MAURY USCG vessel records Sign in
← All vessels

HOKUNANI

HOKUNANI is a 1980 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1985, most recently in June 2005, along with 159 deficiencies and 1 casualty investigation in 2005.

Records from 1985 to 2005. Most recent: inspection, 1 June 2005.

Built
1980
Last inspected
1 June 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WQZ6999
Flag
UNITED STATES
—
Maury page id
psix-51341

Inspections, by type

…with no type recorded11
Years with a record 21 calendar years (1985–2005)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Net Ton
44 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WQZ6999MMSI not assigned · expired · compulsorily equipped · granted 17 September 1998, cancelled 24 January 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 53

1 June 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2376146
1 April 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2326271
23 March 2004 Administrative Inspection · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2029153
24 June 2003 Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1853333
7 August 2002 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1648591
30 November 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1076860
5 November 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 772026
29 October 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1366632
6 March 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391502
26 October 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1055169
20 October 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369860
23 September 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365384
14 May 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1410098
30 March 1999 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 784183
17 March 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369074
31 December 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 809921
21 October 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1388636
26 May 1998 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1128920
5 November 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 783451
29 September 1997 Re-Inspection · Plan Review "T" Boat · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368422
25 February 1997 Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364055
11 October 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354017
23 September 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1421204
8 November 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355527
28 September 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1456304
1 June 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 879620
15 May 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1229117
3 April 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387738
25 November 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1385347
22 September 1994 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377273
30 September 1993 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356418
26 March 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1152941
12 November 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 961234
19 July 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1246106
10 July 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937484
25 June 1990 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 927279
4 October 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1036149
12 September 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1041548
10 February 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1342908
19 February 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1338460
12 February 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1025632
17 December 1987 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1006832
3 December 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1004709
26 March 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1018597
12 March 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1016906
12 February 1987 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1014499
28 July 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1301096
7 April 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1309248
28 February 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989215
7 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1288737
10 April 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 982256
19 March 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 982702
6 March 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 978699

Deficiency record · 159

Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 23 March 2004 Resolved
Provide a waste management plan in accordance with 33 CFR 151.57.
Due 7 April 2004
Resolved 23 March 2004
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 March 2004 Resolved
Provide a Coast Guard Light list in accordance with 46 CFR 184.420.
Due 7 April 2004
Resolved 23 March 2004
Documentation › Markings/Placards
Issued 23 March 2004 Resolved
Mark hull with name/hailing port in accordance with 46 CFR 67.123. LEGACY COMPONENT DESC: Hull Identification Number (HIN)
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 9 April 2004
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 23 March 2004 Resolved
Provide an emergency instruction list in accordance with 46 CFR 185.510.
Due 7 April 2004
Resolved 23 March 2004
Lifesaving › Lifejacket/PFD (General)
Issued 23 March 2004 Resolved
Provide required amount of approved personal floatation devices in accordance with 46 CFR 180.71. Amount of passengers restricted to (50) Adults and (5) Children until corrected. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 9 April 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 23 March 2004 Resolved
Replace missing 2" X 4" vertical rail supports (4 each) on bridge deck. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 9 April 2004
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Replace rotted wood at baseboard in starboard head. LEGACY COMPONENT DESC: Deck Plating
Due 9 April 2004
Resolved 9 April 2004
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Replace rotted wood in #2 port compartment by overhead shower pipe entry.
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 9 April 2004
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Replace rotted wood on main deck overhead at midships.
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 9 April 2004
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Replace rotted 7th step of ladder to bridge deck.
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 9 April 2004
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 23 March 2004 Resolved
Pump and dry port & starboard bilges for shaft log inspection.
