MAURY USCG vessel records Sign in
← All vessels

CANNON TIDE

CANNON TIDE is a 1980 offshore supply vessel. The Coast Guard has recorded 36 inspections since 1982, most recently in March 1999, along with 34 deficiencies.

Records from 1982 to 1999. Most recent: inspection, 5 March 1999.

Built
1980
Last inspected
5 March 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8003163 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB6900
Flag
UNITED STATES
369355000 (licence lapsed)
Maury page id
psix-51435

Inspections, by type

…with no type recorded8
Years with a record 17 calendar years (1982–1999)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it182 - Regulatory (Subpart C or D), Net Ton
229 - Convention (Subpart B), Net Ton
267 - Regulatory (Subpart C or D), Gross Ton
764 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB6900MMSI 369355000 · expired · compulsorily equipped · granted 18 March 2004, cancelled 24 May 2014
WQZ8104MMSI not assigned · cancelled · compulsorily equipped · granted 10 March 1994, cancelled 23 March 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 36

5 March 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799044
3 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783280
16 October 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 775691
24 July 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 780096
24 July 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371941
20 September 1996 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 826222
20 May 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470687
27 November 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 883337
6 September 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184510
26 July 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439642
14 February 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 842623
18 February 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382704
20 January 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366782
27 December 1992 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445949
20 April 1992 Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 945250
19 April 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 74535
11 March 1992 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 947975
10 February 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1417439
27 December 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 950209
20 February 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 926209
20 February 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 929388
21 November 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1223579
16 July 1989 Hull Examination · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1338665
11 May 1989 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196336
10 May 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340479
14 March 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 900474
24 February 1988 COI Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 990684
4 May 1987 Re-Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332437
20 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315614
17 November 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021279
11 October 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322922
11 April 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991344
4 November 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295517
4 October 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302205
11 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281926
29 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272022

