07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 March 2026
Resolved
...the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. MI found the port fire pump gauge is crushed and incapable of providing readings.
46 CFR 181.300(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2026
Resolved 6 March 2026
Resolution: Recieved satisfactory photos of new gauges installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 3 March 2026
Resolved
A hatch cover must: Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. MI found the port engine room access panel is missing 8 bolts.
46 CFR 179.360(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2026
Resolved 6 March 2026
Resolution: Received video of bolt replacement
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. MI found dead end wire in port void above the fresh water tank.
46 CFR 183.200(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2026
Resolved 6 March 2026
Resolution: Recieved photo of dead end wire capped.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 March 2026
Resolved
Every portable fire extinguisher must be supplied with a suitable bracket which will hold the extinguisher securely in its stowage location on vessels or boats, and which is arranged to provide quick and positive release of the extinguisher for immediate use. MI found multiple extinguisher brackets wasted.
46 CFR 162.028-3(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2026
Resolved 30 March 2026
Resolution: Received satisfactory photos of bracket replacement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 March 2026
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. MI found port aft window cracked.
46 CFR 177.1020
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2026
Resolved 1 April 2026
Resolution: Received satisfactory photos of window replacement
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 March 2026
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI found port engine room deck plate is unsupported, resulting in unstable surface.
46 CFR 176.830
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2026
Resolved 30 March 2026
Resolution: Received satisfactory photo and video of the repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2026
Resolved
Electrical equipment exposed to the weather must be watertight. MI found two exterior lights not watertight.
46 CFR 183.210(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2026
Resolved 6 March 2026
Resolution: Recieved photos of terminal hole capped and loose light removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 March 2026
Resolved
All electrical equipment and circuits must be clearly marked and identified. MI found electrical panels in the engine room with missing labels.
46 CFR 183.220(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2026
Resolved 6 March 2026
Resolution: Recieved photo of electrical panel with updated labels.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2025
Resolved
Flexible nonmetallic hose may be used in lube oil, fuel oil and fluid power systems, subject to the following requirements: For the purpose of flexibility only, flexible hose installed in lengths of not more than 30 inches and subject to pressures of not more than 35 kPa. Observed that the port generator fuel return line consisted of flex hose for entire length. Install hard piping to the satisfaction of the MI.
46 CFR 182.720(e)(3)(v)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 2 May 2025
Resolution: Received photos of installed fuel lines and email from technician stating new non-metallic flex hose meets J1942 standards.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 16 April 2025
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Observed deck hose line in starboard engine room leaking. Rectify leak to the satisfaction of the MI.
46 CFR 176.800(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2025
Resolved 29 April 2025
Resolution: Received satisfactory picture of new line.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 April 2025
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Observed that the bilge alarm float switches were not adequately mounted in voids #2 and #3, port and starboard. Securely mount float switches to the satisfaction of the MI.
46 CFR 183.220(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 29 April 2025
Resolution: Received satisfactory pictures of mounted bilge alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Observed that the child life jackets were not separated from adult life jackets. Stow life jackets separately to the satisfaction of MI.
46 CFR 180.78(a)(5)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2025
Resolved 29 April 2025
Resolution: Received satisfactory picture of barrier separating life jackets.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2025
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Observed that the FCC Safety Radiotelephone Certificate was expired. Provide a current certificate to the satisfaction of the MI.
47 CFR 80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 29 April 2025
Resolution: Received satisfactory copy of cert.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 April 2025
Resolved
All metallic enclosures and frames of electrical equipment must be permanently grounded to the hull on a metallic vessel. Ground wires found detached on both main diesel engines. Reattach to satisfaction of MI.
46 CFR 183.372
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 29 April 2025
Resolution: Received satisfactory picture of installed ground wire.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 April 2025
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Bilge alarm junction box not properly mounted. Mount junction box to the satisfaction of MI.
46 CFR 183.220(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 29 April 2025
Resolution: Received satisfactory picture of mounted junction box.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 April 2025
Resolved
Machinery spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Forward bulkhead of port engine room not vapor tight. Make vapor tight to the satisfaction of the MI.
