NOBLE JOHNNIE HOFFMAN

NOBLE JOHNNIE HOFFMAN is a 1976 mobile offshore drilling unit. The Coast Guard has recorded 110 inspections since 1982, most recently in June 2005, along with 344 deficiencies.

Records from 1982 to 2005. Most recent: inspection, 9 June 2005.

Built
1976
Last inspected
9 June 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8756239 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WRW 2663
Flag
UNITED STATES
—
Maury page id
psix-51372

Inspections, by type

…with no type recorded41
Years with a record 24 calendar years (1982–2005)
The 110 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1865 - Regulatory (Subpart C or D), Net Ton
6218 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CHASITY BROOKE Commercial Fishing Vessel · MISLE 802 · 13 November 2001 · activity 1482955TARA CROSBY Towing Vessel · MISLE 116441 · 25 October 1992 · activity 66431CROSBY TARPON Towing Vessel · MISLE 141665 · 25 October 1992 · activity 66431ELIZABETH ANN Towing Vessel · MISLE 211711 · 25 October 1992 · activity 66431

Inspection history · 110

9 June 2005 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2548661
23 March 2005 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2337599
1 June 2004 Examination of Repairs · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2078011
2 September 2003 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1894422
11 July 2003 Periodic Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1853796
21 January 2003 Drydock Extension · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1733188
30 December 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1724253
3 December 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1713765
22 October 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1694456
9 July 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1646362
2 July 2002 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1640018
28 May 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1626122
15 May 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1616944
19 April 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1627237
22 March 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1495875
13 November 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1482955
23 August 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 6757
7 May 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1379426
27 February 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1058912
24 July 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1051405
14 June 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1053261
23 May 2000 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 818551
19 April 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446916
29 March 2000 Deficiency Check · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1433623
8 September 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 125055
12 July 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1094095
30 June 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1083651
3 June 1999 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1397186
17 February 1999 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1129426
27 July 1998 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 795020
23 April 1998 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1433335
27 January 1998 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1469164
4 September 1997 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1121515
19 May 1997 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1407891
13 December 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1093228
28 June 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1089269
2 May 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1360501
27 March 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1078146
24 January 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 880419
12 June 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1186359
30 May 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1182375
25 April 1995 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1078795
4 April 1995 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1436984
28 March 1995 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1439600
10 February 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 156680
27 January 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 178852
17 January 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 834522
9 January 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 26717
9 December 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1143887
12 August 1994 Damage Survey · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1173429
4 May 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171629
22 April 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 109018
7 April 1994 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1399947
26 February 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 66656
16 September 1993 Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1148153
8 September 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1141082
7 September 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1154451
10 August 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1157389
3 June 1993 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1382596
1 May 1993 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1449628
9 November 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1132590
25 October 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 66431
29 May 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1265009
4 May 1992 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1260759
7 June 1991 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 929688
7 June 1991 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1241157
9 May 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238248
25 April 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 930297
3 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228459
1 February 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1244290
8 November 1990 Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913649
11 July 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211874
13 June 1990 Deficiency Check · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920917
17 May 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 900339
17 May 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918411
17 May 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228933
24 July 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 886823
5 May 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1038737
20 March 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1340351
20 December 1988 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1039734
22 May 1988 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1203171
5 November 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1330535
5 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315554
14 November 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329593
13 August 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004607
16 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304112
1 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296188
28 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298420
4 April 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293840
16 September 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299315
4 September 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988915
24 July 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1290558
19 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 980256
18 December 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 977087
14 September 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286799
23 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281257
6 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1284986
31 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1276308
13 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968480
29 August 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1276719
10 August 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969369
29 June 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963482
12 May 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272481
11 April 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968256
26 October 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965427
12 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277416
27 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969484
6 July 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973741
6 April 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966922
6 April 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279249

Deficiency record · 344

Lifesaving › Lifeboat › Capacity
Issued 23 March 2005 Resolved
Prove proper load test of 36 man lifeboat at station #4.
Due 7 April 2005
Resolved 29 March 2005
Construction/Loadline › Hull › Keel
Issued 23 March 2005 Resolved
Conduct SEILOD Phase 2 at next rig move. Resolution date is when rig is scheduled to move next.
Due 31 July 2005
Resolved 8 June 2005
Resolution: Vessel is now Liberian Flagged. We no longer inspect hull exams on this MODU. If they want to switch flag back to US, we will require a hull exam.
Construction/Loadline
Issued 27 August 2003 Resolved
see inspection notes for details.
Due 30 September 2003
Resolved 3 June 2004
Construction/Loadline
Issued 27 August 2003 Resolved
see inspection notes for details.
Due 30 September 2003
Resolved 3 June 2004
Operations/Management › Drills/Instruction
Issued 11 July 2003 Resolved
Update station bill to reflect only those persons holding credentials for lifeboatmen are listed as "In Charge" or assistant "In Charge" of lifeboat capsules and lifeboats.
Due 11 August 2003
Resolved 27 August 2003
Operations/Management › Drills/Instruction
Issued 11 July 2003 Resolved
Each abandonment drill must include the lowering of at least 1 lifeboat and the same must be logged at each drill.
Due 11 August 2003
Resolved 27 August 2003
Operations/Management › Drills/Instruction
Issued 11 July 2003 Resolved
Each lifeboat must be launched quarterly, sprinklers tested and the same logged.
Due 11 August 2003
Resolved 26 August 2003
Documentation › Certificates/Documents
Issued 11 July 2003 Resolved
Loadline Certificate issued 25Jun03 by ABS Del Carmen must be reissued to reflect most recent stability letter issued 15NOV02 and incorporated in Rev. 4 of the operations manual.
Due 11 August 2003
Resolved 26 August 2003
Operations/Management › Drills/Instruction
Issued 11 July 2003 Resolved
Required weekly & monthly test of emergency generator as well as quarterly line throwing device drills must be recorded in a log and retained for CG review.
Due 11 August 2003
Resolved 26 August 2003
Deck/Cargo
Issued 11 July 2003 Resolved
Provide proof of annual crane exam IAW API RP 2D for both port & stbd cranes. Current exam expired 21May03. Cranes are overdue.
Due 11 August 2003
Resolved 26 August 2003
Electrical › Electric Generation Source (service)
Issued 11 July 2003 Resolved
Prove proper operation of reverse power relays for all 3 generators.
Due 11 August 2003
Resolved 26 August 2003
Accommodation/Occupational Safety › Ventilation
Issued 11 July 2003 Resolved
Prove proper operation of control room office remote ventilation shutdown.
Due 11 August 2003
Resolved 26 August 2003
Lifesaving › Lifeboat Equipment
Issued 11 July 2003 Resolved
Provide required provisions for #2 lifeboat.
Due 11 August 2003
Resolved 26 August 2003
Lifesaving › Launching Appliances
Issued 11 July 2003 Resolved
Lubricate falls on davit servicing #1 and #3 liferafts.
Due 11 August 2003
Resolved 26 August 2003
Lifesaving › Lifebuoys
Issued 11 July 2003 Resolved
Prove all lifebuoys outfitted, stenciled and stowed in accordance with 46 CFR 108.580 and 108.515(1) and (2).
Due 11 August 2003
Resolved 26 August 2003
Lifesaving › Line-Throwing Appliances
Issued 11 July 2003 Resolved
Provide line throwing appliance for international service IAW 46 CFR 160.040.
Due 11 August 2003
Resolved 26 August 2003
Electrical › Electrical Distribution System (service)
Issued 11 July 2003 Resolved
Prove gas tightness of all mud pit room bulkhead penetrations. Several are currently open.
Due 11 August 2003
Resolved 26 August 2003
Electrical
Issued 11 July 2003 Resolved
Prove proper operation of derrick camera video monitor's purge alarm.
Due 11 August 2003
Resolved 26 August 2003
Lifesaving › Lifeboat
Issued 11 July 2003 Resolved
Prove proper operation of waterspray system on #2 lifeboat.
Due 11 August 2003
Resolved 26 August 2003
Lifesaving › Launching Appliances
Issued 11 July 2003 Resolved
Adjust limit switches on #2 and #3 lifeboats. Switches must cut out 6" to 12" from stops.
Due 11 August 2003
Resolved 26 August 2003
Lifesaving › Lifejacket/PFD (General)
Issued 11 July 2003 Resolved
Provide all lifejackets with lights suitable for international service IAW 46 CFR 108.580 and 161.112.
Due 11 August 2003
Resolved 26 August 2003
Deck/Cargo
Issued 11 July 2003 Resolved
Prove secure fastening of helo deck perimeter fencing.
