Records from 1984 to 1997. Most recent: inspection, 29 May 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
29 May 1997
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1108032
1 June 1996
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1085464
18 April 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1079851
26 March 1996
Examination of Repairs · Damage Survey
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1082879
29 February 1996
Examination of Repairs
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1077442
22 February 1996
Damage Survey
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1353870
17 January 1996
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 873027
22 December 1995
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1186607
22 December 1995
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1186608
13 October 1995
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1189749
3 October 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 692246
10 October 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 689559
15 September 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 370570
12 August 1994
Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 862681
17 July 1994
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1178438
29 June 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 689560
1 December 1993
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 851275
1 October 1993
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1149807
18 March 1993
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1143826
4 November 1992
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 947622
8 September 1992
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1249655
13 July 1992
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 948950
10 December 1991
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1256077
29 September 1991
Re-Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1247275
2 April 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 342855
6 July 1989
COI Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1240658
5 August 1988
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1343553
9 June 1987
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1009529
14 January 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1315306
18 October 1985
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1309255
8 October 1985
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 990627
23 April 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 983765
14 January 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1298483
23 November 1984
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1288314
Construction/Loadline
Issued 22 February 1996
Resolved
Prior to leaving Rota, all side longitudinals, stiffeners, brackets with eroded or missing weldment shall be stitch/chain welded as original design in way of machinery space, holds, voids and hatch areas to the satisfactionof the attending CG inspector.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Navigation
Issued 22 February 1996
Resolved
All bolts in steering gear control assembly in way of steering gear compartment shall be double nutted and/or drilled with cotter key installedin way of nut(s), prior to departure.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Deck/Cargo
Issued 22 February 1996
Resolved
Vessel cargo hold shall be examined at regular intervals daily for weeping or excess water in area of damage in way of cargo hold due to failure of temporary repairs until vessel is upon drydock facility. Any such evidence of failure or other means of water seapage, OCMI to be notified immediately
Condition: Unknown
Due 1 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 22 February 1996
Resolved
Engine and components are to be monitored at regular intervals, during operation, for indication of overheating, due to any factors, for reasons of slight impingement of keel coolers due to grounding damage. Any repairs deemed necessary shall be evaluated/performed at drydock exam.
Condition: Unknown
Due 1 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 22 February 1996
Resolved
12 volt jury-rigged light in living space to be removed or properly installed and replaced with approved mounted fixture prior to departure.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 22 February 1996
Resolved
Satisfactory seatrial to be performed prior to departure for next porrt of call and witnessed by attending CG inspector.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Unknown
Issued 22 February 1996
Resolved
All flamable/combustibal materials to be removed from vessel prior to departure.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Engineering
Issued 22 February 1996
Resolved
Damage to hull in way of keel coolers, midship ballast tank, hold bottom and associated plates and stiffeners to be addressed at next drydock exam for repair.
Condition: Unknown
Due 1 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 22 February 1996
Resolved
Machinery space lamp to be installed with proper glass and cage protection.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Unknown
Issued 22 February 1996
Resolved
Proper US citizen compliment as shown on COI (3 to include 1 US master, 2 US deckhands) to be verified by attending CG inspector.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 22 February 1996
Resolved
Small holes in forepeak deck and manhole coamings to be welded as a temporary repair prior to departure.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Documentation
Issued 22 February 1996
Resolved
Locate original Certificate of Documentation or apply for and obtain duplicate of COD and once received to be permanently displayed upon vessel and CG OCMI notified.
Condition: Unknown
Due 1 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 22 February 1996
Resolved
A complete survey by ultrasound or similar procedure to be performed in thepresents of a CG inspector and report provided for evaluation/replacement of hull/deck plating at time of drydock exam.
Condition: Unknown
Due 1 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 22 February 1996
Resolved
An underwater survey with photos to be performed in the presents of CG inspector prior to departure.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 22 February 1996
Resolved
Centerline ballast tank, adjacent compartments and hatch area to be opened,cleared, aired, made available for entry and examined by attending CG inspector prior to departure.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Construction/Loadline
Issued 22 February 1996
Resolved
Prior to departure Rota, watertight collision bulkhead shall be welded continuously 100%, both sides where fitted at deck and bulkhead to be verified by attending CG inspector.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Navigation
Issued 22 February 1996
Resolved
Prior to departure, repack/tighten rudderstock assembly due to excessive weeping from grounding.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 22 February 1996
Resolved
Replace/repair interior hatch to engine space in way of living space, priorto departure.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Accommodation/Occupational Safety
Issued 13 October 1995
Resolved
Properly stow all gas bottles (oxygen, acyetelene, etc) for sea.
