MAURY USCG vessel records Sign in
← All vessels

INGER

INGER is a 1945 freight ship. The Coast Guard has recorded 71 inspections since 1982, most recently in October 1995, along with 62 deficiencies.

Records from 1982 to 1995. Most recent: inspection, 17 October 1995.

Built
1945
Last inspected
17 October 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5161134 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
INDIA
—
Maury page id
psix-51452

Inspections, by type

…with no type recorded34
Years with a record 14 calendar years (1982–1995)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10207 - Regulatory (Subpart C or D), Net Ton
23977 - Dead Weight, Ton
14192 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KCSAMMSI not assigned · expired · compulsorily equipped · granted 12 February 1991, cancelled 12 February 1996
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 71

17 October 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1188606
16 October 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1184673
10 April 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846377
15 March 1995 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1139520
20 January 1995 Administrative
Administrative · Commandant (CG-CVC) · Activity 1178545
29 December 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1160948
30 November 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1179003
3 November 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1453077
15 August 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 369304
10 August 1994 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1174675
18 June 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 37822
6 May 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 859857
4 May 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1170133
29 April 1994 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1168909
18 April 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 647177
15 April 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1167663
15 March 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 211933
6 December 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359672
17 November 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141142
19 October 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1429813
28 May 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 217054
23 May 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 453949
18 March 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463760
8 February 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 41983
19 November 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1136255
31 October 1992 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942017
27 October 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1262604
21 October 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 97696
21 October 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 179173
5 August 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 499661
8 June 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 351193
3 April 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1256261
14 November 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 75594
24 September 1991 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1245378
26 March 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 511129
18 December 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1217179
25 October 1990 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 916359
15 October 1990 MARPOL Annex II Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1234072
25 April 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1234733
25 January 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 905822
16 January 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 914449
29 November 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 924052
20 November 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 909743
28 September 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002970
30 August 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 472486
28 December 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1042153
21 October 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 888420
3 May 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 323039
31 December 1987 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1321272
18 December 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006200
23 November 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334123
22 October 1987 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332630
18 July 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 494573
17 November 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 312745
29 September 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1003909
8 September 1986 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1005898
15 August 1986 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1000372
23 May 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1298210
9 May 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 523745
12 September 1985 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 991365
9 August 1985 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993361
14 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 538912
18 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 972780
26 November 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 978579
21 November 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1284495
28 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975408
20 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975166
24 July 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 297111
28 December 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1278876
8 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277867
3 May 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 968772

