Records from 1985 to 2025. Most recent: inspection, 29 October 2025.
Inspection history · 75
29 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8260489
3 June 2024
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7938446
29 August 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7887008
22 March 2023
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7679828
4 March 2022
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7405774
14 July 2021
Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7255683
25 June 2021
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7235529
19 November 2019
Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6860505
14 March 2019
Drydock Exam · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6642682
25 January 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6343599
1 November 2017
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6299069
31 October 2017
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6298900
3 August 2016
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5961283
25 July 2016
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5952546
3 November 2015
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5756104
20 October 2015
Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5746973
15 October 2014
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5005315
25 July 2012
Administrative Inspection · Inclining Experiment
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4391245
29 May 2012
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4328322
27 July 2011
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4094990
23 July 2011
Type not recorded
No type recorded · USCGC REEF SHARK (WPB 87371) · USCG Arctic District (CGD-A) · Activity 4091521
21 July 2011
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4094541
13 October 2010
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3868957
25 March 2009
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3439618
24 October 2008
Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3354466
17 April 2008
Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3186039
18 January 2007
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2857762
27 October 2006
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2809074
24 August 2006
Type not recorded
No type recorded · USCGC KODIAK ISLAND (WPB 1341) · USCG Southeast District (CGD-SE) · Activity 2762019
13 January 2006
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2572384
8 November 2005
Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2532195
12 March 2005
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2310621
16 November 2004
Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2242045
15 October 2004
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2221295
1 October 2003
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1917477
10 October 2002
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1687728
18 October 2001
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1612151
15 June 2001
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1065815
5 May 2001
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 81147
25 October 2000
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1366123
3 December 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1361289
7 December 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1421587
26 June 1998
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1446662
1 December 1997
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1381111
1 February 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1107356
2 December 1996
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1451119
10 June 1996
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1191678
2 June 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 183040
10 January 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 883357
5 December 1995
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1387897
5 July 1995
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1191549
2 December 1994
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1356923
28 July 1994
Hull Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1442189
2 December 1993
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1397988
13 July 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 844999
26 April 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 831970
19 April 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1366819
4 December 1992
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 830858
21 July 1992
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 947289
5 December 1991
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1264806
13 August 1991
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 938073
4 December 1990
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 922539
26 October 1990
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1230427
29 January 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1221562
27 December 1989
Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 914656
3 October 1989
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1319654
4 January 1989
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1043109
21 November 1988
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 893385
13 October 1988
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 892210
23 November 1987
Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1312172
29 October 1986
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1320871
25 September 1986
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1005900
10 July 1986
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1292949
29 October 1985
Credit Drydock
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 989399
17 July 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 982046
Communications › Visual Communication › Red Warning Signal
Issued 25 January 2018
Resolved
Provide total of 6 red flares.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 1 February 2018
Resolution: All red flares installed.
Communications › Radio Communications › EPIRB
Issued 25 January 2018
Resolved
Properly mount EPIRB.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 1 February 2018
Resolution: EPIRB properly mounted.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 3 August 2016
Resolved
Provide means of securing engine room ventilation.
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 18 August 2016
Resolution: Corrected with installation of foam plugs.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 August 2016
Resolved
Provide GPS embeded DSC radio.
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 18 August 2016
Resolution: New radio installed and programmed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 August 2016
Resolved
Provide ne hose clamps fo rexhaust piping in way of muffler.
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 18 August 2016
Resolution: New hose clamps installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 August 2016
Resolved
Provide guard for fan belt on main diesel engine.
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 18 August 2016
Resolution: Guard installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 3 August 2016
Resolved
Provide 3rd required B-II extinguisher.
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 18 August 2016
Resolution: New fire extinguisher installed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 October 2015
Resolved
Provide log for training and EPIRB testing.
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 3 November 2015
Resolution: Drills, Training and EPIRB log started.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 21 October 2015
Resolved
Make fuel tank vent in accordance with 46CFR 182.450
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 3 November 2015
Resolution: Fuel tank vent properly arranged.
Engineering › Reduction Gearing/Clutches › Bolt
Issued 21 October 2015
Resolved
Repair/replace shift linkage on reduction gear.
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 3 November 2015
Resolution: Linkage replace with new hardware.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 21 October 2015
Resolved
Print and post emergency instructions.
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 3 November 2015
Resolution: Emergency Instructions posted.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 October 2015
Resolved
Properly support raw water cooling lines for reduction gear.