Due 11 August 2003
Resolved 26 August 2003
Lifesaving › Lifeboat
Issued 11 July 2003 Resolved
Provide statement attesting to the proper operation of the #1 Lifeboat steering system. Boat must be operated in the water and steering tested while making way. This statement must be delivered to the attending inspector prior to his departure.
Due 13 July 2003
Resolved 12 July 2003
Construction/Loadline › Hull
Issued 24 January 2003 Resolved
All above repairs shall be accepted to the satisfaction of the attending inspector prior to entering water.
Due 27 July 2003
Resolved 23 October 2003
Construction/Loadline
Issued 23 January 2003 Resolved
Crop & renew remaining horizontal angles on skin at leg well in tank 35.
Due 31 October 2003
Resolved 30 October 2003
Operations/Management
Issued 21 January 2003 Resolved
Rig is not to be lowered into the water until all areas of sideshell, and bottom which is eithered holed or wasted beyond 20% of original required scantling is cropped & renewed in accordance with applicable ABS rules and Coast Guard requirements.
Due 27 July 2003
Resolved 23 October 2003
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 21 January 2003 Resolved
Provide Coast Guard approved plans for portable quarters unit serial #1032055. Building is not to have any habitation until CG approved plans are confirmed by the attending CG Marine Inspector.
Due 20 April 2003
Resolved 9 April 2003
Construction/Loadline
Issued 21 January 2003 Resolved
Crop & renew remaining horizontal angles on stern shell in tank 26.
Due 31 October 2003
Resolved 30 October 2003
Construction/Loadline
Issued 21 January 2003 Resolved
Provide proof of valid load line certificate or remove rig from service at 0000 01NOV03 in accordance with CG Eight District letter 16711/DDE dated September 5, 2003.
Due 1 November 2003
Resolved 30 October 2003
Construction/Loadline
Issued 21 January 2003 Resolved
Complete crop & renew of all wasted remaining steel members throughout unit in accordance with ABS concurrence and acceptance of '93 study and '88 plans if they can be produced and accepted by ABS hull technical division.
Due 30 April 2004
Resolved 3 June 2004
Electrical › Electric Generation Source (emergency)
Issued 28 May 2002 Resolved
Standby generator; a) Repair exhaust leaks, y-flange, between turbocharges and exhaust pipe. b) Re configure flexible fuel return lines, not to exceed 30inch max length. c) Repair leaks on supply and return fuel fitting on fuel filter.
Due 28 June 2002
Resolved 28 May 2002
Construction/Loadline
Issued 19 April 2000 Resolved
CROP AND RENEW WASTED SECTIONS OF OVERHEAD STIFFENERS IN MUD PITS AS NECESSARY.
Condition: Unknown
Due 19 April 2000
Resolved 19 April 2000
Electrical
Issued 19 April 2000 Resolved
CONDUCT AND LOG SATISFACTORY TEST OF RIG'S TOTAL RIG EMERGENCY SHUT-DOWN FROM ALL LOCATIONS AND SEMI-ANNUAL LOAD TEST OF EMERGENCY BATTERIES.
Condition: Unknown
Due 19 April 2000
Resolved 19 April 2000
Electrical
Issued 19 April 2000 Resolved
ENSURE ALL ELECTRICAL FIXTURES AT MUD LAB LOCATION MEETS CLASS 1 DIVISION 2REQUIREMENTS.
Condition: Unknown
Due 19 April 2000
Resolved 19 April 2000
Engineering
Issued 3 June 1999 Resolved
CONTINUE TO REPLACE ALL INADEQUATE FLAME SCREENS THROUGHOUT RIG.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Construction/Loadline
Issued 3 June 1999 Resolved
RENEW COVER FOR MAIN DECK OPENING OVER MUD PIT ROOM AND REPAIR HOLE IN WELDFOR OPENING.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Lifesaving
Issued 3 June 1999 Resolved
CONDUCT AND PROVIDE DOCUMENTATION FOR RELEASE GEAR TEST ON BOTH PORT AND STBD LIFEBOATS
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Fire Fighting
Issued 2 May 1996 Resolved
PROVE PROPER OPERATION OF MOTOR ROOM HALON ENGINE AND VENTILATION SHUTDOWNSAND PROPER OPERATION OF THE ASSOCIATED FIRE DAMPERS.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Construction/Loadline
Issued 2 May 1996 Resolved
CROP AND RENEW ALL WASTED OVERHEAD STIFFENERS IN MUDPIT ROOM.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Fire Fighting
Issued 2 May 1996 Resolved
HYDRO TEST OUT OF DATE BREATHING AIR CYLINDER IN PORTSIDE FIREFIGHTING LOCKER.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Accommodation/Occupational Safety
Issued 2 May 1996 Resolved
REPAIR FAULTY AUTOMATIC CLOSING DEVICE FOR PORTSIDE MUDPIT ROOM DOOR.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Electrical
Issued 2 May 1996 Resolved
CORRECT POSITIVE PRESSURE PROBLEM ASSOCIATED WITH MUDPIT ROOM VENTILATION SYSTEM. PROVE PROPER OPERATION OF THE SAME.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Electrical
Issued 2 May 1996 Resolved
REPAIR/REPLACE EXPLOSION PROOF JUNCTION BOX FOR GAITRONICS PHONE LOCATED UNDERNEATH SHAKER HOUSE.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Lifesaving
Issued 2 May 1996 Resolved
LABEL FADED SIGN FOR TOTAL RIG SHUTDOWN LOCATED ON DRILL FLOOR.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Unknown
Issued 2 May 1996 Resolved
HYDRO TEST OR GAUGE AIR RECEIVER UNDERNEATH DRILL FLOOR. SEND RESULTS TO MSO PORT ARTHUR, TEXAS.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Electrical
Issued 2 May 1996 Resolved
PROVE PROPER OPERATION OF AIR CONDITION VENTILATION SHUTDOWN IN OIM'S OFFICE.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Electrical
Issued 2 May 1996 Resolved
PROVE PROPER OPERATION FOR LOSS OF PURGE ALARM TO HIGH VOLTAGE CABINET ON AFT SIDE OF DRILL FLOOR FOR TOP DRIVE UNIT.
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Construction/Loadline
Issued 12 June 1995 Resolved
CRACKS REVEALED DURING LAST PHASE II EXAM TO SPUD CANS CONNECTIONS, TO BE REEXAMINED UPON REMOVAL FROM THE CURRENT SITE IN THE PRESENCES OF ABS/CG AND RESULTS TO BE SUBMITTED TO PATMS. ABS FAX DTD 31MAY95 IN PATMS FILE.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Construction/Loadline
Issued 30 May 1995 Resolved
CRACKS REVEALED DURING LAST PHASE II EXAM TO SPUD CAN CONNECTIONS. TO BE REPAIRED AS PER ABS REPORT ON FILE AT PATMS PRIOR TO ABS CREDITING UWILD AND FURTHER OPERATION OF UNIT.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Electrical
Issued 4 April 1995 Resolved
Prove proper operation of main generator reverse power relays.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Construction/Loadline
Issued 4 April 1995 Resolved
Renew flame screens and covers on following tank vents: 35P, 38S, 40S, 31P.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Construction/Loadline
Issued 28 March 1995 Resolved
COMPLETE PHASE II OF SEILOD EXAM. INSPECTION OF LEG TO CAN CRITICAL CONNECTIONS REMAIN. THIS ITEM TO BE COMPLETED PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Accommodation/Occupational Safety
Issued 12 August 1994 Resolved
CONDUCT HYDROSTATIC TEST ON AIR RECEIVER BELOW DRILL FLOOR TO 1.5 TIMES DESIRED WORKING PRESSURE.
Condition: Unknown
Due 8 September 1994
Resolved 8 September 1994
Construction/Loadline
Issued 12 August 1994 Resolved
CRACKS REVEALED DURING LAST HULL EXAM WERE EXAMINED-NO PROPAGATION. TO BE CLOSELY EXAMINED NEXT HULL EXAM. REPORT ON FILE MORMS.
Condition: Unknown
Due 12 August 1994
Resolved 12 August 1994
Accommodation/Occupational Safety
Issued 4 May 1994 Resolved
OPEN AND MAKE READY FOR INSPECTION VSL'S AIR RECEIVER AND DRY BULK TANKS. DRY BULK TANKS WILL REQUIRE A MARINE CHEMISTS CERT PRIOR TO ENTRY.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Documentation
Issued 4 May 1994 Resolved
SUBMIT REVISED OPS MANUAL FOR APPROVAL TO MARINE SAFETY CENTER. OPS MANUALSHOULD INCLUDE REVISION THREE. WHEN APPROVED OPS MANUAL IS RECEIVED SUBMITTO [name withheld], AL FOR APPROVAL IN OPERATIONAL ZONE.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Construction/Loadline
Issued 16 September 1993 Resolved
Proceed to Sabine Pass, TX, obtain approval of proposed repairs, and make permanent repairs to wastage noted in Preload & Preload Ballast tanks.