Condition: Unknown
Due 16 October 1995
Resolved 19 October 1995
Electrical
Issued 13 October 1995
Resolved
Research procedures to conduct overspeed trip, high jacketwater temperatureand low oil pressure shutdown tests on generator drive engine.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Electrical
Issued 13 October 1995
Resolved
Install missing globes in various lighting fixtures thruout vessel missing such globes.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Accommodation/Occupational Safety
Issued 13 October 1995
Resolved
Lable/mark "Emergency Exit, Keep Clear" at engineroom emergency exit on main deck.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Lifesaving
Issued 13 October 1995
Resolved
Install weak link of proper size on life float.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Engineering
Issued 13 October 1995
Resolved
Install flame impingement bowls on RACOR fuel oil filters.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Navigation
Issued 13 October 1995
Resolved
Readjust bulbs in port and stern running lights to have filiment from bulb within convex portion of lens.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Navigation
Issued 13 October 1995
Resolved
Obtain copy of Rules Of The Road, maintain on bridge.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Documentation
Issued 13 October 1995
Resolved
Obtain, and maintain on vessel, a copy of Code of Federal Regulations, sub-chapter "I", 46 CFR 90-139
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Electrical
Issued 13 October 1995
Resolved
Make repairs to lighting in pilothouse.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Navigation
Issued 13 October 1995
Resolved
Remove paint and caulking from port and starboard navigation running light lens.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Deck/Cargo
Issued 13 October 1995
Resolved
Replace weathered and chaffed hydraulic hose to bow mooring winch actuator.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Electrical
Issued 13 October 1995
Resolved
Provide permanent wiring for cargo deck light located above pilothouse. Allwire to be of approved and of one piece, or if spliced, splices shall be inside approved electrical box.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Fire Fighting
Issued 13 October 1995
Resolved
Lable hose station on main deck.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Navigation
Issued 13 October 1995
Resolved
Post emergency steering instructions, instructions to cover procedures to take to shift to/from emergency mode, along with such commands that will beused to relay steering instructions.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Electrical
Issued 13 October 1995
Resolved
Replace missing "pecker head" from deck crane hydraulic motor, allowing electrical motor/line cable connections to be exposed.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Install missing valve hand wheels on bilge/ballast system manifold valves, located forward portside, engineroom.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Engineering
Issued 13 October 1995
Resolved
Reseaech procedures to conduct overspeed and shutdown tests on main engine.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Lable all bilge/ballast valves on manifold, forward portside engineroom.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Post diagram of bilge and ballst system in area of mainfold.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Accommodation/Occupational Safety
Issued 13 October 1995
Resolved
Remove dunnage and scrap from deck working areas, stow material properly.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Engineering
Issued 13 October 1995
Resolved
Install 30 x 30 mesh flame screen in fuel oil tank vents.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Deck/Cargo
Issued 13 October 1995
Resolved
Perform load test on crane and associated cable.
Condition: Unknown
Due 1 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 13 October 1995
Resolved
Clear emergency exit from engineroom to main deck.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Leak test welds on new plate installed main deck aft port side, in way of the overhead of the port fuel oil tank.
Condition: Unknown
Due 1 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 13 October 1995
Resolved
Replace cracked window on bridge.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Repair corroded area in way of port refer space hatch cover.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Accommodation/Occupational Safety
Issued 13 October 1995
Resolved
Install safety chains between fixed rails port and starboard main deck, midbody area.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Make necessary repair to port bridge wing hatch to allow hatch to secure properly.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Unknown
Issued 13 October 1995
Resolved
Mark vessel name along with lifefloat capacity on vessel lifefloat.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Replace missing gasket material stbd bridge wing hatch/door.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Electrical
Issued 13 October 1995
Resolved
Make repairs to lighting fixture located above starboard upper berth.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Maintain a good coat of marine paint on foredeck area of vessel, as per recommendation of survey conducted on/about 31JAN95, report dated 09FEB95.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Navigation
Issued 13 October 1995
Resolved
Paint stern light shield FLAT black.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Engineering
Issued 13 October 1995
Resolved
Install guard over engine pullys, fwd on propulsion engine.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Correct knife edging on forward hold hatch combing.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Deck/Cargo
Issued 13 October 1995
Resolved
Replace chain on anchor.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Repair broken and correded hinges on bow compartment hatch.