Action required: 705 - Other - as specified
Due 6 November 2015
Resolved 3 November 2015
Resolution: Piping properly supported and cordage removed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 15 October 2014
Resolved
Remove excessive oil from bilges.
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 13 November 2014
Resolution: Excessive oil removed from bilge.
Engineering › Fuel Oil Service System › Piping
Issued 15 October 2014
Resolved
Repair or replace leaking fuel line at fuel filter.
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 13 November 2014
Resolution: Leak repaired at fuel line.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 October 2014
Resolved
Remove or properly terminate dead-end wiring in engine room.
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 6 November 2014
Resolution: Dead end wires removed from compartment.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 October 2014
Resolved
Provide water light for ring buoy. Vessel restricted to daylight operations until cleared.
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 13 November 2014
Resolution: New water light installed.
Construction/Loadline › Structures › Deck Plating
Issued 29 May 2012
Resolved
Noted crack in fiberglass on the underside of the swim platform in the center. Crack shows running rust from the bolt from which the crack is promulgated. Make permanent repairs to fiberglass swim platform prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2012
Resolution: Obsvd repairs to crack in the platform.
Construction/Loadline › Structures › Deck Plating
Issued 29 May 2012
Resolved
Deck is cracked in overhead (upper deck) at the joint between two FRP molds, directly in the center, next to where the lifejackets are stowed on the underside. Make permanent repairs to the fiberglass prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2012
Resolution: Obsvd repairs to fiberglass in way of the crack in overhead. All sat.
Construction/Loadline › Structures › Deck Plating
Issued 29 May 2012
Resolved
The deck where the rail stanchion is screwed in is waterlogged and soft. The rail does not offer much support. Cut back to good wood and make permanent repairs to the fiberglass.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2012
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 May 2012
Resolved
Transverse bulkhead between the lazarette and space containing the fuel and water tanks is completely waterlogged and delaminated, bulginig on the sides of both spaces across the span of the entire bulkhead. Cut out bulkhead and make permanent repairs to bulkhead in accordance with original scantlings.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2012
Resolution: Installed all new bulkhead. All sat.
Construction/Loadline › Structures › Deck Plating
Issued 29 May 2012
Resolved
Main deck starting at the separation between the engine room and space containing the fuel and water tanks shows significant signs of water intrusion and is soft in many spots. Vsl owner is to replace said decking according to original scantlings prior to August 31, 2012.
Condition: Improper/Lack of Maintenance
Due 31 August 2012
Resolved 2 July 2012
Resolution: All new decking installed. All sat.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 July 2011
Resolved
Provide and install a corrosion-resistant clip to the ring buoy floating waterlight painter as per 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 31 July 2011
Resolved 16 November 2011
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 July 2011
Resolved
Provide and install a lanyard of at least three (3) feet in length but not more than six (6) feet for the ring buoy floating waterlight as per 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 31 July 2011
Resolved 16 November 2011
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 July 2011
Resolved
Hard splice ring buoy lanyard to floating waterlight, corrosion resistant clip and ring buoy lifeline.
Action required: 705 - Other - as specified
Due 31 July 2011
Resolved 16 November 2011
Lifesaving › Hand Flares › Quantity
Issued 27 July 2011
Resolved
Provide a total of six (6) hand orange smoke distress signals as per 46 CFR 180.68(a).
Action required: 705 - Other - as specified
Due 31 July 2011
Resolved 16 November 2011
Documentation › Certificates/Documents › FCC SSL
Issued 27 July 2011
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 31 July 2011
Resolved 16 November 2011
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 13 October 2010
Resolved
Prior to credit hull examination, renew shaft cutlass bearing.
Action required: 705 - Other - as specified
Due 13 October 2010
Resolved 27 October 2010
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 13 October 2010
Resolved
Prior to credit hull examination, renew shaft pedestal bearing and ensure mounting supports same.
Action required: 705 - Other - as specified
Resolved 27 October 2010
Stability › Watertight Integrity › General
Issued 13 October 2010
Resolved
Prior to carrying passengers, provide and install access panel/plate for collision bulkhead and ensure bulkhead is watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2010
Resolved 27 October 2010
Stability › Watertight Integrity › General
Issued 13 October 2010
Resolved
Prior to carrying passengers, seal all watertight bulkhead openings and penetrations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2010
Resolved 13 October 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 October 2010
Resolved
Prior to carrying passengers, double up metal clamps for each end of all propulsion engine exhaust rubber hoses.