Condition: Unknown
Due 16 September 1993
Resolved 16 September 1993
Construction/Loadline
Issued 10 August 1993 Resolved
PROVIDE REPAIR PROPOSAL REGARDING UPPER HULL TANK BULKHEADS/FRAMES TO [name withheld]. REFERENCE CASE NO. MI93023740.
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Engineering
Issued 3 June 1993 Resolved
TEST POP OFFS FOR BOTH MAIN MACHINERY SPACE AND RIG FLOOR AIR RECEIVERS.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Lifesaving
Issued 3 June 1993 Resolved
PROVIDE DOCUMENTATION SHOWING MANUFACTURES APPROVED REPAIR PROCEDURES FOR #1 CAPSULE WERE COMPLETED AS REQUIRED UNDER REQUIREMENT #8.
Condition: Unknown
Due 6 July 1993
Resolved 6 July 1993
Lifesaving
Issued 3 June 1993 Resolved
MAKE MANUFACTURERS APPROVED PERMANENT REPAIRS TO CRACK IN OVERHEAD OF #1 CAPSULE STARBOARD SIDE IN CONTACT WITH DAVIT STABILIZING STANCHION. UPON COMPLETION OF REPAIRS PROVIDE COPY OF SERVICE REPORT AND REPAIRS MADE TO MARINE SAFETY OFFICE PORT ARTHUR, TEXAS.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Electrical
Issued 3 June 1993 Resolved
PLUG 4 BULKHEAD WIRE PENETRATIONS BETWEEN MUDPIT AND MUD PUMP ROOM PORTSIDENEAR DOOR.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Electrical
Issued 3 June 1993 Resolved
REPLACE BATTERIES IN EMERGENCY BATTLE LANTERNS AS NECESSARY.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Electrical
Issued 3 June 1993 Resolved
RENEW PLASTIC "HIGH VOLTAGE" BOX IN SACK ROOM BY FORKLIFT REFUELING STATION.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Engineering
Issued 3 June 1993 Resolved
OPEN FOR INTERNAL INSPECTION #3 CEMENT AND #1 & #3 BARITE BULK TANKS NLT NEXT HULL EXAM
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Fire Fighting
Issued 3 June 1993 Resolved
REPLACE HANDLE FOR FIRESTATION NUMBER 46.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Lifesaving
Issued 3 June 1993 Resolved
IF CAPSULE #1 IS REQUIRED TO BE MOVED OFF FACILITY FOR REPAIR PROVIDE REPLACEMENT CAPSULE.
Condition: Unknown
Due 3 June 1993
Resolved 3 June 1993
Fire Fighting
Issued 3 June 1993 Resolved
RENEW LOW VELOCITY FOG APPLICATOR HEAD ON APPLICATOR IN GENERATOR ROOM - CAN NOT BE PINE CONE TYPE.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Construction/Loadline
Issued 1 May 1993 Resolved
UNDER WATER SURVEY REPORT AND ABS SURVEY REPORT DATED 13JUL93 REVEALED A TOTAL OF 4 INDICATIONS ON THE LEG TO CAN CONNECTIONS. PORT AND STBD LEGS WERE INVOLVED. AREAS WERE MARKED AND DOCUMENTATED. THESE AREAS AS PER ABS RECOMMODATIONS MUST BE RE-EXAMINED NLT 31JUL94. PATMS HAS FIELD REPORT.
Condition: Unknown
Due 1 May 1993
Resolved 1 May 1993
Lifesaving
Issued 4 May 1992 Resolved
PROVIDE BULB FOR LEL METER
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Lifesaving
Issued 4 May 1992 Resolved
TEST GENERAL ALARM BELLS
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Lifesaving
Issued 4 May 1992 Resolved
RESERVICE AND PROVE OPERABLE O2 METER
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Electrical
Issued 4 May 1992 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL TRIPS ON ALL FOUR DIESEL GENERATORS
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Fire Fighting
Issued 4 May 1992 Resolved
PROVE PROPER OPERATION OF HALON ACTUATED DIESEL ENGINE SHUTDOWN
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Accommodation/Occupational Safety
Issued 4 May 1992 Resolved
PROVIDE MANUFACTURER'S DATA REPORT FOR LOW PRESSURE AIR RECEIVER IN GENERATOR RM (SER NO.200827)
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Deck/Cargo
Issued 4 May 1992 Resolved
CLEAN OUT AND MAKE ALL P-TANKS READY FOR INTERNAL INSPECTION DURING NEXT HULL INSPECTION
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Electrical
Issued 4 May 1992 Resolved
LABEL REMOTE FUEL OIL SHUTOFF VALVE CONTROL FOR EMD DIESELS
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Lifesaving
Issued 4 May 1992 Resolved
CONDUCT FIRE AND BOAT DRILL
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Fire Fighting
Issued 4 May 1992 Resolved
PROVIDE UP TO DATE HYDROSTATIC TESTS FOR BOTH PORTABLE FIRE EXTINGUISHERS ON L/B NO. 1.
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Construction/Loadline
Issued 8 November 1990 Resolved
REPAIR / REPLACE PINION / BALL GEAR TO NUMBER FOUR (4) (FROM BOTTOM) HYDRAULIC JACKING UNIT OF B CHORD ON PORT LEG.
Condition: Unknown
Due 8 November 1990
Resolved 8 November 1990
Construction/Loadline
Issued 8 November 1990 Resolved
SUBMIT REPAIR PROPOSAL TO THE ABOVE OFFICE AND MAKE PERMANENT REPAIRS TO WASTED / FRACTURED LONG TRANSVERSE BULKHEADS AND OTHER MEMBERS IN P.L. TANKNUMBER 35 (NOTE: CREDIT FOR HULL EXAM WILL NOT BE GRANTED UNTIL THIS RE- QUIREMENT HAS BEEN COMPLETED.)
Condition: Unknown
Due 8 November 1990
Resolved 8 November 1990
Electrical
Issued 13 June 1990 Resolved
PROVIDE NEGATIVE PRESSURE FOR MUD PITS.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Construction/Loadline
Issued 13 June 1990 Resolved
PROVIDE TO [name withheld] PROPOSAL FOR WASTED AND FRACTURED BULK- HEADS TRANSVERSE, LONGITUDINAL, AND OTHER WASTED MEMBERS LONGITUDINAL FRAMES, BRACKETS TO #35 PRELOAD TANK. PROVIDE EXTENSIVE REPORT OF GAUGINGS TO ENTIRE AREA.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Electrical
Issued 13 June 1990 Resolved
REMOVE GROUND TO EMERGENCY SWITCH BOARD A0.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Navigation
Issued 13 June 1990 Resolved
PROVIDE ON BOARD AN ADDITIONAL O2 METER AS PER 46 CFR 108.497.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Electrical
Issued 13 June 1990 Resolved
PROVIDE EXPLOSION PROOF HORN WITH SEALED FITTING TO GAS DETECTOR STBD SIDE RIG FLOOR.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Electrical
Issued 13 June 1990 Resolved
PROVIDE EXPLOSION PROOF ENCLOSURE FOR EX LOG TOOL FACE INDICATOR OR PURGE IN ACCORDANCE WITH NFPA-496.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Electrical
Issued 13 June 1990 Resolved
PROVIDE EXPLOSION PROOF WARNING HORN FOR GAS DETECTOR UNIT (TOTCO) BY DRILLER'S CONSOLE.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Electrical
Issued 13 June 1990 Resolved
PROVIDE EXPLOSION PROOF DRIVER FOR P A SYSTEM SPEAKER UPPER SHAKER AREA.