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 23 March 2004
Engineering › Steering Gear System
Issued 23 March 2004 Resolved
Realign steering linkage to rest on roller in port steering compartment. LEGACY COMPONENT DESC: Linkage
Action required: 705 - Other - as specified
Due 7 April 2004
Resolved 9 April 2004
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Replace all rigging for the masts or have a qualified rigger certify existing rigging is adequate. LEGACY COMPONENT DESC: Superstructure
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2004
Construction/Loadline › Hull
Issued 24 June 2003 Resolved
Fair out to good laminate and reapply sheathing to a) 1" fwd of port skeg and b) 5" hole fwd of port eng. intake valve. LEGACY COMPONENT DESC: Hull Laminate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 July 2003
Construction/Loadline › Hull
Issued 24 June 2003 Resolved
Repair all blisters as marked. LEGACY COMPONENT DESC: Blisters
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 24 June 2003 Resolved
Repair all ladders in the following compartments: a) #5 port and stbd and b) #7 stbd. LEGACY COMPONENT DESC: Ladders
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 July 2003
Engineering › Bilge Water Management System › Pump
Issued 24 June 2003 Resolved
Repair bilge pump in #6 port compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 July 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 June 2003 Resolved
Replace all bad wood on deck in main seating room (near # 3, 4, and 6 stbd compartment). LEGACY COMPONENT DESC: Main seating room
Condition: Improper/Lack of Maintenance
Due 1 August 2003
Resolved 23 March 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 June 2003 Resolved
a) Replace and strengthen railings/ bad wood and b) Install safety glass in window. LEGACY COMPONENT DESC: Topside deck (02 level)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 23 March 2004
Construction/Loadline › Hull
Issued 24 June 2003 Resolved
Aft section of underside wing area, grind down and repair to good wood. LEGACY COMPONENT DESC: Underside wing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 23 March 2004
Construction/Loadline › Structures
Issued 24 June 2003 Resolved
In port and stbd aft comparments' ceilings, replace and grind down to good wood. LEGACY COMPONENT DESC: Port and Stbd Aft Compartment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 23 March 2004
Stability
Issued 24 June 2003 Resolved
Submit plans for the installation of aft passenger deck, to include stairs/ ladders. LEGACY COMPONENT DESC: Plans submittal
Action required: 705 - Other - as specified
Due 1 August 2003
Resolved 27 March 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 7 August 2002 Resolved
Provide proof of CPR and First Aid Certification for at least 50% of the crew. NVIC 1-91 LEGACY COMPONENT DESC: First Aid and CPR Certification
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2002
Resolved 6 September 2002
Fire Fighting › Fire Hoses
Issued 7 August 2002 Resolved
Install fire hoses that meet the requirement of 46CFR181.320 (UL-19 Approved). LEGACY COMPONENT DESC: Condition
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 August 2002
Resolved 6 September 2002
Engineering › Steering Gear System
Issued 7 August 2002 Resolved
Install double nut on the STBD steering linkage at connection to the rudder post. LEGACY COMPONENT DESC: Fastener
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 August 2002
Resolved 6 September 2002
Engineering › Bilge Water Management System
Issued 7 August 2002 Resolved
Install bilge high level alarms 46CFR182.530. LEGACY COMPONENT DESC: High Level Alarm
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2002
Resolved 6 September 2002
Accommodation/Occupational Safety › Ventilation
Issued 7 August 2002 Resolved
Repair emergency ventilation closure. IAW 46CFR182.460. LEGACY COMPONENT DESC: Emergency Closure
Condition: Unknown
Due 14 August 2002
Resolved 6 September 2002
Engineering › Fuel Oil Service System
Issued 7 August 2002 Resolved
Install plugs or caps on the main engine primary fuel filter drains. IAW 46CFR182.455 (3) & (9). LEGACY COMPONENT DESC: Filter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 August 2002
Resolved 6 September 2002
Accommodation/Occupational Safety › Ventilation
Issued 7 August 2002 Resolved
Label emergency ventilation closures. IAW 46CFR185.612. LEGACY COMPONENT DESC: Labeling
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2002
Resolved 6 September 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 7 August 2002 Resolved
Label fixed fire fighting station pull station. IAW 46CFR185.612. LEGACY COMPONENT DESC: Placard
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 August 2002
Resolved 6 September 2002
Operations/Management › Drug and Alcohol Testing
Issued 7 August 2002 Resolved
Provide proof of chemical testing program enrollment. 46CFR16 LEGACY COMPONENT DESC: Proof of Enrollment
Action required: 705 - Other - as specified
Due 14 August 2002
Resolved 6 September 2002
Accommodation/Occupational Safety
Issued 29 October 2001 Resolved
Make repair to stanchion (base) at the vessel entrance on port bow in accordance with 46 CFR 176.802.