46 CFR 177.405(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 29 April 2025
Resolution: Received satisfactory picture of installed cap.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 April 2025
Resolved
Piping conveying vapor, gas, or liquid, the temperature of which exceeds 150 °F, must be suitably insulated where necessary to prevent injuries. Exhaust lagging not adequate on port main engine. Install sufficient-sized lagging to satisfaction of MI.
46 CFR 177.970
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 29 April 2025
Resolution: Received satisfactory picture of installed lagging.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 April 2025
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Metal cable support in overhead of port engine room, outboard aft, found detached from frame. Reinstall support.
46 CFR 183.340(b)(4)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 29 April 2025
Resolution: Received satisfactory picture of installed support.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 April 2025
Resolved
The owner... shall have ready for inspections all accessible parts of the hull, the watertight bulkheads, and weather decks. Excess water found in forward voids, port and starboard. Pump all water out.
46 CFR 176.802(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 29 April 2025
Resolution: Received satisfactory picture of dry bow sections.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. 02 dead end wires found coming out of multi-cable transit in port engine room.
46 CFR 183.200(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 29 April 2025
Resolution: Received satisfactory picture of removed wires.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 March 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2025
Resolution: Verified plan review info and install for repower.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel was due for inspection no later than 24 May. The vessel is unable to carry passengers until successful completion of an annual inspection, currently scheduled on 28MAY2024.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2024
Resolution: Vessel completed underway portion of annual inspection
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 28 May 2024
Resolved
Each survival craft must be: stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Hydrostatic connection for IBA was installed improperly. 46 CFR 180.130(a)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2024
Resolution: Vessel corrected HRU installation on the spot
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2024
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may … require the vessel … to effect permanent repairs. The forward STBD forepeak had cracked weld on second frame / top longitudinal frame meeting point. Make permanent repairs to the satisfaction of the marine inspector.
46 CFR 176.600
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 July 2024
Resolution: Weld repairs made to affected areas.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 May 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel’s consortium enrollment for the Drug and Alcohol program was expired. 46 CFR 16.230(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2024
Resolution: Verified consortium enrollment with proper daters
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 28 May 2024
Resolved
Each device must be – free of design defects that would allow toxic substances to escape to the interior of the vessel. MI’s observed leaking sewage dripping from port and starboard tank connections into the bilge. 33 CFR 159.95 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2024
Resolution: Verified sewage leak resolved
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 28 May 2024
Resolved
Each marine sanitation device must meet all other safety requirements of the regulations applicable to the type of vessel for which it is certified. Portside #2 void sewage piping is being supported by zip ties. Vessel to install permanent supports to the satisfaction of the marine inspector. 33 CFR 159.95(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2024
Resolution: Verified installation of permanent supports
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel was due for inspection no later than 24 May. The vessel is unable to carry passengers until successful completion of an annual inspection, currently scheduled on 28MAY2024.
46 CFR 176.500 (b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2025
Resolution: Completed annual inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2024
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel experienced a small fire in the engine room, resulting in melted wires and engine fluctuations. Provide root cause, determine extent of damages, and undergo visual inspection to the satisfaction of the attending MI.
46 CFR 176.840
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 May 2024
Resolution: Vessel identified root cause and attending MI verified replacement of wires and satisfactory operation of engine.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 3 November 2023
Resolved
Each marine employer shall ensure that random drug tests conducted under this part are unannounced and that the dates for administering random tests are spread reasonably throughout the calendar year. Company has designated a vessel Master to serve as the Company Designated Employer Representative (DER). This arrangement does not allow for a random selection of crewmembers as intended by this regulation. Company to assign responsibilities of DER to an employee that is not one of the members that shall be randomly drug tested as required by this regulation.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2023
Resolution: Received notification that company has elected a new DER. Uploaded information on new DER to Special Note. DER has received supervisor level training and all employees have been trained in EAP.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 May 2023
Resolved
Piping, valves, and fittings in a fire main system must comply with subpart G, part 182, of this chapter. Starboard fire main pump has a leaking seal that requires replacement and the port fire main piping is leaking in the machinery space and fuel tank void. Submit plans for repairs to the satisfaction of the attending MI prior to replacement.
