Records from 1985 to 1993. Most recent: inspection, 30 August 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 2 August 1993
Resolved
REPLACE HELICOPTER DECK SAFETY NET TO COMPLY WITH IMO RULE 13.3.3 NO LATER THAN 02 SEPTEMBER 1993.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Documentation
Issued 12 October 1989
Resolved
RENEW EXPIRED LOADLINE CERTIFICATE.
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989
Lifesaving
Issued 12 October 1989
Resolved
PROVIDE ANNUAL SERVICING OF 3-25 MAN INFLATABLE LIFERAFTS AND HYDROSTATIC RELEASES.
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989
Fire Fighting
Issued 12 October 1989
Resolved
PROVIDE COPIES OF RECENT FIREFIGHTING SERVICE REPORT WITH EVIDENCE OF REPLACEMENT AND/OR CORRECTION OF ALL NOTED ITEMS WITH DISCREPANCIES.
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989
Fire Fighting
Issued 12 October 1989
Resolved
PROVIDE COPY OF FOAM ANALYSIS REPORT.
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989
Unknown
Issued 12 October 1989
Resolved
CONDUCT A FIRE AND ABANDON RIG DRILL.
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989
Lifesaving
Issued 12 October 1989
Resolved
LOWER, RELEASE AND OPERATE 2 SURVIVAL CAPSULES.
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989
Fire Fighting
Issued 12 October 1989
Resolved
PROVIDE ONE SCBA BOTTLE WITH SATISFACTORY HYDRO DATE (LAST 5 YEARS).
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989
Deck/Cargo
Issued 12 October 1989
Resolved
RENEW KELLY HOSE ABOVE DRILL FLOOR.
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989
Fire Fighting
Issued 12 October 1989
Resolved
PROVIDE ONE RECENTLY CALIBRATED PORTABLE GAS DETECTION/OXYGEN METER.
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989
Documentation
Issued 12 October 1989
Resolved
IAW 46 CFR 109.121, PROVIDE AN APPROVED UPDATED OPERATIONS MANUAL.
Condition: Unknown
Due 12 October 1989
Resolved 12 October 1989
Fire Fighting
Issued 14 August 1987
Resolved
PROVIDE ANALYSIS OF FOAM FIRE FIGHTING SYSTEM BY HELIDECK.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Lifesaving
Issued 14 August 1987
Resolved
END FOR END FALLS FOR WHITAKER CAPSULES ON THE VESSELS 3 SURVIVAL CAPSULES.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Lifesaving
Issued 14 August 1987
Resolved
PROVIDE (2) SMOKE FLOATS FOR LIFERINGS.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Electrical
Issued 13 February 1986
Resolved
SUBMIT A HAZARDOUS AREAS DIAGRAM AND A DIAGRAM OF ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS. SEE 46 CFR 108.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Deck/Cargo
Issued 13 February 1986
Resolved
REPLACE STARBOARD CHECK VALVE IN BILGE SYSTEM OVERBOARD DISCHARGE LINE IN PUMP ROOM
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Fire Fighting
Issued 13 February 1986
Resolved
RESUBMIT FIRE AND SAFETY PLAN SHOWING PROPER LOCATION OF ALL BULKHEADS, ACCURATE FIRE CONTROL BOUNDARIES, AND EQUIPMENT LOCATIONS.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
PRIOR TO DRILLING, ON ALL EXPLOSION PROOF ENCLOSURES, REMOVE PAINT FROM THE FLANGED SIDES AND REPLACE MISSING BOLTS
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
UPDATE PANEL BOARD CIRCUIT DIRECTORIES.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Accommodation/Occupational Safety
Issued 13 February 1986
Resolved
RENEW NON-SKID ON HELIDECK.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Engineering
Issued 13 February 1986
Resolved
REPLACE SAFETY VALVES ON MARINE PORTABLE TANKS WITH SAFETY VALVES MEETING THE REQUIREMENTS OF 46 CFR PART 64.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Deck/Cargo
Issued 13 February 1986
Resolved
REATTACH BILGE SUCTION IN 16 CYLINDER CO2 ROOM.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Lifesaving
Issued 13 February 1986
Resolved
REPLACE CRACKED DOOR GLASS ON #1 CAPSULE
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Lifesaving
Issued 13 February 1986
Resolved
ADJUST LIMIT SWITCHES ON #1 CAPSULE.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
PROPERLY SPLICE POWER CABLE TO THE IMPRESSED CURRENT PROTECTION SYSTEM.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Navigation
Issued 13 February 1986
Resolved
REPLACE DAMAGED OR CLOUDED LENSES, INOPERATIVE ROTATING MECHANISMS, BAD BULBS, AND WING NUTS AND ATTACHMENT SCREWS ON THE CONSTRUCTION LIGHTS.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Construction/Loadline
Issued 13 February 1986
Resolved
REPLACE MISSING BOLTS AND NUTS IN MANHOLE COVER IN CREW'S HEAD, LOWER LEVEL
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
REPAIR HELIDECK PERIMITER LIGHTS.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Navigation
Issued 13 February 1986
Resolved
ON THE MAST HEAD, REPLACE THE MISSING GLOBE AND PROPERLY SECURE THE WIRING TO THE MASTHEAD LIGHT
