Records from 1985 to 2026. Most recent: inspection, 27 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 73
27 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8338851
11 February 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8309312
20 November 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8281913
22 November 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8038434
8 February 2024
In-Service Inspection · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7862708
16 November 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7825704
21 September 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7798526
25 May 2023
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7688985
18 November 2022
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7596699
17 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7464027
3 March 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7405952
15 January 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7125160
3 December 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7105792
2 April 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6934431
21 November 2019
MTSA Verification · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6856241
14 November 2018
Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6581808
26 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6400053
16 November 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6320874
2 November 2016
Administrative Inspection · Security Plan Review - ASP · DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6034003
3 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5828841
12 November 2015
Deficiency Check · DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5762930
12 November 2010
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3889902
19 November 2008
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3366127
16 April 2008
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3212541
29 November 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3109069
19 April 2006
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2637792
14 December 2005
MTSA Verification · Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2552258
9 December 2004
Periodic Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2256756
29 April 2004
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2055072
29 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997531
15 December 2003
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1964135
28 May 2003
Deficiency Check · In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1803606
11 December 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1717687
25 April 2002
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1611081
29 November 2001
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1423690
6 March 2001
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1059116
17 April 2000
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1406696
8 December 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1391161
17 December 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 809174
14 April 1998
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1461040
10 December 1997
Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1364475
10 December 1996
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1434511
19 March 1996
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1402222
12 February 1996
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1374530
11 May 1995
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 905277
24 March 1995
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1453112
15 December 1994
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1141389
24 March 1994
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1457158
27 December 1993
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 851462
14 December 1993
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 849191
23 March 1993
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 832399
16 December 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1401675
23 March 1992
Deficiency Check · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1318267
17 December 1991
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1262122
23 May 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 942897
19 March 1991
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1235389
5 March 1991
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 930075
4 May 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1232642
31 March 1990
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1234341
19 March 1990
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 907082
7 March 1990
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 905976
28 June 1989
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1039471
12 April 1989
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1342172
9 March 1989
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1199508
8 March 1988
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1295047
18 February 1988
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1028882
22 April 1987
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1320192
5 March 1987
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1311779
30 September 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1004619
26 March 1986
Credit Drydock
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1305052
10 March 1986
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 993806
15 April 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 982597
14 March 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1289746
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 16 November 2023
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Upper port life float's waterlight was inop.
46CFR180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 December 2023
Resolved 16 November 2023
Resolution: New waterlight battery was installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 November 2023
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. No drills have been logged for 6 months.
46CFR185.520 & 46CFR185.524
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 1 December 2023
Resolved 16 November 2023
Resolution: Drills were logged after they were conducted during inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 May 2023
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. In addition, flexible or portable cords such as SO, STO, and similar types cannot be used for permanently installed wiring.
The vessel’s PA system is currently plugged into a power strip/extension cord. The length of the power strip’s power cable has been extended by splicing three longer wires into the existing cable. Provide hard wiring of the PA system into the vessel’s electrical distribution system to the satisfaction of the Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 21 September 2023
Resolution: Wiring for PA has been corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 May 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected.
There are daisy-chained extension cords/power strips underneath the console on the bridge. Reduce to one power strip maximum without any daisy chaining.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 21 September 2023
Resolution: All extension cords and power strips have been removed. A perminent outlet has been added.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel's FCC Safety Cert was expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 April 2023
Resolution: Owner showed proof of safety cert currency.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 November 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit does not contain equivalent contents of approval series 160.041 and contains expired medicines.
46 CFR 121.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2021
Resolved 25 May 2023
Resolution: While onboard for the 2023 CIC inspection, attending MIs confirmed that first aid kit is properly stocked with in-date supplies.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 November 2021
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Cable for head penetrating watertight bulkhead between lazerette and engine compartment is not sealed watertight.
46 CFR 171.114(a)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2021
Resolved 26 May 2023
Resolution: While onboard for the 2023 CIC inspection, attending MIs confimed that the noted cable penetration in the watertight bulkhead was been properly plugged and capped.
