MAURY USCG vessel records Sign in
← All vessels

HERCULES 200

HERCULES 200 is a 1979 mobile offshore drilling unit. The Coast Guard has recorded 85 inspections since 1980, most recently in May 2024, along with 168 deficiencies.

Records from 1980 to 2024. Most recent: inspection, 7 May 2024.

Built
1979
Last inspected
7 May 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8756526 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-51330

Inspections, by type

…with no type recorded38
Years with a record 30 calendar years (1980–2024)
The 85 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5853 - Convention (Subpart B), Gross Ton
1755 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 85

7 May 2024 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7912860
18 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7851077
25 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4391039
6 July 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4369997
2 February 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4236916
18 February 2011 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4068404
31 January 2011 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3936708
23 September 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3855831
3 September 2010 Plan Review (Other than "T") · COC-MODU Renew · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3846878
26 March 2010 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3703559
18 December 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3654613
2 April 2009 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3444966
27 October 2008 Deficiency Check · COC-MODU Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3358992
27 March 2008 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3172133
17 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3132209
1 November 2007 COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3109953
25 October 2006 COC-MODU Renew
Type not classified · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2810617
2 December 2004 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2251934
29 October 2004 COC-MODU Renew
Type not classified · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2225690
29 September 2004 In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2209030
29 January 2004 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1996815
26 January 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1735538
14 December 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718936
9 December 2002 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1716336
6 November 2002 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1701346
1 November 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1075919
24 July 2001 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1070910
18 January 2000 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 814529
9 November 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1445544
26 June 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 115056
12 March 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 155660
29 December 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 813249
11 November 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1364931
8 July 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 794641
25 June 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1127146
30 December 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402579
10 January 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425847
20 June 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1079816
21 March 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1078270
18 January 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1184551
12 January 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1400275
29 November 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 882303
8 September 1995 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 884237
30 June 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 881591
27 January 1995 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1435587
12 January 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1454145
14 January 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 850925
29 June 1993 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1156288
23 May 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 89967
10 May 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 123511
17 April 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 16447
2 April 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1152169
21 January 1993 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1133869
13 July 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 35236
29 June 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 37075
25 March 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1319807
19 February 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 115045
9 November 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 74637
16 May 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 908259
10 April 1991 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 928535
8 February 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 908893
8 February 1991 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 913529
16 February 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1328978
19 May 1987 Re-Inspection · Drydock Extension
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1332716
23 July 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 990832
15 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986519
10 April 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003241
10 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307744
11 March 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997043
3 January 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989895
3 January 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303614
11 October 1985 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994313
26 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295957
8 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984000
1 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287278
24 July 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280508
11 June 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280710
12 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282810
18 July 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964651
23 June 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969230
1 June 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965737
1 December 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968423
31 August 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 964529
21 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967484
26 March 1980 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 964912

Deficiency record · 168

Fire Fighting › Fixed Fire Detection System › Approval
Issued 17 September 2010 Resolved
Additional fire detection is being added to machinery spaces. Class/flag need to approve system, installation and fire/safety plan changes. 46 CFR 107.305
Action required: 705 - Other - as specified
Resolved 18 October 2013
Resolution: Cleared administratively.
Construction/Loadline › Structures › Ventilators
Issued 17 September 2010 Resolved
No closure devices were on exterior ventilation closures or fire dampers 46 CFR 11.33-9
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 18 October 2013
Resolution: Cleared administratively.
Construction/Loadline › Structures › Ventilators
Issued 17 September 2010 Resolved
Bulkhead iwo exhaust louvers wasted. 46 CFR 108.113
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 October 2013
Resolution: Cleared administratively.
Documentation › Certificates/Documents › MODU Safety Certificate
Issued 27 October 2008 Resolved
All class and flag certificates were endorsed for name change/ The class and Modu Cert were not endorsed for the annual survey and were therefore not valid. Required a valid MODU code cert be provided/
Condition: Improper/Lack of Maintenance
Due 3 November 2008
Resolved 4 November 2008
Resolution: Worked with Class to obtain valid MODU Cert.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 27 October 2008 Resolved
Provide manufactureres verification that the "T" used to replaces the deteriorated part in the #1 Life Boat breathing air supply system meets manufacturers requirements.
Condition: Improper/Lack of Maintenance
Due 3 November 2008
Resolved 29 October 2008
Resolution: [name withheld] Technician verified the part was adequate as a replacement part.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 27 October 2008 Resolved
Provide "A" Class fire damper in the main deck passageway bulkhead at the top of stairtower that leads from lower to upper accomodation space IAW class approves Fire Control Plan. **3NOV08: Operator installed a temporary non-classed louver until an approved damper could be located.
Condition: Improper/Lack of Maintenance
Due 27 November 2008
Resolved 22 October 2009
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 October 2008 Resolved
Adjust both Galley "A" class fire doors so the fully close.
Condition: Improper/Lack of Maintenance
Due 3 November 2008
Resolved 3 November 2008
Resolution: Verified doors function properly.
