Records from 2016 to 2026. Most recent: inspection, 27 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)78.3 ft × 25.6 ft × 10.2 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ.W. NOLAN CO. · ERIE, PA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCRISFIELD, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
20 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 20
27 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8338851
11 February 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8309312
20 November 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8281913
22 November 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8038434
8 February 2024
In-Service Inspection · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7862708
16 November 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7825704
21 September 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7798526
25 May 2023
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7688985
18 November 2022
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7596699
17 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7464027
3 March 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7405952
15 January 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7125160
3 December 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7105792
2 April 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6934431
21 November 2019
MTSA Verification · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6856241
14 November 2018
Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6581808
26 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6400053
16 November 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6320874
2 November 2016
Administrative Inspection · Security Plan Review - ASP · DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6034003
3 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5828841
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 16 November 2023
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Upper port life float's waterlight was inop.
46CFR180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 December 2023
Resolved 16 November 2023
Resolution: New waterlight battery was installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 November 2023
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. No drills have been logged for 6 months.
46CFR185.520 & 46CFR185.524
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 1 December 2023
Resolved 16 November 2023
Resolution: Drills were logged after they were conducted during inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 May 2023
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. In addition, flexible or portable cords such as SO, STO, and similar types cannot be used for permanently installed wiring.
The vessel’s PA system is currently plugged into a power strip/extension cord. The length of the power strip’s power cable has been extended by splicing three longer wires into the existing cable. Provide hard wiring of the PA system into the vessel’s electrical distribution system to the satisfaction of the Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 21 September 2023
Resolution: Wiring for PA has been corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 May 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected.
There are daisy-chained extension cords/power strips underneath the console on the bridge. Reduce to one power strip maximum without any daisy chaining.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 21 September 2023
Resolution: All extension cords and power strips have been removed. A perminent outlet has been added.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel's FCC Safety Cert was expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 April 2023
Resolution: Owner showed proof of safety cert currency.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 November 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit does not contain equivalent contents of approval series 160.041 and contains expired medicines.
46 CFR 121.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2021
Resolved 25 May 2023
Resolution: While onboard for the 2023 CIC inspection, attending MIs confirmed that first aid kit is properly stocked with in-date supplies.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 November 2021
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Cable for head penetrating watertight bulkhead between lazerette and engine compartment is not sealed watertight.
46 CFR 171.114(a)(2)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 December 2021
Resolved 26 May 2023
Resolution: While onboard for the 2023 CIC inspection, attending MIs confimed that the noted cable penetration in the watertight bulkhead was been properly plugged and capped.