Fire Fighting › Fire Pumps › Pressure
Issued 12 November 2015
Resolved
Fire pump (Electric) does not obtain proper pressure to discharge from 01 fire hose. Repair and prove proper operation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2015
Resolved 8 December 2015
Resolution: Tested fire pump and system.
Construction/Loadline › Structures › Ventilators
Issued 12 November 2015
Resolved
Aft compartment gooseneck vent wasted and holed at the deck line. Repair/replace as original.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 November 2015
Resolved 8 December 2015
Resolution: Vent pipe repaired.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 November 2010
Resolved
Retro-reflective tape on child lifejackets is worn, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2011
Resolution: All of the children life jackets were replaced as new.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 19 November 2008
Resolved
Provide updated Fire Control Plan for vessel.
Due 20 December 2008
Resolved 30 December 2008
Resolution: Vessel owner placed fire control plan on vessel.
Lifesaving › Lifefloat › Painter
Issued 29 November 2007
Resolved
Lifefloat painters wasted (2). Replace with approved line 100ft each.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2007
Resolved 24 December 2007
Resolution: 24 Dec 07: Received a call from O/Op stating all above deficiencies were corrected.
Lifesaving › Lifefloat › Serviceable
Issued 29 November 2007
Resolved
4 lifefloats have holes/cuts on shell. Repair with approved kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2007
Resolved 24 December 2007
Resolution: 24 Dec 07: Received a call from O/Op stating all above deficiencies were corrected.
Construction/Loadline › Penetrations › Weld
Issued 29 November 2007
Resolved
Stbd access hatch has wastage around coaming. Repair and make weather tight. Raised Hatch located stbd side iwo bench seating.
Action required: 705 - Other - as specified
Due 29 December 2007
Resolved 24 December 2007
Resolution: 24 Dec 07: Received a call from O/Op stating all above deficiencies were corrected.
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 April 2006
Resolved
Crop and renew wasted frames below sewage tank in the lazarette, port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2006
Resolution: Wasted frames were cropped and renewed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 December 2005
Resolved
Replace grab lines on life ring located forward of wheel house.
Due 14 December 2005
Resolved 28 December 2005
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 15 December 2003
Resolved
Properly label both distribution panels IWO operating station.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 December 2003
Resolved 15 December 2003
Construction/Loadline › Hull › Hull Plating
Issued 15 December 2003
Resolved
C/R fwd peak side shell IWO stbd aft blkhd/deck from blkhd fwd approx. 3 feet (2 holes). Repairs to be completed during next drydock Apr 04. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 30 April 2004
Resolution: Cleared by MSO Hampton Roads during DD exam.
Construction/Loadline › Hull › Hull Plating
Issued 15 December 2003
Resolved
C/R lazarette side shell IWO port bay # 2 / deck. Repairs to be completed during next drydock Apr 04. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 30 April 2004
Resolution: Cleared by MSO Hampton Roads during DD exam.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 May 2003
Resolved
Post COI where visible to passengers (all pages).
Due 4 June 2003
Resolved 4 June 2003
Communications › Audible Communications › Bell
Issued 28 May 2003
Resolved
Install 11.8" bell.
Due 4 June 2003
Resolved 4 June 2003
Fire Fighting › Structural Fire Protection - General
Issued 28 May 2003
Resolved
Provide copy of "approved" or "examined" structural fire protection plans. Vessel restricted from carrying more than 150 passengers until completed.
Due 28 May 2003
Resolved 4 June 2003
Documentation › Logs/Records
Issued 11 December 2002
Resolved
PROVIDE TRAINING/BRIDGE LOG.
Action required: 705 - Other - as specified
Due 10 January 2003
Resolved 28 May 2003
Lifesaving › Buoyant Apparatus
Issued 11 December 2002
Resolved
ATTACH PAINTERS ON ALL LIFE FLOATS TO BODY OR EYE OF LIFE FLOAT, VICE GRAB LINES.
Action required: 705 - Other - as specified
Due 10 January 2003
Resolved 28 May 2003
Lifesaving
Issued 8 December 1999
Resolved
Provide new sea painter and grablines for lifefloats.