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Fire Fighting
Issued 13 February 1986
Resolved
PROVIDE CO2 SYSTEM DIAGRAM AND OPERATING INSTRUCTIONS AT THE MANUAL CONTROLSTATION FOR THE 8 CYLINDER ROOM AND 16 CYLINDER ROOM CO2 SYSTEMS.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
ALL BATTERY POWERED "E" LIGHTS MUST BE OPERABLE AND HAVE A MINIMUM DURATIONOF 6 HOURS. REPAIR OR REPLACE DEFECTIVE UNITS.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
PROPERLY TERMINATE OR REMOVE THE DEAD END CABLE IN SACK STORAGE.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Construction/Loadline
Issued 13 February 1986
Resolved
PROVIDE EACH INDIVIDUALLY DOGGED WATER TIGHT OR WEATHER TIGHT DOOR WITH A PIPE TYPE DOGGING WRENCH.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Construction/Loadline
Issued 13 February 1986
Resolved
PRIOR TO DRILLING REPLACE WTD'S: MUD PIT RM FM PUMP RM, 16 CYL COS RM, STACK STOWAGE, & WX DECK; STBD JACK HOUSE; AT BOTH END OF THE PASSAGEWAY OUTBOARD OF THE GALLEY; STBD KEY MAIN DECK DOOR TO VESTIBULE.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
PRIOR TO DRILLING OPS COMPLETE REWIRING OF HAZARDOUS AREAS INCLUDING DRILL FLOOR, SHALE SHAKER AREA AND PIT ROOM. RENEW ALL CABLE WITH DETERIORATED OR DAMAGED ARMOR OR WITH SPLICES.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Lifesaving
Issued 13 February 1986
Resolved
PROVIDE TWO USCG APPROVED LIFE JACKETS COMPLETE WITH RETROFLECTIVE TAPE, LIGHTS, AND WHISTLES.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Deck/Cargo
Issued 13 February 1986
Resolved
REPLACE FLAME SCREENS IN FUEL OIL TANK VENT OUTLETS.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Construction/Loadline
Issued 13 February 1986
Resolved
PRIOR TO DRILLING EFFECTIVELY SEAL ALL USED AND UNUSED STUFFING TUBES PENETRATING BULKHEADS IN THE PIT ROOM AND STARBOARD JACK HOUSE.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
PRIOR TO DRILLING INSTALL AN EXPLOSION-PROOF FITTING AT THE FEEDER PENETRATION TO THE BUG BLOWER FAN MOTOR ON THE DRILL FLOOR.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Construction/Loadline
Issued 13 February 1986
Resolved
PRIOR TO DRILLING REPAIR 1 INCH HOLE IN THE MUD PIT ROOM OVERHEAD ABOVE THEMAERTIN-DECKER UNIT
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
LABEL ALL GENERAL ALARM BOXES.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
REMOVE THE MUD PUMP LUBRICATING PUMP FEEDER CABLE FROM THE DRIP PAN AND PROPERLY HANG IT.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Deck/Cargo
Issued 13 February 1986
Resolved
INSTALL REACH ROD TO BILGE EDUCTOR SUCTION VALVE IN 16 CYLINDER CO2 ROOM AND IN THE PUMP ROOM. SEE 46 CFR 56.50-50(C)91)
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Deck/Cargo
Issued 13 February 1986
Resolved
OVERHAUL CROSS OVER VALVES BETWEEN BILGE SYSTEM AND SALT WATER SYSTEMS IN PUMP ROOM.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Deck/Cargo
Issued 13 February 1986
Resolved
RENEW WASTED SALT WATER AND DRILL WATER LINES IN THE MACHINERY SPACES.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Fire Fighting
Issued 13 February 1986
Resolved
REPLACE BROKEN GAGES ON FIRE AND BALLAST PUMP DISCHARGE LINES.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Engineering
Issued 13 February 1986
Resolved
REMOVE THE RUBBER HOSE AND HARD PIPE THE DRAIN LINE FROM THE FUEL OIL SETTING TANK TO THE WASTER OIL TANK.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
REPLACE WOODEN HAND RAILS BEHIND THE SWITCHBOARDS IN THE SCR ROOM.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
CLOSE OPENING IN SWITCHBOARD FRONT IN SCR ROOM.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
REFIT AND MAKE OPERABLE A BUNK LIGHT FOR EACH BUNK IN THE ACCOMODATION SPACES.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
INSTALL A GENERAL ALARM BELL IN THE AFTER END OF THE SCR ROOM.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Electrical
Issued 13 February 1986
Resolved
PRIOR TO DRILLING INSTALL A "LOSS OF VENTILATION" SENSOR AND ALARM FOR THE STARBOARD KEY VESTIBULE
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Fire Fighting
Issued 13 February 1986
Resolved
PROVIDE 50% SPARE CHARGE DRY CHEMICAL POWDER FOR EACH REQUIRED EXTINGUISHERTHAT MAY BE RECHARGED BY THE CREW. PROVIDE 4 SPARE EXTINGUISHERS FOR EACH SIZE AND TYPE THAT MAY NOT BE RECHARGED BY THE CREW.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Deck/Cargo
Issued 13 February 1986
Resolved
PERMANENTLY REPAIR THE CROSS OVER LINE BETWEEN THE BILGE PUMPS.
Condition: Unknown
Due 13 February 1986
Resolved 13 February 1986
Lifesaving
Issued 24 April 1985
Resolved
SERVICE VESSEL'S INFLATABLE LIFERAFTS AND HYDROSTATIC RELEASES.
Condition: Unknown
Due 24 April 1985
Resolved 24 April 1985