Stability › Watertight Integrity › General
Issued 27 October 2008 Resolved
Prior to floating rig, survey and properly adjust watertight doors to obtain proper seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2008
Resolved 22 October 2009
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 October 2008 Resolved
Complete annual servicing of both lifeboats
Condition: Improper/Lack of Maintenance
Due 7 November 2008
Resolved 3 November 2008
Resolution: [name withheld] complete the annual servicing of the lifeboats.
Construction/Loadline › Structures › Deck Plating
Issued 1 November 2007 Resolved
Prove emergency escape ladders are within 10 ft of water.
Condition: Unknown
Due 15 November 2007
Resolved 27 March 2008
Lifesaving › Lifeboat › Markings
Issued 1 November 2007 Resolved
Replace retro-tape on lifeboat #1.
Condition: Unknown
Due 30 November 2007
Resolved 30 November 2007
Resolution: Replaced.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 1 November 2007 Resolved
Prove ABS re-certification of port crane, including proof load test prior to use.
Condition: Unknown
Due 30 November 2007
Resolved 27 March 2008
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 25 October 2006 Resolved
Replace faded area classification plan posted in main deck passageway (plan is unreadable).
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 1 November 2007
Resolution: Replaced.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 25 October 2006 Resolved
Identify and mark locations of six (6) fire dampers concealed by recently installed ceiling tiles.
Action required: 705 - Other - as specified
Due 25 October 2006
Resolved 25 October 2006
Resolution: Locations were marked prior to departure from rig on date of inspection.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 25 October 2006 Resolved
Complete 5 year proof load test for cranes and provide documentation to OCMI per 46 CFR 107.260.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 1 November 2007
Resolution: Completed.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 25 October 2006 Resolved
Provide documentation/evidence to show most recent internal inspection of all pressure vessels IAW USCG MOC Policy Letter 01-03.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 1 November 2007
Resolution: Documentation provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 25 October 2006 Resolved
Provide operating instructions for fixed fire extinguishing system for stand-by generator space IAW manufacturer instructions.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 1 November 2007
Resolution: Instructions provided.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 25 October 2006 Resolved
Update operating manual to indicate actual maximum allowable air gap per 46 CFR 109.121(b)(3). Operating manual indicates max air gap at 54 feet - rig currently at 62 feet air gap.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 1 November 2007
Resolution: Manual updated.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 25 October 2006 Resolved
Replace doorknob on stateroom 25 (doorknob is missing).
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 1 November 2007
Resolution: Doorknob installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 October 2004 Resolved
Prove proper operation of obstruction lights.
Due 29 November 2004
Resolved 28 November 2004
Resolution: Replaced control for stbd light, test sat.
Operations/Management › Drills/Instruction › Fire
Issued 29 October 2004 Resolved
Prove crew participation of all crew members IAW 46CFR109.213(c)(2) for fire drills and abandonment drills.
Due 29 November 2004
Resolved 28 November 2004
Resolution: Noted POB on drilll sheet to show people in attendance.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 29 October 2004 Resolved
Provide guards or exhaust blankets for all exhaust manifolds on generators.
Due 29 November 2004
Resolved 28 November 2004
Resolution: Installed exhaust guard/blanket.
Engineering › Diesel Engine (auxiliary) › Block
Issued 29 October 2004 Resolved
Repair oil leak from real seal on #1 ship service generator. ( On the CG-835 we wrote #3 but it should have read #1 )
Due 29 November 2004
Resolved 28 November 2004
Resolution: Repaired oil leak.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 29 October 2004 Resolved
Replace Halon bottle on fixed fire extinguishing system for standby generator ( bottle failed on third party fire equipment report ) Provide standby extinguisher until replaced.
Due 29 November 2004
Resolved 28 November 2004
Resolution: Replaced.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 29 October 2004 Resolved
Prove over speeds on #1 & #2 ship service generators.
Due 29 November 2004
Resolved 28 November 2004
Resolution: Reset and checked sat.
Engineering › Pressure Vessel
Issued 29 January 2004 Resolved
Provide proof of internal exam or gauge readings for all P-tanks to the satisfaction of the CG Marine Inspector or ABS Surveyor. Extended deficiency until March 15th to allow for calculations provided by PE. LEGACY COMPONENT DESC: Internal Examination
Due 15 March 2004
Resolved 2 March 2004
Navigation › Collision/Grounding Avoidance
Issued 6 November 2002 Resolved
Prove synchronization of all four (4) obstruction lights after they are properly mounted. LEGACY COMPONENT DESC: Navigation Lights
Due 6 December 2002
Resolved 10 November 2002
Navigation › Collision/Grounding Avoidance
Issued 6 November 2002 Resolved
Change flasher in obstruction light to allow synchronization with other lights. LEGACY COMPONENT DESC: Navigation Lights
Due 6 November 2002
Resolved 6 November 2002
Electrical
Issued 6 November 2002 Resolved
Prove proper alarm works on video monitor cabinet, petron unit & drill graf, all purged but no alarm on loss of pressure.
