Records from 1982 to 2021. Most recent: inspection, 15 January 2021.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2020
No resolution recorded
no repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. The procedures to be followed in notifying the Coast Guard about vessel repairs vary according to the type of vessel and service in which engaged. Vessel owner/operator notified CG that the vessel suffered damage due to Hurricane Sally in accordance with applicable regulatory cite. Vessel must make permanent repair/alteration to the satisfaction of the OCMI in accordance with 46 CFR 176.700(a).
Action required: 705 - Other - as specified
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2020
Resolved
Vessel day time running light was inoperable. All vessels must have nav lights in compliance with inland nav rules.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Provided pictures of operable nav light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 May 2020
Resolved
Generator fuel lines must be complete with factory-assembled end fittings required. Fuel lines were not properly secured per regulations to gen-set.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Provided pictures of approved factory assembled hose fittings.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2020
Resolved
Electrical panel had exposed coverings. Electrical equipment must be installed to protect crew from electrical hazards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Covered exposed wires in electrical panel, provided pictures showing proof.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2020
Resolved
Bond wire for fuel tank was not properly grounded to vessel. All fuel tanks must be electrically bonded to a common ground.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 14 May 2020
Resolution: Bonded loose fuel tank wires to grounding point. Provided satisfactory pictures to MI.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 8 October 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire. Noted that the main engines, generator was due for maintanence. Maintenance machinery and clean bilges to prevent fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal, vessel rectified all prior deficiencies to the satisfaction of the attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 October 2019
Resolved
Repairs or alternative to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Noted that there was a hole in a plank below the waterline in the forward compartment allowing water to actively ingress into the space. Provide repair plan for approval by Sector Mobile OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel O/O and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
Electrical equipment must be installed and maintained to protect passengers and crew from hazards, fire, and shock. Multiple deadend wires found throughout the vessel. Remove all deadend wires or place in appropriate junction box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE OFFICER IN CHARGE, MARINE INSPECTION. NOTED NO COVER FOR THE FORWARD OUTLET IN THE ENGINE ROOM OR TWO OVERHEAD OUTLETS IN THE GALLEY. INSTALL AND PROPERLY SECURE COVERS FOR ELECTRICAL OUTLETS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
ELECTRICAL EQUIPMENT MUST BE INSTALLED AND MAINTAINED TO PROTECT PASSENGERS AND CREW FROM HAZARDS, FIRE, AND SHOCK. NOTED OPEN GROUND IN ENGINE ROOM OUTLET AND IN THE WHEELHOUSE. REWIRE IAW WITH 46 CFR 183.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 October 2019
Resolved
VESSEL MUST CARRY ADEQUATE AND UP TO DATE CHARTS FOR INTENDED VOYAGE. VESSEL DOES NOT HAVE CURRENT NAV CHARTS FOR ROUTE AND AREA. UPDATE NAV CHARTS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 October 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE OFFICER IN CHARGE, MARINE INSPECTION. CIRCUIT BREAKER NOT LABELED. PROPERLY LABEL CIRCUIT BREAKER.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 October 2019
Resolved
EACH ITEM OF SURVIVAL CRAFT EQUIPMENT MUST BE OF GOOD QUALITY, AND EFFICIENT FOR THE PURPOSE IS IS INTENDED TO SERVE. NOTED LIFE FLOAT WAS IN DETERIORATED CONDITION.
REPAIR OR REPLACE IAW 46 CFR 160.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 October 2019
Resolved
THE NAME OF A VESSEL MUST BE MARKED OR PAINTED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH RING LIFE BUOY. NOTED THAT NAME WAS NOT LEGIBLE ON RING LIFE BUOY.RELABEL RING LIFE BUOY.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 8 October 2019
Resolved
AN EAP TRAINING PROGRAM MUST BE CONDUCTED FOR THE EMPLOYER'S CREWMEMBERS AND SUPERVISORY PERSONNEL. SUPERVISORY PERSONNEL MUST RECEIVE AT LEAST 60 MINUTES OF TRAINING. NOTED THAT OPERATOR COULD NOT PROVIDE EVIDENCE OF RECEIVING REQUIRED SUPERVISORY TRAINING. PROVIDE EVIDENCE OF SUPERVISORY TRIANING.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 October 2019
Resolved
THE CERTIFICATE OF INSPECTION MUST BE POSTED UNDER GLASS OR OTHER SUITABLE TRANSPARENT MATERIAL, SUCH THAT ALL PAGES ARE VISIBLE, IN A CONSPICUOUS PLACE ON THE VESSEL WHERE OBSERVATION BY PASSENGERS IS LIKELY. CERTIFICATE OF INSPECTION WAS NOT POSTED. POST CERTIFICATE OF INSPECTION IN A CONSPICUOUS PLACE.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 October 2019
Resolved
VESSEL CONSTRUCTED OF WOOD MUST PROVIDE BILGE LEVEL ALARMS IN ALL WATERTIGHT COMPARTMENTS. BILGE HIGH LEVEL ALARM IN FORWARD COMPARTMENT WAS INOPERABLE. REPAIR OR REPLACE.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 October 2019
Resolved
ABANDON SHIP AND MANOVERBOARD DRILLS AND TRAINING SHALL BE LOGGED OR OTHERWISE DOCUMENTED FOR REVIEW BY THE COAST GUARD UPON REQUEST. NOTED THAT NO ABANDON SHIP DRILLS WERE LOGGED. CONDUCT AND LOG DRILLS IAW WITH 46 CFR 185.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 July 2018
Resolved
Generator would not start.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2018
Resolved 13 May 2020
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 June 2018
Resolved
User Fees in collection. Settle account with treasury.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2018
Resolved 20 July 2018
Resolution: User Fees Paid.