Action required: 705 - Other - as specified
Due 13 October 2010
Resolved 27 October 2010
Stability › Unintentional Flooding › General
Issued 13 October 2010
Resolved
Prior to carrying passengers, provide a metallic positive closure valve for all bilge thru-hulls and all others located within 6" of the deepest loaded waterline.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2010
Resolved 27 October 2010
Documentation › Markings/Placards › Capacity Marking
Issued 25 March 2009
Resolved
Vessel not marked with maximum passenger capacity on upper deck. Ensure upper deck is marked for maximum number of passengers.
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 23 July 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 March 2009
Resolved
All PFD's found soiled or mildewed and two were found to be unserviceable. Clean all using approved method and replace unserviceable ones. Until two are replaced, total passenger capacity shall be reduced to 35.
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 23 July 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 March 2009
Resolved
Ring buoy found to not have 60 foot buoyant, UV resistant, lifeline. Ensure ring buoy is properly outfitted with required lifeline.
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 23 July 2009
Lifesaving › Hand Flares › Storage
Issued 25 March 2009
Resolved
Flares not stowed in proper container. Ensure flares are stowed in brightly colored, portable, watertight container marked "Distress Signals"
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 23 July 2009
Fire Fighting › Fire Bucket › Availability
Issued 25 March 2009
Resolved
Vessel equipped with inoperable fire pump. Vessel not required to have fire pump on board but must at least have fire buckets. Either ensure the fire pump is properly functioning or remove the pump and provide three 2.5 gallon fire buckets, with 4 foot lanyard, and marked "FIRE BUCKET".
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2009
Resolved 25 March 2009
Resolution: Resolved prior to completion of inspection.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 March 2009
Resolved
Vessel found to contain excessive amount of un-necessary maintenance, old parts, and repair materials. Remove all un-necessary items.
Action required: 705 - Other - as specified
Due 25 March 2009
Resolved 23 July 2009
Engineering › Bilge Water Management System › Valve
Issued 25 March 2009
Resolved
Bilge discharge hoses for fuel tank compartment and accommodation space found to be installed w/out a positive shutoff valves. Insure both bilge hoses are equipped with the required means of closure.
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 23 July 2009
Engineering › Bilge Water Management System › Hose
Issued 25 March 2009
Resolved
Hose from formerly installed bilge pump found still installed to the through-hull fitting in the fuel tank compartment. Either remove the hose and securely cap the through-hull fitting temporarily until removal is possible or install an additional bilge pump and attach the installed hose.
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 23 July 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 March 2009
Resolved
Access to remote fuel shut-off found to not be clearly marked on the outside of the access. Ensure the fuel shut-off is clearly and legibly marked as required.
Action required: 705 - Other - as specified
Due 1 April 2009
Resolved 23 July 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 March 2009
Resolved
Vessel found to have an excessive amount of dead-end wiring. Vessel owner/Operator shall make an effort to remove a significant amount of un-necessary wiring from the vessel over the next year. All remaining wiring shall be installed and supported as required by regulations. This deficiency shall be due on the anniversary date of the COI (19Jan2010) and will be evaluated at that time.
Action required: 705 - Other - as specified
Due 19 January 2010
Resolved 23 July 2009
Lifesaving › Hand Flares › Quantity
Issued 17 April 2008
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE THREE (3) VALID ORANGE SMOKE HAND FLARES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2008
Resolved 17 April 2008
Communications › Radio Communications › EPIRB
Issued 17 April 2008
Resolved
PRIOR TO CARRYING PASSENGERS, RENEW HRU FOR EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2008
Resolved 17 April 2008
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 17 April 2008
Resolved
IMPLEMENT A COMPANY DRUG AND ALCOHOL TESTING PROGRAM AS PER 46 CFR 16, 46 CFR 4.06, 49 CFR 40 AND 33 CFR 95.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2008
Resolved 24 October 2008
Resolution: Corrected
Personnel › Certificates/Documents/Licenses › License, Master
Issued 18 January 2007
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE ALL DOCUMENTATION FOR VESSELS MASTER, RANDY VAN BELKEN.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 January 2007
Resolved 19 January 2007
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 18 January 2007
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROOF OF BASIC 95 STCW TRAINING FOR ALL CREWMEMBERS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 January 2007
Resolved 19 January 2007
Lifesaving › Buoyant Smoke Signals › General
Issued 18 January 2007
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE THREE (3) ADDITIONAL, VALID ORANGE HAND-HELD SMOKE PYROTECHNICS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 January 2007
Resolved 19 January 2007
Documentation › Certificates/Documents › FCC SSL
Issued 27 October 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2006
Resolved 29 November 2006
Engineering › Bilge Water Management System › Not Operational
Issued 27 October 2006
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE PROPER OPERATION OF HIGH BILGE WATER LEVEL ALARMS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2006
Resolved 3 November 2006
Engineering › Steering Gear System › Rudder Bearing
Issued 27 October 2006
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO UPPER RUDDER STOCK BEARING AND SEAL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2006
Resolved 3 November 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 27 October 2006
Resolved
PROVIDE WRITTEN CERTIFICATION STATING THE CURRENT VESSEL OWNER/OPERATOR NAME AND ADDRESS.
