LYNNE FRINK is a 1980 oil recovery. The Coast Guard has recorded 76 inspections since 1981, most recently in October 2025, along with 68 deficiencies.

Records from 1981 to 2025. Most recent: inspection, 14 October 2025.

Built
1980
Last inspected
14 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8978459 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCC8505
Flag
UNITED STATES
303195000
Maury page id
psix-51364

Inspections, by type

…with no type recorded10
Years with a record 42 calendar years (1981–2025)
The 76 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)100.6 ft × 26.0 ft × 12.0 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)100.6 ft × 26.0 ft × 12.0 ft
ITC tonnagegross 212 / net 63
BuilderOFFSHORE TRAWLERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWARK, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 February 2026 · expires 28 February 2027
Service, as the file records itOil Recovery
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
212 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
63 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCC8505MMSI 303195000 · active · compulsorily equipped · granted 19 September 2018, expires 3 December 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 76

14 October 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8251406
26 June 2025 Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8167945
16 October 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8019594
25 October 2023 Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7813476
30 May 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7700326
10 November 2022 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7592068
24 September 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7319775
3 August 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7276529
3 August 2020 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7023887
4 June 2020 Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6962571
30 September 2019 Plan Review "T" Boat · Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6824970
8 August 2019 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6775656
9 August 2018 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6503463
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6505776
31 May 2018 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6423313
14 August 2017 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6240655
26 July 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5954900
18 August 2015 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5844580
25 August 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4979979
16 August 2011 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4124894
15 December 2010 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3906233
18 October 2010 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3882179
27 May 2008 Drydock Exam · Drydock Extension · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3219124
19 January 2007 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2858478
6 September 2006 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2772821
26 May 2005 Cargo Tank Internal · Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2407383
17 September 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2198029
20 July 2004 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2139220
12 August 2003 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1873013
21 May 2003 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1797839
8 August 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1658558
22 February 2002 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1488593
28 August 2001 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1076542
8 August 2001 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1068985
16 August 2000 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 821363
5 October 1999 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1194179
21 September 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1030871
24 August 1998 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 798500
18 May 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1445360
14 April 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1122971
19 March 1998 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1109516
4 September 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 787321
21 January 1997 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1098442
28 August 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1136232
6 September 1995 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1184964
27 April 1995 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1394317
9 September 1994 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1175213
7 September 1994 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1173775
17 December 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159570
3 November 1993 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 843824
8 September 1993 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1158442
5 August 1993 Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 844316
3 August 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358135
26 July 1993 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403657
20 May 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366841
14 October 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457069
28 September 1992 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 938702
20 September 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 85617
28 April 1992 COI Inspection · Deficiency Check · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265484
30 April 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1244607
16 November 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215717
21 June 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931677
2 May 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925320
20 September 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1311718
15 May 1989 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1342923
20 May 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888648
18 December 1987 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1321161
15 May 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335544
9 June 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298451
14 May 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992360
20 March 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309223
25 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286699
6 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978918
18 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968160
17 June 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963520
27 May 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1271926