Condition: Unknown
Due 29 October 2001
Resolved 29 October 2001
Documentation
Issued 29 October 2001 Resolved
Post COI where visible to passengers in accordance with 46 CFR 176.302.
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Fire Fighting
Issued 29 October 2001 Resolved
Re-install fixed fire system bottle for port engineroom. Vessel must carryand additional BII portable extinguisher outside the port engine compartment until corrected.
Condition: Unknown
Due 29 October 2001
Resolved 29 October 2001
Navigation
Issued 29 October 2001 Resolved
Provide NavRules in accordance with 46 CFR 184.420.
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Documentation
Issued 29 October 2001 Resolved
Provide valid FCC Station License in accordance with 46 CFR 184.502.
Condition: Unknown
Due 28 November 2001
Resolved 27 March 2002
Resolution: Vessel operator provided valid FCC Station License.
Documentation
Issued 29 October 2001 Resolved
Provide correct Marine Radio Operator Permit for [name withheld] in accordance with 47 CFR 80.159.
Condition: Unknown
Due 28 November 2001
Resolved 27 March 2002
Resolution: Vessel operator provided proper marine radio operator''s permit.
Construction/Loadline
Issued 29 October 2001 Resolved
Replace (4) of (6) bolts to the starboard forwardmost chainplate in accordance with 46 CFR 177.330.
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Construction/Loadline
Issued 29 October 2001 Resolved
Properly install the float switch and Ruhl pump in the starboard engine compartment such that the switch cannot be blocked from operating and the pump remains effective in accordance with 46 CFR 176.804(h).
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Electrical
Issued 29 October 2001 Resolved
Replace light covers to bare bulbs in starboard #3 compartment and the portengine compartment in accordance with 46 CFR 183.410(a).
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Engineering
Issued 29 October 2001 Resolved
Replace painted over flame screen for starboard fuel tank in accordance with 46 CFR 182.450(e).
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Engineering
Issued 29 October 2001 Resolved
Provide second hose clamps for generator spoolpiece and generator cooling water intake in accordance with 46 CFR 182.410(d)(1).
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Construction/Loadline
Issued 20 October 2000 Resolved
MARK HULL WITH NAME AND MAILING PORT ON STERN IAW 46 CFR 67.123
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Documentation
Issued 20 October 2000 Resolved
Provide Certificate of Documentation IAW 46 CFR 67.313.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Lifesaving
Issued 20 October 2000 Resolved
PROVIDE PLACARDS AND PROPER INSTALLATION OF LPG (PROPANE GRILL) IAW 46 CFR 177.410.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Deck/Cargo
Issued 20 October 2000 Resolved
PROVIDE ADEQUATE GROUND TACKLE IAW 46 CFR 184.300.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Electrical
Issued 20 October 2000 Resolved
PLACE SAFETY GUARDS OVER GENERATOR BELTS IAW 46 CFR 177.960.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Fire Fighting
Issued 20 October 2000 Resolved
CONDUCT FIRE DRILL IN THE PRESENCE OF A USCG MARINE INSPECTOR IAW 46 CFR 185.524.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Fire Fighting
Issued 20 October 2000 Resolved
REPAIR PRIMARY FIRE PUMP IAW 46 CFR 181.300.(ADEQUATE FIRE MAIN PRESSURE OBTAINED FROM SECONDARY FIRE PUMP WHICH IS PRIMARY BILGE PUMP.)