Action required: 705 - Other - as specified
Due 3 November 2006
Resolved 3 November 2006
Documentation › Certificates/Documents › FCC SSL
Issued 27 October 2006
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE WITH RADIO CALL SIGN ASSIGNNED TO CURRENT OWNER OR OPERATOR NAME AND ADDRESS.
Action required: 705 - Other - as specified
Due 31 December 2006
Resolved 15 January 2007
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 8 November 2005
Resolved
RENEW WATERLIGHT BATTERIES
Due 8 November 2005
Resolved 8 November 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 8 November 2005
Resolved
RENEW MAGNETIC COMPASS AND PROVIDE UPDATED DEVIATION TABLE AT PRIMARY STEERING STATION
Due 8 December 2005
Resolved 13 January 2006
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 8 November 2005
Resolved
PROVIDE HORN
Due 8 November 2005
Resolved 8 November 2005
Lifesaving › Hand Flares › Quantity
Issued 8 November 2005
Resolved
PROVIDE 3 ADDITIONAL DAY FLARES
Due 8 November 2005
Resolved 8 November 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 November 2005
Resolved
PROVIDE NEW FIRST AID KIT
Due 8 November 2005
Resolved 8 November 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 8 November 2005
Resolved
SERVICE FIRE EXTINGUISHERS
Due 8 November 2005
Resolved 8 November 2005
Engineering › Steering Gear System › Hydraulic Hose
Issued 8 November 2005
Resolved
REPAIR HYDRAULIC STEERING LEAKS FROM LOWE STEERING STATION
Due 8 December 2005
Resolved 13 January 2006
Lifesaving › Buoyant Apparatus › Serviceable
Issued 8 November 2005
Resolved
RENEW 2 Ea 15 MAN LIFEFLOATS OR PROVIDE TYPE 1 CAT 1 EPIRB
Due 8 November 2005
Resolved 8 November 2005
Resolution: EPIRB INSTALLED
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 November 2005
Resolved
PROVIDE 6 ADDITIONAL ADULT PFD'S
Due 8 November 2005
Resolved 8 November 2005
Navigation › Piloting/Steering › Marine Charts
Issued 16 November 2004
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE CURRENT MARINE CHARTS ON BOARD FOR UNITED STATES VIRGIN ISLANDS AND BRITISH VIRGIN ISLANDS. IN ADDITION, PROVIDE COPY OF 46 CFR, SUBCHAPTER "T".
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2004
Resolved 18 November 2004
Documentation › Certificates/Documents › FCC SSL
Issued 16 November 2004
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE VALID FCC SAFETY RADIO TELEPHONE CERTIFICATE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2004
Resolved 1 December 2004
Resolution: Received fax copy of corrected FCC Safety Radio Telephone Certificate.
Lifesaving › Hand Flares › Quantity
Issued 16 November 2004
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE THREE (03) ADDITIONAL VALID RED HAND FLARES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2004
Resolved 18 November 2004
Resolution: Received faxed receipt documenting purchase of replacement flares.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 November 2004
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE COMPLETE FIRST AID KIT AS PER 46 CFR 184.710.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2004
Resolved 18 November 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 November 2004
Resolved
PROVIDE ONE (01) COAST GUARD APPROVED CHILD SIZE LIFEJACKET.