Deficiency record · 68

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 October 2025 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel and mooring lines necessary for the vessel to be safely anchored or moored. Vessel's forward winch/capstan is inoperable. Repair to the satisfaction of MI. 46 CFR 184.300
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2025
Resolved 6 November 2025
Resolution: Verified capstan was repaired and fully operational
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 14 October 2025 Resolved
The owner of a vessel shall ensure that vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel’s master key of which access shall only be available to the individuals… establish a list of all crew, identified by position, allowed to access and use the master key and maintain such list upon the vessel. Vessel does not have a master key control log. Provide a master key control log to satisfaction of MI. 46 USC 3106
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2025
Resolved 6 November 2025
Resolution: Vessel provided a master key control log
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 October 2025 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 PSI at the pump outlet. During the testing, the pressure gauge at the fire pump outlet was observed at 50 PSI. Repair/replace gauge and/or fire pump and demonstrate adequate pressure to satisfaction of the MI. 46 CFR 181.10-1(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2025
Resolved 6 November 2025
Resolution: Replaced gauge. Verified adequate pressure
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2025 Resolved
All wiring and cables shall be suitable for marine service… cable must be constructed in accordance with U.S. Navy standards, institute of Electrical and Electronic Engineers [name withheld] 45 or be a suitable commercial grade cable, with stranded conductors, that is UL listed and rated for at least 75 degrees Celsius. Observed ROMEX solid core wiring in lower berthing room above water heater. Replace all ROMEX wiring onboard with marine grade wiring to satisfaction of MI. 46 CFR 183.10-20(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2025
Resolved 6 November 2025
Resolution: All ROMEX wire replaced with approved marine grade wire
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 14 October 2025 Resolved
Spaces containing machinery shall be fitted with adequate drip roof ventilators, trunks, louvers, etc. to provide sufficient air for proper operation of main engines and auxiliary engines. During inspection, a portable exhaust fan was found installed in exhaust ducting of the engine room. Remove portable fan and replace to original plans. 46 CFR 182.20-45(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2025
Resolved 6 November 2025
Resolution: Verified portable fan was removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2025 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Drive oil hose was found deteriorated on starboard main engine. Replace hose to satisfaction of MI. 46 CFR 185.05-1(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2025
Resolved 6 November 2025
Resolution: Drive oil hose replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 October 2025 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Hydraulic fittings were found leaking on hydraulic reservoir in engine room. Repair/replace hydraulic fittings to stop leaks to satisfaction of MI. 46 CFR 182.10-1(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2025
Resolved 6 November 2025
Resolution: Hydraulic fitting replaced, verified no leaks
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspector. Ground detection panel indicates a ground fault within the electrical system. Locate ground fault and repair to satisfaction of MI. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2025
Resolved 6 November 2025
Resolution: Verified ground fault was repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2025 Resolved
Receptacle outlets and attachment plugs for the attachment of portable lamps, tools, and similar apparatus supplies as ship's equipment shall provide a grounding pole and grounding conductor in the portable cord. Outlet is forepeak was found with grounding conductor broken off in receptacle. Replace receptacle to satisfaction of MI. 46 CFR 183.10-20(o)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2025
Resolved 6 November 2025
Resolution: Receptacle replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2023 Resolved
All pressure vessels must be provided with protective devices. Start air PV relief valve did not re-seat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 17 November 2023
Resolution: Witnessed new relief valve. Valve was tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2023 Resolved
Where flexible non-metallic hose is permitted for use in piping systems by this section it must meet SAE J-1942. Stbd MDE fuel hose had a cracked outer jacket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2023
Resolved 17 November 2023
Resolution: Witnessed new hose installed. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 November 2022 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vsl missed their annual inspection due to repairs being made on the starboard main engine. Contact USCG Sector Delaware Bay to schedule annual inspection when vsl is fully operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2022
Resolution: Annual Insp Completed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 August 2021 Resolved
Fire extinguisher was not securely held as the bracket was not an approved bracket per the manufacturer. Provide and install approved bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2021
Resolved 24 September 2021
Resolution: Correct bracket was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 3 August 2021 Resolved
Water heater in lower accommodation closet had a relief device that was capped. The cap was removed prior to the end of the inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2021
Resolution: Removed prior to the end of the inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 3 August 2021 Resolved
183.10-45 (1): Vessel had 01 fridge door that did not have a locking device to prevent door from swinging open. Doors shall be provided with hinges or locking devices to prevent accidental opening. 10-C corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 3 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 August 2021 Resolved