Fire Fighting › Fire Bucket › Quantity
Issued 30 May 2018
Resolved
Missing one fire bucket, only two onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 10 July 2018
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 30 May 2018
Resolved
Needs two types of PFD donning instructions. Needs vest instructions.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 10 July 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 30 May 2018
Resolved
VHF radio needs DSC and GPS along with MMIS number, radio works but needs these items.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 10 July 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 30 May 2018
Resolved
Has two radios that work but after the one radio with GPS is finished with items noted on 03 a new FCC Safety Radio Cert will need to be issued.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2018
Resolved 20 July 2018
Resolution: GPS installed and FCC cert made available.
Navigation › Piloting/Steering › Marine Charts
Issued 30 May 2018
Resolved
All Nav charts, and pubs need updated, charts, coast pilot,light list, rules of the road, tides and currents, and notice to mariners.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2018
Resolved 20 July 2018
Resolution: Provided proper charts.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 30 May 2018
Resolved
Pilot house window, needs appropriate glass, one that does not shatter into fragments and will withstand max load from wave and winds.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 10 July 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 18 July 2017
Resolved
Link GPS to VHF and enter MMSI number IAW 46 CFR 184.502 and 47 CFR 80.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 30 May 2018
Resolution: Re issued during annual exam.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 July 2017
Resolved
Install adel wire clamps every 24 inches throughout all spaces, may be bundled w/ zip ties, IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Proper tie downs and clamps added in spaces.
Construction/Loadline › Penetrations › Valve Flange
Issued 18 July 2017
Resolved
Install handle on fwd compartment bilge valve IAW 46 CFR 182.510.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Handle added and checked.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 July 2017
Resolved
Install adel clamp for light wiring in laz space (on transom) IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Proper tie downs and clamps added in spaces.
Construction/Loadline › Hull › Transverse Frame
Issued 18 July 2017
Resolved
Tighten fasteners and add epoxy to frame around fastners located aft of the port fuel tank inboard of stringer IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Issues done near port fuel tank.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 July 2017
Resolved
Pick up loose debris in bilges throughout vessel IAW 46 CFR 176.804
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Bilge area picked up.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 July 2017
Resolved
Seal wiring going thru deck in fwd engine room located near shore tie, and adel clamps on wire in salon port side IAW 46 CFR 183.340
Due 18 August 2017
Resolved 1 February 2018
Resolution: Wire sealed thru BH. Proper tie downs and clamps added in spaces.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 July 2017
Resolved
Replace wire grommet in water tight junction box located in the engine room along center line near bilge on stringer IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: New box added in E/R.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 July 2017
Resolved
Install rubber wire grommets in all water tight junction boxes in engine room IAW 46 CFR 183.340
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: New box added in E/R
Deck/Cargo › Holds/Tanks › Cargo Tank Drainage
Issued 18 July 2017
Resolved
Secure live well piping w/ clamps/straps along centerline overhead in engine room IAW 46 CFR 182.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Live well piping secured.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 July 2017
Resolved
Replace PVC pipe clamps utilized for wire clamps w adel clamps IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Proper tie downs and clamps added in space.
Communications › Public Address System › Loudspeaker
Issued 18 July 2017
Resolved
Add PA speaker to salon area IAW 46 CFR 184.610.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: PA speaker added to salon area.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 July 2017
Resolved
Safety certificate expired 27JUN17, obtain new safety certificate IAW 46 CFR 184.502 and 47 CFR 80.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 30 May 2018
Resolution: Re issued during annual exam.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 18 July 2017
Resolved
Repair FWD mast light and seal wires where needed for NAV lights IAW NAVRULES 23 and 45 CFR 183.420
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Nav lights working.
Lifesaving › Lifefloat › Paddle
Issued 18 July 2017
Resolved
Lash paddles to life floats w/ 8 feet of black line IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Paddles lashed to life float.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 July 2017
Resolved
Replace STBD engine temp switch wire w/ proper cable IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Proper cable added to temp switch.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 July 2017
Resolved
Fix minor leak on generator exhaust hose IAW 46 CFR 182.610
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 30 May 2018
Resolution: Repaired and tested.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 18 July 2017
Resolved
Attach clamp to toilet OVBD hose in E/R IAW 33 CFR 159.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Clamp added to hose.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 18 July 2017
Resolved
STBD engine shaft packing needs tighten to maintain proper water drip, too much now IAW 46 CFR 186.800
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Shaft leak was repaired.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 July 2017
Resolved
Mount at operating station emergency instructions for foul weather, rough seas, fire in E/R and man overboard IAW 46 CFR 185.512
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Emergency instructions mounted.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 July 2017
Resolved
Label panel box in E/R for shore/gen power and add blank breaker in open slot IAW 46 CFR 183.330
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Panel box was labeled.
