Records from 2005 to 2021. Most recent: inspection, 15 January 2021.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2020
No resolution recorded
no repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. The procedures to be followed in notifying the Coast Guard about vessel repairs vary according to the type of vessel and service in which engaged. Vessel owner/operator notified CG that the vessel suffered damage due to Hurricane Sally in accordance with applicable regulatory cite. Vessel must make permanent repair/alteration to the satisfaction of the OCMI in accordance with 46 CFR 176.700(a).
Action required: 705 - Other - as specified
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2020
Resolved
Vessel day time running light was inoperable. All vessels must have nav lights in compliance with inland nav rules.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Provided pictures of operable nav light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 May 2020
Resolved
Generator fuel lines must be complete with factory-assembled end fittings required. Fuel lines were not properly secured per regulations to gen-set.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Provided pictures of approved factory assembled hose fittings.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2020
Resolved
Electrical panel had exposed coverings. Electrical equipment must be installed to protect crew from electrical hazards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Covered exposed wires in electrical panel, provided pictures showing proof.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2020
Resolved
Bond wire for fuel tank was not properly grounded to vessel. All fuel tanks must be electrically bonded to a common ground.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 14 May 2020
Resolution: Bonded loose fuel tank wires to grounding point. Provided satisfactory pictures to MI.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 8 October 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire. Noted that the main engines, generator was due for maintanence. Maintenance machinery and clean bilges to prevent fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal, vessel rectified all prior deficiencies to the satisfaction of the attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 October 2019
Resolved
Repairs or alternative to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Noted that there was a hole in a plank below the waterline in the forward compartment allowing water to actively ingress into the space. Provide repair plan for approval by Sector Mobile OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel O/O and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
Electrical equipment must be installed and maintained to protect passengers and crew from hazards, fire, and shock. Multiple deadend wires found throughout the vessel. Remove all deadend wires or place in appropriate junction box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE OFFICER IN CHARGE, MARINE INSPECTION. NOTED NO COVER FOR THE FORWARD OUTLET IN THE ENGINE ROOM OR TWO OVERHEAD OUTLETS IN THE GALLEY. INSTALL AND PROPERLY SECURE COVERS FOR ELECTRICAL OUTLETS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
ELECTRICAL EQUIPMENT MUST BE INSTALLED AND MAINTAINED TO PROTECT PASSENGERS AND CREW FROM HAZARDS, FIRE, AND SHOCK. NOTED OPEN GROUND IN ENGINE ROOM OUTLET AND IN THE WHEELHOUSE. REWIRE IAW WITH 46 CFR 183.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 October 2019
Resolved
VESSEL MUST CARRY ADEQUATE AND UP TO DATE CHARTS FOR INTENDED VOYAGE. VESSEL DOES NOT HAVE CURRENT NAV CHARTS FOR ROUTE AND AREA. UPDATE NAV CHARTS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 October 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 October 2019
Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE OFFICER IN CHARGE, MARINE INSPECTION. CIRCUIT BREAKER NOT LABELED. PROPERLY LABEL CIRCUIT BREAKER.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 October 2019
Resolved
EACH ITEM OF SURVIVAL CRAFT EQUIPMENT MUST BE OF GOOD QUALITY, AND EFFICIENT FOR THE PURPOSE IS IS INTENDED TO SERVE. NOTED LIFE FLOAT WAS IN DETERIORATED CONDITION.
REPAIR OR REPLACE IAW 46 CFR 160.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 October 2019
Resolved
THE NAME OF A VESSEL MUST BE MARKED OR PAINTED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH RING LIFE BUOY. NOTED THAT NAME WAS NOT LEGIBLE ON RING LIFE BUOY.RELABEL RING LIFE BUOY.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 8 October 2019
Resolved
AN EAP TRAINING PROGRAM MUST BE CONDUCTED FOR THE EMPLOYER'S CREWMEMBERS AND SUPERVISORY PERSONNEL. SUPERVISORY PERSONNEL MUST RECEIVE AT LEAST 60 MINUTES OF TRAINING. NOTED THAT OPERATOR COULD NOT PROVIDE EVIDENCE OF RECEIVING REQUIRED SUPERVISORY TRAINING. PROVIDE EVIDENCE OF SUPERVISORY TRIANING.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 October 2019
Resolved
THE CERTIFICATE OF INSPECTION MUST BE POSTED UNDER GLASS OR OTHER SUITABLE TRANSPARENT MATERIAL, SUCH THAT ALL PAGES ARE VISIBLE, IN A CONSPICUOUS PLACE ON THE VESSEL WHERE OBSERVATION BY PASSENGERS IS LIKELY. CERTIFICATE OF INSPECTION WAS NOT POSTED. POST CERTIFICATE OF INSPECTION IN A CONSPICUOUS PLACE.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 October 2019
Resolved
VESSEL CONSTRUCTED OF WOOD MUST PROVIDE BILGE LEVEL ALARMS IN ALL WATERTIGHT COMPARTMENTS. BILGE HIGH LEVEL ALARM IN FORWARD COMPARTMENT WAS INOPERABLE. REPAIR OR REPLACE.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 October 2019
Resolved
ABANDON SHIP AND MANOVERBOARD DRILLS AND TRAINING SHALL BE LOGGED OR OTHERWISE DOCUMENTED FOR REVIEW BY THE COAST GUARD UPON REQUEST. NOTED THAT NO ABANDON SHIP DRILLS WERE LOGGED. CONDUCT AND LOG DRILLS IAW WITH 46 CFR 185.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2020
Resolution: Conducted inspection for COI renewal on 13 May 2020 at Zeke's Landing Marina. Vessel o/o and crew were able to successfully rectify all prior issued deficiencies to the satisfaction of the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 July 2018
Resolved
Generator would not start.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2018
Resolved 13 May 2020
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 June 2018
Resolved
User Fees in collection. Settle account with treasury.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2018
Resolved 20 July 2018
Resolution: User Fees Paid.