Vessel crew was not able to line up the bilge suction in the E/R without second guessing the valves. This is concerning with regard to crew competency (only 02 crew members are regularly with the vessel, the deck hands are hired on an as needed basis when the vessel is awarded a contract for work). Vessel shall provide diagram or instructions with labeled valves so that any crew member is able to line up the bilge system for suction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2021
Resolved 18 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 August 2020 Resolved
02 survival craft had improperly configured hydrostatic releases that did not provide a connection to the vessel.
Action required: 10 - Deficiency Rectified
Resolved 3 August 2020
Resolution: Cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 3 August 2020 Resolved
Water heater on lower deck relief valve discharges through the hull via a stop valve. Relief valves are not to have valves installed. Propose alternate arrangement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 September 2020
Resolution: Received pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020 Resolved
For the battery stored in upper deck storage box: Provide battery charger make/model information to include power output of the battery charger in order to determine the requirements for this installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 September 2020
Resolution: Received pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020 Resolved
Vessel has been outfitted with new switchboard. This office has no record of plan approval for this installation. Provide proof of approval.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2022
Resolution: Approved documents uploaded into MISLE
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 August 2019 Resolved
Stern sight gauges for fuel day tank made out of flexible clear plastic/rubber hose. Replace sight gauge with sight gauges made of heat resistant material.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2019
Resolution: New sight gauge made from butyrate tubing installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 August 2019 Resolved
Install plugs in the bottom of both fuel strainer bowls on port main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2019
Resolution: Plugs installed
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 August 2019 Resolved
Program MMSI number into primary VHF-DSC radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2019
Resolution: MMSI number programmed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 August 2019 Resolved
Provide FCC Safety Radio Certificate and Bridge-to-Bridge Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2019
Resolution: Updated FCC certificates provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2019 Resolved
Secure and install cover for junction box located under main steering console.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2019
Resolution: Junction box cover installed.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 8 August 2019 Resolved
Install latch for oven door.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2019
Resolution: Oven door latch installed
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
Vsl is broadcasting: No AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 6 November 2018
Resolution: AIS information updated.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 August 2018 Resolved
The rescue boat was not onboard during man overboard drills. the vessel's procedures include the use of a rescue boat. the vessel is required a rescue boat when underway.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 August 2018
Resolution: The rescue boat was placed on the vessel
Fire Fighting › Fire Hydrants › Condition
Issued 18 August 2015 Resolved
JE01 Replace valve handle on starboard side fire hydrant
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 25 August 2015
Resolution: Received email photo of new hydrant valve installed.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 18 August 2015 Resolved
JE02 Ensure proper means of locking overboard discharge for MSD
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 25 August 2015
Resolution: Overboard discharge valve was in the closed position and handle was removed and secured in vicinity of valve.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 18 August 2015 Resolved
JE03 Provide a current copy of NAV Rules
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 25 August 2015
Resolution: Received email photo of current copy of NAV Rules on board vessel.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 August 2015 Resolved
JE 04 Provide DAPI enrollment information
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 25 August 2015
Resolution: Received a copy of members DAPI enrollment certificate.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 25 August 2014 Resolved
Liferafts were out for service. MSC loaner liferaft was onboard at time of inspection.
Due 1 September 2014
Resolved 28 August 2014
Resolution: Vessel emailed servicing invoice and photos of liferafts properly installed. [name withheld] visually confirmed proper installation on 08SEP2014
Communications › Radio Communications › VHF Radiotelephone
Issued 25 August 2014 Resolved
Emergency broadcast placard was not the vessel
Condition: Improper Installation
Due 1 September 2014
Resolved 8 September 2014
Resolution: [name withheld] provided vessel with a self adhesive emergency broadcast placard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 December 2010 Resolved
Proof of enrollment missing.
Action required: 705 - Other - as specified
Resolved 14 January 2011
Resolution: Proof of employee enrollment in program provided to MI.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 December 2010 Resolved
Wire on battery controller is not approved boat cable.
Action required: 705 - Other - as specified
Resolved 14 January 2011
Resolution: Boat cable installed, all sat.
Communications › Radio Communications › EPIRB
Issued 15 December 2010 Resolved
Missing proof of current registration. Vessel restricted to within 3NM of shore.
Action required: 705 - Other - as specified
Resolved 14 January 2011
Resolution: Proof of current EPIRB registration provided to MI.
Construction/Loadline › Hull › Bottom Plating
