← All vessels
HOT PURSUIT
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northwest District (CGD-NW) · Other hulls named HOT PURSUIT
HOT PURSUIT is a 1977 passenger vessel (inspected). The Coast Guard has recorded 68 inspections since 1985, most recently in May 2026, along with 69 deficiencies and 2 casualty investigations between 2007 and 2011.
Records from 1985 to 2026. Most recent: inspection, 23 May 2026.
- Built
- 1977
- Last inspected
- 23 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 69 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2007–2011
Identity
582113
WDD7629
51367
Flag
UNITED STATES
368257020
Maury page id
psix-51367
Inspections, by type
…with no type recorded11
Years with a record
37 calendar years (1985–2026)
The 68 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)41.5 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES INC · SEATTLE, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWESTPORT, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 2 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM9908MMSI 368257020 · active · compulsorily equipped · granted 18 May 2022, expires 18 May 2032
WDD7629MMSI 367189050 · expired · compulsorily equipped · granted 22 May 2007, cancelled 22 July 2017
WDA5456MMSI 366820280 · expired · compulsorily equipped · granted 24 July 2001, cancelled 24 September 2011
WUT2073MMSI 366743780 · cancelled · compulsorily equipped · granted 21 December 1998, cancelled 29 June 2001 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 68
23 May 2026
Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 8379249
17 September 2025
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8235485
20 March 2025
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8097301
13 September 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8003423
12 April 2024
Deadweight Survey · Inclining Experiment
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7895831
25 September 2023
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7811933
29 March 2023
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7659408
27 April 2022
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7442314
6 April 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7170411
2 March 2021
Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7150188
14 July 2020
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7007756
6 May 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6683380
6 May 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6688672
10 January 2019
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6609133
18 May 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6418064
4 May 2017
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6149149
28 November 2016
Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6047408
15 August 2011
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4302297
8 February 2011
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3941751
24 September 2010
Hull Examination · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3858134
2 March 2010
COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3684218
23 September 2008
COI Inspection · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3326258
1 April 2008
Annual Inspection · Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3174962
4 September 2007
Deficiency Check · Examination of Repairs
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3049795
3 September 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3049018
24 May 2007
Hull Examination · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2905482
26 April 2007
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2916489
27 April 2006
Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2672311
6 May 2005
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2578800
3 May 2004
Annual Inspection · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2087952
24 June 2003
Examination of Repairs
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1825646
9 May 2003
COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1805668
19 October 2002
Re-Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1693453
16 July 2001
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1393730
10 May 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 167934
4 January 2001
COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1361906
6 January 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 814830
8 April 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 786722
25 January 1999
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805267
12 January 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 810654
5 January 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 810665
8 July 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1130533
27 January 1998
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1339185
4 February 1997
Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1459287
31 January 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 884129
2 February 1995
Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1138869
25 January 1995
Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1138293
7 February 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 855219
9 February 1993
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 830148
20 January 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1140280
4 February 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 952981
4 February 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1226566
27 December 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1228715
14 December 1990
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 922571
16 March 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 923876
28 February 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1239967
12 May 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 969831
16 February 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1349684
3 February 1989
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1209233
6 January 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 888716
22 December 1988
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1196141
21 January 1988
Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1322994
5 February 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1009176
23 January 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1004464
5 February 1986
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1302554
10 January 1986
Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1296483
5 July 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 981445
30 May 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 978560
Deficiency record · 69
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2022
Resolved
A vessel must have one or more ring life buoys as follows: (2) A vessel of more than 7.9 meters (26 feet) in length but not more than 19.8 meters (65 feet) must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Vessel had 02 life buoys on board.
(b) Each ring life buoy on a vessel must: (1) Be approved in accordance with 160.050 in subchapter Q of this chapter.
02 Ring lifebuoys on board have deteriorated past point of intended function. Replace.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 June 2022
Resolved
An adult lifejacket must be provided for each person carried onboard. 06 lifejackets were deteriorated and no longer able to provide proper flotation. Limit number of passengers onboard to 19 and replace deteriorated lifejackets.