Condition: Unknown
Due 1 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 October 1995
Resolved
Service EPIRB, test light will not activate during test precedures.
Condition: Unknown
Due 16 October 1995
Resolved 19 October 1995
Lifesaving
Issued 13 October 1995
Resolved
Untie life float from cradle, life float to be able to float free.
Condition: Unknown
Due 16 October 1995
Resolved 19 October 1995
Fire Fighting
Issued 13 October 1995
Resolved
Have all portable fire extinguishers undergo annual servicing.
Condition: Unknown
Due 16 October 1995
Resolved 19 October 1995
Construction/Loadline
Issued 13 October 1995
Resolved
Provide MSO Guam with results of ultrasonic testing done to vessel foredeckper recommendations survey conducted on/about 31JAN95, report dated 9FEB95.If re-test was not completed in July95, than re-test shall be accomplished no later than 30NOV95, with results received MSO Guam no later than 10DEC95
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Lifesaving
Issued 13 October 1995
Resolved
Replace broken oar from life float.
Condition: Unknown
Due 16 October 1995
Resolved 19 October 1995
Fire Fighting
Issued 13 October 1995
Resolved
Troubleshoot low firefighting water discharge pressure from electrical firepump.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Deck/Cargo
Issued 13 October 1995
Resolved
Resecure bow mooring winch to deck, replace missing bolts.
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Construction/Loadline
Issued 12 August 1994
Resolved
Perform ultra sonic testing of foredeck forward of main cargo hatch. Alternate gauging method will be considered.
Condition: Unknown
Due 12 August 1994
Resolved 12 August 1994
Navigation
Issued 13 July 1992
Resolved
REPAIR SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 13 July 1992
Resolved 13 July 1992
Lifesaving
Issued 13 July 1992
Resolved
INSTALL CG APPROVED WATER LIGHT ON LIFEFLOAT.
Condition: Unknown
Due 13 July 1992
Resolved 13 July 1992
Lifesaving
Issued 13 July 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 July 1992
Resolved 13 July 1992
Deck/Cargo
Issued 13 July 1992
Resolved
INSTALL PROPER HYDRAULIC HOSE ON DECK BOOM.
Condition: Unknown
Due 13 July 1992
Resolved 13 July 1992
Documentation
Issued 29 September 1991
Resolved
PROVIDE VALID FCC STATION LICENSE.
Condition: Unknown
Due 29 September 1991
Resolved 29 September 1991
Documentation
Issued 29 September 1991
Resolved
PROVIDE VALID RADIOTELEPHONE SAFETY CERTIFICATE.
Condition: Unknown
Due 29 September 1991
Resolved 29 September 1991
Engineering
Issued 29 September 1991
Resolved
INSTALL DRIP PANS UNDER RACOR FUEL FILTERS IN ENGINE ROOM.
Condition: Unknown
Due 29 September 1991
Resolved 29 September 1991
Accommodation/Occupational Safety
Issued 29 September 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF THE TYPE III MSD.
Condition: Unknown
Due 29 September 1991
Resolved 29 September 1991
Lifesaving
Issued 8 October 1985
Resolved
PROVIDE 10 ADULT AND 2 CHILD'S LIFE PRESERVERS. UNTIL SUCH TIME AS ABOVE PFD'S ARE PLACED ON BOARD, NO CHILDREN ARE PERMITTED AND NO MORE THAN 10 ADULTS SHALL BE CARRIED.
Condition: Unknown
Due 8 October 1985
Resolved 8 October 1985
Lifesaving
Issued 23 November 1984
Resolved
PROVIDE ADDITIONAL LIFE PRESERVERS: 10 ADULT, 2 CHILD. VESSEL IS LIMITED TO 10 PERSONS ON BOARD.
Condition: Unknown
Due 23 November 1984
Resolved 23 November 1984
Engineering
Issued 23 November 1984
Resolved
HYDRO TEST FUEL TANKS TO 5 PSI.
Condition: Unknown
Due 23 November 1984
Resolved 23 November 1984
Fire Fighting
Issued 23 November 1984
Resolved
PROVIDE A 50 FT. 1 1/2" HOSE AND MINIMUM 50 PSI FIRE MAIN SYSTEM PRIOR TO CARRYING FLAMMABLE OR EXPLOSIVE CARGO.
Condition: Unknown
Due 23 November 1984
Resolved 23 November 1984