Engineering › Freshwater System (air cooling) › Drainage
Issued 18 July 2017
Resolved
Run A/C drain hoses away from generator IAW 46 CFR 176.800
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Drain hoses re routed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 July 2017
Resolved
Repair minor oil leak on port inboard exhaust manifold IAW 46 CFR 182.430
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Oil leak was fixed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 July 2017
Resolved
Run cable chain across top of ladder to top deck and on main deck aft where you board IAW 46 CFR 177.900
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Chain added to top ladder to 2nd deck.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 July 2017
Resolved
FWD of pilot house needs rail attached on top and 12 inches below for proper railing IAW 46 CFR 177.900
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Rail attached to upper deck fwd pilot house.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 18 July 2017
Resolved
Bring recovery ladder back on board for man over board drills IAW 46 CFR 185.520
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 1 February 2018
Resolution: ladder onboard and tested.
Engineering › Generator (propulsion-electric) › Bus
Issued 7 October 2016
Resolved
Generator inoperable due to on going maintenance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Corrected and running.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Blower, Centrifugal
Issued 7 October 2016
Resolved
port engine inoperable due to blower failure on going repair
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Corrected and engine was ran for checks.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 7 October 2016
Resolved
Port and TSBD shaft and rudder post excessive leak repair as needed
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 7 October 2016
Resolved
All exhaust on main ENG hose need to be double clamped and verify remaining clamps are tight on both ends
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Corrected and checked.
Engineering › Diesel Engine (propulsion-electric) › Charge Air Cooling
Issued 7 October 2016
Resolved
Raw water supply line for both main ENG need chaffing gear
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Chaffing gear installed.
Engineering › Fuel Oil Service System › Filter
Issued 7 October 2016
Resolved
Fuel filter needs flame screen and proper drain plug
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Flame bowl added to filter.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2016
Resolved
wiring and alternator on STBD ENG needs to be cleaned and remove all oil
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: All areas cleaned.
Engineering › Bilge Water Management System › Piping
Issued 7 October 2016
Resolved
ENG room bilge pump had improper piping
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Proper hose piping installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2016
Resolved
Bilge pump wiring had improper connectors and need to be sealed or replaced
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 24 July 2017
Resolution: Connectors corrected properly.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 October 2016
Resolved
improper life jacket stowage and labeling. replace refelctive tape and label correctly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Life jacket stowage was labeled.
Engineering › Bilge Water Management System › Manifold
Issued 7 October 2016
Resolved
properly label bilge panel with correct spaces
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Bilge panel labeled.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 7 October 2016
Resolved
STBD ENG mount bolt needs to be tightened
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Engine mount was repaired.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 October 2016
Resolved
Batteries terminal wiring is loose, tighten and replace with permanent type connectors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Battery terminals were tight.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 October 2016
Resolved
Receptacle outlet on port bulkhead needs to be capped
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 October 2016
Resolved
FCC safety radiotelephoney cert has incorrect call sign
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 October 2016
Resolved
Provide EAP supervisory training for master
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Supervisor training conducted.
Navigation › Piloting/Steering › Marine Charts
Issued 7 October 2016
Resolved
Update charts and pubs, coast pilot, light liste, tides and currents, and nav rules
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Updated charts and pubs onboard.
Lifesaving › Lifefloat › Paddle
Issued 7 October 2016
Resolved
Lash paddles to life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2016
Resolved
Remove unused wiring through out vessel.
Engine room and Pilot house had most.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Unused wires were removed.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 October 2016
Resolved
VHF needs to be tied into GPS for DSC to work properly.47 CFR 80.1060
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 7 October 2016
Resolved
Post emergency instructions at pilot house. This is underway drills for your vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Communications › Radio Communications › EPIRB
Issued 7 October 2016
Resolved
Register EPIRB, it has expired.47 CFR 80
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Completed and registered.
Communications › Public Address System › Amplifier
Issued 7 October 2016
Resolved
Install public address system to be heard in accomodation space.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 October 2016
Resolved
Drug consortium for new crew and EPA training.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Consortium letter provided.
Stability › Unintentional Flooding › General
Issued 7 October 2016
Resolved
Openings on deck need covered or sealed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Completed during 2017 drydock.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 October 2016
Resolved
Install anchor light so it can be viewed 360 degrees.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Anchor light installed.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 7 October 2016
Resolved
Waste management plan posted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Waste management plan posted.
Stability › Unintentional Flooding › General
Issued 7 October 2016
Resolved
Forward compartment has a water leak and needs to be addressed. Find leak and provide a repair plan. Vessel may need hauled out.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Leak was repaired during the 2017 drydock.
Construction/Loadline › Structures › Superstructure
Issued 7 October 2016
Resolved
Fwd accomodation space stbd side window needs wood work from rot. Caulk port window
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Window work completed.
Fire Fighting › Fire Bucket › Availability
Issued 7 October 2016
Resolved
Provide 3 fire buckets with fire bucket written on same. 2 gallon metal buckets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Fire buckets on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2016
Resolved
Secure all wire looms in engine room very 24 inches where needed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 October 2016
Resolved
Conduct underway drills when all else is completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Drills conducted.