705c: Limit number of passengers onboard to number of servicable lifejackets available for use, 19 passengers.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 June 2022
Resolved
The person in command of a documented vessel must have onboard that vessel the original Certificate of Documentation currently in effect for that vessel. Vessel owner does not have current COD. Application has been submitted to NVDC and is awaiting processing.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 April 2022
Resolved
Life raft needs to be repacked.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 November 2016
Resolved
Re-Issued CG-835; COI Inspection including drills, required prior to returning to passnger service. (Vessel currently in lay up status)
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 September 2010
Resolved
Prior to carrying passengers vessel must make repair to hand rail stanchion on port side were it connects to the deck.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 March 2010
Resolved
Conduct underway drills and sea trials to the satisfaction of attending Coast Guard Marine Inspector. The vessel is currently out of service.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 2 March 2010
Resolved
Remove Romex solid wire from vessel. Romex observed in accomodation space (fwd) and aft deck lighting. To be completed no later than next dry dock. 120vac only used while inport.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 March 2010
Resolved
Stock first aid kit with eyewash.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 March 2010
Resolved
Renew expired alcohol swabs.
Engineering › Bilge Water Management System › Strainer
Issued 2 March 2010
Resolved
Accomodation space bilge suction missing suction screen. Renew with proper foot valve strainer.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 2 March 2010
Resolved
Renew expired EPIRB hydrostatic release unit. Vessel not able to operate on the high seas until corrected.
Engineering › Steering Gear System › Fastener
Issued 4 September 2007
Resolved
Make proper repairs to the steering system, to the satisfaction of the attending USCG Marine Inspector, prior to the carriage of passengers.
Communications › Radio Communications › VHF Radiotelephone
Issued 27 April 2006
Resolved
Provide current FCC safety certificate.
Stability › Unintentional Flooding › General
Issued 27 April 2006
Resolved
Make collision bulkhead watertight.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 April 2006
Resolved
Replace three adult life jackets.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 May 2004
Resolved
Post permanent COI
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 May 2004
Resolved
Post COD
Documentation › Certificates/Documents › FCC SSL
Issued 3 May 2004
Resolved
Provide Communication Act Certificate
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 3 May 2004
Resolved
Provide list of names in 2004 consortium
Personnel › Certificates/Documents/Licenses › License, Master
Issued 3 May 2004
Resolved
Provide current operator license
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 3 May 2004
Resolved
Service portable and fixed fire extinguishers LEGACY COMPONENT DESC: Service
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 May 2004
Resolved
Repair inoperative stern light
Communications › Audible Communications
Issued 3 May 2004
Resolved
Provide horn & bell LEGACY COMPONENT DESC: Horn/Whistle/Bell
Lifesaving › Hand Flares › Quantity
Issued 3 May 2004
Resolved
Provide 3 orange smoke flares
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 3 May 2004
Resolved
Label WT hatch- keep closed
Fire Fighting › Grease Extraction Hood › General
Issued 3 May 2004
Resolved
Request waiver for grease extraction hood LEGACY COMPONENT DESC: waiver
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 3 May 2004
Resolved
Provide 8 adult Type 1 PFD's. Total persons reduced to 17 until corrected.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 9 May 2003
Resolved
Supply 4 additional life preservers. Until additional life presevers are supplied, number of people on board is limited to 21.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 9 May 2003
Resolved
Ensure life raft is on board and properly mounted.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 May 2003
Resolved
Mark life preservers with vessel's name
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 May 2003
Resolved
Mark life ring with vessel name
Communications › Radio Communications › EPIRB
Issued 9 May 2003
Resolved
Repair/replace EPIRB hydrostatic release
Documentation › Markings/Placards
Issued 9 May 2003
Resolved
Mount life jacket donning and life raft launching placards.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 9 May 2003
Resolved
Provide proper ground tackle
Engineering › Fuel Oil Service System › Valve
Issued 9 May 2003
Resolved
Repair/replace emergency fuel shuttoff livkage
Stability › Watertight Integrity
Issued 9 May 2003
Resolved
Re-seal Fore peak access in collision bulkhead
Documentation › Markings/Placards
Issued 9 May 2003
Resolved
Lable emergency fuel shuttoff valve locations
Documentation › Markings/Placards
Issued 9 May 2003
Resolved
Label emergency escape hatch
Engineering
Issued 2 February 1995
Resolved
REINSTALL BOTH PROPS, PROVIDE SERVICING REPORT AND PHOTO OF COMPLETED WORK.
Navigation
Issued 25 January 1995
Resolved
SEAL NAV LIGHTS, LOOSE LENSE
Lifesaving
Issued 25 January 1995
Resolved
BROKEN SNAP ON WAIST BAND_x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 25 January 1995
Resolved
GUARD OVER PUMP BELT_x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 25 January 1995
Resolved
REPAIR/REPLACE WORN BOARDING LADDER
Accommodation/Occupational Safety
Issued 14 December 1990
Resolved
RENEW FLAME SCREENS FOR MSD TANK VENTS PORT AND STBD WITH 30X30 MESH_x001C_ SCREEN.
