EXCALIBUR

Built
1979
Last inspected
18 December 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 December 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK3973
Flag
UNITED STATES
Maury page id
psix-51418

Documentation record

Registered dimensions (L × B × D)75.0 ft × 25.0 ft × 6.0 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRALPH'S BOAT WORKS · GARDENA, CA, UNITED STATES · built 1979
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 19 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 37 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

18 December 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8285284
8 September 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8231631
3 February 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8067710
9 October 2024 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8016840
20 February 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7867546
15 December 2023 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7839425
1 August 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7789838
12 April 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7667520
28 April 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7439793
13 December 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7376264
11 August 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7285210
16 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7176738
30 January 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6899496
27 January 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6897409
16 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6836035
2 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6675561
12 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539000
31 July 2018 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6496708
24 April 2018 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6398370
24 April 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6398717
28 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314122
8 May 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6085385
22 April 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6131552
4 December 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6052771
26 April 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829332
12 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829315
30 March 2016 Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5833584

Deficiency record · 37

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 February 2026 Resolved
Vessel does not have adequate means of escape as required by 46 CFR 177.500. Rectify prior to the carriage of passengers. 46CFR177.500
Action required: 705 - Other - as specified
Due 5 May 2026
Resolved 5 May 2026
Resolution: Marine Inspector observed vessel satisfactorily conduct emergency egress of 35 passengers using alternative routes as means of escape.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 February 2025 Resolved
Each vessel certificated to operate on an oceans route in cold water must be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Liferafts not onboard vessel. Provide life rafts. 46 CFR 180.202
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2025
Resolution: New life rafts onboard vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2025 Resolved
Fixed gas fire extinguishing system design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. Glass was broken on break-glass pull handle for CO2 system. Provide glass for pull handle. 46 CFR 181.410
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2025
Resolved 11 April 2025
Resolution: Glass for pull handle provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2025 Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Existing vessels as of July 22, 2016 have 180 days to comply with this requirement. Spanner wrench missing. Provide spanner wrenches. 46 CFR 181.310(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 April 2025
Resolution: Spanner wrenches provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2025 Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. A nozzle on a vessel of not more than 65 feet in length carrying more than 49 passengers must: (1) Be of a type approved in accordance with approval series 162.027; or (2) Be of a type recognized by the Commandant as being equivalent in performance. Current nozzle onboard vessel is plastic and does not meet 162.027. Provide nozzle that meets 162.027. 46 CFR 181.320(d)
Action required: 10 - Deficiency Rectified
Due 3 February 2025
Resolved 3 February 2025
Resolution: New nozzles provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2025 Resolved
Battery installations must be mounted to protect against shifting of the vessel and free from exposure to water splash or spray. Vessel's battery covers were unsecured and do not adequately cover the existing battery configuration. Provide suitable protection against exposure to water or spray. 46 CFR 183.350
Action required: 10 - Deficiency Rectified
Resolved 3 February 2025
Resolution: Battery box lids provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 February 2025 Resolved
Vessel required to have one 20" or 24" ring lifebuoy fitted with 60' lifeline and floating water light attached with a corrosion resistant clip to allow quick disconnect. Ring lifebouy did not have waterlight attached. Provide proper arrangement of ring lifebuoy, lifeline, and waterlight. 46 CFR 180.70
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2025
Resolution: Ring provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 February 2025 Resolved
For a grill or similar type of cooking appliance, means must be provided to collect grease or fat and to prevent its spillage on wiring or the deck. Grease hood, fan, and ducting create a fire hazard. Clean grease hood, fan, and ducting. 46 CFR 184.220(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2025
Resolved 11 April 2025
Resolution: Grease hood cleaned.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 October 2024 Resolved
Observed fasteners applied at the seams of sistered frames for steering system at the aft bulkhead. Vessel is to add thru bolts to the aft framing (sistered) adjacent to fasteners for the steering system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2024
Resolution: Vessel provided images of thru bolts for stantions, all SAT
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 15 December 2023 Resolved
-Scrape and treat longitudinal outboard/forward of each main engine.
