Records from 1980 to 2000. Most recent: inspection, 27 June 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 14 July 1999
Resolved
Maintain crew training log and properly record drills for crew. 185.420
Condition: Unknown
Due 16 August 1999
Resolved 23 August 1999
Electrical
Issued 14 July 1999
Resolved
Remove 220v knife switch receptical located in freezer box.
Condition: Unknown
Due 16 August 1999
Resolved 23 August 1999
Electrical
Issued 14 July 1999
Resolved
Remove dead ended wires in way of engine room port fwd bulk passageway.
Condition: Unknown
Due 16 August 1999
Resolved 23 August 1999
Engineering
Issued 14 July 1999
Resolved
Install sewage tank level indicator
Condition: Unknown
Due 16 August 1999
Resolved 23 August 1999
Electrical
Issued 14 July 1999
Resolved
Install drip plate and proper lable new 220v panel in engine room
Condition: Unknown
Due 16 August 1999
Resolved 23 August 1999
Construction/Loadline
Issued 14 July 1999
Resolved
Install and seal bulkhead fitting in way of engine room fwd port bulkhead
Condition: Unknown
Due 16 August 1999
Resolved 23 August 1999
Navigation
Issued 7 November 1996
Resolved
PROVE TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR THEPROPER OPERATION OF ALL MACHINERY INCLUDING: FIRE PUMPS, BILGE PUMPS, GENERATOR, BILGE PIPING, FIRE HOSE AND NOZZLE, STEERING SYSTEM, AND VENTILATION SYSTEM IN ACCORDANCE WITH 46 CFR 176.802, 176.804, 176.810.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
RENEW DEFECTIVE RETRO-REFLECTIVE MATERIAL ON ALL ADULT AND CHILDREN LIFE JACKETS. EACH LIFE JACKET MUST BE MARKED WITH TYPE I RETRO-REFLECTIVE MATERIAL APPROVED UNDER 46 CFR 164.018 IN ACCORDANCE WITH _x001C_ 46 CFR 185.604(h).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
PROVIDE AND INSTALL A LIFELINE AND FLOATING WATERLIGHT TO VESSELS RING LIFEBUOYS IN ACCORDANCE WITH 46 CFR 180.70.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 7 November 1996
Resolved
REPAIR/RENEW DEFECTIVE FIRE HYDRANT VALVE LOCATED ON STARBOARD SIDE MAIN DECK. SEE 46 CFR 181.310.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 7 November 1996
Resolved
RENEW EXISTING FIRE HOSES WITH FIRE HOSES THAT CONFORM TO UNDERWRITERS LABORATORY(UL) STANDARD 19 OR IS LISTED AND LABELED BY AN INDEPENDENT LABORATORY RECOGNIZED BY THE COAST GUARD AS BEING EQUIVALENT IN PERFORMANCE. SEE 46 CFR 181.320
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 7 November 1996
Resolved
REPAIR/RENEW COMPROMISED WATERTIGHT TRANSVERSE BULKHEADS. PROVE WATERTIGHTNESS OF EACH SUBDIVISION BULKHEAD TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOTR IN ACCORDANCE WITH 46 CFR 179.21(b), 171.070 AND 179.320.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 7 November 1996
Resolved
INSTALL ANTI-CHAFFING AND SECURING CLAMPS TO GALLEY MAIN ELECTRICAL DISTRUBUTION PANEL. SEE 46 CFR 183.200.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 7 November 1996
Resolved
INSTALL METAL SUPPORTS FOR ALL ELECTRICAL CABLE AND WIRE INSTALLATIONS IN ACCORDANCE WITH 46 CFR 183.340 TO THE SATISFACTION OF THE ATTENDING US. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 7 November 1996
Resolved