Accommodation/Occupational Safety
Issued 14 December 1990
Resolved
PROVIDE SECURING DEVICE FOR 3/4" MSD OVERBOARD VALVE STBD SIDE.
Construction/Loadline
Issued 14 December 1990
Resolved
RENEW GASKETS ON ENGINE SPACE HATCHES.
Engineering
Issued 28 February 1990
Resolved
INSTALL GUARDS TO COVER INBOARD PULLEYS ON MAIN DIESEL ENGINES IN WAY OF WALKWAY.
Lifesaving
Issued 3 February 1989
Resolved
RENEW GRABLINE ON 20 PERSON B/A
Lifesaving
Issued 3 February 1989
Resolved
PROVIDE ONE APPROVED ADULT PFD
Engineering
Issued 3 February 1989
Resolved
MARK FUEL SHUT-OFFS ON DECK
Construction/Loadline
Issued 3 February 1989
Resolved
INSTALL HOLD DOWNS FOR ENGINE HATCHES
Construction/Loadline
Issued 3 February 1989
Resolved
INSTALL AFT HATCH KEEPER LINE
Construction/Loadline
Issued 22 December 1988
Resolved
MAKE AVAILABLE FOR INSPECTION THE AREA FWD OF COLLISION BLKHD. AREA AT PRESENT HAS ONLY A 6" OPENING ON MAIN DECK.
Engineering
Issued 22 December 1988
Resolved
REPAIR OR REPLACE PORT AND STBD SHAFTS. SHAFTS ARE WORN AT CUTLASS AREA ANDPACKING GLAND AREA. SHAFT ON PORT SIDE IS PITTED FROM ELECTROLYSIS AT GLAND AREA.
Engineering
Issued 22 December 1988
Resolved
REALIGN STRUTS TO ENGINE FLANGE. OPENING THROUGH HULL IS OFF FROM STRUT BY 3/8" - 1/2".
Engineering
Issued 22 December 1988
Resolved
REPAIR OR REPLACE CRACKED CASTING FOR ENGINE TO SHAFT COUPLING.
Construction/Loadline
Issued 21 January 1988
Resolved
1 REPLACE 3/4 INCH GATE VALVE ON BAIT TANK INLET.
Construction/Loadline
Issued 21 January 1988
Resolved
2 REPLACE 1 1/2 INCH GATE VALVE FOR MSD DISCHARGE.
Engineering
Issued 21 January 1988
Resolved
3 REPLACE 3 ELBOWS ATTACHED TO COOLING WATER STRAINERS.
Engineering
Issued 21 January 1988
Resolved
4 INSTALL STRAINER ON BILGE SUCTION PIPE IN LAZARETTE.
Accommodation/Occupational Safety
Issued 23 January 1987
Resolved
PROVIDE LOCKING DEVICE ON MSD OVBD DISCHARGE.
Fire Fighting
Issued 23 January 1987
Resolved
HAVE FIRE-EXTINGUISHER SERVICED. (ENGINEROOM COMPARTMENT)
Engineering
Issued 30 May 1985
Resolved
REPAIR LEAK ON STARBOARD ENGINE OUTBOARD EXHAUST COOLING FLEX HOSE.
Unknown
Issued 30 May 1985
Resolved
OBTAIN A CURRENT COPY OF THE RULES OF THE ROAD.
Electrical
Issued 30 May 1985
Resolved
REMOVE WIRE NUTS ON FRESH WATER PUMP AND REPLACE WITH INSULATED PRESSURE WIRE CONNECTORS.
Electrical
Issued 30 May 1985
Resolved
INSTALL INSULATED PRESSURE WIRE CONNECTORS ON BAIT TANK PUMP LOCATED IN THE ENGINE ROOM, PORT SIDE, AFT.
Engineering
Issued 30 May 1985
Resolved
MOUNT BOTH MAIN ENGINE SEA STRAINERS TO FORWARD BULKHEAD OF ENGINE ROOM.
Accommodation/Occupational Safety
Issued 30 May 1985
Resolved
REPAIR ALL LEAKING FITTINGS ON MSD HOSES AND PIPING IN HOLDING TANK COMPARTMENT.
Casualty record · 2
3 September 2007Routine · role: Involved in a Marine Casualty · activity 3049018
15 August 2011Routine · role: Involved in a Marine Casualty · activity 4302297
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
NORTHERN (2007–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.