Action required: 705 - Other - as specified
Due 16 November 2004
Resolved 18 November 2004
Resolution: Received faxed receipt documenting purchase of replacement jackets.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 November 2004
Resolved
PROVIDE FIVE (05) ADDITIONAL COAST GUARD APPROVED ADULT SIZE LIFEJACKETS.
Action required: 705 - Other - as specified
Due 16 November 2004
Resolved 18 November 2004
Resolution: Received faxed receipt documenting purchase of replacement jackets.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 October 2002
Resolved
REPAIR DECK RAIL STBD BOW LEGACY COMPONENT DESC: Deck Rail
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2002
Resolved 1 October 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 10 October 2002
Resolved
RE-ATTACH MANUAL ACTIVATION CABLE FOR FIXED GAS EXTINGUISHING SYSTEM LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2002
Resolved 1 October 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 18 October 2001
Resolved
PROVIDE MANUAL ACTIVATION CABLE AND AUTOMATIC ENGINE SHUTDOWN FOR FIXED FIRE EXTINGUISHING SYSTEM LEGACY COMPONENT DESC: Operating Controls
Due 18 November 2001
Resolved 15 November 2001
Lifesaving › Buoyant Apparatus
Issued 18 October 2001
Resolved
REPAIR RIPS AND TEARS ON ALL LIFEFLOATS
Due 18 November 2001
Resolved 10 October 2002
Engineering
Issued 25 October 2000
Resolved
Provide repair proposal for fuel tank which addresses separation of FRP layers on top of tank.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Fire Fighting
Issued 3 December 1999
Resolved
Service fire extinguishers.
Condition: Unknown
Due 14 January 2000
Resolved 31 March 2000
Lifesaving
Issued 3 December 1999
Resolved
Conduct satisfactory man-overboard drill.
Condition: Unknown
Due 3 December 1999
Resolved 3 December 1999
Documentation
Issued 3 December 1999
Resolved
Renew FCC Safety Certificate.
Condition: Unknown
Due 3 December 1999
Resolved 3 December 1999
Construction/Loadline
Issued 3 December 1999
Resolved
Install high level bilge alarm systems throughout the vessel per regulations.
Condition: Unknown
Due 14 January 2000
Resolved 31 March 2000
Lifesaving
Issued 2 December 1996
Resolved
COMPLETE IFR WORKLIST ISSUED 02DEC96 PRIOR TO 20JAN97.
Condition: Unknown
Due 20 January 1997
Resolved 18 February 1997
Lifesaving
Issued 2 December 1996
Resolved
REPLACE RING BUOY INOPERATIVE WATERLIGHT BATTERY.
Condition: Unknown
Due 4 January 1997
Resolved 18 February 1997
Lifesaving
Issued 2 December 1996
Resolved
REPLACE TWO INOPERATIVE LIFE FLOATS WATERLIGHTS BATTERIES.
Condition: Unknown
Due 3 January 1997
Resolved 18 February 1997
Lifesaving
Issued 10 June 1996
Resolved
NO LATER THAN 11 MARCH 1997, INSTALL ON BOARD IN A FLOAT FREE ARRANGEMENT, A FCC ACCEPTED CATEGORY 1, 406 MHz EPIRB.
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Lifesaving
Issued 5 December 1995
Resolved
Secure lifefloats to weaklink prior to taking passngers for hire._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 December 1995
Resolved 6 December 1995
Lifesaving
Issued 5 December 1995
Resolved
Provide 3 red flares. 3 flares aboard are expired by 1 month.
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Construction/Loadline
Issued 5 December 1995
Resolved
Make temporary repairs to hull above the waterline. Small nicks of FRP removed during Hurricane Marilyn. Repairs to be made permanent at next drydock examination NLT 31JUL96._x001C_ _x001C_
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Construction/Loadline
Issued 2 December 1993
Resolved
PROVIDE CAPTIVE CHAIN FOR LAZARETTE HATCH COVER.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Documentation
Issued 2 December 1993
Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Fire Fighting
Issued 2 December 1993
Resolved
PROPERLY MOUNT PORTABLE EXTINGUISHER IN FORWARD COMPARTMENT.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Fire Fighting
Issued 2 December 1993
Resolved
PROVIDE PROOF OF SERVICING FOR ALL PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Documentation
Issued 4 December 1992
Resolved
Provide valid Radiotelephony Certificate from the FCC.