46 CFR 181.310(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 29 June 2023
Resolution: Stainless piping was successfully replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2023
Resolved
No more than four terminals shall be secured to any one terminal stud in accordance with ABYC E-11 Standard. The battery in the starboard engine compartment has more than 4 conductors secured to the terminal. Submit plans for repairs to the satisfaction of the attending MI prior to replacement.
46 CFR 183.130(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 29 June 2023
Resolution: Properly installed marine bus bar, no additional wire lengths added.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 22 May 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. The sewage tank piping is cracked.
46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 11 July 2023
Resolution: New sewage tank piping was replaced satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. There are dead end wires originating from the fuel purifier in the starboard machinery space.
46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 22 May 2023
Resolution: Verified capping of the dead end wires.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 22 May 2023
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The safety radiotelephony call sign differs from the station license.
46 CFR 184.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2023
Resolved 29 June 2023
Resolution: Call sign consistent among all 3 FCC documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 May 2023
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter. There were numerous life jackets lights that were inoperable or missing.
46 CFR 180.75(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 May 2023
Resolution: Verified installation of new lights.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 May 2023
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The hydrostatic release unit for the EPIRB was expired.
46 CFR 185.740(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 May 2023
Resolution: Installed new hydrostatic release unit for EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 May 2023
Resolved
Each survival craft, rescue boat, and launching appliance must be visually inspected to ensure its readiness for use. The painter line for the IBAs were incorrectly attached to the hydrostatic release unit.
46 CFR 185.720(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 22 May 2023
Resolution: Verified proper installation of painter line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2023
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. The starboard bolt for the steering post was loose.
46 CFR 176.814
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 May 2023
Resolution: Verified tightening of the bolt.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 May 2023
Resolved
Except when individual pumps are provided for separate spaces, individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. The bilge lines were not sufficiently marked at the manifold to distinguish the location of the lines.
46 CFR 182.510(c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 May 2023
Resolution: Verified new markings of lines on the manifold.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 October 2022
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. While re-floating the vessel after drydock, a pinhole leak was discovered under port fire pump strainer mounting bolt. Submit repair proposal and make repairs to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 October 2022
Resolution: Vessel cropped and replaced section of wasted hull. All sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 August 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment. Vessel has been altered to include a semi-permanent installation of fuel piping from the fuel fill containment, through the deck, and into the engine room. End result is that slop fuel is collected and stored in a 5 gallon bucket secured by a bungee chord in the engine rooms. Master states that this is normal operations for this vessel. Remove buckets, fuel hoses, and ball valves. Plug holes in deck to make watertight.
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 17 October 2022
Resolution: This unauthorized fuel catch was removed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 August 2022
Resolved
Each fire hydrant must have a valve installed to allow the firehose to be removed while the fire main is under pressure. Fire station at aft end of house found with seized valve. After repair, test of fire main required once vessel is back in water.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 October 2022
Resolution: Fire main tested and valves tested at all three stations. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. During drydock exam, found all but one engine mount bolts sheared on starboard engine. Found several sheared engine mount bolts on port engine. Replace all engine mounting bolts with new. Additionally, found missing bolt on starboard engine raw water inlet flange. Fit flange with bolt.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 October 2022
Resolution: All engine mounting bolts replaced with new. Starboard fire pump flange coupling rotated to incorporate new holes. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. While propellers were off, Bay Propeller found a crack in the starboard propeller. Replace in kind to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 October 2022
Resolution: Vessel replaced port and starboard props with new. SNs and sizes in narrative.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 August 2022
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may... require the vessel... to effect permanent repairs. Hole and a soft patch in weather deck was found near the transom above the port side lazarette. Both had been taped and painted over. Operator to submit repair proposal for approval prior to starting repair.