Action required: 705 - Other - as specified
Resolved 28 December 2023
Resolution: Area was properly treated.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 15 December 2023 Resolved
-Scrape and treat overhead deck beam IWO of stbd water tank.
Action required: 705 - Other - as specified
Resolved 28 December 2023
Resolution: Area was properly treated.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 April 2023 Resolved
Vessel port side fire hose found to be punctured. Replace fire hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2023
Resolved 13 April 2023
Resolution: Replaced fire hose.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 April 2023 Resolved
Bunk room emergency escape illuminated signs found to be inoperative. Repair or replace illuminated signs.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 April 2023
Resolution: Replaced both signs with new.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 12 April 2023 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150°F, must be suitably insulated where necessary to prevent injuries. Turbo chargers on both generators found to not be insulated. Install insulation.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2023
Resolved 15 November 2023
Resolution: Vessel POC provided proof that liquid cooled turbo's were operating as designed and present minimal risk of injury.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 16 April 2021 Resolved
Replace expired Hydro-static release unit & EPIRB expired battery and install a new one.
Action required: 10 - Deficiency Rectified
Resolved 16 April 2021
Resolution: Rectified on spot
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 April 2021 Resolved
Provide 06 additional distress signals.
Action required: 10 - Deficiency Rectified
Resolved 16 April 2021
Resolution: Rectified on spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2021 Resolved
Hardware thermometer and place dead end wiring in junction box in captains cabin.
Action required: 10 - Deficiency Rectified
Resolved 16 April 2021
Resolution: Rectified on spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2020 Resolved
Replace 02 defective life jacket lights.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 3 February 2020
Resolution: Replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 January 2020 Resolved
Provide first aid kit instructions.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 3 February 2020
Resolution: Provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 16 January 2020
Resolved 16 April 2021
Resolution: Received completed copy. Verified accuracy on board. Added diagram to vessel files.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
All electrical panels must be in compliance with safety regulations under Code of Federal Regulations and IEEE. Distribution panel in the galley had openings that needed to be blanked. Must rectify deficiency to the satisfaction of the CG Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 16 October 2019
Resolved 16 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 October 2019 Resolved
Portable fire extinguishers must be readily accessible for the space being protected. 01 portable extinguisher in pilot house was found discharged/empty. Recharge as required to satisfaction of CG Marine Inspector prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2019
Resolved 16 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 May 2019
Resolution: Verified in VIVS.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 July 2018 Resolved
Install ventilation closure devices on P & S intake/exhuast on engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: Closures installed and tested
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 31 July 2018 Resolved
Install embarkation ladder for liferafts
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: Ladder installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 31 July 2018 Resolved
Make aft engine room bulkhead watertight around penentrations
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2018
Resolved 1 August 2018
Resolution: aft engine room is now vaportight and water tight.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 July 2018 Resolved
provide additional 06 parachute rockets for oceans zone III
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: Proper amount of flares onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2018 Resolved
secure hydraulic lines for windlass in forepeak
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 1 August 2018
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 31 July 2018 Resolved
Install cover on light in forward passenger compartment.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 1 August 2018
Resolution: cover installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2018 Resolved
Renew both flexible hose on forward bilge suctions in engineroom
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 1 August 2018
Resolution: hoses replaced
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 31 July 2018 Resolved
install shaft guards on both bilge pumps.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 1 August 2018
Resolution: Guards installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 July 2018 Resolved
Properly label lifejackets stowage.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 1 August 2018
Resolution: Properly labeled
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 July 2018 Resolved
Properly install covers on battery boxes.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 1 August 2018
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 31 July 2018 Resolved
Provide emergency broadcast placard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 1 August 2018
Personnel › Training › Passenger Safety
Issued 24 April 2018 Resolved
Vessel to conduct new to zone COI inspection prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2018
Resolution: Conducted inspection.
Construction/Loadline › Hull › Hull Plating
Issued 26 April 2016 Resolved
Clean and treat surface wood rot in engine room and lazarette, in identified areas.
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 26 June 2016
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 April 2016 Resolved
Expired batteries on all (6) Life floats
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 22 April 2016
Resolution: Def cleared

Recorded names · 1

GREAT ESCAPE (2006–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.