REPAIR/RENEW SECTION OF DAMAGED/HOLED SIDESHELL PLATING PORT SIDE IN WAY OFCHINE JUST AFT OF THE COLLISION BULKHEAD IN ACCORDANCE WITH ACCEPTED INDUSTRY STANDARDS, NVIC 11-80 AND NVIC 7-68. PRIOR TO REPAIRS/RENEWAL PROVIDE A WRITTEN PROPOSAL TO THE OCMI FOR APPROVAL.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 7 November 1996
Resolved
REMOVE DEAD ENDED ELECTRICAL CABLES AND WIRING FROM VESSEL THAT ARE DEDICATED TO A SPECIFIC VESSEL SYSTEM. SEE 46 CFR 183.200.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 7 November 1996
Resolved
PROVIDE AND INSTALL CG APPROVED PORTABLE FIRE EXTINGUISHERS AND BRACKETS_x001C_ THROUGHOUT THE VESSEL IN ACCORDANCE WITH 46 CFR 151.520 AND TABLE 181.500(a) TO THE SATISFACTION OF THE ATTENDING U.S. COAST GAURD MARINE INSPECTOR.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Engineering
Issued 7 November 1996
Resolved
PROPERLY MARK EMERGENCY FUEL SHUTOFF VALVES IN ACCORDANCE WITH 46 CFR 185.608.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Engineering
Issued 7 November 1996
Resolved
REMOVE PLASTIC GASOLINE TANKS FROM VESSEL AND RENEW WITH METAL GASOLINE CANS. SEE 46 CFR 182.15-25(A)(8).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Documentation
Issued 7 November 1996
Resolved
PROVIDE PROOF OF VALID STATE REGISTRATION FOR ALL SKIFFS. SEE 33 CFR 173.15.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Documentation
Issued 7 November 1996
Resolved
REMOVE THE TWO ADDITIONAL SKIFFS ABOARD THE VESSEL SO THAT THE NUMBER OF SKIFFS CARRIED COMPLIES WITH THE REQUIREMENTS OF THE VESSEL'S STABILITY LETTER. SEE 46 CFR 185.20-5(a).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996
Resolved
PROPERLY REPAIR/RENEW AS ORIGINAL THE DETERIORATED GASKETS ON THE GENERATORROOM AND ENGINEROOM VENTS. SEE 46 CFR 182.20-50.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996
Resolved
PROVE THE PROPER OPERATION OF THE GENERATOR ROOM VENTILATION COVERS TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR. SEE 46 CFR 177.20-1.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996
Resolved
PROVIDE AND INSTALL A MEANS OF INDICATING WHEN THE TYPE III MARINE SANITATION DEVICE IS MORE THAN 3/4 FULL BY VOLUME IN ACCORDANCE WITH 33 CFR159.83 TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996
Resolved
INSTALL A 30X30 MESH SCREEN TO TYPE III MARINE SANITATION DEVICE ATMOSPHEREVENT. SEE 33 CFR 159.95(a)(2).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL SECURING DEVICES AND CAPTIVE CHAINS FOR THE HATCH LOCATED ON THE FOREPEAK. SEE 46 CFR 179.360(B).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 7 November 1996
Resolved
RENEW/REPAIR THE WATERTIGHT FOREPEAK HATCH. SEE 46 CFR 179.360(A).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 7 November 1996
Resolved
PROPERLY INSTALL GASKETS ON THE WATERTIGHT GENERATOR ROOM AND ENGINEROOM HATCHES. SEE 46 CFR 179.360(A).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL SECURING DEVICES AND CAPTIVE CHAINS FOR THE HATCH LOCATED ON THE AFTERPEAK. SEE 46 CFR 179.360(B).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 7 November 1996
Resolved
PROPERLY MARK THE COLLISION BULKHEAD BILGE SUCTION VALVE.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL VALVE HANDLES ON THE BILGE MANIFOLD. SEE 46 CFR 182.510(C).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL A MEANS TO LOCK THE MARINE SANITATION DEVICE OVERBOARD VALVE WHILE IN U. S. TERRITORAL WATERS.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Engineering