Due prior credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 September 2022
Resolution: Vessel has replaced with 12 x12 insert. Witnessed fit up, back gouge, and final with vacuum box and air lance NDT. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 29 August 2022
Resolved
At each inspection for certification and at every other vessel inspection, the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard or clog bilge pumping systems. Excess accumulation of oil, trash, debris, dust, and storage found in both engine rooms. Clean and prepare both engine spaces in order for full ISE to be completed and hazards removed from spaces. Remove portable fuel containers from vessel.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 October 2022
Resolution: Vessel cleaned all engine rooms and bilges. Portable fuel containers removed from vessel. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 August 2022
Resolved
A fire pump outlet must be fitted with a pressure gauge. Gauge found broken on fire pump. Make repairs to the satisfaction of attending [name withheld] (17OCT2022): Guage fitted, but pup will not come up to pressure and does not register on guage. Giving vessel 30 days to rectify but will not extend.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2022
Resolved 9 December 2022
Resolution: Tested both fire pumps. Both reached 65psi while running uncoupled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2022
Resolved
All cable and wiring must be installed with metal supports spaced not more than 24 inches apart. Wiring all over the vessel was found unsupported or dead ended. Support all necessary wiring and remove all unused wiring to the satisfaction of attending [name withheld] prior to credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 October 2022
Resolution: All wiring supported with metal brackets every 24 in.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2022
Resolved
Each distribution panel and switchboard must be in a dry location as practicable, adequately ventilated, and protected from falling water and debris. Several Blue Seas branded fuse blocks and buses are missing their drip shields. The toilet junction box and port lazarette high water switch junction boxes are wasted and exposed. Make repairs to the satisfaction of attending [name withheld] prior to credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 October 2022
Resolution: All boxes replaced and/or labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 August 2022
Resolved
The number of penetrations in watertight bulkhead must be minimized..and made watertight. There are three holes in the starboard engine room forward bulkhead. Propose repairs to attending MI prior to commencing work.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 13 September 2022
Resolution: Holes are high above waterline. Vessel has repaired by installing bolts with washers and silicone.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2022
Resolved
Protection from mechanical damage must be specifically considered and all protective covering or shields must be installed to the satisfaction of the cognizant [name withheld] generator raw water hose found chaffed where hose passes through deck hole. Make repairs to the satisfaction of attending MI.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 September 2022
Resolution: Replaced hose and built chafing gear from old fire hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2022
Resolved
Whenever there is a hazardous condition, as defined by 46 CFR 176.400, on board the vessel, the owner, master, agent, or person in charge shall immediately notify the Captain of the Port of the port of place of destination and the Captain of the Port or place in which the vessel is located of the hazardous condition. Vessel experienced a ruptured drip-less water seal on the starboard tail shaft while operating with passengers onboard. Master got vessel underway, without reporting to Coast Guard, and transited from home port of Monterey to Alameda for emergency drydock. Vessel to make repairs to the satisfaction of the attending Marine Inspector. Marine Inspector will witness set screw install.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 October 2022
Resolution: Witnessed installations of new shaft seals. Measurements of compression in narrative.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2022
Resolved
The employer must provide an Employee Assistance Program (EAP) for all crew-members. An EAP program was not fully established. No required EAP training conducted. Company must establish an EAP with training conducted for all crew-members, conduct appropriate training, and have designated EAP supervisory level trained personnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 7 October 2022
Resolution: Marine Employer DER submitted documentation to SEC SF showing training for EAP supervisory level trained personnel and designations.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 20 April 2022
Resolved
Employers must ensure that they and their crewmembers meet the requirements of this part. Employers are responsible for the actions of their officials, representatives, and agents in carrying out the requirements of this part. Vessel could not provide pre-employment chemical testing records for all Masters and the last three hires. Company owner to provide records of chemical testing for “ASTS Current Active Employee List” dated 08/16/2022 prior to carriage of passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2022
Resolution: DER of Marine Employer submitted last negative test result for operating Master for the company. All members on the current active employee have confirmation of negative pre-employment test on record.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 February 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Vessel's generators don't secure with activation of port and starboard fire-boys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2022
Resolved 2 March 2022
Resolution: MI witnessed proper shut down of gen sets with fire boy activation
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 February 2022
Resolved