Condition: Unknown
Due 13 June 1990
Resolved 13 June 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
REPAIR OR REPLACE LEAKING DRAIN VALVE ON RIG FLOOR AIR RECEIVER.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Unknown
Issued 17 May 1990 Resolved
PROVIDE PROPER OPERATION OF OBSTRUCTION LIGHTS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PORPERLY SUPPORT OVERHEAD RUN OF WIRING ABOVE CATWALK AND STORAGE AREA PORTSIDE ENGIN ROOM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990 Resolved
REPAIR LOSS OF FUNCTION FLASHING BEACON # 1 EMD.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
REPLACE ALL THREE RUNS OF HOT WATER PIPING FROM WATER HEATER TO GOOD METAL NUMEROUS POUBLERS AND WELDED FRACTURIS ARE PRESENT LOCATED IN ENGIN ROOM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE SUITABLE JUCTION BOX FOR TAPED SPLICED CONNECTION BENEATH RIG FLOOR STBD SIDE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REMOUNT JUCTION BOX AND PROPERLY SUPPORT ALL LOOSE WIRING IN VICINITY OF CANTILEUER SKID STBD SIDE BENEATH RIG FLOOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
PROPERLY MARK GENERAL ALARM CONTACT MAKER STBD SIDE RIG FLOOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Deck/Cargo
Issued 17 May 1990 Resolved
RE-MOUNT PROPERLY MARK, GAS DETECTOR HORN RIG FLOOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE EXPLOSION PROOF SWITCH BOX FOR TOTCO RECORDER SELECTOR BOX RIG FLOOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDEVISUAL OR AUDIBLE A LOSS OF PURGE ALARM FOR TOTCO VISUAL LOGGER IN ACCORDANCE WITH NFPA -496.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROPERLY MOUNT EXPLOSION PROOF JUCTION BOX STBD AFT RIG FLOOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROPERLY MOUNT ALL EXPLOSOIN PROOF JUCTION BOXES ON WIREWAY OVERHEAD RIG FLOOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROPERLY SUPPORT WIRE RUN STBD OUT BOARD JACKING TOWER EXTERIOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Construction/Loadline
Issued 17 May 1990 Resolved
PROVIDE NAME ON VESSEL 4" LETTERS PORT AND STBD BOW AND STERN WITH HAILING PORT.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Construction/Loadline
Issued 17 May 1990 Resolved
PROVIDE DRAFT MARKS ON VESSEL 1FT INCREMENTS BOTH SIDES OF BOW AND STERN EXTERIOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990 Resolved
CLEAN-UP HEAVY ACCUMULATIONS OF OIL AND DEBRIS (OIL/FUEL FILTERS, RAGS ECT)BENEATH #1,#2 AND #3 EMDS AND CATWALKS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990 Resolved
REPLACE BROKEN "SQUARL D" HMIT SWITCH LOCATED NEXT TO GOWNOR #2 EMD.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990 Resolved
REPAIR HEAVY OIL LEAK #2 EMD.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990 Resolved
PROVIDE FLAME SHIELDS FOR RACOR FILTERS ON EMDS. REMOVE PET COCK DRAINS ANDPLUGS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE BLANKS FOR OPENING IN ELECTRICAL PANEL #2 PORT FORWARD ENGINROOM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REFASTEN MOUNTINT FRAME FOR SWITCH BOXES (#1 #2 PORTABLE WATER PRESSURE SET) STBD SIDE ENGIN ROOM AFT OF AIR RECEIVERS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
REMOVE HEAVY ACCUMULATION OF HYDRAULIC FLUID BENEATH QUINCY COMPRESSORS IN ENGIN ROOM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Unknown
Issued 17 May 1990 Resolved
REPAIR OR REPLACE ALL EXTINGUISED LIGHTS ON HELOCOPTER DECK.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Unknown
Issued 17 May 1990 Resolved
MARK MECHANICAL DISENGAGING APPARATUS CONTROL LEVER IN #1 AND #2 LIFE BOATSAS REQUIREMENTS BY 46 CFR 108. 645 (B). [APPEAL>
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROPERLY SUPPORT WIRING IN OVERHEAD ABOVE RIG FLOOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROPERLY MOUNT EXPLOSION PROOF SWITCH BOX BEHIND STBD DRAWWORKS MOTOR ON AFT BULKHEADOF RIG FLOOR (BOX IS MOUNTED TO ANOTHER BOX WITH AN EXPLOSION PROOF UNION ONLY).
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROPERLY MARK AND IDENTIFY EXPLOSION PROOF SWITCH BOX (BEHIND GLASS) ON AFT BULKHEAD OF RIG FLOOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Unknown
Issued 17 May 1990 Resolved
PROVIDE SEALED FITTINGS ON LIGHTS IN VICINITY OF MUD CIRCULATING PUMPS (CLASS I DIVISION I AREA).
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE BLANK IN MAIN SWITCH BOARD, EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REPAIR EXHAUST LEAKS IN MAIN FLANGE TO RISER CONNECTIONS AND BOTH TERBO- CHARGER TO RISER CONNECTIONS FOR EMERGENCEY GENERATOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
MARK PROPERLY GEN. ALARM BELL IN EMERG. GEN. SPACE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
VENT #22 REPLACE WASTED COVER TO BALL CHECK.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Deck/Cargo
Issued 17 May 1990 Resolved
MOUNT ALL GAS SENSORS IN SHAKER AREA.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE PACKING FOR GLAND NUTS LOCATED ON STBD HYDRUALIC JACKING SYSTEM D.C. VOLTAGE PANEL.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE SEALED FITTING FOR CLASS I DIVISION I AREA, TIGHTEN EXPLOSION PROOF UNION, REPLACE MISSING BOLT FOR EXPLOSION PROOF JUNCTION BOX LIGHT PANEL BENEATH SHALE SHAKER.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REMOVE DEAD END WIRING IN COMPANIONWAY BENEATH SHAKER.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REPLACE WITH CLASS I DIVISION I FITTING (CLASS I DIV. II PRESENTLY INSTALL-ED) CONNECTION ON JUNCTION BOX CONNECTED TO LIGHT IN COMPANIONWAY BENEATH SHAKER AREA. PROPERLY SUPPORT WIRE TO LIGHT.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROPERLY SUPPORT ALL OVERHEAD WIRING IN SHAKER AREAS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE PROPER SEALED FITTING FOR UPPER SHAKER LIGHTS (CLASS I DIVISION I AREA.)
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REPLACE WIRING WITH BROKEN OUTER CONDUCTOR TO DRIVE MOTOR FOR UPPER FORWARD SHAKER.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REPLACE MISSING BOLT ON EXPLOSION PROOF CONDUIT RUN ACCESS PLATE, TO UPPER FORWARD SHALE SHAKER EXPLOSION PROOF SWITCH BOX.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE MOTORS (OR PROVE SUITABILITY BY DOCUMENTATION ) FOR ALL 3 LOWER SHALE SHAKERS(6 TOTAL) , WITH PROPER SEALED FITTINGS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE SEALED FITTING FOR ALL THREE LOWER SHAKER EXPLOSION PROOF SWITCH BOX.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REPLACE MISSING BOLTS CTR. LOWER SHAKER EXPLOSION PROOF SWITCH BOX.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Construction/Loadline
Issued 17 May 1990 Resolved
PROPERLY SUPPORT ALL 1" DIAMETER VERTICAL RUNS ON JACKING TOWERS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROPERLY SUPPORT WIRE RUN TO PORT DRAWWORKS MOTOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Deck/Cargo
Issued 17 May 1990 Resolved
PROVIDE EXCESSIVE HYDRAULIC FLUID FROM DECK PORT/AFT RIG FLOOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE DOCUMENTATION 3 TRNSFORMERS PORT SIDE AFT BULKHEAD ARE SUITABLE FOR CLASS I DIVISION II AREA.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE SEALED FITTING FOR EXPLOSION PROOF SWITCH BOX FOR DYNAMIC ON DRILL-ER'S CONSOLE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE PURGE ALARM FOR DRILLER'S CONSOLE IN ACCORDANCE WITH NFPA-496.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE SEALED FITTINGS ON LIGHTS IN VICINITY OF MUD CIRCULATING PUMPS (CLASS I DIVISION I AREA).