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Construction/Loadline
Issued 20 October 2000 Resolved
REPAIR AND DEMONSTRATE PROPER WORKING CONDITION OF BILGE HIGH LEVEL ALARM SYSTEM IAW 46 CFR 182.530.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Navigation
Issued 20 October 2000 Resolved
PROVE PROPER OPERATION OF GENERATOR LOW LUBE OIL PRESSURE ALARM. IAW 46 CFR182.530.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Construction/Loadline
Issued 20 October 2000 Resolved
CAP OFF UNUSED THROUGH-HULL FITTING IN STBD #3 COMPARTMENT IAW 46 CFR 176.610.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Construction/Loadline
Issued 20 October 2000 Resolved
CROP AND RENEW BRACING FOR HATCH COAMING FOR #4(ENGINE) COMPARTMENT IAW NVIC 7-95.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Documentation
Issued 20 October 2000 Resolved
RENEW FCC SAFETY CERTIFICATE IAW 46 CFR 184.502
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Documentation
Issued 20 October 2000 Resolved
PROVIDE A FCC MARINE RADIO OPERATOR PERMIT IAW 46 CFR 184.502.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Navigation
Issued 20 October 2000 Resolved
OBTAIN NAVIGATION PUBLICATIONS (TIDE TABLES, CHARTS, COAST PILOT(EXCERPT), LIGHT LIST (EXCERPT)) IAW 46 CFR 184.420.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Lifesaving
Issued 20 October 2000 Resolved
PROVE PROPER OPERATION OF PUBLIC ADDRESS SYSTEM IAW 46 CFR 184.610.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Unknown
Issued 23 September 1999 Resolved
Replace nuts/bolts that are wasted/rusted on moorage cleats (port/stbd, forward bow) IAW; 46 CFR 184.300.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Electrical
Issued 23 September 1999 Resolved
Replace plastic "zip-ties" that support electrical wires/cables (located throughout vessel) with metallic supports IAW; 46 CFR 183.340 (4).
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Electrical
Issued 23 September 1999 Resolved
Provide a light fixture guard/cover to overhead fluorecent light in port head IAW; 46 CFR 183.410.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Construction/Loadline
Issued 23 September 1999 Resolved
Fill/repair hole in generator room bulkhead (port side/forward) to ensure watertight integrity IAW; 46 CFR 171.114 (2).
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Construction/Loadline
Issued 17 March 1999 Resolved
Noted bilge high level alarms have not been installed. Install bilge high level alarms in accordance with 46CFR 182.530 to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Fire Fighting
Issued 17 March 1999 Resolved
Noted fixed fire suppression has not yet been installed. Install fixed fire suppression in accordance with 46CFR 181.400 to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Fire Fighting
Issued 17 March 1999 Resolved
Noted ventilation openings to the engine and generator rooms cannot be secured. Provide a means to secure ventilation in spaces protected by_x001C_ fixed gas fire suppression system in accordance with 46CFR 182.465(h) to the satisfaction of the attendng marine inspector.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Engineering
Issued 29 September 1997 Resolved
INSTALL EXHAUST DUCTING TO THE BILGE AREA OF THE STARBOARD ENGINE ROOM.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Electrical
Issued 29 September 1997 Resolved
EFFECT PERMANENT REPAIRS TO THE PORT MAIN ENGINE STARTER.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Engineering
Issued 29 September 1997 Resolved
INSULATE THE OUTBOARD EXHAUST PIPE ON THE STARBOARD MAIN ENGINE BETWEEN THEENGINE EXHAUST MANIFOLD AND THE POINT OF WATER INJECTION.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Fire Fighting
Issued 29 September 1997 Resolved
EFFECT PERMANENT REPAIRS TO THE PRIMARY FIRE PUMP MOTOR, REMOVE THE RECEPTACLE AND MAKE THE ELECTRICAL CONNECTION TO THE MOTOR PERMANENT.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Lifesaving
Issued 29 September 1997 Resolved
PLACE RETROREFLECTIVE TAPE ON ALL RING LIFE BUOYS.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Engineering
Issued 29 September 1997 Resolved
REPLACE ALL SALT WATER COOLING HOSES ON THE STARBOARD MAIN ENGINE.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Navigation
Issued 29 September 1997 Resolved
INSTALL A COTTER PIN OR SOME OTHER ACCEPTABLE MEANS TO RETAIN THE NUT AND BOLT CONNECTING THE STARBOARD RUDDER ARM TO THE STEERING COLUMN._x001C_ _x001C_ THIS ITEM SHALL BE CORRECTED PRIOR TO THE CARRIAGE OF PASSENGERS._x001C_
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Accommodation/Occupational Safety
Issued 23 September 1996 Resolved
Repair or replace ladders leading to both enginerooms.