Condition: Unknown
Due 2 September 1993
Resolved 2 September 1993
Lifesaving
Issued 4 December 1992
Resolved
Mark all lifefloats and lifefloat paddles with vessel's name.
Condition: Unknown
Due 2 September 1993
Resolved 2 September 1993
Lifesaving
Issued 4 December 1992
Resolved
Properly rig the three lifefloats located on the bridge level in accrodancewith 46 C.F.R. Parts 180.15 & 180.20. Either provide each lifefloat with its own painter and weak link; OR secure all three lifefloats together to asingle painter and weak link. Provide each lifefloat with a water light.
Condition: Unknown
Due 2 September 1993
Resolved 2 September 1993
Navigation
Issued 4 December 1992
Resolved
Hydrostatically test the air tank located on the bridge which provides compressed air for the air horn in accordance with requirements for DOT approved SCUBA tanks.
Condition: Unknown
Due 2 September 1993
Resolved 2 September 1993
Fire Fighting
Issued 4 December 1992
Resolved
Provide one additional B-II portable fire extinguisher for the passenger accommodations area.
Condition: Unknown
Due 11 December 1992
Resolved 2 September 1993
Lifesaving
Issued 4 December 1992
Resolved
Provide pendants on all lifefloats as required by 46 C.F.R. Part _x001C_ 160.010-3(g).
Condition: Unknown
Due 2 September 1993
Resolved 2 September 1993
Electrical
Issued 4 December 1992
Resolved
Properly dead end unused wires under bridge console.
Condition: Unknown
Due 2 September 1993
Resolved 2 September 1993
Documentation
Issued 4 December 1990
Resolved
PERFORM A SIMPLIFIED STABILITY TEST UNDER THE SUPERVISION OF A QUALIFIED COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Engineering
Issued 26 October 1990
Resolved
PROVIDE VENTILATION DUCT THAT DRAWS FROM LOWEST POINT IN ENGINE ROOM BILGE AS REQUIRED BY 46 CFR 182.20-45.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Engineering
Issued 26 October 1990
Resolved
PROVIDE FLASH SHIELD AND PLUG COCK FOR RAYCOR FILTER MOUNTED ON AFT BULK- HEAD IN ENGINE ROOM.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Lifesaving
Issued 27 December 1989
Resolved
PAINT RING BUOY ORANGE IN ACCORDANCE WITH 46 CFR 180.30-5(D)
Condition: Unknown
Due 27 December 1989
Resolved 27 December 1989
Documentation
Issued 27 December 1989
Resolved
PROVIDE VALID FCC EXEMPTION CERTIFICATE FOR SSB RADIO
Condition: Unknown
Due 27 December 1989
Resolved 27 December 1989
Engineering
Issued 27 December 1989
Resolved
INSTALL GUARD FOR BELT DRIVEN COMPRESSOR ON MAIN ENGINE IN ACCORDANCE WITH GOOD MARINE PRACTICE
Condition: Unknown
Due 27 December 1989
Resolved 27 December 1989
Documentation
Issued 23 November 1987
Resolved
VESSEL IS TO PROVIDE THIS OFFICE WITH A COPY OF FCC RADIO SAFETY CERTIFICATE PRIOR TO 06JUN88.
Condition: Unknown
Due 23 November 1987
Resolved 23 November 1987
Construction/Loadline
Issued 10 July 1986
Resolved
PLACE A SUITABLE DRIVE BELT ON THE MAIN ENGINE DRIVEN BILGE PUMP AND TEST IT FOR PROPER OPERATION PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Engineering
Issued 10 July 1986
Resolved
PRPERLY VENT THE DIESEL FUEL TANK IN ACCORDANCE WITH 46 CFR 182.20-35.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Accommodation/Occupational Safety
Issued 10 July 1986
Resolved
INSTALL A SUITABLE TYPE II OR TYPE III MARINE SANITATION DEVICE AS REQUIREDBY 33 CFR 159.7 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Lifesaving
Issued 10 July 1986
Resolved
PLACE A SUITABLE PAINTER AND A FLOAT FREE LINK ON THE VESSELS LIFE FLOAT INACCORDANCE WITH 46 CFR 180.15 AND 46 CFR 180.20.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Navigation
Issued 10 July 1986
Resolved
RENEW THE HYDRAULIC RESERVOIR TANK FOR THE HAND HYDRAULIC STEERING SYSTEM.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986