MSC MEXICO V is a 2002 freight ship. The Coast Guard has recorded 21 inspections since 2016, most recently in December 2025, along with 10 deficiencies and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 20 December 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it53453 - Convention (Subpart B), Gross Ton 33604 - Convention (Subpart B), Net Ton 86597 - Displacement, Ton 66597 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 21
20 December 2025PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8285857
21 September 2025Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8241361
20 September 2025Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8238793
18 June 2025PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8159443
13 June 2025PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8158570
12 June 2025Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8158017
11 March 2025Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8090600
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 March 2025Resolved
The fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed unapproved installed electrical installation passing through an A-classed bulkhead, the installation does not meet the requirements for an A-classed boundary.
74solas(01)9.1.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2025
Resolution: Changed to a Code 40ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2024Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. EXCESSIVE OIL LEAK FOUND COMING GOVERNOR ON NUMBER TWO GENERATOR. SOLAS II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 May 2024
Resolution: RCVD class report attesting to governor replacement. No leaks observed after replacement.
ALL THE STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION DURING OPERATIONAL TEST ON THE NUMBER TWO STEERING HYDRAULIC PUMP, A PORT DRIFT OF 3.5 DEGREES PER MINUTE OCCURED. SOLAS II-1/29.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 May 2024
Resolution: Recieved class report attesting to repairs of internal hydraulic oil leak causing drift.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2022Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that they ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard.
While attempting to depart Houston vessel experienced a loss of propulsion of the main engine due to loss of start air pressure.
74 SOLAS (14) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2022
Resolved 12 July 2022
Resolution: Received class report attesting to satisfacotry repairs and engine test.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 14 April 2022Resolved
All Ships of 500 gross tonnage and upwards shall, in addition to meeting the requirements of paragraph 2.3, with the exception of paragraph 2.3.3 and 2.3.5 and the requirements of paragraph 2.4 have: .1 a gyro compass, or other means, to determine and display their heading by shipborne non-magnetic means, being clearly readable by the helmsmen at the main steering position.
Vessel reported that the port side gyro compass repeater is inoperable.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2022
Resolved 8 December 2022
Resolution: RECEIVED REPORT ATTESTING TO REPAIRS.
After any survey of the ship under regulatons 7, 8, 9 or 10 has been completed, no changes shall be made in the structural arrangments, machinery, equipment and other items covered by the survey, without the sanction of the administration. 04 windows removed from superstructure and replaced with window A/C units altering the structural arrangment of the vessel.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 October 2021
Resolution: PSC LA/LB received a class report from NKK satisfying the requirement.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 31 August 2021Resolved
Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily service tank situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occuring in the space in which such tanks are situated. PSCO observed crew unable to shutoff valve to emergency generator fuel tank from outisde the space. After making adjustments to cable, crew was able to successfully secure valve from outside of the space.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 August 2021
Resolved 31 August 2021
Resolution: PSCO Witnessed successful operation of remote cutoff for emergency generator.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 28 September 2017Resolved
0750; 74SOLAS(01)II-2/51; 10(c); HOLD-BACK HOOKS NOT SUBJECT TO CENTRAL CONTROL STATION RELEASE ARE PROHIBITED. 02 SELF CLOSING "A" CLASS DOORS IN THE GALLEY HAD HOLD-BACK HOOKS ON THEM. CREW REMOVED THE HOLD-BACK HOOKS.
Action required: 705 - Other - as specified
Resolved 28 September 2017
Resolution: CREW REMOVED HOLD-BACK HOOKS.
0750; 74SOLAS(01)II-2/51; 10(c); WHERE GASEOUS FUEL IS USED FOR DOMESTIC PURPOSES THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE FUEL SHALL BE SUCH THAT, HAVING REGARD TO THE HAZARDS OF FIRE AND EXPLOSION WHICH THE USE OF SUCH FUEL MAY ENTAIL, THE SAFETY OF THE SHIP AND THE PERSONS ON BOARD IS PRESERVED. MULTIPLE IGNITION SOURCES WERE IN CLOSE PROXIMITY TO FLAMMABLE MATERIALS IN FORWARD BOSUN STORE. CREW REMOVED THE IGNITION SOURCES.
Action required: 705 - Other - as specified
Resolved 28 September 2017
Resolution: CREW REMOVED IGNITION SOURCES.
Lifesaving › Lifeboat › Markings
Issued 28 September 2017Resolved
0610; 74SOLAS(14)III/34 LSA CODE: 4.4.9.3; 10(c); MEANS OF IDENTIFYING THE SHIP TO WHICH THE LIFEBOAT BELONGS AND THE NUMBER OF THE LIFEBOAT SHALL BE MARKED IN SUCH A WAY THAT THEY ARE VISIBLE FROM ABOVE. BOTH PORT AND STARBOARD SIDE LIFEBOATS WERE NOT NUMBERED. CREW PROPERLY MARKED BOTH LIFEBOATS.
Action required: 705 - Other - as specified
Resolved 28 September 2017
Resolution: CREW PROPERLY MARKED BOTH LIFEBOATS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.