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
REPLACE WASTED BALL VENT COVER #26.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Deck/Cargo
Issued 17 May 1990 Resolved
REPLACE WASTED GLAND NUT CONNECTORS, SERVICE CONTROLS (OR REMOVE) STBD RE- MOTE JACKING STATION.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROPERLY MOUNT GAITRONICS SPEAKER HORN PORT AND STBD CRANE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Construction/Loadline
Issued 17 May 1990 Resolved
PROVE PROPER OPERATION OF BILGE PUMPS AND PUMPING.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
PROVIDE ASME OR EQUIVALENT APPROVAL FOR LOW PRESSURE AIR RECEIVER IN ENGINEROOM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990 Resolved
REPAIR REMOTE FUEL OIL SHUTDOWN
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
CLEAN AND SECURE ELECTRICAL JUNCTION BOX ON QUINCY AIR COMPRESSOR IN ENGINEROOM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
PROVIDE APPROVED RELEIF VALVES FOR TWO MANCHESTER 250 LB AIR RECEIVERS IN ENGINE ROOM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Construction/Loadline
Issued 17 May 1990 Resolved
REPAIR WATERTIGHT DOOR BETWEEN MUD PUMP ROOM AND SACK ROOM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Construction/Loadline
Issued 17 May 1990 Resolved
REPAIR WATERTIGHT DOOR BETWEEN SACK ROOM AND STORAGE ROOM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 17 May 1990 Resolved
REPAIR LIFELINES ON NO. 1 LIFE FLOAT.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE PROPER GLOBE AND SHEILD FOR LIGHT IN STBD CRANE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Fire Fighting
Issued 17 May 1990 Resolved
PROVIDE PROPER BRACKET FOR FIRE EXTINGUISHER ON FORKLIFT.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Deck/Cargo
Issued 17 May 1990 Resolved
PROVIDE DESIGNATED REFUELING AREA FOR FORKLIFT.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Construction/Loadline
Issued 17 May 1990 Resolved
SEAL ALL BULKHEAD PENETRATIONS IN MUD PITS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Deck/Cargo
Issued 17 May 1990 Resolved
PROVIDE PROPER VENTILATION OF MUD PIT LOSS OF VENTILATION ALARM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
PROPERLY MARK GENERAL ALARM HORN IN MUD PITS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Deck/Cargo
Issued 17 May 1990 Resolved
PROPERLY MOUNT ALL GAS DETECTOR SENSORS IN MUD PITS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Unknown
Issued 17 May 1990 Resolved
REMOUNT EXPLOSION PROOF JUNCTION BOX LOCATED BY EXHAUST PLENUM IN MUD PITS
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REPLACE BROKEN SEALED FITTING, REHANG WIRE TO LIGHT IN OVERHEAD OF MUD PITSBY EXHAUST PLENUM.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Deck/Cargo
Issued 17 May 1990 Resolved
REPLACE WASTED COOLING COWLING FOR EXPLOSION PROOF MOTOR PORT AGITATOR MOTOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
RE-HANG PROPERLY ALL HORIZONAL RUNS OF WIRING IN MUD PITS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REPLACE HANGER ON EXPLOSION PROOF LIGHT IN MUD PITS(CENTER) HELD ON FUEL NOZZEL LOCATED ON PORT CRANE REFUELING STATION.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Deck/Cargo
Issued 17 May 1990 Resolved
REMOVE HOLD ON DEVICE ON FUEL NOZZEL LOCATED ON PORT CRANE REFUELING STA- TION.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 17 May 1990 Resolved
REPAIR OR REPLACE FORWARD LIMIT SWITCH NO. 2 LIFERAFT.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 17 May 1990 Resolved
PROVIDE ADEQUATE DRINKING WATER IN LIFEBOATS (816 .125L BAGS/BOAT)
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 17 May 1990 Resolved
REPLACE AIR PRESSURE GAGE IN NO 2 LIFEBOAT (BREATHING AIR).
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
REPLACE WASTED DECK RAILING AS NECESSARY.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
REPAIR OR REPLACE ALL EXTINGUISHED LIGHTS ON HELODECK
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 17 May 1990 Resolved
MARK MECHANICAL DISENGAGING APPARATUS CONTROL LEVER IN NO. 1 AND NO. 2 LIFEBOATS AS REQUIRED BY 46 CFR 108.645.(B).
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Navigation
Issued 17 May 1990 Resolved
PROVE PROPER OPERATION OF OBSTRUCTION LIGHTS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Navigation
Issued 17 May 1990 Resolved
REPAINT NAVIGATION LIGHT SIDE SCREENS, PROVIDE PROPER ARC OF VISIBILTY.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
MAKE ALL AIR RECEIVERS IN ENGINE ROOM AND EMERGENCY GENERATOR ROOM AVAILAB-LE FOR INTERNAL EXAMINATIONS OR HYDROSTATIC EXAMINATION. REMOVE SLUDGE FROM TANKS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 24 July 1989 Resolved
RE-PAINT + RE-STENCIL #2 LIFEBOAT STATION PFD BOX.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Deck/Cargo
Issued 24 July 1989 Resolved
PROVIDE ANNUAL TESTING OF ALL FUEL OIL TRANSFER HOSES TO 225 PSI AND PROVIDE A RECORD OF THE SAME.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Fire Fighting
Issued 24 July 1989 Resolved
PROVIDE SERVICING AND PROVE PROPER OPERATION OF EMERGENCY FUEL TANK SHUT DOWN SYSTEM.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Fire Fighting
Issued 24 July 1989 Resolved
PROVIDE APPROVED 15#CO2 BOTTLE FOR PAINT LOCKER FIXED CO2 SYSTEM.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Construction/Loadline
Issued 24 July 1989 Resolved
PROVIDE PERNAMENT REPAIRS TO FIXED PAINT LOCKER BULKHEAD WHERE HOLED.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Navigation
Issued 24 July 1989 Resolved
PROVE PROPER OPERATION OF NAV LIGHT CONTROL PANEL IN CONTROL ROOM.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Documentation
Issued 24 July 1989 Resolved
SUBMIT VESSEL'S OPERATING MANUAL FOR VERIFICATION FOR COMPLIANCE WITH 46 CFR 109.121 (C) (19) THROUGH (24).
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Documentation
Issued 22 May 1988 Resolved
UPDATE AND SUBMIT FOR APPROVAL BY THE COAST GUARD THE RIG FIRE AND SAFETY PLAN REFLECTING CHANGES ASSOCIATED WITH THE RIG SLOT-TO-CANTILEVER MODIFICATION
Condition: Unknown
Due 22 May 1988
Resolved 22 May 1988
Documentation
Issued 22 May 1988 Resolved
UPDATE AND MAINTAIN ON BOARD THE RIG A COPY OF THE PERMANENT STABILITY BOOKTO REPLACE THE TEMPORARY BOOK ISSUE 20MAY88.
Condition: Unknown
Due 22 May 1988
Resolved 22 May 1988
Electrical
Issued 22 May 1988 Resolved
PERFORM SEMI-ANNUAL EMERGENCY BATTERY LOAD TEST AS OUTLINED IN 46CFR109.211
Condition: Unknown
Due 22 May 1988
Resolved 22 May 1988
Accommodation/Occupational Safety
Issued 1 May 1986 Resolved
CLEAN UP STANDING OIL IN VICINITY OF THE RIG AIR COMPRESSOR.
Condition: Unknown
Due 1 May 1986
Resolved 1 May 1986
Navigation
Issued 1 May 1986 Resolved
REPAIR OR REPLACE THE OBSTRUCTION LIGHT ON THE PORT JACK-HOUSE; LIGHT TO BESET LEVEL.
Condition: Unknown
Due 1 May 1986
Resolved 1 May 1986
Unknown
Issued 28 April 1986 Resolved
REFILL THE BREATHING AIR BOTTLES IN #2 CAPSULE AND REPLACE PRESSURE GAUGE FOR THE CONSOLE BREATHING AIR INDICATOR.
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986
Unknown
Issued 28 April 1986 Resolved
PROVIDE REQUIRED NUMBER OF BREATHING AIR CYLINDERS IN CAPSULE #1 THREE (3) BOTTLES ARE REQUIRED AND ONLY TWO (2) INSTALLED. PROVIDE ALL BOTTLES WITH THE REQUIRED AIR PRESSURE.