Drug testing programs required by 46 CFR Part 16 must be conducted in accordance with 49 CFR 40, Procedures for Transportation Workplace Drug and Alcohol Testing Programs. The company’s drug and alcohol testing program has not met the Procedures for Transportation Workplace Drug and Alcohol Testing requirements since 2019. No Management Information System (MIS) data, required by 46 CFR 16.500, has been provided in accordance with 49 CFR 40.26 for calendar year 2020 or 2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2022
Resolved 15 March 2022
Resolution: Operator sent photos of company enrollment in approved drug testing program.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 February 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Vessel's aft dampers inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2022
Resolved 2 March 2022
Resolution: Operator sent photos of vessel dampers properly secured.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 February 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Vessel missing fuel shutoff station labels.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2022
Resolved 2 March 2022
Resolution: Operator sent photos of properly labeled fuel shut off valves.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Battery chargers must have an ammeter connected in the charging circuit. The new battery charger installed for the starboard battery bank does not have an ammeter connected in the charging circuit.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2022
Resolved 2 March 2022
Resolution: Operator sent picture of newly installed adequate battery charger that shows ammeter.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 February 2022
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control. Vessel's instructions for its fire-boy system illegible.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 8 October 2022
Resolution: New instructions posted. Resolved in activity #7544272
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other person, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel has multiple dead end wires in port lazarette and stbd pump room and one battery cable in the port engine room is missing its sheathing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2022
Resolved 15 March 2022
Resolution: Operator sent photos of removed dead end wires and repaired sheathing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Port E/R light cover broken.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2022
Resolved 8 October 2022
Resolution: Resolved in activity #7544272.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 February 2022
Resolved
A hatch exposed to the weather must be watertight. Vessel's hatches on the starboard side and port lazarette hatch are not watertight. Make watertight by next credit dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 September 2022
Resolution: All gaskets replaced. Resolved in activity 7544272.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 February 2022
Resolved
On a vessel of at least 7.9 meters(26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: a machinery space bilge, bilge well,or other spaces subject to flooding from sea water piping within the space. Vessel's high level alarms inoperable in stbd E/R and stbd pumproom.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 February 2022
Resolution: Float switches damaged. Fixed on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 February 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Vessel's bilge system incapable of pumping water out of port lazarette space.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 February 2022
Resolution: Loose fitting in bilge piping arrangement. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 August 2021
Resolved
Each inflatable liferaft required on a vessel by this part must have a capacity of 6 or more. Vessel rated to carry 156 passengers, however, inflatable liferafts onboard account for a max capacity of 136 persons. Two 50 person, one 30 person, and one 6 person life raft are present. Vessel's max passenger count alotted is 136 until liferafts are verified to account for more passengers. - 46 CFR 180.200
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 February 2022
Resolution: Lifesaving verified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2021
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Vessel has no markings to indicate location or size of life jackets on 2nd deck. 46 CFR 185.604(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2021
Resolved 17 August 2021
Resolution: Vessel purchased placards to convey information.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021
Resolved
46 CFR 183.200(a) Electrical equipment on a vessel must be installed and maintained to protect passengers/crew from electrical shock. Vessel's switchboard covers in the port engine room have open wiring and pose a hazard to the crew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2021
Resolved 10 March 2021
Resolution: Operator submitted photograph of repair/insert covering all access points to live electrical equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 March 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements. Vessel's port generator tray is filled with coolant and poses a hazard for normal operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2021
Resolved 9 March 2021
Resolution: Corrected deficiency on the spot. Operator cleaned out the generator's containment and verified that it is not leaking.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021
Resolved
46 cfr 183.200(A) Electrical equipment must be installed and maintained to protect passengers/crew from electrical hazards. Vessel's 110 volt galley outlet does not have a cover and poses a shock hazard to the crew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2021
Resolved 10 March 2021
Resolution: Operator installed a cover over the galley's 110v recepticle.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 March 2021
Resolved
A pre engineered fire extinguishing system must automatically shut down all power ventilation systems and engines. Vessels manual fire dampers for the port and starboard engine rooms do not adequately seal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2021