Fire Fighting › Fire Bucket › Quantity
Issued 30 May 2018
Resolved
Missing one fire bucket, only two onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 10 July 2018
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 30 May 2018
Resolved
Needs two types of PFD donning instructions. Needs vest instructions.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 10 July 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 30 May 2018
Resolved
VHF radio needs DSC and GPS along with MMIS number, radio works but needs these items.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 10 July 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 30 May 2018
Resolved
Has two radios that work but after the one radio with GPS is finished with items noted on 03 a new FCC Safety Radio Cert will need to be issued.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2018
Resolved 20 July 2018
Resolution: GPS installed and FCC cert made available.
Navigation › Piloting/Steering › Marine Charts
Issued 30 May 2018
Resolved
All Nav charts, and pubs need updated, charts, coast pilot,light list, rules of the road, tides and currents, and notice to mariners.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2018
Resolved 20 July 2018
Resolution: Provided proper charts.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 30 May 2018
Resolved
Pilot house window, needs appropriate glass, one that does not shatter into fragments and will withstand max load from wave and winds.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 10 July 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 18 July 2017
Resolved
Link GPS to VHF and enter MMSI number IAW 46 CFR 184.502 and 47 CFR 80.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 30 May 2018
Resolution: Re issued during annual exam.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 July 2017
Resolved
Install adel wire clamps every 24 inches throughout all spaces, may be bundled w/ zip ties, IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Proper tie downs and clamps added in spaces.
Construction/Loadline › Penetrations › Valve Flange
Issued 18 July 2017
Resolved
Install handle on fwd compartment bilge valve IAW 46 CFR 182.510.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Handle added and checked.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 July 2017
Resolved
Install adel clamp for light wiring in laz space (on transom) IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Proper tie downs and clamps added in spaces.
Construction/Loadline › Hull › Transverse Frame
Issued 18 July 2017
Resolved
Tighten fasteners and add epoxy to frame around fastners located aft of the port fuel tank inboard of stringer IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Issues done near port fuel tank.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 July 2017
Resolved
Pick up loose debris in bilges throughout vessel IAW 46 CFR 176.804
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Bilge area picked up.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 July 2017
Resolved
Seal wiring going thru deck in fwd engine room located near shore tie, and adel clamps on wire in salon port side IAW 46 CFR 183.340
Due 18 August 2017
Resolved 1 February 2018
Resolution: Wire sealed thru BH. Proper tie downs and clamps added in spaces.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 July 2017
Resolved
Replace wire grommet in water tight junction box located in the engine room along center line near bilge on stringer IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: New box added in E/R.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 July 2017
Resolved
Install rubber wire grommets in all water tight junction boxes in engine room IAW 46 CFR 183.340
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: New box added in E/R
Deck/Cargo › Holds/Tanks › Cargo Tank Drainage
Issued 18 July 2017
Resolved
Secure live well piping w/ clamps/straps along centerline overhead in engine room IAW 46 CFR 182.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Live well piping secured.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 July 2017
Resolved
Replace PVC pipe clamps utilized for wire clamps w adel clamps IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Proper tie downs and clamps added in space.
