
Due 7 March 1996
Resolved 7 March 1996
Electrical
Issued 29 February 1996
Resolved
REMOVE DEAD END WIRES FROM BENEATH THE PILOT HOUSE CONSOLE AND REINSTALL LOOSE CONSOLE GAUGE LIGHT.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Engineering
Issued 1 March 1995
Resolved
REPAIR/REPLACE STBD MAIN ENGINE GEAR OIL PRESSURE GUAGE.
Condition: Unknown
Due 1 March 1995
Resolved 1 March 1995
Navigation
Issued 1 March 1995
Resolved
REPAIR KODEN CHROMASCOPE CVS-88 FATHOMETER TRANSDUCER AND PROVE PROPER OPERATION TO USCG MARINE INSPECTOR. REPAIR WHEN VESSEL HAULED OUT FOR ITS ANNUAL PRESSURE WASH.
Condition: Unknown
Due 1 March 1995
Resolved 1 March 1995
Lifesaving
Issued 4 March 1994
Resolved
PROVIDE COMPLETE FIRST AID KIT.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Electrical
Issued 4 March 1994
Resolved
PROVIDE METAL WIRE TIES FOR OVERHEAD CABLE RUN IN LAZARETTE.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Fire Fighting
Issued 4 March 1994
Resolved
MARK FIRE AXE WITH VESSEL'S NAME.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Construction/Loadline
Issued 4 March 1994
Resolved
REMOVE ENGINE ROOM/LAZARETTE QAWTD AND REPLACE WITH BULKHEAD TO COMPLY WITHG-MVI POLICY LETTER 22-89.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Engineering
Issued 4 March 1994
Resolved
PROVIDE APPROVED FLAME SCREEN FOR PORT FUEL TANK VENT.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Fire Fighting
Issued 4 March 1994
Resolved
PROVIDE KEEPER CHAINS FOR FOG SPUDS ON BOTH FIRE NOZZLES.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Navigation
Issued 4 March 1994
Resolved
REPLACE LENSES OF ALL FOUR NAVIGATIONAL RUNNING LIGHTS.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Construction/Loadline
Issued 4 March 1994
Resolved
PROVIDE MACHINERY GUARD FOR BELT TO JABSCO PUMP.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Electrical
Issued 4 March 1994
Resolved
PROVIDE DIELECTRIC MAT IN FRONT OF GENERATOR CONTROL PANEL.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Construction/Loadline
Issued 4 March 1994
Resolved
RENEW GASKET OF FORWARD CABIN HATCH.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Construction/Loadline
Issued 4 March 1994
Resolved
REWORK AND LUBRICATE DOGS TO EMERGENCY ESCAPE HATCH IN WOMEN'S HEAD AND REPLACE ONE MISSING INTERIOR DOG HANDLE.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Accommodation/Occupational Safety
Issued 26 April 1990
Resolved
PROVIDE VENT TO EXTERIOR OF VESSEL FOR THE MSD TANK FORWARD TO BE COMPLETED PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Accommodation/Occupational Safety
Issued 26 April 1990
Resolved
SUBMIT DRAWINGS FOR THE TOILETS AND HOLDING TANKS.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Electrical
Issued 26 April 1990
Resolved
MAKE PROPER ELECTRICAL CONNECTION TO THE STBD MAIN GENERATOR JUNCTION BOX TO BEW COMPLETED PRIOR TO USING GENERATOR
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Navigation
Issued 16 March 1989
Resolved
REPAIR OR RENEW STARBOARD RUDDER
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Accommodation/Occupational Safety
Issued 25 April 1988
Resolved
REPLACE MISSING FAN BLADE GUARDS ON A/C UNIT AFT OF WHEELHOUSE.
Condition: Unknown
Due 25 April 1988
Resolved 25 April 1988
Construction/Loadline
Issued 25 April 1988
Resolved
MAKE OPERATIONAL REACH ROD TO FORE PEAK BILGE SUCTION LINE.
Condition: Unknown
Due 25 April 1988
Resolved 25 April 1988
Electrical
Issued 23 April 1987
Resolved
PROVIDE STUFFING TUBE THROUGH DECK FOR REEL CABLE.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Electrical
Issued 23 April 1987
Resolved
PROVIDE COVERS FOR REEL OUTLETS.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Electrical
Issued 23 April 1987
Resolved
REPAIR STARBOARD GENERATOR OVERSPEED TRIP AND ALARM CIRCUIT.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Construction/Loadline
Issued 23 April 1987
Resolved
MAKE OPERATION FOREPEAK TANK REACH ROD
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987