Electrical › Electric Generation Source (service) › Generator
Issued 29 June 2016
Resolved
Generator inoperable due to on going maintenance.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Diesel Engine (propulsion-reduction gear) › Blower, Centrifugal
Issued 29 June 2016
Resolved
Port engine inoperable due to blower failure. On going repair
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 29 June 2016
Resolved
Port and STBD shaft and rudder post excessive leak repair as needed
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 29 June 2016
Resolved
All exhaust on main ENG hose need to be double clamped and verify remaining clamps are secure.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Sea-water System (primary cooling) › Pump
Issued 29 June 2016
Resolved
Raw water supply line for both main ENG need chaffing gear
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Engineering › Lubricating Oil Service System › Filter
Issued 29 June 2016
Resolved
Fuel filter needs flame screen and proper drain plug
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Diesel Engine (propulsion-reduction gear) › Nozzle, Injection (fuel injection)
Issued 29 June 2016
Resolved
Wiring and alternator on STBD ENG needs to be cleaned and remove all oil
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Bilge Water Management System › Piping
Issued 29 June 2016
Resolved
ENG room bilge pump had improper discharge piping.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Bilge Water Management System › Pump
Issued 29 June 2016
Resolved
Bilge pump wiring had improper connectors and need to be sealed or replaced
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 June 2016
Resolved
Improper life jacket stowage and labeling. Replace reflective tape. Label correctly
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Electrical › Electric Generation Source (service) › Panelboard
Issued 29 June 2016
Resolved
Properly Label bilge panel with correct spaces
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 29 June 2016
Resolved
TBD ENG mount bolt needs to be tightened.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 June 2016
Resolved
Batteries terminal wiring loose tighten and replace with permanent type connectors.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 29 June 2016
Resolved
Receptacle outlet on port bulkhead needs to be capped.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 June 2016
Resolved
FCC safety radiotelephony certificate in correct call sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 June 2016
Resolved
Provide supervisory training for master.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Navigation › Piloting/Steering › Marine Charts
Issued 29 June 2016
Resolved
Update charts and pubs coast pilot light list tides and currents nav rules.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Fire Fighting › Fire Bucket › Quantity
Issued 29 June 2016
Resolved
Provide 3 properly labeled fire buckets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2016
Resolved
Secure wire supports with proper fittings every 24 inches in ENG and under panel at operating station.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 29 June 2016
Resolved
Provide caulking around Windows where leaks were evident.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 29 June 2016
Resolved
Unable to conduct drills underway due to generator and ENG problems.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 April 2014
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 2 April 2014
Resolved 2 April 2014
Resolution: Vessel underwent a satisfactory COI inspection on 31MAR2014. Issued Def for documentation purposes
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 31 March 2014
Resolved
Provide proof of pre-employment drug testing & crew enrollment IAW 46CFR16.230
Action required: 705 - Other - as specified
Due 7 April 2014
Resolved 2 April 2014
Resolution: Proof was provided. Def cleared.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 31 March 2014
Resolved
Emergency instructions not posted IAW 46CFR185.510.
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 2 April 2014
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Hull Plating
Issued 26 March 2014
Resolved
Replace rotten planking around the bilge system through hull fitting on the starboard beam. The planks shall end on butt blocks at least three frame spaces apart IAW NVIC 7-95. 46 CFR 177.10
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 31 March 2014
Resolution: Surveyed repairs to planking in way of bilge overboard discharge thru-hull fitting at stbd beam. Repair was deemed satisfactory.
Construction/Loadline › Hull › Keel
Issued 26 March 2014
Resolved
Replace wasted keel bolt in way of the fourth frame forward of the transom. 46 CFR 177.10
Action required: 705 - Other - as specified
Due 31 March 2014
Resolved 31 March 2014
Resolution: Surveyed repairs to keel bolt in way of fourth frame fwd of transom. Repair was satisfactory.
Lifesaving › Lifefloat › Capacity
Issued 27 February 2012
Resolved
Vessel must provide sufficient capacity of primary lifesaving survival craft or float free EPIRB installation, prior to transiting beyonf 3 nautical miles.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 September 2012
Resolved 11 September 2012
Resolution: EPIRB installation witnessed.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 22 April 2008
Resolved
Provide documentation that Abandon Ship drill was conducted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 22 April 2008
Resolved
Provide a means of effectively securing ventilation to the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 22 April 2008
Resolved
Seal bulkhead between engine room and crew berthing area.
Action required: 705 - Other - as specified
Resolved 29 April 2008
Engineering › Bilge Water Management System › Hose
Issued 22 April 2008
Resolved
Provide a functional portable bilge pump.
Action required: 705 - Other - as specified
Resolved 29 April 2008
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 January 2008
Resolved
Make tail shaft and propellers ready for inspection as per 46 CFR 176.610.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2008
Resolution: Tail shaft and props were made ready and inspected satisfactory.
Construction/Loadline › Structures › Deck Plating
Issued 15 January 2008
Resolved
Make repairs to spongy area on port main deck between gunnel and forward edge of house as per 46 CFR 176.610.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2008
Resolution: Vessel grind and reglassed deck area that was spongy.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 January 2008
Resolved
Secure the ladder going from main deck to 01 deck as per 46 CFR 177.500.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2008
Resolution: Ladder was properly secured.