Deficiency record · 62

Construction/Loadline
Issued 15 March 1995 Resolved
VESSEL MUST ENTER DRYDOCK NO LATER THAN 31JUL95.
Condition: Unknown
Due 31 July 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 15 March 1995 Resolved
PROPERLY REPAIR ALL WASTED VERTICAL AND LONGITUDINAL STIFFENERS AROUND_x001C_ CARGO HOLD HATCH COAMINGS.
Condition: Unknown
Due 31 July 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 3 November 1994 Resolved
Replace wasted horizontal plate above bulwark at stem.
Condition: Unknown
Due 2 December 1994
Resolved 1 December 1994
Electrical
Issued 3 November 1994 Resolved
Remove dead end wire in void space outside laundry room.
Condition: Unknown
Due 2 December 1994
Resolved 1 December 1994
Construction/Loadline
Issued 3 November 1994 Resolved
Properly repair wasted vertical and longitudnal stiffeners around cargo hold hatches.
Condition: Unknown
Due 3 November 1994
Resolved 3 November 1994
Accommodation/Occupational Safety
Issued 3 November 1994 Resolved
Replace wasted rails and ladder rungs around deck house and foc'sle
Condition: Unknown
Due 2 December 1994
Resolved 1 December 1994
Construction/Loadline
Issued 3 November 1994 Resolved
Recondition and make weather tight all weather tight doors from 01 level up.
Condition: Unknown
Due 2 December 1994
Resolved 1 December 1994
Lifesaving
Issued 29 April 1994 Resolved
RE-SHIP AND RE-OUTFIT PORT LIFE BOAT WITH PROVISIONS ONCE PERMANMENT REPAIRS ARE MADE.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Lifesaving
Issued 29 April 1994 Resolved
PROVIDE, INSTALL AND MAINTAIN TWO (2) ADDITIONAL 25 LIFERAFTS ON PORT SIDE UNTIL REPAIRS CAN BE MADE TO PORT LIFE BOAT.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Lifesaving
Issued 29 April 1994 Resolved
MAKE AND PROVE PERMANMENT REPAIRS TO PORT LIFE BOAT IN-WAY OF STBD BOW AREA
Condition: Unknown
Due 10 May 1994
Resolved 11 May 1994
Construction/Loadline
Issued 6 December 1993 Resolved
MAKE PERMANENT REPAIRS TO BULKHEAD(FWD TRANVERSE) IN WAY OF #1 F/O TRANSFERPUMP AND PROVIDE NDT RESULTS ,UPON RETURN TO US PORT FOR BADLY PITTED AREAS(FWD OF THE TRANSFER PUMP).
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Construction/Loadline
Issued 19 October 1993 Resolved
PROVE PROPER OPERATION OF PORT MAIN BALLAST ELECTRIC PUMP.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Navigation
Issued 19 October 1993 Resolved
REPAIR RUDDER OSCILLATION CAUSED BY PORT STEERING PUMP.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Engineering
Issued 19 October 1993 Resolved
PROVIDE FIRE AND WATERSIDE INSPECTION OF BOTH BOILERS.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Construction/Loadline
Issued 19 October 1993 Resolved
MAKE DOOR BETWEEN PUMPROOM AND ENGINEROOM WATERTIGHT.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Construction/Loadline
Issued 19 October 1993 Resolved
MAKE TRANSVERSE BULKHEAD WATERTIGHT BETWEEN ENGINE ROOM AND FIRE ROOM IN WAY OF SEWAGE DRAIN LINES (3).
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Electrical
Issued 19 October 1993 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 December 1993
Resolved 19 October 1993
Navigation
Issued 19 October 1993 Resolved
PROVE PROPER OPERATION OF HAND EMERGENCY STEERING AND POST INSTRUCTION FOR SAME.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Lifesaving
Issued 19 October 1993 Resolved
CONDUCT WEIGHT TEST OF STARBOARD LIFE BOAT.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Construction/Loadline
Issued 19 October 1993 Resolved