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Electrical
Issued 23 September 1996 Resolved
Provide shields for incandescent light bulbs above dance floor on main deck.
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Engineering
Issued 23 September 1996 Resolved
Replace flexible fuel hoses with hoses that meet ASTM D1692 as per 46 CFR 182.20-40(2)(ii).
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Construction/Loadline
Issued 23 September 1996 Resolved
Repair & treat area of termite damage in the starboard MSD space.
Condition: Unknown
Due 14 October 1996
Resolved 14 October 1996
Construction/Loadline
Issued 28 September 1995 Resolved
Make penetration in starboard collision bulkhead watertight in accordance with 46 CFR 171.114.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Electrical
Issued 28 September 1995 Resolved
Repair watertight connection on lower end of circuit breaker in port generator compartment.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Electrical
Issued 28 September 1995 Resolved
Properly dead end wires in port generator compartment.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Construction/Loadline
Issued 28 September 1995 Resolved
Install stuffing tube in watertight bulkhead between fuel tank compartment and port generator room for fuel lines in accordance with _x001C_ 46 CFR 182.20-40(b)(2).
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Construction/Loadline
Issued 28 September 1995 Resolved
Prior to carrying passengers for hire prove proper operation of bilge system.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Fire Fighting
Issued 28 September 1995 Resolved
Relocate portable fire extinguishers to a convenient location outside the protected space and label location (4 each).
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Engineering
Issued 28 September 1995 Resolved
Prove proper operation of port engine water temperature gauge.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Engineering
Issued 28 September 1995 Resolved
Install flame screen drip pans on fuel filters in port and starboard fuel tank compartments in accordance with 46 CFR 182.20-40(5).
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Construction/Loadline
Issued 28 September 1995 Resolved
Label bow and stern with vessel name in accordance with 46 CFR 185.30-1.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Lifesaving
Issued 28 September 1995 Resolved
Label doors to bow with "No passengers allowed while underway".
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Construction/Loadline
Issued 28 September 1995 Resolved
Extend vent ducts to bilge in generator and port engine compartments.
Condition: Unknown
Due 28 September 1995
Resolved 28 September 1995
Unknown
Issued 3 April 1995 Resolved
Remove defunct electrical generator from starboard generator space - disconnect and properly isolate all generator systems - and proprly installsolid ballast weight to adjust for generator removal.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 3 April 1995 Resolved
Repair light in port storage compartment - replace unapprove "wire tie" type wire connectors and replace with approved (UL) pressure crimping wire connectors.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 3 April 1995 Resolved
Clean machinery space bilge system strainers.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 3 April 1995 Resolved
Provide caps for through hull ball valves.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 3 April 1995 Resolved
Repair main deck railing where solid runners have been installed under the 42 inch railing and are deteriorated , renew.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 3 April 1995 Resolved
Make repairs to deck IWO the aft most compartment hatch starboard side - where plywood is rotted and delaminating.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 3 April 1995 Resolved
Repair railing stanchion at starboard forward embarkation station - stanchion is corroded and appears to have a weakened achoring to the deck -repair/renew as original.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 22 September 1994 Resolved
REPAIR TWO LIGHTS IN THE SECOND SPACE AFT OF THE BOW, PORT AND STARBOARD SPONSONS IN ACCORDANCE WITH 46 CFR 176.25-1(a).
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Electrical
Issued 22 September 1994 Resolved
INSTALL JUNCTION BOXES IN PORT AND STARBOARD SPONSONS, FIRST COMPARTMENT THROUGH HULL LIGHTING IN ACCORDANCE WITH 26 CFR 176.25-1(a).