Lifesaving › Hand Flares › Quantity
Issued 29 March 2007
Resolved
Provide 2 serviceable hand held red flare distress signals approved in accordance with 46 CFR 160.021 as required by 46 CFR 180.68
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2007
Resolved 29 March 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 March 2007
Resolved
Secure deck ice and storage boxes on main deck. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 29 April 2007
Resolved 29 June 2009
Construction/Loadline › Structures › Deck Plating
Issued 29 March 2007
Resolved
Repair deck where separated from bulwarks port side, forward. Repairs to be completed to as built specifications. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 29 April 2007
Resolved 29 June 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 March 2007
Resolved
Terminate conductor butt connectors for electric submersible pump and high bilge level alarms to suitable enclosure in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 29 April 2007
Resolved 29 June 2009
Construction/Loadline › Hull › Hull Plating
Issued 29 March 2007
Resolved
Noted minor leak in way of bilge chine "A" strake seam. Calk seam using acceptable methods and practices. Monitor machinery space bilge while underway and log inspections in deck log. (46 CFR 176.800)
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 April 2007
Resolved 29 June 2009
Lifesaving › Lifebuoys › Stowage
Issued 29 March 2007
Resolved
Provide 3 foot lanyard and corrosion resistant clip for life ring buoy as required by 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 29 April 2007
Resolved 29 June 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 15 March 2006
Resolved
Provide proper "Emergency Broadcast" placard as per 46 CFR 184.506.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Lifesaving › Lifefloat › Markings
Issued 15 March 2006
Resolved
Re-stencil vessel name on life float. 46CFR185.604
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 March 2006
Resolved
Replace starboard navigation light lens in accordance with COLREGS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 March 2006
Resolved
Conduct and log drills prior to carrying passengers as required by 46CFR185
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 15 March 2006
Resolved
Obtain current copy of Inland Navigation Rules as per 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 15 March 2006
Resolved
Properly mount access ladder to upper deck in accordance with NVIC 7-95.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Stability › Unintentional Flooding › General
Issued 15 March 2006
Resolved
Properly label high level bilge alarms as required by 46CFR182.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Engineering › Steering Gear System › Rudder Stock
Issued 15 March 2006
Resolved
Properly adjust and/or replace if necessary, rudder packing to stop ingress of water as per 46 CFR 176.802.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Electrical › Electrical Distribution System (emergency) › Grounding Conductor
Issued 15 March 2006
Resolved
Properly secure fasteners on hull bonding wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 March 2006
Resolved
Install eye bolts or other means for cable to actuate shutdown handles on emergency fuel shut-offs as per 46 CFR 182.455.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 15 March 2006
Resolved
Provide means to secure gravity fed MSD tank as required by 33CFR159.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 March 2006
Resolved
Provide evidence of the annually required servicing of the Fixed Fire Fighting System as per 46 CFR 181.400.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 29 March 2006
Construction/Loadline › Structures › Deck Plating
Issued 14 September 2005
Resolved
Renew deck in cabin area as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 29 March 2006
Resolved 29 March 2006
Construction/Loadline › Structures › Deck Plating
Issued 14 September 2005
Resolved
Renew two deck support beams in engine room deckhead located above main engine transmission as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Replaced all deck supports from forward bulkhead in the engine room to the stern
Engineering › Fuel Oil Service System › Valve, Control
Issued 14 September 2005
Resolved
Renew/Repair and prove operation of emergency fuel shut off valve as per 46 CFR 182.20-40.
Action required: 705 - Other - as specified
Due 29 March 2006
Resolved 29 March 2006
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 14 September 2005
Resolved
Renew brackets supporting fuel tank.
Action required: 705 - Other - as specified
Due 29 March 2006
Resolved 29 March 2006
Construction/Loadline › Structures › Deck Plating
Issued 14 September 2005
Resolved
Remove plywood sheathing covering deck planking in bow area and repair deteriorated deck planking as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Removed the plywood and made repairs to the bow
Construction/Loadline › Structures › Deck Plating
Issued 14 September 2005
Resolved
Renew damaged deck rail as original as per 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 29 March 2006
Resolved 29 March 2006
Construction/Loadline › Hull › Hull Plating
Issued 14 September 2005
Resolved
Renew all damaged strip planking on starboard side Iof vessel as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Renewed all damaged strip planks on starboard side
Construction/Loadline › Structures › Trunk
Issued 14 September 2005
Resolved
Renew damaged transom planking and associated support structure as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Renewed damaged area of transom
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 September 2005
Resolved
Renew all damaged or broken frames throughout vessel as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Repaired all damaged frames
Construction/Loadline › Hull › Side Shell
Issued 14 September 2005
Resolved
Renew damaged starboard chine as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Renewed damaged area of chine.