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986
Electrical
Issued 4 April 1986 Resolved
PROPERLY SUPPORT ELECTRICAL WIRING RUNS AND REPLACE FRAYED WIRES IN SHAKER SPACE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986 Resolved
PROPERLY CHARGE THE MSO WITH CHEMICALS AND MAKE OPERATIONAL THE COMPRESSOR.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Accommodation/Occupational Safety
Issued 4 April 1986 Resolved
CONDUCT HYDROSTATIC TEST OF THE OIL TRANSFER HOSE PER 33CFR 155.800.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Deck/Cargo
Issued 4 April 1986 Resolved
REPLACE ONE DOG ON #3 CEMENT TANK AND TWO ON THE #2 CEMENT TANK MANHOLES. THREADS WORN ON DOG BOLTS. #2 TANK DOGS ARE TOP AND NEXT DOG TO LEFT.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Deck/Cargo
Issued 4 April 1986 Resolved
PROVIDE LEGIBLE HAND PA SYSTEM(S) IN BOTH CRANES.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986 Resolved
MAKE OPERATIONAL THE OVERSPEED TRIP ON THE EMERGENCY GENERATOR AND SET SPEED NOT TO EXCEED 145% OF THE ENGINES RATED RPM.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986 Resolved
PROVIDE DIP OIL STICK #2 CAPSULE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Unknown
Issued 4 April 1986 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION OR HYDROSTATICALLY TEST THE DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986 Resolved
REPLACE OR REPAIR BOTH LIMIT SWITCHES ON #2 LIFEBOAT DUE TO CORROSION.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986 Resolved
REPLACE LIFELINE PORT SIDE #2 CAPSULE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986 Resolved
REFILL THE BREATHING AIR BOTTLES IN #2 CAPSULE AND REPLACE PRESSURE GAGE FOR THE CONSOLE BREATHING AIR INDICATOR.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986 Resolved
REPLACE TERMINAL BLOCK, MOTOR CONTROLLER #2 LIFEBOAT, DUE TO CORROSION.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986 Resolved
REPLACE BROKEN SIDE GLASS #2 LIFEBOAT.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986 Resolved
REPLACE FALLS ON BOTH LIFEBOATS (CAPSULES) FALLS ARE OUTDATED FALLS INSTALLED 10-2-80 AND 11-8-79 REPLACEMENT REQUIRED DUE TO MANUFACTURES REQUIREMENTS.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Unknown
Issued 4 April 1986 Resolved
PROVIDE REQUIRED NUMBER OF BREATHING AIR CYLINDER IN CAPSULE #1. THREE BOTTLES ARE REQUIRED AND ONLY TWO INSTALLED. PROVIDE ALL BOTTLES WITH THE REQUIRED AIR PRESSURE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986 Resolved
REPLACE PAINTERS ON ALL FOUR LIFEFLOATS DUE TO WEATHERING FROM SUNLIGHT.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986 Resolved
REPAIR THE FLOOR RETAINIG CLIPS IN THE PORT AFTER LIFEFLOAT. CLIPS PULLED OUT OF FLOAT.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Fire Fighting
Issued 4 April 1986 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Fire Fighting
Issued 4 April 1986 Resolved
PROVIDE FIREMAN'S OUTFIT WITH A FULL SCBA AIR BOTTLE; LOCATED MAIN DECK FORWARD STARBOARD SIDE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Navigation
Issued 4 April 1986 Resolved
MAKE OPERATIONAL THE PORT SIDE LIGHT AND PROVIDE THE CORRECT BULB IN THE STERN LIGHT.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Construction/Loadline
Issued 4 April 1986 Resolved
REPAIR OR REPLACE BROKEN DOG, VENT GOOSE NECK, PORT SIDE MAIN DECK.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Accommodation/Occupational Safety
Issued 4 April 1986 Resolved
REPAIR CRACKED WELD, TOP OF LADDER, PIPE RACK TO DRILL FLOOR. WELD IS CRACKED AT THE BASE OF THE UPPER MOST, STBD VERTICAL MEMBER.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Accommodation/Occupational Safety
Issued 4 April 1986 Resolved
REPAIR OR REPLACE RUNGS ON THE LADDER LOCATED IN THE KEYWAY. LADDER HAS CONCRETE FILLED RUNGS THAT ARE SPALDING AWAY.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Deck/Cargo
Issued 4 April 1986 Resolved
PROPERLY MARK ALL HYDROLIC OIL STORAGE TANKS AND RESERVE TANKS LOCATED ON THE JACKING STATIONS PER 46CFR 109.573
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Unknown
Issued 4 April 1986 Resolved
REPLACE MISSING SCREENS ON ALL BALLAST, VOID AND PRELOAD TANK VENTS.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Deck/Cargo
Issued 4 April 1986 Resolved
PROVIDE FIRE EXTINGUISHER ON THE FORKLIFT.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Fire Fighting
Issued 4 April 1986 Resolved
PROVIDE DOCUMENTATION INDICATING THE APPROVAL ON THE TV CAMERA ON THE DRILLFLOOR FOR USE IN A HAZARDOUS LOCATION, GLASS I DIV.II.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986 Resolved
PROPERLY MAKE SPLICES IN VICINITY OF DRILLER CONSOLE OR REMOVE AND RERUN WIRES WITHOUT SPLICES.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986 Resolved
POUR EYS FITTING (CHICO) FOR MONITOR, LOCATED NEXT TO DRILLERS CONSOLE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Unknown
Issued 4 April 1986 Resolved
PROVIDE RELIEF VALVES SET AT 40 PSI FOR 4 OUT OF THE 6 "P" TANKS. TWO RELIEF VALVES WERE TESTED SATISFACTORY.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Deck/Cargo
Issued 4 April 1986 Resolved
PROVIDE RELIEF VALVES FOR THE PORTABLE HOT WATER HEATERS SET AT LESS THAN 100 PSI AND LESS THAN 200 F OR MAKE AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Accommodation/Occupational Safety
Issued 4 April 1986 Resolved
REPAIR OIL LEAK ON RIG AIR COMPRESSOR.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Engineering
Issued 4 April 1986 Resolved
REPAIR BROKEN SIGHT GLASS ON OIL TANK IN MUD PUMP ROOM.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 September 1985 Resolved
REPAIR THE PRIME MOVER TO GENERATOR COUPLING OF THE EMERGENCY GENERATOR AND CONDUCT AN OVERSPEED SHUTDOWN TEST. 46 CFR 107.231 NVC 4-78
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Documentation
Issued 24 July 1985 Resolved
PROVIDE TO A U. S. COAST GUARD MARINE INSPECTOR THE APPROVED MODU CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Electrical
Issued 24 July 1985 Resolved
INSTALL AN EYS FITTING ON THE GENERAL ALARM BELL NEXT TO THE SHALESHAKER.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Construction/Loadline
Issued 24 July 1985 Resolved
REPAIR OR REPLACE THE SCUPPER PIPING TO THE DRAINAGE PAN ON THE RIG PORT BOW JUST FORWARD OF NO. 2 LIFEBOAT.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Electrical
Issued 24 July 1985 Resolved
ADJUST THE SPEED CONTROL GOVERNOR ON THE EMERGENCY GENERATOR AND CONDUCT TEST OF ITS OVERSPEED TRIP AND REVERSE POWER RELAY.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Lifesaving
Issued 24 July 1985 Resolved
PROVIDE EVIDENCE OF THE LAST FUEL CHANGE OR CHANGE OUT THE FUEL OF THE PORTAND STARBOARD LIFEBOATS.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Accommodation/Occupational Safety
Issued 24 July 1985 Resolved
RENEW OR REPLACE THE MOTOR CONTROLLER BOX FOR THE MARINE SANITATION DEVICE CHEMICAL PUMP.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Engineering
Issued 24 July 1985 Resolved
FREE UP THE REMOTE OPERATED FUEL OIL VALVE FOR THE DIESEL OIL DAY TANK.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Accommodation/Occupational Safety
Issued 24 July 1985 Resolved
POST LEGIBLE MANUFACTURER'S INSTRUCTIONS ON THE MARINE SANITATION DEVICE IN A LOCATION VISIBLE TO ALL PERSONNEL.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Lifesaving
Issued 24 July 1985 Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Electrical
Issued 24 July 1985 Resolved
REMOVE THE TWO INOPERATIVE POWER SWITCHES ON THE STARBOARD BULKHEAD OF THE SHALESHAKER AREA.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Electrical
Issued 24 July 1985 Resolved
PROPERLY MOUNT THE EXPLOSION PROOF JUNCTION BOX BEHIND THE DRILLER'S CONSOLE.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Electrical
Issued 24 July 1985 Resolved
LABEL AND REPAIR THE GENERAL ALARM BELL IN THE MUD PIT ROOM AND REPAIR OR REPLACE THE GENERAL ALARM SIREN IN THE SACK ROOM.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Lifesaving
Issued 24 July 1985 Resolved
PROVIDE 12 RED FLARE DISTRESS SIGNALS FOR THE PORT LIFEBOAT.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Fire Fighting
Issued 24 July 1985 Resolved
REPLACE OR CONDUCT A HYDROSTATIC TEST ON THE TWO SCBA AIR TANKS IN THE FIREMAN'S OUTFITS.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Fire Fighting
Issued 24 July 1985 Resolved
PROVIDE COMBUSTIBLE GAS/OXYGEN DETECTION METER CALIBRATION GAS AND SHOW PROPER DEVICE OPERATION.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Navigation
Issued 24 July 1985 Resolved
PROVIDE PROTECTION FOR THE BOW LEG OBSTRUCTION/NAVIGATION LIGHTS FROM THE DIRECT EXHAUST OF THE SHIP'S SERVICE GENERATORS.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Navigation
Issued 24 July 1985 Resolved
SUBMIT A PROPOSAL TO PROTECT THE BOW LEG OBSTRUCTION LIGHT AND NOT-UNDER- COMMAND/SPECIAL OPS LIGHTS FROM DIRECT S.S. GENERATOR EXHAUST.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Lifesaving
Issued 24 July 1985 Resolved
PROVIDE SIX (6) HANDHELD ROCKET PROPELLED RED FLARES PRIOR TO RIG MOVEMENT.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Construction/Loadline
Issued 24 July 1985 Resolved
REPLACE OR REPAIR THE SCUPPER DRAINAGE PAN ON THE PORT QUARTER AFT OF THE PORT LEG.