Due 6 December 2002
Resolved 10 November 2002
Engineering › Bilge Water Management System
Issued 6 November 2002 Resolved
Prove proper operation of all bilge pumps. LEGACY COMPONENT DESC: Pump
Due 6 December 2002
Resolved 8 November 2002
Accommodation/Occupational Safety
Issued 1 November 2001 Resolved
REPAIR/REPLACE STBD ESCAPE LADDER TO EXTEND TO WITHIN 10 FEET OF WATER. LOWER AND/OR EXTEND PORT LADDER TO EXTEND WITHIN 10 FEET OF THE WATER.
Condition: Unknown
Due 15 November 2001
Resolved 19 November 2001
Lifesaving
Issued 1 November 2001 Resolved
ADJUST AND PROVE PROPER OPERATION OF LIFEBOAT LIMIT SYSTEM TO ACTIVATE WINCH CUTOUT AT 8-12" OF CABLE SPACE LEFT BETWEEN BOAT AND STOPS.
Condition: Unknown
Due 15 November 2001
Resolved 19 November 2001
Lifesaving
Issued 1 November 2001 Resolved
PROVIDE PROOF OF PROPER OPERATION OF LIFEBOAT WINCH AND BRAKE SYSTEM.
Condition: Unknown
Due 15 November 2001
Resolved 19 November 2001
Lifesaving
Issued 1 November 2001 Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE PROVISIONS OF 46 CFR 109.213 POST 1996EDITION. COMPLIANCE TO BE PROVEN BY THE DEVELOPMENT OF LOGS, TRAINING MATERIALS ETC.
Condition: Unknown
Due 1 December 2001
Resolved 19 November 2001
Accommodation/Occupational Safety
Issued 1 November 2001 Resolved
REPAIR CHAINS AT TOP OF LADDER AT V DOOR.
Condition: Unknown
Due 1 December 2001
Resolved 19 November 2001
Lifesaving
Issued 1 November 2001 Resolved
REPAIR STROKE COUNTER DISPLAY FOR CLASS I DIV II INSTALLATION.
Condition: Unknown
Due 1 December 2001
Resolved 19 November 2001
Lifesaving
Issued 1 November 2001 Resolved
ADJUST PURGE SENSOR FOR PRESSURE LOSS ON PETRON DISPLAY.
Condition: Unknown
Due 1 December 2001
Resolved 19 November 2001
Engineering
Issued 1 November 2001 Resolved
PROVE PROPER OPERATION OF HIGH WATER TEMP ALARM ON ALL FOUR GENERATORS,
Condition: Unknown
Due 1 December 2001
Resolved 10 December 2001
Lifesaving
Issued 1 November 2001 Resolved
PROVE PROPER OPERATION OF LOSS OF VENTILATION ALARM FOR MUD PIT ROOM AT RIGDRILL FLOOR.
Condition: Unknown
Due 1 December 2001
Resolved 19 November 2001
Lifesaving
Issued 1 November 2001 Resolved
MAKE MUD PIT BLKHEAD GAS TIGHT BETWEEN MUD PIT ROOM AND SAC ROOM. WELDING CABLE PENETRATION NEEDS TO HAVE PROPER GAS TIGHT FITTING.
Condition: Unknown
Due 1 December 2001
Resolved 19 November 2001
Engineering
Issued 1 November 2001 Resolved
PROVE PROPER OPERATION OF OVERSPEED SHUT DOWN ON #1 AND #2 GENERATOR.
Condition: Unknown
Due 9 December 2001
Resolved 10 December 2001
Engineering
Issued 9 November 1999 Resolved
Trouble shoot and repair as required cause of excessive compressed air consumption / leakage with respect to vessel's recent inability to start generators after vessel wide power outage.
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Construction/Loadline
Issued 9 November 1999 Resolved
Demonstrate proper operation and sealing of aft watertight door at Fire Pump compartment._x001C_
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Electrical
Issued 9 November 1999 Resolved
Demonstrate proper operation of Emergency Generator manual load asumption uopn activation of Total Rig Shutdown system.
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Construction/Loadline
Issued 9 November 1999 Resolved
Renew forward galley watertight door; test replacement and provide cognizant OCMI with documentation prior to rig movement, and no later than 15 December 99.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Electrical
Issued 9 November 1999 Resolved
Demonstrate satisfactory operation of cooling water high temperature shutdown mechanism for Number 3 Diesel Generator._x001C_ _x001C_
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Electrical
Issued 9 November 1999 Resolved
Demonstrate satisfactory operation of overspeed trip for Number Four DieselGenerator.
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Construction/Loadline
Issued 9 November 1999 Resolved
Adjust fore and aft watertight doors in way of Peak Tank room and forward of Mud Pump room; make any necessary repairs / replacements and chalk test.Provide cognizant OCMI with documentation prior to rig movement, and no later than 15 December 99.