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Lifesaving
Issued 22 September 1994 Resolved
REPLACE RETRO REFLECTIVE TAPE ON 64 ADULT LIFE PRESERVERS IN ACCORDANCE WITH 46 CFR 180.25-25. VESSEL IS RESTRICTED TO 85 ADULT PASSENGERS AND 18 CHILDREN UNTIL IN COMPLIANCE.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Electrical
Issued 22 September 1994 Resolved
REPAIR OR REPLACE AS PER ORIGINAL STARBOARD GENERATOR IN ACCORDANCE WITH_x001C_ 46 CFR 176.10-5(b).
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Lifesaving
Issued 22 September 1994 Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Engineering
Issued 22 September 1994 Resolved
PERMANENTLY STENCIL LOCATION OF THE PORT FUEL OIL SHUTOFF VALVE IN_x001C_ ACCORDANCE WITH 46 CFR 185.30-20.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Engineering
Issued 22 September 1994 Resolved
INSTALL VENT SCREENS, 30X30 MESH, PORT AND STARBOARD FUEL OIL TANKS IN ACCORDANCE WITH 46 CFR 182.20-35. VESSEL IS RESTRICTED UNTIL IN COMPLIANCE.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Construction/Loadline
Issued 22 September 1994 Resolved
PLUG THROUGH HULL OPENINGS IN ACCORDANCE WITH 46 CFR 176.25-1(a).
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Engineering
Issued 10 July 1991 Resolved
INSTALL TUBING (MIN. .035 WALL THICKNESS) TO WITHIN 3FT. OF PORT GENERATOR.
Condition: Unknown
Due 10 July 1991
Resolved 10 July 1991
Electrical
Issued 10 July 1991 Resolved
INSTALL A GUARD OVER THE BRUSH UNIT ON STBD GENERATOR.
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Fire Fighting
Issued 10 July 1991 Resolved
CORRECTLY LABEL THE EMERGENCY FUEL CUT OFF VALVES
Condition: Unknown
Due 10 July 1991
Resolved 10 July 1991
Construction/Loadline
Issued 10 July 1991 Resolved
PROVE THE PROPER OPERATION OF THE HAND BILGE PUMP
Condition: Unknown
Due 10 July 1991
Resolved 10 July 1991
Deck/Cargo
Issued 10 July 1991 Resolved
TIGHTEN ALL MAST STAYS
Condition: Unknown
Due 9 August 1991
Resolved 9 August 1991
Construction/Loadline
Issued 4 October 1989 Resolved
FUMIGATE VESSEL (IN ACCORDANCE WITH FEDERAL AND STATE REQUIREMENTS)
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
UNSTEP MASTS TO PERMIT INSPECTION FOR TERMITE INFESTATION.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
PROVIDE PROPOSAL TO RENEW ALL TERMITE INFESTED WOOD TO ORIGINAL SCANTLINGS.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
PROVIDE COMPREHENSIVE, DETAILED PLAN (INCLUDING TIMELINE) TO ACCOMPLISH ALL ABOVE ITEMS.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Engineering
Issued 4 October 1989 Resolved
RENEW ALL HOSE OVERBOARD CLAMPS IN ENGINE ROOM.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
REMOVE STANCHION, CENTER LINE, DIRECTLY FORWARD OF BAR, AND SURROUNDING COLLAPSED DECK TO PERMIT INSPECTION OF AREA TO DETERMINE CAUSE AND EXTENT.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
ON WING, IN GENERAL: RENEW ALL WOOD AT THROUGH HULL FITTINGS AS REQUIRED. RENEW WING COVERING TO ORIGINAL.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
MAKE SEA STRAINERS AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Accommodation/Occupational Safety
Issued 4 October 1989 Resolved
IN PORT AND STARBOARD AFT COMPARTMENTS: SANITIZE COMPARTMENTS. THIS IS TOINCLUDE REMOVAL OF ALL TOILET PAPER AND WASTE PRODUCTS FROM COMPARTMENTS.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Accommodation/Occupational Safety
Issued 4 October 1989 Resolved
REMOVE ALL OIL SOAKED CARPET ON MAIN DECK.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
REMOVE ALL OIL SOAKED WOOD FROM MAIN DECK.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
RENEW ALL OIL/WATER SOAKED DECKING UNDER CARPET/FLOORING OF MAIN DECK.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