Construction/Loadline › Hull › Hull Plating
Issued 14 September 2005
Resolved
Renew holed planking located on transom as original and in accordance with IAW NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Replaced the holed planks at transom
Construction/Loadline › Hull › Side Shell
Issued 14 September 2005
Resolved
Renew damaged port side shell planking where marked by the attending marine inspector as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Renewed marked areas on the port side
Construction/Loadline › Hull › Side Shell
Issued 14 September 2005
Resolved
Renew damaged hull planking on starboard side marked by the attending marine inspector as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Renewed marked areas on the starboard side
Construction/Loadline › Hull › Side Shell
Issued 14 September 2005
Resolved
Renewdamaged hull planking on starboard side above waterline as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Renewed damaged plank on starboard side above the water line
Construction/Loadline › Hull › Keel
Issued 14 September 2005
Resolved
Renew damaged hull planking on starboard side forward from keel to stem as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Replaced damaged planks on starboard side
Construction/Loadline › Hull › Side Shell
Issued 14 September 2005
Resolved
Renew deteriorated port and starboard rubrail as original and in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 28 December 2005
Resolved 28 December 2005
Resolution: Renewed rub rail
Electrical › Electric Generation Source (service)
Issued 18 May 2004
Resolved
Repair SSDG shutdown and provide service report prior top carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2004
Resolved 20 May 2004
Resolution: SSDG repaired report faxed to MSD.
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 May 2004
Resolved
Renew retro tape on 11 identified life jackets prior to carrying passengers for hire. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2004
Resolved 18 May 2004
Resolution: Retro tape renewed.
Construction/Loadline › Hull
Issued 1 March 2004
Resolved
Renew three bottom planks starboard side in way of stem. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2004
Resolved 15 March 2004
Resolution: Owner rplaced planks in kind.
Documentation › Certificates/Documents
Issued 17 April 2003
Resolved
Provide FCC Safety Certificate with updated information per 47 CFR 80.13
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided FCC Safety Certificate.
Communications › Visual Communication
Issued 17 April 2003
Resolved
Provide emergency instruction list posted at the operating station. 46CFR185.510
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided emergency instruction list.
Navigation › Piloting/Steering
Issued 17 April 2003
Resolved
Provide up to date navigational publications & charts per 46 CFR 184.420 LEGACY COMPONENT DESC: Marine Charts
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided up to date navigational pubs and charts.
Construction/Loadline › Hull
Issued 17 April 2003
Resolved
Remove and treat angel hair problem in engine room.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner removed and treated angel hair in E/R.
Stability › Watertight Integrity
Issued 17 April 2003
Resolved
Provide necessary repairs/equipment to make forward bulkhead watertight per 46CFR179.320.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 21 April 2003
Resolution: Examined, found sat.
Lifesaving › Buoyant Apparatus
Issued 17 April 2003
Resolved
Provide mount for waterlight attached to lifefloat per 46CFR180.175
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided mount for waterlight attached to life float.
Lifesaving › Buoyant Apparatus
Issued 17 April 2003
Resolved
Ensure paddles for lifefloat are attached to lifeboat per 46CFR180.175
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner attached paddles to lifefloat.
Lifesaving › Lifebuoys
Issued 17 April 2003
Resolved
Replace ring bouy prior to carrying passengers per 46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 21 April 2003
Resolution: Examined, found sat.
Lifesaving › Lifejacket/PFD (General)
Issued 17 April 2003
Resolved
Replace retroreflective tape of 16 adult lifejackets per 46 CFR 180.71. LEGACY COMPONENT DESC: Retroreflective Material
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner replaced retro tape on 16 identified adult lifejackets.
Documentation › Markings/Placards
Issued 17 April 2003
Resolved
Provide markings for emergency fuel shut off per 46 CFR 185.30-15 (1995)
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided markings for emergency fuel shut offs.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 April 2003
Resolved
Replace wasted clamps on port & starboard transom flange connection for the main engine exhaust per 46 CFR 179.350
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner replaced wasted clamps on P & S transom flange connections.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 April 2003
Resolved
Replace the salt water supply line hose for the starboard main engine per 46 CFR 182.710.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 21 April 2003
Resolution: Examined, found sat.
Engineering › Diesel Engine (auxiliary)
Issued 17 April 2003
Resolved
Replace the salt waters supply flexible hose on the generator per 46 CFR 182.720.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner replaced supply flex hose on generator.
Electrical › Electrical Distribution System (service)
Issued 17 April 2003
Resolved
Provide acceptable enclosure for the generator switch for the shore tie per 46 CFR 183.390
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided acceptable enclosure for generator switch.
Electrical › Electrical Distribution System (service)
Issued 17 April 2003
Resolved
Provide UL approved wiring for 110V cables per 46 CFR 183.340
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided UL approved wiring for 110v cables.
Electrical › Electrical Distribution System (service)
Issued 17 April 2003
Resolved
Provide acceptable enclosure for switchboard per 46 CFR 183.340.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided acceptable enclosure for switchboard.
Communications › Internal Communications System
Issued 17 April 2003
Resolved
Install and demonstrate proper operation of public adderss system per 46 CFR 184.610.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner installed and demonstrated proper operation of public address system.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 April 2003
Resolved
Permanently mount freezer.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner permanently mounted freezer.
Construction/Loadline › Hull
Issued 17 April 2003
Resolved
Replace inboard rudder block.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 21 April 2003
Resolution: Examined, found sat.
Construction/Loadline › Hull
Issued 17 April 2003
Resolved
Provide backer block reinforcement for strut connectoin per 46 CFR 177.315.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 21 April 2003
Resolution: Examined, found sat.