Condition: Unknown
Due 9 November 1999
Resolved 9 November 1999
Electrical
Issued 9 November 1999 Resolved
Provide and install operational cooling water high temperature trip for Number One main diesel generator. Provide local coast guard with documentation attesting to satisfactory operation.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Fire Fighting
Issued 9 November 1999 Resolved
Demonstrate satisfactory operation of fire pump from emergency bus.
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Electrical
Issued 9 November 1999 Resolved
Repair as required Number Four (Emergency) Diesel Generator and demonstrateproper operation of automatic start up and load assumption.
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Fire Fighting
Issued 9 November 1999 Resolved
Conduct fire drill to satisfaction of attending USCG inspector.
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Documentation
Issued 9 November 1999 Resolved
Provide documentation for air receiver relief valve testing.
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Documentation
Issued 9 November 1999 Resolved
Provide documentation of lifeboat release gear tests.
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Documentation
Issued 9 November 1999 Resolved
Provide documentation for lifeboat davit wire rope certification.
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Documentation
Issued 9 November 1999 Resolved
Provide documentation of lifeboat weight test.
Condition: Unknown
Due 15 November 1999
Resolved 23 November 1999
Accommodation/Occupational Safety
Issued 30 December 1997 Resolved
Repair starboard escape ladder on bow where buckled.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Accommodation/Occupational Safety
Issued 30 December 1997 Resolved
Properly make bunk in hospital space accessible from both sides. Organize hospital in orderly fashion.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Fire Fighting
Issued 30 December 1997 Resolved
Crop and renew 90 degree elbow in upper joint on firemain piping to hydrantat station #5.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Construction/Loadline
Issued 30 December 1997 Resolved
Complete repairs per ABS survey report dated 16DEC97. Provide statement of fact to [name withheld] on completed items.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Electrical
Issued 30 December 1997 Resolved
Conduct emergency battery 2 hour load test and log properly.
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Construction/Loadline
Issued 30 December 1997 Resolved
Complete proper repairs to bow leg to satisfaction of attending class surveyor. Provide statement of fact to [name withheld].
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Lifesaving
Issued 30 December 1997 Resolved
Complete items 1-3 on enclosure (1), "Interim Policy guidance on lifesavingregulations in 46 CFR Subchapter I-A."
Condition: Unknown
Due 30 December 1997
Resolved 30 December 1997
Construction/Loadline
Issued 10 January 1997 Resolved
REPAIR/ADJUST WATERTIGHT DOORS THROUGHOUT RIG.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Lifesaving
Issued 10 January 1997 Resolved
REPAIR GENERAL ALARM IN SHALE SHAKER AREA.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Navigation
Issued 10 January 1997 Resolved
REPAIR NAVIGATION LIGHTS PRIOR TO RIG MOVE.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Electrical
Issued 10 January 1997 Resolved
REPAIR PURGE ALARM ON DRILL FLOOR.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Fire Fighting
Issued 10 January 1997 Resolved
PLACE SCBA BOTTLE IN FIREMAN'S OUTFIT.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Lifesaving
Issued 10 January 1997 Resolved
PLACE TAIL ROTOR WARNING SIGNS AT ALL ENTRANCES TO HELIDECK.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Lifesaving
Issued 10 January 1997 Resolved
PLACE RETROREFLECTIVE TAPE ON LIFE RINGS.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Accommodation/Occupational Safety
Issued 10 January 1997 Resolved
PLACE/REPAIR BUNKLIGHTS IN ACCOMODATION SPACES.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Accommodation/Occupational Safety
Issued 10 January 1997 Resolved
PLACE MARPOL PLACARD ON BOARD.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Engineering
Issued 10 January 1997 Resolved
STENCIL FUEL TRANSFER HOSE IAW 33 CFR 154.500.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Electrical
Issued 10 January 1997 Resolved
LABEL DISTRIBUTION PANELS THROUGHOUT RIG. MAKE PANEL LATCHES OPERABLE.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Electrical
Issued 10 January 1997 Resolved
REPLACE EXPOSED WIRING AND BROKEN ELECTRICAL FITTINGS ON DRILL FLOOR. ENSURE ALL ELECTRICAL FITTINGS, WIRING AND SYSTEMS ARE INTRINSICALLY SAFE, EXPLOSION PROOF OR PRESSURIZED/PURGED IN SHALE SHAKER AREA, MUD PIT AND ON DRILL FLOOR.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Fire Fighting
Issued 10 January 1997 Resolved
LABEL ALL FIRE STATIONS IAW FIRE CONTROL PLAN.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Electrical
Issued 10 January 1997 Resolved
LABEL EMERGENCY LIGHTING THROUGHOUT RIG.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Lifesaving
Issued 10 January 1997 Resolved
REPLACE OUTDATED LIFE PRESERVER LIGHTS.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Accommodation/Occupational Safety
Issued 10 January 1997 Resolved