Deficiency record · 34

Lifesaving
Issued 20 May 1996 Resolved
REPLACE TWO SERVICE LINES FOR LINE THROWING APPARATUS.
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Engineering
Issued 20 May 1996 Resolved
REPLACE ALL INOPERATIVE INDICATING LIGHTS IN ALL ALARM INDICATING PANELS INENGINE ROOM AND WHEEL HOUSE.
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Engineering
Issued 20 May 1996 Resolved
PROVIDE GAGE GLASS PROTECTION AROUND ALL THOSE IN ENGINE ROOM THAT ARE MISSING THEM.
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Fire Fighting
Issued 20 May 1996 Resolved
REPAIR INOPERABLE FIREMAIN PRESSURE GAGE IN WHEELHOUSE
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Navigation
Issued 20 May 1996 Resolved
ADJUST MAGNETIC COMPASS (AT SEA) BY A QUALIFIED TECHNICIAN TO ENSURE THE DEGREE OF ERROR BETWEEN MAGNETIC COMPASS AND GYRO COMPASS IS MINIMAL, IE. LESS THAN 5 DEGREES._x001C_
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Engineering
Issued 20 May 1996 Resolved
REPAIR INOPERABLE TACHOMETERS ON PORT AND STARBOARD DIESEL GENERATORS.
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Navigation
Issued 26 July 1995 Resolved
CALIBRATE MAGNETIC COMPASS AND PROVIDE ON BOARD DEVIATION CARD.
Condition: Unknown
Due 26 July 1995
Resolved 26 July 1995
Construction/Loadline
Issued 20 April 1992 Resolved
Transverse frame # 70, on the starboard side of the engineroom fractured where it has been previously welded. Frame is 15 in X 4 in X 3/8 in._x001C_ REQUIREMENT: Vee & Weld transverse overhead frame # 70, starboard side approx 6ft outboard of centerline vent trunk side in the engineroom.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Construction/Loadline
Issued 20 April 1992 Resolved
Vee & Weld #3 overhead long, 10-1/2 in aft of frame 70, starboard side in the engineroom.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Construction/Loadline
Issued 20 April 1992 Resolved
Vee & Weld pipe stanchion at frame #70, starboard side at vent trunk side, in the engineroom.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Construction/Loadline
Issued 20 April 1992 Resolved
Crop & replace tripped bracket at pipe stanchion, frame #70 starboard side of the engineroom.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Construction/Loadline
Issued 20 April 1992 Resolved
Vee & Weld fracture at frame #72, starboard side at vent trunk side, in theengineroom.
Condition: Unknown
Due 30 April 1992
Resolved 23 April 1992
Navigation
Issued 20 February 1991 Resolved
Provide light bulb for ALDIS light.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Accommodation/Occupational Safety
Issued 20 February 1991 Resolved
Provide light covers for sink lights in all state rooms.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Deck/Cargo
Issued 20 February 1991 Resolved
Properly secure oxygene/acetylene bottles.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Fire Fighting
Issued 20 February 1991 Resolved
Renew fire pump packing and gland adjusting yoke.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Lifesaving
Issued 20 February 1991 Resolved
Repair or replace rescue boat.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Electrical
Issued 20 February 1991 Resolved
Properly block emergency batteries in their battery boxes.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Electrical
Issued 20 February 1991 Resolved
Drain standing water from emergency battery box.
Condition: Unknown
Due 20 February 1991
Resolved 20 February 1991
Navigation
Issued 20 February 1990 Resolved
PROVIDE CURRENT COMPASS DEVIATION CARD.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Engineering
Issued 20 February 1990 Resolved
CLEAN OIL FROM ENGINEROOM BILGES.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Deck/Cargo
Issued 20 February 1990 Resolved
CONDUCT 1.25 MAWP HYDROSTATIC TEST OF LIQUID MUD HOSES.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Fire Fighting
Issued 20 February 1990 Resolved
PROVE HYDROSTATIC TEST DATE OF PORTABLE CO2 EXTINGUISHERS.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Engineering
Issued 20 February 1990 Resolved
PROVIDE LUBE OIL TEMPERATURE AND JACKET WATER TEMPERATURE GAUGES FOR BOW THRUSTER ALARM PANEL.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Construction/Loadline
Issued 20 February 1990 Resolved
RENEW COMPRESSED AIR LINE FOR SEACHEST BLOWDOWN.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Electrical
Issued 20 February 1990 Resolved
REPLACE MISSING HAZARDOUS LOCATION LIGHT GLOBE IN PAINT LOCKER. LIGHT IS TO REMAIN TAGGED OUT AT SWITCH BOX UNTIL COMPLETE.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Electrical
Issued 20 February 1990 Resolved
REPAIR HOLES IN BOTH EMERGENCY BATTERY BOXES. (APPARENTLY DRILLED AS DRAINHOLES.)
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Fire Fighting
Issued 20 February 1990 Resolved
PROVIDE INSTRUCTIONS FOR OPERATION OF PAINT LOCKER FIXED CO2 SYSTEM.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Electrical
Issued 20 February 1990 Resolved
REPAIR OIL LEAK IN PORT GENERATOR ON INBOARD CENTERLINE HEAD.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990
Engineering
Issued 14 March 1989 Resolved
DEMONSTRATE PROPER OPERATION OF MAIN ENGINE REMOTE SHUTDOWNS IN PILOTHOUSE.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Accommodation/Occupational Safety
Issued 14 March 1989 Resolved
DEMONSTRATE PROPER OPERATION OF RED FOX MARINE SANITATION DEVICE.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Engineering
Issued 14 March 1989 Resolved
REPAIR & DEMONSTRATE PROPER OPERATION OF LUBE OIL PRESSURE GUAGES, ENGINE TACHOMETERS, AND ENGINE MONITOR/INDICATORS.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Engineering
Issued 11 April 1986 Resolved
PROVIDE TEST EQUIPMENT AND TEST PROCEDURES FOR ENGINE ROOM ALARM SYSTEM AS PER NVIC 1-78.
Condition: Unknown
Due 11 April 1986
Resolved 11 April 1986
Navigation
Issued 4 October 1985 Resolved
PROVE PROPER OPERATION OF STEERING SYSTEM IN THE FOLLOW-UP MODE.
Condition: Unknown
Due 4 October 1985
Resolved 4 October 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.