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL FUEL SHUTOFF VALVE AT THE ENGINE END OF THE FUEL LINE FOR THE PORT GENERATOR. SEE 46 CFR 182.455(B)(4).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL ELECTRICAL COVERS IN ALL IDENTIFIED AREAS. SEE 46 CFR 183.20O(B).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 7 November 1996
Resolved
REMOVE ALL WIRE NUTS FROM THE ELECTRICAL CONTROL PANEL IN THE GENERATOR SPACE AND REPLACE THEM WITH PRESSURE TYPE CONNECTORS MEETING UL STANDARD 486A IN ACCORDANCE WITH 46 CFR 183.340(I).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL MISSING VALVE HANDLE ON FIRE MAIN PIPING IN THE GENERATOR SPACE. SEE 46 CFR 181.310(A).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL BILGE HIGH LEVEL ALARMS FOR THE ENGINEROOM ANDSTEERING GEAR ROOM IN ACCORDANCE WITH 46 CFR 182.530.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL METAL SHUTOFF VALVES ON THE PVC PIPING PENETRATATING THE WATERTIGHT BULKHEADS IN ACCORDANCE WITH 46 CFR 182.720(D)(1)(II).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 7 November 1996
Resolved
PROVE THE PROPER OPERATION OF THE BILGE PUMP AND BILGE PIPING SYSTEM TO THESATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. SEE 46 CFR 182.500.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Engineering
Issued 7 November 1996
Resolved
PROPERLY ATTACH THE STARBOARD MAIN ENGINE EXHAUST BRACKETS TO THEIR SUPPORTS. SEE 46 CFR 177.35-15.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
INSTALL PROPER SIZE APPROVED FLOAT FREE LINK TO LIFE FLOATS IN ACCORDANCE WITH 46 CFR 180.137(b)(2).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
PROVIDE, INSTALL AND MARK PADDLES TO EACH LIFE FLOAT IN ACCORDANCE WITH _x001C_ 46 CFR 180.175(e)(2) AND 185.604(g).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
REPAIR DEFECTIVE/DAMAGED 25 MAN LIFE FLOAT AS ORIGINAL IN ACCORDANCE WITH 46 CFR 160.027(a)(2) OR RENEW WITH ANOTHER CG APPROVED LIFE FLOAT.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
CLEARLY MARK LIFE FLOATS IN ACCORDANCE WITH 46 CFR 185.604.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
PROVIDE AND INSTALL CG APPROVED FLOATING WATERLIGHT TO EACH LIFE FLOAT IN ACCORDANCE WITH 46 CFR 180.175(c) AND 180.175(e)(4).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Documentation
Issued 7 November 1996
Resolved
PROVIDE AND POST ON BOARD VESSEL A VALID FCC SAFETY RADIO TELEPHONE CERTIFICATE IN ACCORDANCE WITH 47 CFR 80.15.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Documentation
Issued 7 November 1996
Resolved
PRVIDE AND POST ON BOARD VESSEL A WASTE MANAGEMENT PLAN AND PLACARD IN _x001C_ ACCORDANCE WITH 33 CFR 151.57 AND 151.59.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Navigation
Issued 7 November 1996
Resolved
REPAIR OR RENEW DAMAGED/DEFECTIVE STERN NAVIGATION LIGHT IN ACCORDANCE WITH46 CFR 183.420.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
RENEW DEFECTIVE SEA PAINTER TO LIFE FLOATS IN ACCORDANCE WITH 46 CFR 180.175.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 7 November 1996
Resolved
INSTALL AND PROVE OPERATION OF EMERGENCY LIGHTING SYSTEM IN ACCORDANCE WITH46 CFR 183.432 TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINEINSPECTOR.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 7 November 1996
