MAURY USCG vessel records Sign in
← All vessels

KAITLYN EYMARD

KAITLYN EYMARD is a 2002 offshore supply vessel. The Coast Guard has recorded 16 inspections since 2002, most recently in October 2008, along with 10 deficiencies and 1 casualty investigation in 2009.

Records from 2002 to 2009. Most recent: casualty investigation, 29 May 2009.

Built
2002
Last inspected
13 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8765060 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA9144
513440
Flag
UNITED STATES
366861890 (licence lapsed)
Maury page id
psix-513440

Inspections, by type

…with no type recorded3
Years with a record 6 calendar years (2002–2008)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it228 - Convention (Subpart B), Net Ton
132 - Regulatory (Subpart C or D), Net Ton
761 - Convention (Subpart B), Gross Ton
194 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA9144MMSI 366861890 · expired · compulsorily equipped · granted 16 July 2002, cancelled 15 September 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 16

13 October 2008 MTSA Verification · Ballast Water Examination · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3343891
1 October 2008 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3336485
27 February 2008 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3162190
18 July 2006 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2717196
14 June 2005 Hull Examination · MTSA Verification · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2390478
8 October 2004 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2217604
20 August 2004 Re-Inspection · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2171495
11 December 2003 Deficiency Check · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1962338
4 September 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1896440
5 May 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1792014
2 March 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1753324
18 January 2003 Damage Survey · Examination of Repairs
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1734927
16 January 2003 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1731510
13 December 2002 Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1718270
19 July 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1648776
28 March 2002 Initial Certification · Inclining Experiment · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1598523

Deficiency record · 10

Construction/Loadline › Structures › Manhole
Issued 20 August 2004 Resolved
Permanently attach manhole covers IWO all flushdeck scuttles IAW 46 CFR 42.15-40(a).
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 8 October 2004
Resolution: Installed chains
Accommodation/Occupational Safety › Occupational Safety
Issued 4 September 2003 Resolved
Make permanent repairs to fractured welds on upper and lower ends of ladder leading from 01 deck to 02 deck port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 31 December 2003
Resolution: Permanent repairs complete.
Construction/Loadline › Hull
Issued 4 September 2003 Resolved
Make permanent repairs as original to bottom and side shell in-set in #1 & 2 stbd water ballast tank in way of chine. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 31 December 2003
Resolution: Permanent repairs complete.
Electrical › Electrical Distribution System (service)
Issued 4 September 2003 Resolved
Renew indicator bulbs and prove proper operation of Bus B ground detection system on 460 volt panel in engine room. LEGACY COMPONENT DESC: Ground Detection
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 31 December 2003
Resolution: Electrical work completed.
Construction/Loadline › Structures
Issued 4 September 2003 Resolved
Renew as original broken window/frame on forward superstructure 01 deck amidships, in way of crew lounge. LEGACY COMPONENT DESC: Superstructure
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 31 December 2003
Resolution: Repairs completed.
Pollution Prevention/Response › Prevention Equipment
Issued 18 January 2003 Resolved
Due to freeze damage on chlorinator bottles on end of MSD, Prior to using MSD, for other than as a Type III (Holding Tank), make proper repairs to chlorinators. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 4 September 2003
Resolution: Examined and found satisfactory.
Operations/Management › Pollution
Issued 18 January 2003 Resolved
Due to freeze damage on weld, Make permanent repairs to sewage drain line on portside of house. LEGACY COMPONENT DESC: Control of Discharge of Sewage
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 4 September 2003
Resolution: Examined MSD and found satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 13 December 2002 Resolved
Make temproary repairs to 3 cracks found in port side shell in way of #3 wing ballast tank.
Action required: 705 - Other - as specified
Due 20 December 2002
Resolved 14 December 2002
Resolution: Examined and found satisfactory welding and mag particle results for temporary repairs.
Construction/Loadline › Hull
Issued 13 December 2002 Resolved
Make permanent repairs to 3 cracks found in port side shell in way of #3 wing ballast tank. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 31 December 2003
Resolution: Permanent repairs complete.
Engineering › Steering Gear System
Issued 18 July 2002 Resolved
Provide approved plans, and comply with the requirements outlined in 46 CFR 58.25-70 as discussed in MSC letter E2-0202157 dated 27JUN02. LEGACY COMPONENT DESC: Feedback Unit
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 January 2003
Resolved 16 January 2003
Resolution: Installed and tested dual follow-up steering amplifiers, feedback and full follow-up units.

Casualty record · 1

29 May 2009Routine · role: Involved in a Marine Casualty · activity 3489566
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.