MAKE PERMANENT REPAIRS TO FUEL OIL LEAK IN FORWARD PUMPROOM, FORWARD TRANSVERSE BULKHEAD ON STARBOARD SIDE. AREA IS TO BE INSPECTED DAILY AND IF ANY APPRECIABLE AMOUNT OF OIL IS NOTED THE NEAREST OCMI IS TO BE NOTIFIED IMMEDIATELY.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Engineering
Issued 19 October 1993 Resolved
REMOVE BOILER MOUNTING STUDS ON BOTH BOILERS FOR EXAMINATION.
Condition: Unknown
Due 12 September 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 October 1993 Resolved
REPAIR OR RENEW #1 SHIPS SERVICE GENERATOR KILOWATT METER.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Lifesaving
Issued 31 October 1992 Resolved
SERVICE ALL LIFERAFTS AT A USCG APPROVED SERVICING FACILITY AT FIRST PORT OF CALL BUT NO LATER THAN 30NOV92.
Condition: Unknown
Due 31 October 1992
Resolved 31 October 1992
Construction/Loadline
Issued 31 October 1992 Resolved
REINFORCE CENTER PORTION OF DECK IN PORT LAUNDRY ROOM._x001C_
Condition: Unknown
Due 31 October 1992
Resolved 31 October 1992
Construction/Loadline
Issued 31 October 1992 Resolved
CROP AND RENEW THE FOLLOWING TO GOOD METAL; ALL TANK TOP STIFFENERS FROM AFTMOST BULKHEAD IN #4P DOUBLE BOTTOM FORWARD, INCLUDING CONNECTION BRACKETS; ALL LONGITUDINALS GIRDERS IN WAY OF AFT BULKHEAD IN #4P DOUBLE BOTTOM. _x001C_
Condition: Unknown
Due 31 October 1992
Resolved 31 October 1992
Construction/Loadline
Issued 31 October 1992 Resolved
MAKE PERMANENT REPAIRS TO FORWARD PUMPROOM DECK GRATINGS IN WAY OF AFT BULKHEAD._x001C_
Condition: Unknown
Due 31 October 1992
Resolved 31 October 1992
Engineering
Issued 24 September 1991 Resolved
HYDROSTATICALLY TEST THE MAIN STEAM PIPING BOTH BOILERS AS REQUIRED BY 46_x001C_CFR 61.15-5.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Engineering
Issued 24 September 1991 Resolved
OPEN ALL MOUNTS AND MAIN STEAM VALVES FOR INSPECTION AS REQUIRED BY _x001C_ 46 CFR 61.05-15.
Condition: Unknown
Due 24 September 1991
Resolved 24 September 1991
Electrical
Issued 25 October 1990 Resolved
INSTALL AND OPERATE OR PRODUCE DOCUMENTATION FOR COAST GUARD APPROVED DEVIATION FROM APPLICABLE REGULATIONS, A LOW LUBE OIL PRESSURE AUDIBLE ALARM AS REQUIRED IN "OLD" SUBCHAPTER J 112.50-1(A) (JULY 1, 1964).
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Lifesaving
Issued 25 October 1990 Resolved
REPAIR AND RETEST SUSPENSION, FLOTATION, IN WATER OPERATIONS AND RELEASING GEAR ON STARBOARD LIFEBOAT. WHILE LIFEBOAT IS BEING REPAIRED, CG APPROVED LIFERAFTS OF SATISFACTORY CAPACITY TO MEET THE VESSEL'S TOTAL PERSONS ALLOWED SHALL BE CARRIED & INSTALLED TO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Engineering
Issued 25 April 1990 Resolved
REPLACE HIGH INJECTION NON-METALIC FLEX COUPLING AND MAIN CONDENSER OVER BOARD NON-METALIC COUPLING OR PROVIDE SATISFACTORY DOCUMENTATION AS TO DATEOF MANUFACTURE.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Construction/Loadline
Issued 25 April 1990 Resolved
EFFECT PERM REPAIRS TO WEB FRAMES IN AFT PUMP ROOM PORT SIDE. REPAIRS ARE IN WAY OF DOUBLE BOTTOM FUEL TANK. TANK TO BE GAS FREE BRFORE STARTING HOT WORK.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Construction/Loadline
Issued 25 April 1990 Resolved
CROP AND RENEW 3 LOWEST6 LONG BRACKETS IN AFT PORT COFFERDAM. AFT BULKHEADIS COMMON WITH DOUBLE BOTTOM FUEL TANK. TANK TO BE GAS FREE BEFORE STARTING HOT WORK.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Lifesaving
Issued 25 April 1990 Resolved
CONDUCT WEIGHT TEST OF PORT AND STBD LIFEBOATS IN PRESENCE OF USCG INSPECTOR.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Construction/Loadline
Issued 29 November 1989 Resolved