Resolved 10 March 2021
Resolution: Operator adjusted metal vent closure so that they adequately seal for both the port and stbd engine rooms. Verified via photograph.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2021
Resolved
A self priming power driven fire pump must be installed on a vessel. The minimum capacity for the pump must be at a pressure of not less than 60 psi at the pump outlet. The vessel's port fire pump has a leak (that needs to be repaired. Also, the starboard pump only outputs a pressure of 50 psi (though adequate hose stream observed).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 23 March 2021
Resolution: Operator repaired the fire pump and fixed the leak in the port pump. Operator sent a video of the starboard pump verifying that it was capable of discharging at 60 psi.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 March 2021
Resolved
A hatch exposed to the weather must be watertight. Vessel's port and starboard lazarette hatches do not adequately seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 23 March 2021
Resolution: Operator replaced the gaskets for the port and starboard hatches and verified that they are water tight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021
Resolved
Electrical equipment must be installed and maintained to protect passengers/crew from electrical hazards. Vessel's overhead light in the port lazarette dos not have a cover and poses a hazard to crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 23 March 2021
Resolution: Operator installed a cover over the overhead light in the port lazarette.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021
Resolved
Electrical equipment must be installed and maintained to protect passengers/crew from electrical hazards. Vessel's port lazarette has a 110v outlet with no cover. Additionally, the aft house has a 110v recepticle with a twist cover that is missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 10 March 2021
Resolution: Operator installed a cover over the recepticle.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 March 2021
Resolved
Each vessel certificated to operate on an oceans route in cold water must be provided with inflatable buoyant apparatus of aggregate capacity that will accommodate 100% of the total persons permitted on board. Vessel's 6 person life raft is not installed. Reduced passenger count to 150 total persons on board (147 pax and 3 crew).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 March 2022
Resolved 4 May 2021
Resolution: Operator put back in place lifesaving equipment. Passenger count returned to original allowance.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 2 June 2020
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. The painter for the IBA's was not hooked up to the proper section of the hydrostatic release; and therefore, would not properly break free from the vessel.
46 CFR 180.130(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 June 2020
Resolved 2 June 2020
Resolution: The hydrostatic release was correctly hooked up on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 7 March 2019
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and if inflatable, inflates automatically. The hydrostatic releases for the 03 50-person IBA's and the 01 6-person IBA were installed incorrectly. The hydrostatic release rigging was corrected on the spot to the satisfaction of the Marine Inspector.
46CFR180.130(a)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 March 2019
Resolved 8 March 2019
Resolution: Corrected on the spot to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 March 2019
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. The vessel does not currently have a marking at the entrance way to the upper deck. Provide marking IAW 46CFR185.602 to the satisfaction of the Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2019
Resolved 1 April 2019
Resolution: Recieved photographic evidence of the upper deck capacity sign.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 October 2018
Resolved
CLSN: Vsl is broadcasting Invalid Call Sign,
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 9 June 2020
Resolution: Vessel updated call sign to the satisfaction of the MI.
Electrical › Electric Supply System (service) › Cable
Issued 6 March 2018
Resolved
Prove black wire to the electric water heater to be marine grade or replace with same size marine grade wire. 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 9 June 2020
Resolution: Owner removed water heater from the vessel.
Construction/Loadline › Hull › Transverse Frame
Issued 10 April 2017
Resolved
Drill stops at end of each crack in starboard hull void #3 (sewage compartment) & V out and weld cracks. 46CFR176.610b
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 28 April 2017
Resolution: Observed required repairs until next dry dock.
Construction/Loadline › Hull › Transverse Frame
Issued 21 March 2017
Resolved
Crop/renew cracked frame in starboard hull void #3 (sewage compartment) at next drydock. Photos attached to Activity #6098414. 46CFR176.610a
Action required: 705 - Other - as specified
Resolved 2 November 2018
Resolution: Repaired to the satisfaction of the MI.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 March 2017
Resolved
Prove proper operation of light and audible alarm on bridge for starboard engine room pre-engineered fireboy activation. 46CFR181.420
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 21 March 2017
Resolution: Observed proper operation.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 June 2016
Resolved
01 Child PFD condemned, replace with new type I child PFD with waterlight.
46CFR180.71
Vessel is restricted to 15 child passengers at a time or 148 adult passengers until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 July 2016
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 28 June 2016
Resolved
1 Adult PFD missing waterlight. Replace with new waterlight. 46 CFR180.71
Vessel is restricted to 15 child passenger at a time or 148 adult passenger until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 July 2016