Navigation
Issued 6 March 1997
Resolved
REPLACE STEERING RAM PEDESTAL BEARING BOLTS (4) AND TIGHTEN BASE SO AS NOT TO ROCK ON FOUNDATION
Condition: Unknown
Due 30 March 1997
Resolved 4 August 1997
Electrical
Issued 6 March 1997
Resolved
PROPERLY MOUNT NEW GENERATOR OPERATING GAGE PANEL SO AS NOT TO HANG BY WIRING.
Condition: Unknown
Due 30 March 1997
Resolved 4 August 1997
Engineering
Issued 11 April 1996
Resolved
REPAIR PORT INBOARD EXHAUST LEAK WHERE MARKED ON EXHAUST PIPING.
Condition: Unknown
Due 11 April 1996
Resolved 8 May 1996
Construction/Loadline
Issued 11 April 1996
Resolved
CONDUCT U/W SEA TRIAL IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR. _x001C_VSL RESTRICTED FROM CARRYING MORE THAN SIX PASSENGERS UNTIL THIS REQUIREMENT IS CORRECTED.
Condition: Unknown
Due 11 May 1996
Resolved 8 May 1996
Construction/Loadline
Issued 11 April 1996
Resolved
REPAIR HULL WATER LEAKS ON STRIP PLANKING 12" ABOVE KEEL BETWEEN STBD SIDE FRAMES 1,2, AND 3 IN FOREPEAK. VSL RESTRCITED FROM CARRYING MORE THAN SIX PASSENGERS UNTIL REPAIRS COMPLETED TO THE SATISFACTION OF THE ATENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 May 1996
Resolved 8 May 1996
Construction/Loadline
Issued 11 April 1996
Resolved
REPAIR/RECAULK HULL WATER LEAKS BETWEEN STRIP PLANKS AS MARKED 30 INCHES ABOVE KEEL BETWEEN PORT SIDE FRAMES 3 AND 4 IN FOREPEAK. VSL RESTRICTED FROM CARRYING MORE THAN SIX PASSENGERS UNTIL CORRECTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 May 1996
Resolved 8 May 1996
Construction/Loadline
Issued 11 April 1996
Resolved
REAPIR/RECAULK STRIP PLANK HULL WATER LEAKS LOCATED 38" ABOVE KEEL, PORT SIDE, BETWEEN FRAMES 4 AND 5 IN FOREPEAK. REPAIRS TO BE CORRECTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, VSL RESTRICTED FROM CARRYING MORE THAN SIX PASSENGERS UNTIL CORRECTED.
Condition: Unknown
Due 11 May 1996
Resolved 8 May 1996
Construction/Loadline
Issued 11 April 1996
Resolved
RENEW WASTED STRUT BLOCKS ON BOTH THE PORT AND STBD STRUTS. REMOVE DISSIMILIAR METALS AND RENEW AS ORIGINAL.
Condition: Unknown
Due 11 May 1996
Resolved 8 May 1996
Fire Fighting
Issued 16 March 1995
Resolved
PROVIDE 1 B-II FIRE EXTINGUISHER FOR FORWARD CABIN.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Accommodation/Occupational Safety
Issued 16 March 1995
Resolved
REFASTEN BOTH LADDERS TO PILOT HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Navigation
Issued 16 March 1995
Resolved
INSTALL THIMBLE ON ANCHOR LINE AND MOUSE SHACKLE
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Electrical
Issued 16 March 1995
Resolved
PROVIDE COVERS FOR 100V SWITCH AND METERS (BACK COVERS)
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Lifesaving
Issued 16 March 1995
Resolved
MAKE REPAIRS TO LIFEFLOAT LIFELINE AND RESENCILE.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Electrical
Issued 16 March 1995
Resolved
PROVIDE ANTI-CHAFFING DEVICE ON 110 VOLT ELECTRICAL PANEL IN FORWARD CABIN.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Construction/Loadline
Issued 16 March 1995
Resolved
INSTALL BONDING STRAPS/ON ALL HULL THRU VALVES AND MACHINERY.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Engineering
Issued 16 March 1995
Resolved
INSTALL MACHINERY GUARDS ON STBD MAIN ENGINE WASHDOWN PUMP AND ALTERNATOR
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Lifesaving
Issued 14 March 1994
Resolved
REPAIR OR RENEW LIFE FLOAT GRAB LINES AND NETTING TO MEET REQUIREMENTS SETFORTH IN 46 CFR 160.027.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Documentation
Issued 14 March 1994
Resolved
PROVIDE EVIDENCE OF CHEMICAL TESTING OF ALL MARINE EMPLOYEES IAW 46CFR16.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Engineering
Issued 14 March 1994
Resolved
PROVE OPERATION OF PILOTHOUSE CONTROL,THE ABILITY TO START AND STOP PROPULSION ENGINES FROM THE MAIN STEERING STATION.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Construction/Loadline
Issued 14 March 1994
Resolved
REPAIR HOLES IN COLLISION BULKHEAD AND PROVE WATERTIGHTNESS OF BULKHEAD AFTER REPAIRS ARE COMPLETED.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Accommodation/Occupational Safety
Issued 14 March 1994
Resolved
REPAIR LOOSE AND DAMAGED UPPER DECK RAILS
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Navigation
Issued 14 March 1994
Resolved
RELOCATE FWD MAST HEAD LIGHT TO ENSURE IS NOT OBSTRUCTED
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Navigation
Issued 14 March 1994
Resolved
PROVE OPERATION OF STERN LIGHT_x001C_
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Electrical
Issued 14 March 1994
Resolved