INSTALL 100 PSI SAFETY RELIEF VALVES ON ALL HOT WATER HEATERS.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Electrical
Issued 10 January 1997 Resolved
ADJUST OVERSPEED SHUTDOWN ON GENERATOR #2 AND #3.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Lifesaving
Issued 10 January 1997 Resolved
REMOVE PAINT AND SOLVENTS FROM SAFETY EQUIPMENT LOCKER AND PROPERLY STOW INPAINT LOCKER.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Lifesaving
Issued 10 January 1997 Resolved
MAKE REPAIRS AND INSTALL EQUIPMENT ON LIFEBOATS IAW REVISIONS TO 46 CFR 107-109 AND LISTING IN MINS, CASE: MI97000500.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Documentation
Issued 12 January 1996 Resolved
CONDUCT ANNUAL INSPECTION OF CRANES, PROVIDE DOCUMENTATION FROM ABS.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Electrical
Issued 12 January 1996 Resolved
REPLACE/REPAIR REVERSE CURRENT RELAYS ON ALL 3 GENERATORS.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Electrical
Issued 12 January 1996 Resolved
REPLACE/REPAIR OVERSPEEDS ON NO.1 AND NO.2 GENERATORS.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Lifesaving
Issued 12 January 1995 Resolved
CONDUCT SATISFACTORY WEIGHT TEST OF LIFEBOAT
Condition: Unknown
Due 12 January 1995
Resolved 12 January 1995
Lifesaving
Issued 21 January 1993 Resolved
PROVIDE STORM OIL, CONDENSED MILK OR PROVISIONS, SPARE OAR LOCKS TO MEET INTERNATIONAL REQUIREMENTS ON LIFEBOAT EQUIPMENT.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Lifesaving
Issued 21 January 1993 Resolved
PROVIDE A 406MHZ I EPIRB TO MEET INTERNATIONAL REQUIREMENTS.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Lifesaving
Issued 21 January 1993 Resolved
PROVIDE DOCUMENTATION THAT DRY BULK TANKS ID#=12032,12034,12035 HAVE BEEN INTERNALLY EXAMINED BY THE DOCUMENTING NATION'S REPRESENTATIVE (CLASS SOCIETY) AT NEXT RIG MOVE.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Fire Fighting
Issued 10 April 1986 Resolved
PROVIDE ADDITIONAL SUPPORT FOR THE FIRE MAIN ON THE HELO DECK.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Lifesaving
Issued 10 April 1986 Resolved
REPAIR INOPERATIVE SHIFT CABLE FOR THE LIFEBOAT. THE CABLE IS BROKEN BUT CAN BE SHIFTED BY HAND OF THE REDUCTION GEAR. COMPLIANCE DATE IS 07APR86.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Navigation
Issued 10 April 1986 Resolved
PROVIDE CORRECT LAMPS FOR THE NAVIGATIONAL SIDELIGHTS AND STERNLIGHTS.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Construction/Loadline
Issued 10 April 1986 Resolved
REPAIR THE FOLLOWING WATERTIGHT AND GASTIGHT: BLOWERS, CLOSURES ON THE MAINDECK; TANK VENT MISSING SCREEN AND CHECK VALVE MAIN DECK STBD JACKING HOUSE, PROVIDE PROPER SIZE HAND WHEEL ON W/T DOOR TO PORT JACKING HOUSE.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Documentation
Issued 10 April 1986 Resolved
PROVIDE ON BOARD COAST GUARD STAMPED APPROVED COPY OF THE VESSELS OPERATINGMANUAL. THE MANUAL CURRENTLY ON BOARD IS STAMPED 10 APRIL 1985 BY ABS. THESTABILITY LETTER REFERENCES A 23 JUNE 1980 STAMPED OPERATING MANUAL AND THELOADLINE CERTIFICATE REFERENCES 25 AUGUST 1981 STABILITY LETTER.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Fire Fighting
Issued 10 April 1986 Resolved
RESUBMIT FIRE CONTROL AND HAZARDOUS LOCATION PLAN FOR APPROVAL DUE TO ERRORS IN NUMBER OF HYDRANTS, LOW VELOCITY APPLICATORS AND CLASS/DIV LOCATIONS.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Lifesaving
Issued 10 April 1986 Resolved
PROVIDE ONE (1) ADDITIONAL BOAT HOOK FOR THE LIFEBOAT.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Construction/Loadline
Issued 10 April 1986 Resolved
REPLACE MISSING HAND RAILS MAIN DECK UNDER DRILL FLOOR AND STBD. MAIN DECK LOWER RAIL.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Fire Fighting
Issued 10 April 1986 Resolved
REPLACE NITROGEN HOSE BETWEEN REULATOR AND DRY CHEMICAL BOTTLE B-V FIRE EXTINGUISHER PORT, HELO DECK. PURGE DRY CHEMICAL DISCHARGE HOSE DUE TO WATER IN HOSE.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Accommodation/Occupational Safety
Issued 10 April 1986 Resolved
INSSTALL RELIEF VALVES ON HOT WATER HEATERS NOT TO EXCEED 100 PSIG AND 200F
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Construction/Loadline
Issued 10 April 1986 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF BOTH MUD PUMP RELIEF VALVES.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Electrical
Issued 10 April 1986 Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHT (BATTLE LANTERN) ON PORT SIDE OF JACK ROOM.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Electrical
Issued 10 April 1986 Resolved
DEMONSTRATE PROPER OPERATION OF "LOSS OF PURGE" ALARM AT DRILLERS CONSOLE.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Electrical
Issued 10 April 1986 Resolved
DEMONSTRATE PROPER OPERATION OF OVERSPEED TRIP ON EMERGENCY GENERATOR.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Electrical
Issued 10 April 1986 Resolved
DEMONSTRATE PROPER OPERATION OF LOW LUBE OIL ALARM ON EMERGENCY GENERATOR.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Engineering
Issued 10 April 1986 Resolved
PROVIDE RELIEF VALVE FOR RIG AIR RECEIVER TO RELIEVE AT NOT MORE THAN 150 PSIG.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Accommodation/Occupational Safety
Issued 10 April 1986 Resolved
INSTALL RELIEF VALVES ON PORTABLE WATER AND SANITARY WATER PRESSURE TANKS TO RELIEVE AT NOT MORE THAN THE MAXIMUM ALLOWABLE WORKING PRESSURE OF THE TANKS.