Resolved
PROVIDE AND LOCATE ON BOARD VESSEL AT LEAST TWO OPERABLE PORTABLE BATTERY LIGHTS IN ACCORDANCE WITH 46 CFR 183.430.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 7 November 1996
Resolved
PROVIDE AND INSTALL PROTECTIVE LIGHT COVERS TO ALL LIGHTING FIXTURES THROUGHOUT VESSEL IN ACCORDANCE WITH 46 CFR 183.200 TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
PROVIDE ON BOARD VESSEL ADEQUATE AND ACCESSIBLE STORAGE CONTAINERS FOR LIFEJACKETS IN ACCORDANCE WITH 46 CFR 180.78 AND CLEARLY MARK CONTAINERS IN ACCORDANCE WITH 46 CFR 185.604(f).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
PROVIDE,INSTALL AND MARK SEPERATE STORAGE CONTAINER FOR CHILDREN LIFE JACKETS IN ACCORDANCE WITH 46 CFR 180.789(a)(5).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
PROVIDE ON BOARD VESSEL AN ADDITIONAL FOURTEEN COAST GUARD APPROVED TYPE I ADULT SIZE LIFE JACKETS IN ACCORDANCE WITH 46 CFR 180.71.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
PROVIDE ON BOARD VESSEL TWO ADDITIONAL COAST GUARD APPROVED TYPE I CHILD LIFE JACKETS IN ACCORDANCE WITH 46 CFR 180.71.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Fire Fighting
Issued 7 November 1996
Resolved
MOUNT FIRE AXE IN AN ACCESSIBLE LOCATION IN ACCORDANCE WITH 46 CFR 181.600.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Navigation
Issued 7 November 1996
Resolved
PROVE THE PROPER OPERATION OF ALL NAVIGATION LIGHTS, COMPASS LIGHT, AND RADIO EQUIPMENT TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR. SEE 46 CFR 184.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996
Resolved
PROPERLY SANATIZE THE GALLEY AND PASSENGER SPACES IN ACCORDANCE WITH 46 CFR176.818.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Unknown
Issued 7 November 1996
Resolved
PROVE THE PROPER OPERATION OF THE SKIFF LAUNCHING APPLIANCES TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR. SEE 46 CFR 185.704.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Lifesaving
Issued 7 November 1996
Resolved
PROPERLY POST "NO SMOKING" SIGNS IN THE NEAR VICINITY OF THE GASOLINE STORAGE AREA IN ACCORDANCE WITH 46 CFR 185.20-20.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL JUNCTION BOX IN THE STEERING COMPARTMENT OVERHEAD IN WAY OF WIRE SPLICE IN ACCORDANCE WITH 46 CFR 183.340(g).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Unknown
Issued 7 November 1996
Resolved
PROVIDE ON BOARD VESSEL THE CORROSION RESISTANT TAGS FOR THE SKIFF LAUNCHING APPLIANCES IN ACCORDANCE WITH 46 CFR 185.704(c).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Electrical
Issued 7 November 1996
Resolved
PROVIDE AND INSTALL THE PROPER COVERS FOR THE 110 VOLT OUTLET LOCATED IN THE PASSENGER HEAD IN ACCORDANCE WITH 46 CFR 183.210(a)(2).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996
Resolved
PROPERLY MARK ALL EMERGENCY ESCAPE EXITS IN ACCORDANCE WITH 46 CFR 185.606.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Navigation
Issued 7 November 1996
Resolved
PROVIDE ON BOARD VESSEL UPDATED NAUTICAL PUBLICATIONS AND CHARTS. SEE 46 CFR 184.420.
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Accommodation/Occupational Safety
Issued 7 November 1996
Resolved
PROVIDE AND PROPERLY INSTALL QUICK OPENING DEVICES ON BOTH SIDES OF ALL EMERGENCY ESCAPE EXITS IN ACCORDANCE WITH 46 CFR 177.500(h).