Issued 18 October 2010 Resolved
Wasted area of hull plating found in aft stbd quarter of E/R. Crop and renew wasted area of hull.
Action required: 705 - Other - as specified
Resolved 10 November 2010
Resolution: Wasted area replaced.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 25 August 2005 Resolved
PROVE PROPER OPERATION OF SSB RADIO.
Action required: 705 - Other - as specified
Resolved 17 November 2005
Resolution: WITNESSED SAT RADIO CHECK
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 August 2005 Resolved
PROVIDE CURRENT EYE WASH FOR MEDICINE KIT.
Due 8 September 2005
Resolved 7 September 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 August 2005 Resolved
MAKE STERN LIGHT OPERABLE. VESSEL NOT ALLOWED TO OPERATE BETWEEN SUNSET AND SUNRISE.
Action required: 705 - Other - as specified
Resolved 17 November 2005
Resolution: WITNESSED PROPER OPERATION
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 September 2004 Resolved
Line connecting water light to life ring is wasted and needs to be replaced.
Condition: Improper/Lack of Maintenance
Due 16 October 2004
Resolved 21 October 2004
Resolution: Replaced line with new.
Lifesaving › Inflatable Liferafts › Markings
Issued 17 September 2004 Resolved
Instructions for launching liferaft needs to be mounted permanetly to the ship.
Due 16 October 2004
Resolved 21 October 2004
Resolution: mounted placard to ship in area of life raft.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 17 September 2004 Resolved
Emergency exit in E/R needs to be properly labeled.
Due 16 October 2004
Resolved 21 October 2004
Resolution: Labled exit in E/R.
Lifesaving › Inflatable Liferafts
Issued 8 August 2002 Resolved
Provide vessel with two 15 man serviced life rafts with serviceable hydrostatic releases, prior to carrying passengers.
Due 9 September 2002
Resolved 16 August 2002
Resolution: Serviced life rafts installed with new hydro releases.
Lifesaving › Rescue Boat
Issued 8 August 2002 Resolved
Stencil rescue boat with number of persons allowed and provide retro where needed IAW 46CFR185.604. LEGACY COMPONENT DESC: Capacity
Due 9 September 2002
Resolved 16 August 2002
Resolution: Has been determined since vessel does not carry passengers boat will remain as a work boat.
Lifesaving › Visual Distress Signals (General)
Issued 8 August 2002 Resolved
Provide EPIRB with serviceable hydrostatic release. Vessel restricted to 3 NM from shore.
Due 9 September 2002
Resolved 16 August 2002
Resolution: New hydrostatic release installed.
Navigation › Piloting/Steering
Issued 8 August 2002 Resolved
Provide the required up to date charts for vessel operations. LEGACY COMPONENT DESC: Marine Charts
Due 9 September 2002
Resolved 16 August 2002
Resolution: New charts purchased by master
Lifesaving › Hand Flares
Issued 22 February 2002 Resolved
replace expired smokes and flares. LEGACY COMPONENT DESC: smokes and flares
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2002
Resolved 22 February 2002
Resolution: replaced with new.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 February 2002 Resolved
replace frayed handline on port ring buoy.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2002
Resolved 22 February 2002
Resolution: replaced line with new.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 22 February 2002 Resolved
Mark emergency exit in crew's accomdation space with "EMERGENCY EXIT, KEEP CLEAR"
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2002
Resolved 22 February 2002
Resolution: owner stincled at proper location.
Lifesaving
Issued 28 August 2001 Resolved
Replace expired orange smokes (6 ea).
Condition: Unknown
Due 28 September 2001
Resolved 26 September 2001
Lifesaving
Issued 28 August 2001 Resolved
replace deteriorating hand on ring buoy on port side pilot house.
Condition: Unknown
Due 28 September 2001
Resolved 26 September 2001
Accommodation/Occupational Safety
Issued 28 August 2001 Resolved
mark emergency exit in crews accomadation space with "EMERGENCY EXIT, KEEP CLEAR".
Condition: Unknown
Due 28 September 2001
Resolved 26 September 2001
Electrical
Issued 21 September 1999 Resolved
REMOVE MOUNTED HOUSEHOLD FANS AND EXTENSION CORDS FROM ENGINE ROOM.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Navigation
Issued 21 September 1999 Resolved
REPAIR AND DEMONSTRATE OPERATION OF VESSEL'S SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Electrical
Issued 21 September 1999 Resolved
INSTALL BLANKS IN BOTH 208VAC ELECTRICAL PANEL BOXES IN THE ENGINE ROOM.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Lifesaving
Issued 21 September 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Lifesaving
Issued 8 September 1993 Resolved
Prior to transfer of any oil cargo between vessels or shore, obtain_x001C_ approved transfer procedures.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Deck/Cargo
Issued 8 September 1993 Resolved
Oil recovery is limited to grade D and lower cargoes and weathered crude oil until the comments in the Marine Safety Ctr letter ser C-30409 dated _x001C_ 27 Aug 93 are resolved.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Deck/Cargo
Issued 8 September 1993 Resolved
Provide a crane capacity chart at the crane operator's station. The max lift is limited to 3500 lbs.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Fire Fighting
Issued 8 September 1993 Resolved
Properly mount the two loose BII fire extinguishers.
Condition: Unknown
Due 8 September 1993
Resolved 8 September 1993
Engineering
Issued 30 April 1991 Resolved
PROVIDE AND PROVE OPERATION OF STARTS AND STOPS FOR MAIN ENGINES IN WHEELHOUSE OR PROVIDE COMMUNICATIONS FROM WHEELHOUSE TO ENGINE ROOOM.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Fire Fighting
Issued 2 May 1990 Resolved
REPAIR PIPING ON FIRE MONITOR.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Navigation
Issued 2 May 1990 Resolved
REPAIR OR REPLACE SSB RADIO.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Documentation
Issued 15 May 1989 Resolved
UPDATE FUEL OIL TRANSFER PROCEDURES AS PER 33 CFR 155.750. COMPLY BY: 01JUN89
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Engineering
Issued 15 May 1989 Resolved
PROVIDE M/E SHUT DOWN ON BRIDGE AS PER 46 CFR 175.10-29 AND 46 CFR 184.35-1. COMPLY BY: 01JUN89
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989
Engineering
Issued 27 May 1981 Resolved
RENEW FLAME SCREEN TO #3 FUEL OIL TANK VENT.
Condition: Unknown
Due 27 May 1981
Resolved 27 May 1981