Communications › Public Address System › Loudspeaker
Issued 18 July 2017
Resolved
Add PA speaker to salon area IAW 46 CFR 184.610.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: PA speaker added to salon area.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 July 2017
Resolved
Safety certificate expired 27JUN17, obtain new safety certificate IAW 46 CFR 184.502 and 47 CFR 80.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 30 May 2018
Resolution: Re issued during annual exam.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 18 July 2017
Resolved
Repair FWD mast light and seal wires where needed for NAV lights IAW NAVRULES 23 and 45 CFR 183.420
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Nav lights working.
Lifesaving › Lifefloat › Paddle
Issued 18 July 2017
Resolved
Lash paddles to life floats w/ 8 feet of black line IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Paddles lashed to life float.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 July 2017
Resolved
Replace STBD engine temp switch wire w/ proper cable IAW 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Proper cable added to temp switch.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 July 2017
Resolved
Fix minor leak on generator exhaust hose IAW 46 CFR 182.610
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 30 May 2018
Resolution: Repaired and tested.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 18 July 2017
Resolved
Attach clamp to toilet OVBD hose in E/R IAW 33 CFR 159.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Clamp added to hose.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 18 July 2017
Resolved
STBD engine shaft packing needs tighten to maintain proper water drip, too much now IAW 46 CFR 186.800
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Shaft leak was repaired.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 July 2017
Resolved
Mount at operating station emergency instructions for foul weather, rough seas, fire in E/R and man overboard IAW 46 CFR 185.512
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Emergency instructions mounted.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 July 2017
Resolved
Label panel box in E/R for shore/gen power and add blank breaker in open slot IAW 46 CFR 183.330
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Panel box was labeled.
Engineering › Freshwater System (air cooling) › Drainage
Issued 18 July 2017
Resolved
Run A/C drain hoses away from generator IAW 46 CFR 176.800
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Drain hoses re routed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 July 2017
Resolved
Repair minor oil leak on port inboard exhaust manifold IAW 46 CFR 182.430
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Oil leak was fixed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 July 2017
Resolved
Run cable chain across top of ladder to top deck and on main deck aft where you board IAW 46 CFR 177.900
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Chain added to top ladder to 2nd deck.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 July 2017
Resolved
FWD of pilot house needs rail attached on top and 12 inches below for proper railing IAW 46 CFR 177.900
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 1 February 2018
Resolution: Rail attached to upper deck fwd pilot house.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 18 July 2017
Resolved
Bring recovery ladder back on board for man over board drills IAW 46 CFR 185.520
Action required: 705 - Other - as specified
Due 19 August 2017
Resolved 1 February 2018
Resolution: ladder onboard and tested.
Engineering › Generator (propulsion-electric) › Bus
Issued 7 October 2016
Resolved
Generator inoperable due to on going maintenance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Corrected and running.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Blower, Centrifugal
Issued 7 October 2016
Resolved
port engine inoperable due to blower failure on going repair
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Corrected and engine was ran for checks.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 7 October 2016
Resolved
Port and TSBD shaft and rudder post excessive leak repair as needed
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 7 October 2016
Resolved
All exhaust on main ENG hose need to be double clamped and verify remaining clamps are tight on both ends
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Corrected and checked.
Engineering › Diesel Engine (propulsion-electric) › Charge Air Cooling
Issued 7 October 2016
Resolved
Raw water supply line for both main ENG need chaffing gear
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Chaffing gear installed.
Engineering › Fuel Oil Service System › Filter
Issued 7 October 2016
Resolved
Fuel filter needs flame screen and proper drain plug
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Flame bowl added to filter.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2016
Resolved
wiring and alternator on STBD ENG needs to be cleaned and remove all oil
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: All areas cleaned.
Engineering › Bilge Water Management System › Piping
Issued 7 October 2016
Resolved
ENG room bilge pump had improper piping
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Proper hose piping installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2016
Resolved
Bilge pump wiring had improper connectors and need to be sealed or replaced
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 24 July 2017
Resolution: Connectors corrected properly.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 October 2016
Resolved
improper life jacket stowage and labeling. replace refelctive tape and label correctly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Life jacket stowage was labeled.
Engineering › Bilge Water Management System › Manifold
Issued 7 October 2016
Resolved
properly label bilge panel with correct spaces
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Bilge panel labeled.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 7 October 2016
Resolved
STBD ENG mount bolt needs to be tightened
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Engine mount was repaired.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 October 2016
Resolved
Batteries terminal wiring is loose, tighten and replace with permanent type connectors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Battery terminals were tight.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 October 2016
Resolved
Receptacle outlet on port bulkhead needs to be capped
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 October 2016
Resolved
FCC safety radiotelephoney cert has incorrect call sign
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 October 2016
Resolved
Provide EAP supervisory training for master
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Supervisor training conducted.
Navigation › Piloting/Steering › Marine Charts
Issued 7 October 2016
Resolved
Update charts and pubs, coast pilot, light liste, tides and currents, and nav rules
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Updated charts and pubs onboard.