Condition: Unknown
Due 7 November 1996
Resolved 7 November 1996
Construction/Loadline
Issued 10 April 1990
Resolved
MAKE PERMANENT REPAIRS TO FIVE INCH CRACK AND 1/4" HOLE IN STBD SIDE SHELL AROUND STBD GENERATOR EXHAUST.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Engineering
Issued 16 March 1990
Resolved
REPAIR AND DEMONSTRATE OPERATION OF MAIN ENGINE STARTS AND STOPS LOCATED IN THE PILOT HOUSE.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Navigation
Issued 20 March 1989
Resolved
PROVIDE A COAST GUARD APPROVED EPIRB. 46 CFR 180.40. COMPLIANCE DATE IS: 31MAR89
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Construction/Loadline
Issued 20 March 1989
Resolved
REPAIR OR REPLACE THE ESCAPE HATCH LOCATED IN THE LAZERETTE. 46 CFR 177.15.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Lifesaving
Issued 20 March 1989
Resolved
PROVIDE FLOAT LIGHTS FOR EACH LIFE FLOAT ABOARD. 46 CFR 180.15-1(B). COMPLIANCE DATE IS: 31MAR89
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Navigation
Issued 20 March 1989
Resolved
MAKE OPERABLE THE DRAKE SINGLE SIDE BAND RADIO. COMPLIANCE DATE IS: 31MAR89
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Electrical
Issued 18 April 1988
Resolved
INSTALL COVER FOR ELECTRICAL JUNCTION BOX ON THE WHEELHOUSE UNDER THE CONSOLE.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Navigation
Issued 18 April 1988
Resolved
REPAIR ANCHOR LIGHTS.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Electrical
Issued 18 April 1988
Resolved
INSTALL CORRECT BATTERY TRAY OR MOUNTING WITH REQUIRED CORRECT ENCLOSURE ORSHIELDING LOCATED ON WHEELHOUSE UNDER THE CONSOLE. INSTALL SHIELDING FOR BATTERY TRAY LOCATED IN MACHINERY SPACE.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Electrical
Issued 18 April 1988
Resolved
INSTALL COVER OR REPLACE LOW PRESSURE SWITCH FOR A.C. UNIT LOCATED IN GENERATOR ROOM.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Fire Fighting
Issued 15 April 1987
Resolved
CONDUCT ANNUAL SERVICE FOR PORTABLE FIRE EXTINQUISHERS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Fire Fighting
Issued 15 April 1987
Resolved
PROVIDE ON BOARD THE VESSEL A SUITABLE HAND FIRE PUMP.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Electrical
Issued 15 April 1987
Resolved
DEMONSTRATE PROPER OPERATION OF GENERATOR OVERSPEED TRIPS TO THE SATIS- FACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Lifesaving
Issued 15 April 1987
Resolved
CONDUCT ANNUAL SERVICING OF THE HYDROSTATIC RELEASE FOR THE INFLATABLE LIFE RAFT.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Construction/Loadline
Issued 15 April 1987
Resolved
RENEW MISSING GASKET FOR THE WATERTIGHT DOOR BETWEEN THE GALLEY AND PASSAGEWAY.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Accommodation/Occupational Safety
Issued 24 April 1986
Resolved
REMOVE COMBUSTIBLE GALLEY VENT AND INSTALL AN EXHAUST VENT OF EITHER 18 GAUGE STEEL OR 20 GAUGE STAINLESS STEEL. COMPLIANCE DATE IS 24APR86.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Engineering
Issued 24 April 1986
Resolved
REPAIR OR REPLACE EXHAUST LAGGING TO ALL THREE MAIN ENGINES. COMPLIANCE DATE IS 24APR86.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Engineering
Issued 24 April 1986
Resolved
REMOUNT AIR SUPPLY LINE TO PNEDMATIC CONTROL IN ENGINE ROOM.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Electrical
Issued 24 April 1986
Resolved
REMOVE ALL LOOSE WIRING IN ENGINE ROOM. COMPLIANCE DATE IS 24APR86.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Electrical
Issued 24 April 1986
Resolved
INSTALL BLANK COVERS IN ELECTRICAL DISTRIBUTION PANEL IN AUXILLARY MACHINERY SPACE WHERE CIRCUIT BREAKERS ARE MISSING. COMPLIANCE DATE IS 24APR86.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Documentation
Issued 29 April 1985
Resolved
PROVIDE PROOF OF APPLICATION TO THE FCC FOR A SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 29 April 1985
Resolved 29 April 1985
Documentation
Issued 29 April 1985
Resolved
PROVIDE DOCUMENTATION WITH THE NEW NAME OF THE VESSEL OR REPAINT VESSEL MARKINGS TO C.M. 1.
Condition: Unknown
Due 29 April 1985
Resolved 29 April 1985