MAKE VESSEL AVAILABLE FOR INSPECTION OF THE INTERIOR HULL STRUCTURE IN A FULL LOAD CONDITION PRIOR TO 31JAN90 FOR CONSIDERATION TOWARDS AN EARLY DRYDOCKING.
Condition: Unknown
Due 29 November 1989
Resolved 29 November 1989
Construction/Loadline
Issued 20 November 1989 Resolved
NO LATER THAN NEXT DRYDOCK MAKE PERMANENT REPAIRS TO DOUBLED OVER TANKTOP OF FEEDWATER TANK STBD SIDE SHAFT ALLEY. TANK TOP SHALL BE TAKEN BACK TO SOUND METAL AND RENEWED PER ORIGINAL TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 20 November 1989
Resolved 20 November 1989
Construction/Loadline
Issued 20 November 1989 Resolved
CROP AND RENEW 3' SECTION OF 1ST DEEPWEB TRANSVERSE FRAME FWD OF BULKHEAD 145 BELOW 2ND DECK IN BOW. VEE OUT AND WELD 1" CRACK IN PORT SIDE HULL IN WAY OF ABOVE RENEWED FRAME, WELD SHALL BE FROM BOTH SIDES OF PLATE, FULL PENETRATION.
Condition: Unknown
Due 20 November 1989
Resolved 20 November 1989
Electrical
Issued 28 September 1989 Resolved
PROVE PROPER OPERATION OF THE LOW LUBE OIL TRIP AND HIGH COOLING WATER TEMPERATURE ALARM FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Construction/Loadline
Issued 28 September 1989 Resolved
CROP AND RENEW PORT SIDE SHELL PLATING AND INTERNALS, FRAME 36 (3 CEMENT BOX PATCHES) AT THE NEXT SCHEDULED DRYDOCKING. THE MASTER IS TO NOTIFY THENEAREST [name withheld] OCCUR IN THE TEMPORARY CEMENT BOX PATCHES.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Construction/Loadline
Issued 21 October 1988 Resolved
MAKE REPAIRS TO WASTED DECK IN FAN/AIR-WASH ROOM AND CONNECTING WING DECKS 46USC3313 (A)
Condition: Unknown
Due 21 October 1988
Resolved 21 October 1988
Accommodation/Occupational Safety
Issued 21 October 1988 Resolved
CONDUCT OPERATIONAL TEST OF REMOTE VENTILATION SHUT DOWN FROM BRIDGE 46CFR111.103
Condition: Unknown
Due 21 October 1988
Resolved 21 October 1988
Lifesaving
Issued 21 October 1988 Resolved
INSTALL NEW SMOKE SIGNAL MOUNTING BRACKETS ON PORT AND STBD BRIDGE WINGS 46CFR94.43-10 (C)
Condition: Unknown
Due 21 October 1988
Resolved 21 October 1988
Navigation
Issued 3 May 1988 Resolved
33 CFR 164.33(A)(3)(II) THE VESSEL DID NOT HAVE AN EDITION OF THE PACIFIC TIDAL CURRENT TABLE. 33 USC 1223
Condition: Unknown
Due 3 May 1988
Resolved 3 May 1988
Lifesaving
Issued 22 October 1987 Resolved
PROVIDE 5 COAST GUARD APPROVED EXPOSURE SUITS, PROPERLY MARKED AND EQUIPPEDBRINGING TOTAL TO 44. UNTIL PROPER NUMBER IS ON BOARD VESSEL IS RESTRICTED TO CARRYING TOTAL OF 32 PERSONS ON BOARD.
Condition: Unknown
Due 22 October 1987
Resolved 22 October 1987
Fire Fighting
Issued 22 October 1987 Resolved
REFIT THE REMOVED WTD BETWEEN THE ENGINEROOM AND THE BOILEROOM OR PROVIDE EVIDENCE OF COAST GUARD APPROVAL FOR ITS REMOVAL.
Condition: Unknown
Due 22 October 1987
Resolved 22 October 1987
Fire Fighting
Issued 22 October 1987 Resolved
PROVIDE 20 SECOND TIME DELAY ON FIXED CO2 SYSTEM AS REQUIRED BY 46 CFR 95.15-10(F).
Condition: Unknown
Due 22 October 1987
Resolved 22 October 1987
Fire Fighting
Issued 22 October 1987 Resolved
PROVIDE STORAGE FOR FIXED CO2 BOTTLES THAT MEETS SOLAS 74.
Condition: Unknown
Due 22 October 1987
Resolved 22 October 1987
Unknown
Issued 8 September 1986 Resolved
WEIGHT TEST STANDARD LIFEBOAT AND INSTALL HULL PLATE INDICATING RE- CERTIFICATION FROM 25 PERSONS TO 40 PERSONS.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 8 September 1986 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Construction/Loadline
Issued 26 November 1984 Resolved
IN NUMBER 3 STARBOARD DOUBLE BOTTOM VEE OUT AND WELD 4 CRACKS IN FRAME 94 AT FOURTH BAY FROM CENTERLINE AS MARKED. THIS ITEM TO BE COMPLETED AT DRYDOCK BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984