SERVICE, CLEAN AND TIGHTEN ALL BATTERY TERMINALS AND CONNECTIONS.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Engineering
Issued 14 March 1994
Resolved
REPAIR/RENEW RAW WATER PUMP TO STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Engineering
Issued 10 March 1993
Resolved
INSTALL REACHRODS TO EMERGENCY FUEL OIL SHUTOFF VALVES.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Engineering
Issued 10 March 1993
Resolved
PROPERLY LABEL PORT EMERGENCY FUEL OIL SHUTOFF VALVE.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Engineering
Issued 10 March 1993
Resolved
RENEW FLAME SCREEN OF 30X30 WIRE MESH TO FUEL OIL TANK VENT.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Construction/Loadline
Issued 10 March 1993
Resolved
REPAIR LEAK ON THROUGH HULL FITTING THAT SUPPLIES WATER TO STBD MAIN DIESELENGINE DRIVEN BILGE PUMP.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Electrical
Issued 10 March 1993
Resolved
SUPPORT AND REATTACH BATTERY BOXES TO VESSEL TO PREVENT SHIFTING.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Fire Fighting
Issued 10 March 1993
Resolved
SEVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Lifesaving
Issued 10 March 1993
Resolved
RENEW WORN RETRO REFLECTIVE MATERIAL TO LIFE FLOAT.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Engineering
Issued 10 March 1993
Resolved
PROPERLY SUPPORT PORT/STBD MAIN DIESEL ENGINE RAW WATER SUCTION PIPING.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Electrical
Issued 10 March 1993
Resolved
PROVE OPERATION OF AMMETER TO S/S GENERATOR.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Accommodation/Occupational Safety
Issued 10 March 1993
Resolved
RENEW DETERIORATED FLEXIBLE NON-METALLIC HOES TO OVBD DRAIN LOCATED OUTBOARD OF STBD MAIN DIESEL ENGINE.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Electrical
Issued 10 March 1993
Resolved
REMOVE OR RENEW ENGINE ROOM LIGHTING TO MEET THE STANDARDS SETFORTH IN 46CFR183.10.20.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Accommodation/Occupational Safety
Issued 10 March 1993
Resolved
RENEW WORN NON-METALLIC FLEXIBLE HOSE FROM MSD TANK TO OVBD DISCHARGE.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Electrical
Issued 10 March 1993
Resolved
SUPPORT ENGINE NOISE SUPPESSOR SO ITS NOT INSTALLED IN THE VESSELS BILGES
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Accommodation/Occupational Safety
Issued 10 March 1993
Resolved
RENEW DAMAGED ENGINE ROOM VENTILATION DUCT ON STBD SIDE OF ENGINE ROOM.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Electrical
Issued 10 March 1993
Resolved
IDENTIFY AND LABEL ALL ELECTRICAL DISTRIBUTION PANELS WITH PURPOSE OF CIRCUITS. INSTALL BLANKS WHERE CIRCUIT BREAKERS ARE MISSING IN DISTRIBUTIONPANELS.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Construction/Loadline
Issued 18 March 1992
Resolved
INSTALL (1) HOSE CLAMP FOR W/D PUMP THRU-HULL FITTING.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Navigation
Issued 18 March 1992
Resolved
RELOCATE MAST HEAD LIGHT TO PROVIDE 1 METER SEPARATION FROM SIDE LIGHTS ANDPROVIDE PROPER RANGE LIGHT.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Engineering
Issued 18 March 1992
Resolved
INSTALL FIBERGLASS OR LEAD LINED BATTERY BOX FOR GENERATOR BATTERY.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Engineering
Issued 18 March 1992
Resolved
PROVIDE AND INSTALL (2) FLAME SCREENS FOR FUEL TANK VENTS.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Accommodation/Occupational Safety
Issued 18 March 1992
Resolved
PROVIDE AND INSTALL PVC PIPE ELBOW PORT SIDE MSD LINE.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Construction/Loadline
Issued 18 March 1992
Resolved
REMOVE OIL FROM BILGES AND FORWARD COMPARTMENT.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Lifesaving
Issued 18 March 1992
Resolved
PROVIDE (2) ADDITIONAL ADULT LIFE PRESERVERS. UNTIL PROVIDED, TOTAL PERSONS ALLOWED IS REDUCED TO (49).
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Electrical
Issued 8 November 1991
Resolved
REPAIR/REPLACE BATTERY BOXES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 November 1991
Resolved 8 November 1991
Electrical
Issued 8 November 1991
Resolved
PROVIDE DRAWINGS, SKETCHES, AND WRITTEN SPECIFICATIONS DEPICTING THE INSTALLATION OF SHIP SERVICE GENERATOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 November 1991
Resolved 8 November 1991
Engineering
Issued 8 November 1991
Resolved
PROVIDE A SUITABLE WARNING DEVICE TO INDICATE ANY FAILURE OF WATER FLOW IN THE EXHAUST COOLING SYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 November 1991
Resolved 8 November 1991