Condition: Unknown
Due 16 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 10 December 1997
Resolved
MAIN DECK HATCH TO ENGINE ROOM DOES NOT HAVE MEANS OF LATCHING IN OPEN POSITION.
Condition: Unknown
Due 24 December 1997
Resolved 23 December 1997
Lifesaving
Issued 14 December 1993
Resolved
PRIOR TO CARRYING PASSENGERS, CONDUCT A SATISFACTORY FIRE DRILL AND MAN OVERBOARD DRILL IN THE PRESENCE OF A USCG MARINE INSPECTOR. _x001C_ NOTE: DRILLS ARE TO BE CONDUCTED AFTER THE FIRE PUMP IS REPAIRED AND THE VESSEL'S RESCUE PLATFORM IS PLACED ON BOARD.
Condition: Unknown
Due 21 December 1993
Resolved 17 January 1994
Navigation
Issued 14 December 1993
Resolved
PRIOR TO CARRYING PASSENGERS, PLACE ON BOARD CURRENT COPIES OF THE TIDE ANDCURRENT TABLES AND COAST PILOT.
Condition: Unknown
Due 21 December 1993
Resolved 17 January 1994
Fire Fighting
Issued 14 December 1993
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO THE FIRE PUMP AND DEMONSTRATE ITS PROPER OPERATION TO AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 21 December 1993
Resolved 17 January 1994
Navigation
Issued 17 December 1991
Resolved
Provide current Light List and Notice to Mariners nlt 1 Feb91.
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Engineering
Issued 19 March 1991
Resolved
REMOVE OIL FROM BILGES AND PROVE PROPER OPERATION OF BILGE SYSTEM. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Engineering
Issued 19 March 1991
Resolved
PREPARE PRESSURE VESSEL (AIR RECEIVER) FOR INSPECTION BY COAST GUARD INSPECTOR.
Condition: Unknown
Due 19 March 1991
Resolved 19 March 1991
Engineering
Issued 7 March 1990
Resolved
PROVIDE MEANS TO HAND RELIEVE AIR TANK (PORT TANK IN ENGINE RM) RELIEF VALVE. IF A NEW VALVE IS FITTED, ENSURE IT IS SET FOR NO MORE THAN 125 PSI
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Navigation
Issued 9 March 1989
Resolved
DEMONSTRATE THAT 50 WATT, 12 VOLT LIGHT BULBS ARE APPROPRIATE FOR PERKO NAVIGATION LIGHTS. LIGHT FIXTURES SHALL COMPLY WITH NAVIGATION REGULATIONSACTUAL COMPLIANCE DATE FOR ABOVE REQUIREMENTS: 9APR89
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Lifesaving
Issued 9 March 1989
Resolved
PROVIDE TWO MORE 25-MAN LIFE FLOATS THAT ARE CG APPROVED.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Lifesaving
Issued 18 February 1988
Resolved
PROVIDE MARKING OF VESSEL NAME AND CAPACITY ON 4 LIFE FLOATS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Unknown
Issued 18 February 1988
Resolved
PROVIDE FOLLOWING PUBLICATIONS: CURRENT TIDE TABLES; RULES OF THE ROAD AND46CFR SUBCHAPTER "T" SMALL PASSENGER REGULATIONS.
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Lifesaving
Issued 18 February 1988
Resolved
RENEW WEAKLINKS TO 4 LIFE FLOATS. WEAKLINKS SHOULD EACH HAVE A PROPER BREAKING STRENGTH FOR 25 PERSONS
Condition: Unknown
Due 18 February 1988
Resolved 18 February 1988
Unknown
Issued 5 March 1987
Resolved
PROVIDE PROPER SERVICING AND RE-INSTALLATION OF FIXED CO2 FIRE EXTINGUISH- ING SYSTEM.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Unknown
Issued 5 March 1987
Resolved
REMOVE PAINT FROM GASKET AND EDGE OF WATERTIGHT DOOR TO ENGINE ROOM.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Lifesaving
Issued 14 March 1985
Resolved
REPLACE 6 ORANGE SMOKE FLARES.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Lifesaving
Issued 14 March 1985
Resolved
ATTACH WATERLIGHT TO RING BUOY.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985