RENEW DECKING, STARBOARD HULL, FORWARD COMPARTMENT, FOREPEAK, IN WAY OF MANHOLE TO THE EXTENT NECESSARY TO FIND SATISFACTORY MATERIAL.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
RENEW DECKING, PORT HULL, FORWARD COMPARTMENT, FOREPEAK IN WAY OF RIPPED OUT BITT, TO THE EXTENT NECESSARY TO FIND SATISFACTORY MATERIAL.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
ON DECK WING AREA FORWARD OF ENCLOSURE, DETERMINE CONDITION OF DECK UNDER GLASS MATTING AND PROVIDE PROPOSAL FOR REPAIR.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
REMOVE EXTERIOIR HULL COATING (PAINT) TO ALLOW FOR INSPECTION OF GLASS COATING.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Accommodation/Occupational Safety
Issued 4 October 1989 Resolved
SUBMIT PROPOSED PLANS FOR REVIEW/APPROVAL FOR MARINE SANITATION SYSTEM FOR VESSEL.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
IN ENGINE COMPARTMENT, REMOVE OILY WATER FROM BILGES.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
IN COMPARTMENT AFT OF PORT HULL ENGINE ROOM, REMOVE OILY FILM FROM.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
PROVIDE DOCUMENTATION PROVING THATCH HUT MATERIAL IS FIRE RETARDANT. IF UNABLE TO PROVIDE, REMOVE THATCH HUT MATERIAL.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
ON EXTERIOR OF STARBOARD HULL,DETERMINE CAUSE FOR VARIOUS HULL BLISTERS ANDPROVIDE PROPOSAL FOR REPAIRS.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
ON EXTERIOR OF PORT HULL, DETERMINE CALUSE FOR VARIOUS HULL BLISTERS AND PROVIDE PROPOSAL FOR REPAIRS.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Engineering
Issued 4 October 1989 Resolved
REMOVE CUTLASS BEARING STRUT FOR INSPECTION HULL KEEL (PORT).
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
ON WING AREA, LEADING EDGE FORWARD AND LOWER EDGE: DETERMINE CAUSE FOR EXTERIOR SEPARATION FROM FRAMING. REMOVE ALL WATER LOGGED/ROTTEN WOOD. RENEW TO ORIGINAL SCANTLINGS.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 4 October 1989 Resolved
ON WING UNDERBODY, EXTERIOR: REMOVE ALL WATER LOGGED FIBERGLASS CLOTH. RENEW, AS REQUIRED, PLYWOOD HULL. RENEW ALL WING FASTENINGS.
Condition: Unknown
Due 4 October 1989
Resolved 4 October 1989
Construction/Loadline
Issued 12 September 1989 Resolved
VESSEL IS PROHIBITED FROM CARRYING PASSENGERS FOR HIRE UNTIL A SATISFACTORYCREDIT HULL EXAMINATION IS COMPLETED TO THE SATISFACTION OF THE [name withheld], HI.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Accommodation/Occupational Safety
Issued 12 September 1989 Resolved
PLACE BOTH HEADS INTO FULL COMPLIANCE WITH THE USCG MARINE SANITATION REGU-LATIONS (33 CFR PART 159). OVERBOARD DISCHARGE FROM A HOLDING TANK IS PRO-HIBITED SINCE VESSEL'S ROUTE IS IN A NO DISCHARGE ZONE.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Engineering
Issued 12 September 1989 Resolved
REMOVE ALL OIL FROM ENGINE ROOM BILGES AND THE PORT RUDDER COMPARTMENT.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Navigation
Issued 12 September 1989 Resolved
TIGHTEN THE BOLTS ON THE PORT AND STARBOARD RUDDER ARMS.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 12 September 1989 Resolved
REPLACE THE BATTERY BOX IN THE PORT ENGINE ROOM.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Accommodation/Occupational Safety
Issued 12 September 1989 Resolved
REMOVE ALL HUMAN WASTE MATERIAL FROM THE COMPARTMENT BELOW THE STARBOARD HEAD.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Construction/Loadline
Issued 10 February 1989 Resolved
RE-PAINT VESSEL'S NAME ON PORT AND STARBOARD BOW IN COLORS CONTRASTING TO BACKGROUND. RE-PAINT VESSEL'S NAME ON STERN IN COLOR CONTRASTING TO BACKGROUND.