Condition: Unknown
Due 10 April 1986
Resolved 10 April 1986
Unknown
Issued 3 January 1986 Resolved
OPEN ALL SEA SUCTION AND OVERBOARD VALVES FOR COAST GUARD INSPECTION REF: 46 CFR 107.267.
Condition: Unknown
Due 3 January 1986
Resolved 3 January 1986
Unknown
Issued 3 January 1986 Resolved
CONDUCTED AND UNDERWATER EXAMINATION OF THE LET TO MAT CONNECTIONS AND MAT REF: 46CFR 107.267
Condition: Unknown
Due 3 January 1986
Resolved 3 January 1986
Construction/Loadline
Issued 11 October 1985 Resolved
CONDUCT VIDEO INSPECTION OF MAT SKIRT AND MAT BOTTOM. INSPECTION TO BE CONDUCTED IN THE PRESENCE OF A COAST GUARD INSPECTOR UPON THE NEXT RIG MOVE
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Electrical
Issued 8 May 1985 Resolved
OPEN ALL SEA SUCTION AND OVERBOARD VALVES FOR COAST GUARD INSPECTION. REF: 46 CFR 107.267
Condition: Unknown
Due 8 May 1985
Resolved 8 May 1985
Construction/Loadline
Issued 8 May 1985 Resolved
CONDUCTED AND UNDERWATER EXAMINATION OF THE LET TO MAT CONNECTIONS AND MAT.REF: 46 CFR 107.267
Condition: Unknown
Due 8 May 1985
Resolved 8 May 1985
Construction/Loadline
Issued 8 May 1985 Resolved
MAKE OPERABLE THE AUDIBLE ALARM FOR THE AIR PURGE SS STEM ON THE GAS DECTECTOR LOCATED ON THE DRILL FLOOR. REF: 46 CFR 111.105-10
Condition: Unknown
Due 8 May 1985
Resolved 8 May 1985
Unknown
Issued 8 May 1985 Resolved
THE BELOW LISTED DEFICIENCIES PERTAIN TO THE M/V SABINE I, O.N. 606527.
Condition: Unknown
Due 8 May 1985
Resolved 8 May 1985
Fire Fighting
Issued 1 April 1985 Resolved
REPLACE THE GASKET ON THE DOOR FOR THE EMERGENCY GENERATOR ROOM. 46 CFR 108.455
Condition: Unknown
Due 1 April 1985
Resolved 1 April 1985
Fire Fighting
Issued 1 April 1985 Resolved
PROVIDE EVIDENCE OF A SATISFACTORY INSTALLATION TEST OF THE HALON SYSTEM FOR THE MAIN GENERATOR AND EMERGENCY GENERATOR ROOM. 46 CFR 108.449.
Condition: Unknown
Due 1 April 1985
Resolved 1 April 1985
Unknown
Issued 1 April 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL SABINE I, DN606527
Condition: Unknown
Due 1 April 1985
Resolved 1 April 1985
Fire Fighting
Issued 1 April 1985 Resolved
PROVIDE AUTOMATIC CLOSING DAMPERS FOR FAN SUPPLY OPENINGS LOCATED OVER THE SWITCHBOARD IN THE EMERGENCY GENERATOR ROOM. 46 CFR 108.181.
Condition: Unknown
Due 1 April 1985
Resolved 1 April 1985
Fire Fighting
Issued 1 April 1985 Resolved
COMPLETE THE INSTALLATION HOOKUP OF THE AUTOMATINC LOUVER CLOSURES FOR THE EMERGENCY GENERATOR. 46 CFR 108.455.