Lifesaving › Lifefloat › Paddle
Issued 7 October 2016
Resolved
Lash paddles to life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2016
Resolved
Remove unused wiring through out vessel.
Engine room and Pilot house had most.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Unused wires were removed.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 October 2016
Resolved
VHF needs to be tied into GPS for DSC to work properly.47 CFR 80.1060
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 7 October 2016
Resolved
Post emergency instructions at pilot house. This is underway drills for your vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Communications › Radio Communications › EPIRB
Issued 7 October 2016
Resolved
Register EPIRB, it has expired.47 CFR 80
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Completed and registered.
Communications › Public Address System › Amplifier
Issued 7 October 2016
Resolved
Install public address system to be heard in accomodation space.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 October 2016
Resolved
Drug consortium for new crew and EPA training.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Consortium letter provided.
Stability › Unintentional Flooding › General
Issued 7 October 2016
Resolved
Openings on deck need covered or sealed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Completed during 2017 drydock.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 October 2016
Resolved
Install anchor light so it can be viewed 360 degrees.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Anchor light installed.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 7 October 2016
Resolved
Waste management plan posted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Waste management plan posted.
Stability › Unintentional Flooding › General
Issued 7 October 2016
Resolved
Forward compartment has a water leak and needs to be addressed. Find leak and provide a repair plan. Vessel may need hauled out.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Leak was repaired during the 2017 drydock.
Construction/Loadline › Structures › Superstructure
Issued 7 October 2016
Resolved
Fwd accomodation space stbd side window needs wood work from rot. Caulk port window
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Window work completed.
Fire Fighting › Fire Bucket › Availability
Issued 7 October 2016
Resolved
Provide 3 fire buckets with fire bucket written on same. 2 gallon metal buckets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Fire buckets on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2016
Resolved
Secure all wire looms in engine room very 24 inches where needed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: This deficiency is a duplicate and will be done via activity 6107940.
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 October 2016
Resolved
Conduct underway drills when all else is completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 18 July 2017
Resolution: Drills conducted.
Electrical › Electric Generation Source (service) › Generator
Issued 29 June 2016
Resolved
Generator inoperable due to on going maintenance.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Diesel Engine (propulsion-reduction gear) › Blower, Centrifugal
Issued 29 June 2016
Resolved
Port engine inoperable due to blower failure. On going repair
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 29 June 2016
Resolved
Port and STBD shaft and rudder post excessive leak repair as needed
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 29 June 2016
Resolved
All exhaust on main ENG hose need to be double clamped and verify remaining clamps are secure.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Sea-water System (primary cooling) › Pump
Issued 29 June 2016
Resolved
Raw water supply line for both main ENG need chaffing gear
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Engineering › Lubricating Oil Service System › Filter
Issued 29 June 2016
Resolved
Fuel filter needs flame screen and proper drain plug
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Diesel Engine (propulsion-reduction gear) › Nozzle, Injection (fuel injection)
Issued 29 June 2016
Resolved
Wiring and alternator on STBD ENG needs to be cleaned and remove all oil
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Bilge Water Management System › Piping
Issued 29 June 2016
Resolved
ENG room bilge pump had improper discharge piping.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Bilge Water Management System › Pump
Issued 29 June 2016
Resolved
Bilge pump wiring had improper connectors and need to be sealed or replaced
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 June 2016
Resolved
Improper life jacket stowage and labeling. Replace reflective tape. Label correctly
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Electrical › Electric Generation Source (service) › Panelboard
Issued 29 June 2016
Resolved
Properly Label bilge panel with correct spaces
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 29 June 2016
Resolved
TBD ENG mount bolt needs to be tightened.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 June 2016
Resolved
Batteries terminal wiring loose tighten and replace with permanent type connectors.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 29 June 2016
Resolved
Receptacle outlet on port bulkhead needs to be capped.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 June 2016
Resolved
FCC safety radiotelephony certificate in correct call sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 June 2016
Resolved
Provide supervisory training for master.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Navigation › Piloting/Steering › Marine Charts
Issued 29 June 2016
Resolved
Update charts and pubs coast pilot light list tides and currents nav rules.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Fire Fighting › Fire Bucket › Quantity
Issued 29 June 2016
Resolved
Provide 3 properly labeled fire buckets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 June 2016
Resolved
Secure wire supports with proper fittings every 24 inches in ENG and under panel at operating station.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 29 June 2016
Resolved
Provide caulking around Windows where leaks were evident.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 29 June 2016
Resolved
Unable to conduct drills underway due to generator and ENG problems.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 7 October 2016
Resolution: Re-issued activity 6007573.