Condition: Unknown
Due 24 July 1985
Resolved 24 July 1985
Lifesaving
Issued 19 March 1985 Resolved
REPAIR OR REPLACE UPPER WATER SPRAY BAR ON CAPSULE #2 WITHIN THIRTY (30) DAYS IAW 46 CFR 108.503
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Lifesaving
Issued 19 March 1985 Resolved
PROVIDE (12) HAND FLARE DISTRESS SIGNALS FOR CAPSULE #1(STBD SIDE) WITHIN FOURTEEN (14) DAYS IAW 46 CFR 94.20-15
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Unknown
Issued 18 December 1984 Resolved
REPAIR OR REPLACE THE SEA VALVE AND CHECK VALVE IN PRELOAD TANK #19.
Condition: Unknown
Due 18 December 1984
Resolved 18 December 1984
Lifesaving
Issued 18 December 1984 Resolved
MAKE PERMANENT REPAIRS TO THE STBD SRUVIVAL CAPSULE & REINSTALL IN PROPER LOCATION, DURING INTERIM PERIOD, PROVIDE INFLATABLE LIFERAFTS WITH SUFFI- CIENT CAPACITY TO HOLD 34 PERSONS. ALSO, A STANDBY BOAT WILL BE REQUIRED AT RIG'S LOCATION UNTIL CAPSULE IS REPAIRED, RETURNED & PROPERLY INSTALLED.
Condition: Unknown
Due 18 December 1984
Resolved 18 December 1984
Construction/Loadline
Issued 14 September 1984 Resolved
REPLACE THE BILGE AND BALLAST OVERBOARD VALVE.
Condition: Unknown
Due 14 September 1984
Resolved 14 September 1984
Unknown
Issued 14 September 1984 Resolved
CONDUCT THE UNDERWATER PORTION OF THE SPECIAL EXAMINATION IN LIEU OF DRY- DOCKING (LEG TO INDEPENDENT CAN CONNECTIONS, CAN EXTERIOR). EXAMINATION TOBE COMPLETED AT THE NEXT RIG MOVE.
Condition: Unknown
Due 14 September 1984
Resolved 14 September 1984
Construction/Loadline
Issued 14 September 1984 Resolved
REWORK THE CHECK VALVES IN TANK #35 AND #19.
Condition: Unknown
Due 14 September 1984
Resolved 14 September 1984
Unknown
Issued 23 May 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE TRANSWORLD 64, CG027847.
Condition: Unknown
Due 23 May 1984
Resolved 23 May 1984
Unknown
Issued 23 May 1984 Resolved
REPAIR PURGE ALARM ON THE FOLLOWING: DATA STAR MONITOR OVER DRILLERS CON- SOLE; CAMERA UNITS ON DRILL FLOOR AND SHALE SHAKER RM; DRILLING CONSOLE.
Condition: Unknown
Due 23 May 1984
Resolved 23 May 1984
Electrical
Issued 23 May 1984 Resolved
PROVIDE EMERGENCY LIGHTING FOR CAPSULES AND LIFE FLOATS.
Condition: Unknown
Due 23 May 1984
Resolved 23 May 1984
Navigation
Issued 23 May 1984 Resolved
PROVIDE NOT UNDER COMMAND LIGHTS AND ANCHOR LIGHT.
Condition: Unknown
Due 23 May 1984
Resolved 23 May 1984
Fire Fighting
Issued 23 May 1984 Resolved
REPAIR ALL DEFECTIVE FIRE DOORS IN QUARTERS AS NEEDED.
Condition: Unknown
Due 23 May 1984
Resolved 23 May 1984
Electrical
Issued 23 May 1984 Resolved
REPAIR OVERHEAD LIGHTS, LIGHT COVERS, AND GLOBES AS NEEDED THROUGHOUT QUARTERS.
Condition: Unknown
Due 23 May 1984
Resolved 23 May 1984
Unknown
Issued 23 May 1984 Resolved
CONDUCT A FIRE AND ABANDON RIG DRILL.
Condition: Unknown
Due 23 May 1984
Resolved 23 May 1984
Unknown
Issued 23 May 1984 Resolved
PROVIDE SUITABLE CONTAINMENT FOR FUEL TAKE ON MANIFOLDS.
Condition: Unknown
Due 23 May 1984
Resolved 23 May 1984
Unknown
Issued 6 April 1984 Resolved
FIND OUT WHAT ALARM SWITCH #19 IN TOOL PUSHER'S ROOM IS FOR AND MAKE OPERA-BLE AND STENCIL.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Accommodation/Occupational Safety
Issued 6 April 1984 Resolved
REPLACE BACK COVER ON WASHER.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Documentation
Issued 6 April 1984 Resolved
REVISE FIRE AND LIFESAVING PLAN COPIES AROUND RIG AS NEEDED.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
MAKE OPERABLE OR REMOVE GENERAL ALARM HORN ON STARBOARD SIDE OF QUARTERS.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Construction/Loadline
Issued 6 April 1984 Resolved
CLEAN OUT FUEL VENT CONTAINMENTS AND PROVIDE PLUGS FOR CONTAINMENT.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
MAKE TV CAMERA ON DRILL FLOOR EXPLOSION PROOF.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
RESUPPORT CABLES IN SHALE SHAKER AREA AS NEEDED.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
PROPERLY RESUPPORT WIRE CABLES IN TRAY AND ALONG CONTROL HOUSE BULKHEAD.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
REMOVE LOOSE WIRING IN CONTROL HOUSE.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Lifesaving
Issued 6 April 1984 Resolved
REPLACE RING BUOYS LOCATED AT STARBOARD ANCHOR AND STARBOARD LEG.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Lifesaving
Issued 6 April 1984 Resolved
PROVIDE EMERGENCY LIGHTING FOR CAPSULES AND LIFE FLOATS.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Lifesaving
Issued 6 April 1984 Resolved
STENCIL EMERGENCY ESCAPE LADDER AND ROPES.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Lifesaving
Issued 6 April 1984 Resolved
RESTENCIL RESCUE BOAT AND SERVICE PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Lifesaving
Issued 6 April 1984 Resolved
REPLACE MISSING ITEMS IN CAPSULES: CAPS #1, 2 HEAVING LINES, EQUIP LIST, DISTRESS SIGNAL, MAINTENANCE SCH. CAPS #2, FISH KIT, EQUIP LIST, MAINT SCH.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Documentation
Issued 6 April 1984 Resolved
UPDATE CRANE RECORD BOOK.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Documentation
Issued 6 April 1984 Resolved
DESIGNATE CRANE OPERATORS IN WRITING.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Documentation
Issued 6 April 1984 Resolved
DESIGNATE MASTER IN WRITING.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Documentation
Issued 6 April 1984 Resolved
OBTAIN ANNUAL ENDORSEMENT ON LOADLINE.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
CONDUCT FIRE AND ABANDON RIG DRILLS.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE TRANSWORLD 64, CG027847.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
SUPPORT ALL LOOSE WIRING IN JACK HOUSES.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Navigation
Issued 6 April 1984 Resolved
CLEAN OBSTRUCTION LIGHTS LENS AND STERN LIGHT LENS.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
PROVIDE RUBBER MATTING FOR ELECTRIC PANELS IN THE JACK HOUSE ROOMS.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Construction/Loadline
Issued 6 April 1984 Resolved
REWORK ALL WATER TIGHT DOORS AROUND RIG AS NEEDED; FREE DOGS, CORRECT MISALIGNMENT, ETC.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Construction/Loadline
Issued 6 April 1984 Resolved
REPAIR SOUNDING TUBE IN CEMENT ROOM.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Navigation
Issued 6 April 1984 Resolved
REPAIR STARBOARD OBSTRUCTION LIGHT.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Construction/Loadline
Issued 6 April 1984 Resolved
REWORK PORT MUD PIT DOOR AND MAKE IT SELF-CLOSING.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
PROVIDE SUITABLE CONTAINMENT FOR FUEL TAKE ON MANIFOLDS.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
REPAIR ALL HELIPORT LIGHTS AS NEEDED.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
REMOVE, OR MAKE SUITABLE FOR HAZARDOUS LOCATIONS, THE JUNCTION BOX FOR THE CAMERA, LOCATED IN THE SHALE SHAKER AREA.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Lifesaving
Issued 6 April 1984 Resolved
PROVIDE ALL NECESSARY EQUIPMENT FOR LINE THROWING GUN.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
REMOVE OR REPAIR SOUND POWERED PHONE SYSTEM.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
RELINE FOG HORN BATTERY BOX.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
STENCIL WORK VEST BINS.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