Condition: Unknown
Due 1 April 1985
Resolved 1 April 1985
Fire Fighting
Issued 1 April 1985 Resolved
WELD THE PIPE PENETRATIONS IN THE EMERGENCY GENERATOR HOUSE IN WAY OF THE PIPING FOR THE FIXED HALON SYSTEM. 46 CFR 56.
Condition: Unknown
Due 1 April 1985
Resolved 1 April 1985
Unknown
Issued 23 June 1983 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE MODU SABINE I, DN606527.
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Unknown
Issued 23 June 1983 Resolved
PROPERLY SERVICE ALL PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH 46 CFR 109.223.
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Unknown
Issued 23 June 1983 Resolved
REPLACE THE GALLEY DOOR AUTOMATIC CLOSING DEVICE IN ACCORDANCE WITH 46 CFR 108.135.
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Unknown
Issued 23 June 1983 Resolved
SUBMIT FOR APPROVAL THE VESSEL'S FIREFIGHTING AND LIFESAVING PLAN.
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Unknown
Issued 23 June 1983 Resolved
PROVIDE THE FOLLOWING ADDITIONAL EQUIPMENT FOR THE LINE-THROWING GUN: (1) ONE SERVICE PROJECTILE; (2) ONE SERVICE LINE; (3) 500' AUXILIARY LINE.
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Unknown
Issued 23 June 1983 Resolved
REPLACE THE BULK CHEMICAL TANK RELIEF VALVES WITH ASME APPROVED VALVES OF THE HAND RELIEF TYPE WITH A SET PRESSURE NOT MORE THAN 40 PSI.
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Unknown
Issued 23 June 1983 Resolved
REPAIR BOTH BILGE PUMPS.
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Unknown
Issued 23 June 1983 Resolved
REPAIR CLOSURES ON MUD PIT DOORS.
Condition: Unknown
Due 23 June 1983
Resolved 23 June 1983
Unknown
Issued 1 December 1982 Resolved
DRYDOCK RIG OR SUBMIT PROPOSAL FOR SPECIAL EXAMINATION IN LIEU OF DRYDOCK- ING TO [name withheld].
Condition: Unknown
Due 1 December 1982
Resolved 1 December 1982
Unknown
Issued 21 April 1982 Resolved
SUBMIT DRAWINGS/PROPOSAL FOR USCG APPROVAL FOR SUITABLE PAINT LOCKER - 46 CFR 103.127.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Fire Fighting
Issued 21 April 1982 Resolved
PROVIDE THE FOLLOWING FOR EACH FIREMAN'S OUTFITS: ONE THREE CELL FLASHLIGHTWITH SPARE BAT. & BULB, ONE OXYGEN METTER & EXPLOSIVE METER.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Navigation
Issued 21 April 1982 Resolved
CHECK AND REPLACE ALL OBSTRUCTIONS LIGHT BULBS AND CHANGES AS NECESSARY - 33 CFR 67.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Documentation
Issued 21 April 1982 Resolved
PROVIDE CG-835 REQUIREMENTS ISSUED 04 SEPTEMBER 1981.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Fire Fighting
Issued 21 April 1982 Resolved
MARK FIRE STATIONS AS NECESSARY - 46 CFR 108.633.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Deck/Cargo
Issued 21 April 1982 Resolved
HAVE STARBOARD CRANE CERTIFIED AFTER REPAIR - 46 CFR 109.439.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Navigation
Issued 21 April 1982 Resolved
PROVIDE A STERN LIGHTS AND DAY SHAPE FOR BEING TOWED - 1972 COLREGS RULE 24E.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Navigation
Issued 21 April 1982 Resolved
PROVIDE NOT UNDER COMMAND SHAPES AND LIGHTS - 1972 COLREGS RULE 27E.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Navigation
Issued 21 April 1982 Resolved
PROVIDE ANCHOR LIGHTS AND SHAPES - 1972 COLREGS RULE 30.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Navigation
Issued 21 April 1982 Resolved
PROVIDE VESSEL GROUND LIGHTS AND SHAPES - 1972 COLREGS, RULE 30D.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Navigation
Issued 21 April 1982 Resolved
PROVIDE A WHISTLE AND A BELL - 1972 COLREGS, RULES 33A, 35, 36 AND 37.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Accommodation/Occupational Safety
Issued 21 April 1982 Resolved
PROVIDE AN ASME APPROVED RELIEF VALVE SUITABLE FOR THE BULK MATERIAL AIR RECEIVER AND THE SIX (6) BULK TANKS - 46 CFR 54.15.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Accommodation/Occupational Safety
Issued 21 April 1982 Resolved
TEST ALL RELIEF VALVES FOR AIR RECEIVERS AND BULK TANKS - 46 CFR 61.10- 5(I).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Documentation
Issued 21 April 1982 Resolved
RESUBMIT HAZARDOUS LOCATIONS PLAN TO [name withheld] FOR APPROVAL - 46 CFR111.05-5(D)22.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Lifesaving