Construction/Loadline
Issued 26 November 1984 Resolved
IN NUMBER 3 PORT DOUBLE BOTTOM CROP AND INSERT APPROXIMATELY 2 FOOT BY 4 FOOT PORTION OF FRAME 93 AT FOURTH BAY FROM CENTERLINE AS MARKED WHERE CRACKED ABOVE LIGHTENING HOLE. THIS ITEM IS TO BE COMPLETED AT DRYDOCK BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984
Construction/Loadline
Issued 26 November 1984 Resolved
IN NUMBER 3 PORT DOUBLE BOTTOM VEE OUT AND WELD 3 CRACKED WELDS IN FRAME 92 AT FOURTH BAY FROM CENTERLINE AS MARKED. THIS ITEM TO BE COMPLETED AT DRYDOCK BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984
Construction/Loadline
Issued 26 November 1984 Resolved
IN NUMBER 3 STARBOARD DOUBLE BOTTOM VEE OUT AND WELD 2 CRACKS IN FRAME 93 AT FOURTH BAY FROM CENTERLINE AS MARKED. THIS ITEM TO BE COMPLETED AT DRYDOCK BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984
Construction/Loadline
Issued 26 November 1984 Resolved
IN NUMBER 3 STARBOARD DOUBLE BOTTOM VEE OUT AND WELD 2 CRACKS IN FRAME 92 AT FOURTH BAY FROM CENTERLINE AS MARKED. THIS ITEM TO BE COMPLETED AT DRYDOCK BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984
Construction/Loadline
Issued 26 November 1984 Resolved
IN NUMBER 3 STARBOARD DOUBLE BOTTOM VEE OUT AND WELD CRACKED OVERHEAD LONG-ITUDINALS AT FRAME 83 AND SECOND BAY FROM CENTERLINE AS MARKED. THIS ITEM TO BE COMPLETED AT DRYDOCK BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984
Construction/Loadline
Issued 26 November 1984 Resolved
IN NUMBER 3 PORT DOUBLE BOTTOM CROP AND INSERT APPROXIMATELY 4 FOOT BY 5 FOOT PORTION OF FRAME 94 AT FOURTH BAY FROM CENTERLINE AS MARKED WHERE CRACKED AND BUCKLED. THIS ITEM TO BE COMPLETED AT DRYDOCK BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984
Construction/Loadline
Issued 26 November 1984 Resolved
VEE OUT AND REWELD WASTED THRU WELD ON TANK TOP OF FOREWARD STARBOARD ENGINE ROOM DOUBLE BOTTOM. THIS ITEM IS TO BE COMPLETED PRIOR TO THE VESSEL'S DEPARTURE LOS ANGELES.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984
Construction/Loadline
Issued 26 November 1984 Resolved
IN NUMBER 3 STARBOARD DOUBLE BOTTOM BETWEEN FRAES 94 AND 95 ON ANGLED PORTION OF CARGO HOLD CROP AND INSERT APPROXIMATELY A 24 INCH DIAMETER SECTION WHERE HOLDED AND DOUBLED. THIS ITEM TO BE COMPLETED AT DRYDOCK BUT NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984
Electrical
Issued 20 September 1984 Resolved
MAKE REPAIRS TO REVERSE POWER RELAY FOR NO. 1 SHIP'S SERVICE GENERATOR. THE ABOAVE REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF THE COGNI- ZANT OFFICER IN CHARGE MARINE INSPECTION. REPAIRS ARE TO BE COMPLETED PRIOR TO 28SEP84.
Condition: Unknown
Due 20 September 1984
Resolved 20 September 1984
Unknown
Issued 20 September 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V INGER, O.N. 248011. THE FOLLOWING DEFICIENCIES ARE TO BE COMPLIED WITH BY 28SEP84.
Condition: Unknown
Due 20 September 1984
Resolved 20 September 1984
Construction/Loadline
Issued 20 September 1984 Resolved
MAKE PERMANENT REPAIRS TO THE TANK TOP IN THE FORWARD LOWER PUMP ROOM TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION. REPAIRS TO BE COMPLETED AND AIR TESTED NOT LATER THAN 28SEP84.
Condition: Unknown
Due 20 September 1984
Resolved 20 September 1984
Construction/Loadline
Issued 3 May 1982 Resolved
TWO HOLES IN BOW, ONE AT 20 FT LEVEL, ONE AT 38 FT LEVEL. PERMANENT REPAIRSTO BE MADE IN CORPUS CHRISTI, NO CG835 ISSUED.
Condition: Unknown
Due 20 May 1982
Resolved 3 May 1982

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.