REPAIR JUNCTION BOX FOR GENERAL ALARM BELL IN EMERGENCY GENERATOR ROOM AND ALSO REMOUNT THE GENERAL ALARM SIGN IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Accommodation/Occupational Safety
Issued 6 April 1984 Resolved
REPAIR AIR CONDITIONER REMOTE SHUT DOWN SWITCH.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
STENCIL OR LABEL ALL MOTOR CONTROLLERS, VALVE WHEELS, EMERGENCY LIGHTS, GENERAL ALARM HORNS & BELLS, VENTS, LOADING MANIFOLDS, ETC AS NEEDED.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Construction/Loadline
Issued 6 April 1984 Resolved
MAKE HATCHES WATER TIGHT TO SACK ROOM AND HALLIBUTON ROOM.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
RESUPPORT WIRING IN CABLE TRAY ON DRILL FLOOR.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
REPLACE ALL MISSING BOLTS TO ELECTRIC BOXES ON DRILL FLOOR AND REPAIR RESETBUTTONS ON ELECTRIC BOXES AS NEEDED.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Fire Fighting
Issued 6 April 1984 Resolved
MAKE ALL FIRE DOORS IN QUARTERS SELF-CLOSING AS NEEDED.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
REPAIR ALL OVER HEAD LIGHTS, BUNK LIGHTS, COVERS, GLOBES, ETC. AS NEEDED THROUGHTOUT THE RIG.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Accommodation/Occupational Safety
Issued 6 April 1984 Resolved
REPAIR ALL DEFECTIVE CEILING PANELS IN QUARTERS AS NECESSARY.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Accommodation/Occupational Safety
Issued 6 April 1984 Resolved
REMOVE ALL LOCKING DEVICES FROM MACHINERY AND QUARTERS DOORS.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Navigation
Issued 6 April 1984 Resolved
REPAIR DEFECTIVE FOG HORN.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Navigation
Issued 6 April 1984 Resolved
REPAIR THE PORT SIDE LIGHT. REPAINT SIDE LIGHT SCREENS BLACK.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Navigation
Issued 6 April 1984 Resolved
PROVIDE NOT UNDER COMMAND LIGHTS (RED OVER RED) AND ANCHOR LIGHT.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Fire Fighting
Issued 6 April 1984 Resolved
SERVICE B-V SEMI-PORTABLE EXTINGUISHER NEAR HELIPORT.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
REPLACE GLASS TO PORT STAIRWAY ENGINE ROOM ACCESS GENERAL ALARM CONTACT MAKER.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
REPAIR OVER SPEED TRIP INDICATORS TO ALL MAIN GENERATORS.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
INTERNALLY EXAMINE RIG AIR RECIEVERS AND TEST RELIEFS.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Electrical
Issued 6 April 1984 Resolved
TEST AIR PURGE SYSTEM FOR ALL APPLICBLE UNITS ON DRILL FLOOR.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 6 April 1984 Resolved
MAKE GENERAL ALARM HORN ON DRILL FLOOR OPERABLE.
Condition: Unknown
Due 6 April 1984
Resolved 6 April 1984
Unknown
Issued 10 August 1983 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE TRANSWORLD 64, CG027847.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Unknown
Issued 10 August 1983 Resolved
PRIOR TO COMMENCING DRILLING OPERATIONS, REPAIR THE REVERSE POWER RELAY FORTHE NUMBER ONE GENERATOR.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Unknown
Issued 10 August 1983 Resolved
PRIOR TO COMMENCING DRILLING OPERATIONS, PLACE THE AIR PURGE WARNING LABELSON ALL PURGED EQUIPMENT AS REQUIRED BY NFPA 496.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Unknown
Issued 12 May 1983 Resolved
REVISE,UPDATE AND SUBMIT FOR APPROVAL THE RIGS FIRE-FIGHTING AND LIFE SAVING PLAN.
Condition: Unknown
Due 12 May 1983
Resolved 12 May 1983
Unknown
Issued 12 May 1983 Resolved
COMPLETE THE ATTACHED 17 ITEM WORK LIST DATED 12 MAY 1983.
Condition: Unknown
Due 12 May 1983
Resolved 12 May 1983
Unknown
Issued 12 May 1983 Resolved
REMOVE THE 15 LB. FIXED CO2 FIRE EXTINGUISHER FOR THE PAINT LOCKER AND RE- PLACE WITH A 50 LB. FIXED CO2 SYSTEM AS REQUIRED.
Condition: Unknown
Due 12 May 1983
Resolved 12 May 1983
Unknown
Issued 12 May 1983 Resolved
PROVIDE ON BOARD 2 CERTIFICATED LIFEBOATMEN AS REQUIRED BY THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 12 May 1983
Resolved 12 May 1983
Unknown
Issued 12 May 1983 Resolved
INSTALL FIRE STATION ON THE DRILL FLOOR IAW THE RIGS FIRE FIGHTING PLAN. PROVIDE 2-50FT.HOSES AT STATIONS 10&12 UNTIL INSTALLATION IS COMPLETED.
Condition: Unknown
Due 12 May 1983
Resolved 12 May 1983
Unknown
Issued 6 April 1982 Resolved
REPAIR OR REPLACE THE #3 LIFEFLOAT.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
REPLACE THE DEFECTIVE RING BUOY LOCATING NEAR THE PORT SAFETY CAPSULE.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PROVIDE DOCUMENTATION TO PROVE THAT THE MSD IS COAST GUARD APPROVED.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PROPERLY VENT THE DECK BATTERY BOXES.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PROPERLY MAKE THE DECK BATTERY BOXES.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PROVIDE PROOF OF UL/FM APPROVAL FOR THE EMERGENCY LIGHTING IN THE MUD PIT ROOM.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PROVIDE AN APPROVED OPERATING MANUAL.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PREPARE FOR INTERNAL INSPECTION THE FOLLOWING PRESSURE VESSELS: (1) ALL RIG AIR RECEIVERS, (2) EMERGENCY GENERATOR AIR RECEIVER.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
TEST THE RELIEF VALVES TO BOTH RIG AIR TANKS AND THE EMERGENCY AIR TANKS.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
REPAIR THE #1 SUBMERSIBLE PUMP.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PROVIDE AN APPROVED STABILITY LETTER.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PROPERLY SEAL ALL BULKHEAD PENETRATIONS IN THE MUD PIT ROOM.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
TEST THE FUEL OIL REMOTE SHUT DOWN.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PLACE ONE OF RING BUOYS WITH THE SMOKE SIGNALS ON THE STARBOARD SIDE.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
CONDUCT A FIRE AND ABANDON RIG DRILL.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
CLEAN ALL THE EMERGENCY LIGHTS THROUGHOUT THE RIG.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
REPAIR THE DEFECTIVE RAILING IN THE AREA OF THE SHALE SHAKER ROOM.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PROPERLY STENCIL THE SAFETY CAPSULE.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
REPAIR THE DEFECTIVE WINCH MOTOR ON THE DAVIT.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PROVIDE DATED LOAD CHART FOR THE FORKLIFT.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
TEST AND MAKE OPERABLE THE FORWARD ANCHOR WINDLASS.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
TEST AND MAKE OPERBLE THE AFT ANCHOR WINDLASS.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
PROVIDE WIND DIRECTIONAL DEVICE FOR THE HELIPORT.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
TEST AND RECORD THE FUEL OIL TRANSFER HOSES IN ACCORDANCE WITH 33 CFR 154.500.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
TEST THE OVERSPEED TRIPS, LUBE OIL ALARMS AND REVERSE POWER RELAYS ON ALL SERVICE GENERATORS.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
TEST THE OPERATION OF THE EMERGENCY POWERED GENERATOR UNDER LOAD.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982
Unknown
Issued 6 April 1982 Resolved
LABEL ALL MOTOR CONTROLERS THROUGHOUT THE RIG.
Condition: Unknown
Due 6 April 1982
Resolved 6 April 1982

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.