Issued 21 April 1982 Resolved
PROVIDE (A) TWO ORANGE SMOKE FLARES AND (B) THREE TOTAL 3 CELL FLASLIGHTS WITH SPARE BATTERIES & BULBS FOR LIFEBOAT - NVC 4-78 3.D(8).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Deck/Cargo
Issued 21 April 1982 Resolved
PROVIDE DEAD MAN TYPE FILL NOZZELS FOR CRANE FUEL STATIONS - 33 CFR 156.130(D).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Lifesaving
Issued 21 April 1982 Resolved
PROVIDE UP-TO-DATE SMOKE FLARE FOR STARBOARD QUICK RELEASE RING BUOYS - NVC4-78 CH-1 SUBPART E.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Lifesaving
Issued 21 April 1982 Resolved
PROVIDE BRACKETS FOR ALL RING BUOY WATER LIGHTS NOT N0W EQUIPPED - 46 CFR 108.515.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
PROVIDE AN EXPLOSION PROOF GENERAL ALARM BELL OUTSIDE MUD PIT IN SACK ROOM OR MOVE PRESENT BELL OUTSIDE HAZ. LOC. - NVC 4-78 3.D(10)(B).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
PROVIDE EXPLOSION PROOF JUNCTION BOX WITH EYS SEALS ABOVE MUD PIT DOOR IN SACK ROOM - NVC 4-78 3.D(10)(B).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Construction/Loadline
Issued 21 April 1982 Resolved
PROVIDE DOOR CLOSURES FOR BOTH MUD PIT DOORS - NVC 3.D(10)(B).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
REPAIR WIRING BETWEEN CONTROLLER AND MOTOR FOR MUD SCRUBBER AND MAKE IN- STALLATION SUITABLE FOR A HAZARDOUS LOCATION NVC 4-78 E.D(10)(B).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
MOVE TRANSFORMERS FROM STBD SIDE OF DRILL FLOOR TO AN AREA OUTSIDE HAZ. LOC. OR MAKE SAME SUITABLE FOR HAZ. LOC. - NFPA 496.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
PROVIDE LIGHTS SUITABLE FOR A HAZ. LOC. AROUND UPPER EDGE OF PERIMETER OF DRILL FLOOR OR MOVE THEM OUT OF H/L - NVC 4-78.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
PROVIDE EYS SEAL FOR MOTOR TO DEGASSER - NVC 4-78 3.D(10)(B).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
PROVIDE LIGHT BULB AND LENS COVER FOR LOW LEVEL INDICATOR ON MUD TANKS IN MUD PITS - NVC 4-78 3.D(10)(B).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
REPAIR LIGHT BULBS AND LENS COVERSAND SWITCH BUTTONS FOR #2 AND #3 MUD AGITATOR CONTROLLER - NVC 4.78 3.D(10)(B).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
REPAIR WIRING TO TOTCO VISUALOGGER - 46 CFR 111.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
PROVIDE A PURGING SYSTEM FOR CAMERON STROKE COUNTER - NFPA 496.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
MAKE OPERABLE AIR PURGE SYSTEMS FOR DRILLERS CONSOLE, ADAIR UNIT AND TOTCO VISUALIZER- NFPA 496.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
PROVIDE EXPLOSION PROOF ALARM FOR ADAIR UNIT - NVC 4-78 3.D(10)(B).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Deck/Cargo
Issued 21 April 1982 Resolved
PROPERLY REPAIR INTAKE (SUCTION) VENT DUCT FOR MUD PITS OR REPLACE SAME - NVC 4-78 3.D(10).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Deck/Cargo
Issued 21 April 1982 Resolved
REPAIR VENTILATION LOSS ALARM FOR MUD PITS - NVC 4-78 3.D(10).
Condition: Unknown
Due 21 May 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
PROVIDE RUBBER MAT FOR EMERGENCY GENERATOR SWITCHBOARD - 46 CFR 111.30-11.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Construction/Loadline
Issued 21 April 1982 Resolved
REPLACE DOG TO EMERGENCY GENERATOR ENCLOSURE - NVC 3.D.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Fire Fighting
Issued 21 April 1982 Resolved
PROVIDE TWO (2) C-II EXTINGUSHERS FOR THE SCR ROOM - 46 CFR 108.495(A).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
PROPERLY INSTALL AND SUSPEND WIRING TO STROKE COUNTERS ON MUD PUMPS - 46 CFR 11.60.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
REMOVE DEAD END WIRE FROM MUD PIT (OVER DOOR TO SACK ROOM) - 46 CFR 111.60-17.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Deck/Cargo
Issued 21 April 1982 Resolved
PROVIDE ONE (1) BARREL CONTAINMENT FOR ALL FUEL TANK VENTS - 33 CFR 155.320(A)(2).
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982
Electrical
Issued 21 April 1982 Resolved
PROVIDE EYS SEALS FOR HYDRAULIC BRAKE JUNCTION BOX - NVC 4-78.
Condition: Unknown
Due 21 April 1982
Resolved 21 April 1982

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.