Records from 1981 to 2003. Most recent: inspection, 10 March 2003.
Inspection history · 36
10 March 2003
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1756424
26 March 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1597723
6 December 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1488929
4 May 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376583
7 February 2001
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059833
29 September 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 64340
7 April 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384297
12 February 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 766844
1 January 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 196905
30 December 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378536
8 April 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 788947
16 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 37014
16 March 1998
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1109613
13 February 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442683
31 December 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428714
31 January 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458275
10 January 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355053
18 January 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354539
6 January 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373774
29 November 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938865
8 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234049
6 February 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241505
6 March 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1292184
29 January 1990
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230531
17 February 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348702
8 March 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1340883
13 March 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018997
31 March 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000681
31 January 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993898
4 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291700
17 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282276
1 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273421
18 November 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969054
12 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964924
13 January 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274217
30 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271838
Fire Fighting › Fire Pumps
Issued 2 April 2003
Resolved
Provide a gauge on the discharge side of the pump. LEGACY COMPONENT DESC: Pressure
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 4 April 2003
Engineering › Compressed Air System (start air)
Issued 2 April 2003
Resolved
Provide the proper size relief valve on the air compressor. LEGACY COMPONENT DESC: Compressor
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 4 April 2003
Lifesaving › Buoyant Apparatus
Issued 2 April 2003
Resolved
Make-up the life float painter in a float free design. LEGACY COMPONENT DESC: Life Float
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2003
Resolved 4 April 2003
Personnel › Certificates/Documents/Licenses
Issued 26 March 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 26 March 2002
Resolved 26 March 2002
Navigation › Collision/Grounding Avoidance
Issued 26 March 2002
Resolved
COMPASS DEVIATION TABLE OUT OF DATE. LEGACY COMPONENT DESC: COMPASS
Due 26 March 2002
Resolved 26 March 2002
Fire Fighting › Portable Foam Applicators
Issued 26 March 2002
Resolved
NO ADDITIONAL FIRE PROTECTION FOR THE CARRIAGE OF MARINE PORTABLE TANKS.
Due 26 March 2002
Resolved 26 March 2002
Stability › Watertight Integrity
Issued 26 March 2002
Resolved
RUDDER ROOM HAS NO INSTALLED BILGE ALARM. LEGACY COMPONENT DESC: BILGE ALARM
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 26 March 2002
Operations/Management › Navigation Safety › Requirements for Vessels at Anchor
Issued 26 March 2002
Resolved
ANCHOR ASSEMBLY INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 26 March 2002
Engineering › Bilge Water Management System
Issued 26 March 2002
Resolved
ENGINE ROOM BILGES HAS EXCESSIVE OILY WASTE SLOPS. LEGACY COMPONENT DESC: EXCESS OIL IN BILGES
Due 26 March 2002
Resolved 26 March 2002
Engineering › Fuel Oil Service System › Filter
Issued 26 March 2002
Resolved
STARBOARD MAIN DIESEL ENGINE RACOR ASSEMBLY LEAKS FUEL.
Due 26 March 2002
Resolved 26 March 2002
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 26 March 2002
Resolved
MAIN SWITCHBOARD GROUND DETECTION LIGHTS INOPERABLE.
Due 26 March 2002
Resolved 26 March 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 26 March 2002
Resolved
CARGO TRANSFER HOSES NOT ANNUALLY TESTED. LEGACY COMPONENT DESC: Transfer Hose
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2002
Resolved 26 March 2002
Engineering › Reduction Gearing/Clutches
Issued 26 March 2002
Resolved
CONDEMNED CLUTCH OPERATING HOSE. LEGACY COMPONENT DESC: HOSES
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2002
Resolved 26 March 2002
Construction/Loadline
Issued 7 February 2001
Resolved
COMPLETE REPAIRS TO THE STBD AFT BALLAST BOTTOM PLATE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 February 2001
Resolved 13 April 2001
Construction/Loadline
Issued 16 March 1998
Resolved
Proceed to Bollingers Lockport LA from Fourchon LA to effect permanent repairs to damage in side shell vicinity of forward starboard bow and aft._x001C_18" horizontal split in sideshell at maindeck seam (aft portion of #2 ballat tank).
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Engineering
Issued 6 February 1991
Resolved
PROVIDE STARTS AND STOPS FOR BOTH MAIN ENGINES IN PILOTHOUSE IAW _x001C_ 46CFR 175.10-29.
Condition: Unknown
Due 6 February 1991
Resolved 6 February 1991
Electrical
Issued 29 January 1990
Resolved
PROVE PROPER OPERATION OF THE BLOWER REMOTE SHUTDOWN. AS PER 46 CFR 92.15.
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990