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Construction/Loadline
Issued 10 February 1989 Resolved
POST COAST GUARD STABILITY LETTER ON BRIDGE UNDER GLASS.
Condition: Unknown
Due 10 February 1989
Resolved 10 February 1989
Engineering
Issued 12 February 1988 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Engineering
Issued 12 February 1988 Resolved
REPAIR INSULATION ON THE PORT MAIN ENGINE INBOARD EXHAUST MANIFOLD.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Navigation
Issued 12 February 1988 Resolved
PROVIDE VESSEL HORN.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Navigation
Issued 12 February 1988 Resolved
REPLACE BOTH NAVIGATION RUNNING LIGHTS WITH APPROVED TYPE.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Lifesaving
Issued 12 February 1988 Resolved
RENEW REFLECTIVE TAPE AS REQUIRED ON ALL ADULT AND CHILD PFD'S.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Documentation
Issued 12 February 1988 Resolved
RENEW VESSELS CERTIFICATE OF DOCUMENTATION, WITH CHANGE OF OWNER AND ADDRESS.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Engineering
Issued 12 February 1988 Resolved
INSTALL 30" X 30" FLAME SCREEN ON BOTH FUEL TANK VENTS.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Fire Fighting
Issued 12 February 1988 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Electrical
Issued 3 December 1987 Resolved
REPLACE WATER PUMP DRIVE BELT ON STARBOARD GENERATOR, INSTALL A PROPER SIZED BELT AND REINSTALL PROTECTIVE GUARD.
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Engineering
Issued 3 December 1987 Resolved
REPLACE FLEXIBLE FUEL HOSES ON PORT GENERATOR DIESEL WITH COAST GUARD APPROVED FLEXIBLE FUEL HOSES.
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Electrical
Issued 3 December 1987 Resolved
PROPERLY SECURE OR REMOUNT ELECTRICAL SWITCH/TERMINAL BOARDS IN BOTH ENGINECOMPARTMENTS AND THE PORT GENERATOR COMPARTMENT.
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Construction/Loadline
Issued 3 December 1987 Resolved
CROP AND RENEW DRY ROT AREA 8"X8" AND SECTION OF TRANSVERSE 2"X9" FRAME IN THE PORT AFT COMPARTMENT OVERHEAD.
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Engineering
Issued 3 December 1987 Resolved
INSTALL GROUND STRAPS ON BOTH FUEL TANK FILL LINES IN WAY OF THE RUBBLE COUPLINGS.
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Construction/Loadline
Issued 3 December 1987 Resolved
HAVE THE PORT FORWARD COMPARTMENT TREATED FOR TERMITE INFESTATION AND PROVIDE COPY OF INVOICE OR REPORT TO THE [name withheld].
Condition: Unknown
Due 3 December 1987
Resolved 3 December 1987
Unknown
Issued 28 February 1986 Resolved
EFFECT A STRUCTURALLY WATERTIGHT REPAIR TO THE IMPROPERLY REPAIRED ORIGINALEXIT HOLES FOR THE MSD SYSTEMS, P&S HULLS, LOCATED ON THE INBOARD SECTION OF THE CROSS HULL BOTTOM PLATE, ADJACENT TO THE STERN MOST COMPARTMENT.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Fire Fighting
Issued 6 March 1985 Resolved
INSTALL PRESSURE GAUGES ON FIRE PUMP DISCHARGES.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Engineering
Issued 6 March 1985 Resolved
FIX NEW FUEL HOSE BULKHEAD PENETRATIONS WATERTIGHT.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Accommodation/Occupational Safety
Issued 6 March 1985 Resolved
RENEW ALL MACHINERY SPACE LOWER BILGE VENT ELBOWS.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985 Resolved
RENEW PORT ENGINE ROOM BATTERY BOX.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985 Resolved
REPAIR STARBOARD GENERATOR EXHAUST HEAT EXCHANGER.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985

Casualty record · 1

1 April 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2326271
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.